Loading...
WA9601-SP 981104SHIMEK, JACOBS & FINKLEA, L.L.P. CONSULTING ENGINEERS DALLAS, TEXAS Date: Landmark Structu , Inc. 1665 Harmo oad Ft Wort exas 76177 · : . winnea Re: City of Coppell Wagon Wheel Ranch Elevated Storage Tank We are transmitting herewith two copies of the submittal data furnished by Landmark Structures, Inc. reviewed and marked as follows: Dwg. No. 10 11 12 13 14 15 17 Explanation No Make No. Exceptions Corrections Sheets Dwg. Description Taken Rejected Noted Floor Drain XX Access Door XX Rolling Steel Door Backflow Preyenter Backflow Preyenter Junction Box Wall Feed Thru Plates and Boots Welding Procedures and Certifications XX XX XX XX XX November 4, 1998 These copies have been Revise Submit and Specified Resubmit Items Remarks: By copy of this letter we are returning two copies of the submittal to Mr. Larry Davis, City of Con. p,ql. By: ~ ~ ~ Paul A. Carline, E.I.T. Checking of shop drawings by Shimek, Jacobs & Finklea, L.L.P. is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Any action shown is subject to the requirements of the plans and specifications. Contractor is responsible for: dimensions which shall be confirmed and correlated at the job site; fabrication processes and techniques of construction; coordination of his work with that of all other trades; and performing his work in a safe and satisfactory manner. LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 TO: Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE A'R'ACHED ITEMS: Copies Spec Section Submittal No. LETTER OF TRANSMITTAL Date Attn: Re: Job. No. 11/2/98 9802 Mr. Gary C. Hendricks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas Description 5 Sht. 4 10 Floor Drain THESE ARE BEING TRANSMITTED: Information for Record O&M Data X Information for Engineer's Approval X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS I REMARKS: Signed Joe Swinnea R-4937-A Cast I!ron Floor Drain with Grate nt Duty Outlet for 3-inch inside pipe caulk. , R-4937-B Cast Iron Floor Drain with Grate Light Duty Outlet for 4-inch inside pipe caulk. R-4937-C Series Floor Drain Frame with Hinged Strainer Light Duty Catalog No. R4937-C 1 R-4937-C2 R-4937-C3 Size -- Dimensions in Inches to fit 4" soil pipe. to fit 5" soil pipe. to fit 6" soil pipe. PIP[ 12Xl2" PERFORATED LID I4'''' ~,~\\'~ k',\',l k',\'4 k\\',l k'x\',d k~ ";' Shown with grate removed. R-4938 Transit i~"ram~ and Grate Light Duty Total Weight 82 Pounds "IF,"' IFy Z'~ I ~ '-*IN %~ ~ 2 R4938-1 Double Transit Unit Light Duty Total Weight 135 Pounds '3 (Not Illustrated) See R-4938 far style. 25~ 222 NEENAH FOUNDRY COMPANY · ']~ '1 17-112 - 4 LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 TO: Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE A'R'ACHED ITEMS: Copies Spec Section Submittal No. LETTER OF TRANSMITTAL Date Attn: Re: IJob. No. 11/2/98 9802 Mr. Gary C. Hendricks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas Description 5 SC.8 11 Access Door THESE ARE BEING TRANSMITTED: Information for Record O&M Data ,~NO EXCEPTION TAKEN [] MAKE CORRECTIONS NOTED [] REJECTED [] REVISE AND RESUBMIT [] SUBMIT SPECIFIED iTEM Checkin;~ i~ or:iv for gsnrx!s! ccnfo:mar, ce wV:h the design CE~RC~D~ of ::'~:~ [;to:,',:~ a.'~f~ ~,~:-.:.;'ai con:p"~a~ce ,.d~h hi:,?r:?}:'z:~a 5:!'.,''-[3 h~ z-~t:: co;l!~.::cL ('~.:~CL;~:..F~'% A:~¥ Si,";;q i? ~-; (:,71 t~ {~"t:! lCqL:::"{7.¥':[~ Of [the p~cng. ;tnd ~p.?c:}', ~':'}' r... ,:e~'[::.. :o~' {s rc:%~s;-:A?fie for: ~'.h~'h ~z:~.:}2 },r: ,'{:~-~:::::='-~ and co}re;sted at the lob si~e; or{Jh~e~icn c,f t~T.e ,,,~or;{ ,,,,~fi~ th:3~ df at] oPhur {r,~{~es and CONSULTING ENGINEERS DALES, TEXAS X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below, EXCEPTIONS I REMARKS: Please note that a fiberglass door is being submitted as an exception to the specified "hot-dipped" galvanized door. This change has been discussed with Mr. Paul Carline of SJ&F. 2. The color of the door is to be light gray. Joe Swinnea CHEM-PRUF O00R COE~PANY, INC. P,O. BOX 4568 DROWNSVILLE0 TEXAS 28528 1-88e-531-7'tB7 CONTRACTORI L~ndmark sfrucfures ENO USER~ I TAG LOCATION SINGLE 3-e x 7-~ DO~R AND FRAHE GUST, P,O,H NOT ISSUED ENVIRONMENT FSA5~' oF I,~.EVATE r~ c - DIMENSIONS~ B(~ 't0 01/0'!' BY 86 BI/0't' Wail OpenlnO ~ 38 85/08' BY B5 03/0B' Inside Frame Opening C - 3~1 el/IE]'i' By 8't el/e2' Exact Door Size O - Exect Transom Size CHEH-PRUF , ORDER th I EA 3 EA I EA .......... ~. I EA PARTS LIST AND SPECIFICATIONS UNDERCUT CENTERLIFE Brute I Frome, 8atid FRP Htn3e,Chem-F'rul; HSBB US32D ~p LOCK, HL2224NSA H21 US32D Closer, Norton 7580 AL Slond~rd Color Cher,-PruF 83184' 39 89/ DOOR th , " (A FRAHE 1HICIQ-tE58 85 EXI'ERIOR DOOR FRAME STYLES I~TYLE ~ El sTYLE n J'JSTYLE L SPECIFICATIONS FOR CHEM-PRUF FIBERGLASS DOORS AND FRAMES 08 100 - FIBERGLASS REINFORCED PLASTIC DOORS AND FRAMES 1.0 GENERAL 1.1 SCOPE - This section appIies to flberglass reinforced plastic {FRP) doors, frames, and transoms as manufactured by CHEM-PRUF~00R COMPANY, BROWNSVILLE, TEXAS (1-800-444-6924). 1.2 SUBMITTALS - Shop drawings shall provide pertinent dimensions, hardware locations, transom and lite sizes, louver locaLions and dimensions. and door elevations. Mortises for hardware must be molded in at the factory as the door is built. Mortises shall not be routed or cut out of the stile structure or the jambs. 1.3 PRODUCT HANDLING o All materials shall be delivered to the site in sealed. undamaged containers fully identified with the manufacturer's name. project number, the tag location, the door type, color and weight. The doors and flames must be. shipped in wood crates with wood perimeters. Store materials in original caztons, on ddge in such a way to prevent falling or damage to face, comers and edges. PRODUCTS DOORS - Door shall be made of flberglass reinforced plastic (FRP) using resins tailored to a specific corrosive envtronment (stated by the purchaser at the time the order is placed) and have a fiberglass content of 25% by weight. The doors shall be flush construction. having no seams or cracks. All mortises shall be molded in at the factory. The doors shall be 1-3/4" thick with a 15 mil (plus or minus 3 mils) color gelcoat and have an R-factor of 12. Secondary painting over pultrusions to achieve color is not acceptable. STILF_~ AND RAILS - Shall be constructed starting from the outside toward the inside, of a 15-20 rail gel coat of the color specified followed by a matrix of at least three layers of 1.5 ounce per square foot offiberglass mat. The stile and rail shall be molded in one continuous piece to a U-shaped configuration and to the exact dimensions of the door (patented). In this manner there will be no miter joints or disparate materials used to form the one-piece stile and rail. Pultrusions will not be acceptable for stiles and rails as (1) the color gel coat is not an integral part of the structure (it must of necessity be applied as a paint when the structure is assembled), and (2) mortises must be cut into the pultrusions. thus weakening the pultrusions by removing as much as two-thirds of its thickness and (3) the practice ofmiteredj oints in pultrusions leaves access areas for penetration of contaminants to the inside of the door. DOOR PLATES o Shall be molded in o/~e continuous piece, starting with a 15-20 rail gel coat'of the color speckfled, integrally molded with at least two layers of 1.5 ounce per square foot fiberglass mat and layer of 16 ounce per square yard unidirectional glass roving. REINFORCEMENT - Adequate reinforcing and compression members shall be used to accommodate surface hinges, closers, locksets, kickplates, push or pull plates. When engineering considerations dictate, mild steel is buried in the ~berglass matrix to provide enhanced screw holding power. In no case should screws be used into flberglass matr~ to provide holding for hinges. locks or closers or any structured attachment. Thrubolting is recommended for attachment of hinges, and closers in as much as the strength of thruboltmg is five to six times as great as edge attaching with screws. When thruboltmg is to occur, a compression member is to be located which will provide memory and resistance to the torquing of thrubolts. All voids between the door plates shall be completely f~led with the equivalent of pounds expanded polyurethane foam, having a flame spread of 25 or less perASTM E- 84. A phenolic-coated kraft honeycomb may be substituted for urethane foam where engineering requirements dictate. 2.0 2.1 2.1.1 2.1.2' 2.1.3 i i 2.1.4 2.1.6 2.2 2.2.1 2.2.2 2.3 2.4 2.5 3.0 3.1 4.0 4.1 FLAME SPREAD - Ah 'reinforcing resins shall contain a halogenated additive or co- reactant plus Antimony Trioxide to achieve a flame spread of 25 or less per ASTM E-84 and shall be self-extinguishing per ASTM D-635. EXCEPTION: USDAAND FDA standards require special resin formulas for food contact. State in the door schedule ff FDA standards must be met. WINDOW LITE8 - All wLadvw opcah'~gs and iouvcr opcning3 in thc door cchedulc should bc moldcd intcgralIy with both door platca so that no moi~,turc may iDenetrate the door cavity through the v, indow Iitc 3tructurc (patchted). Window litco · shah bc ~tructurslly rctaincd by at icaat i ~bcrglass glazk~g pi~s a~,d scalcd h-~ auch a martact that t_hc i~,tcg~ity of the scala remain intacl. Cutting .a window opening in the door and the use of either pultruded shapes for window ledges or the use of externally applied picture frames appliqued to retain the glass are unacceptable where sanitation and cleanliness are desired. COLOR: .~~. of the door or frame shall be integrally molded as the part is made. NOTE: In most cases, the color can be provided to meet the desires of the client. White and grey are standard colors, but almost 'all colors can be matched. The deposit of 15-20 mils of gel coat is the equivalent of 50 to 60 coats of pat applied by spray. In areas of severe exposure to the sun, the color white is recommended because of its high refractive indes. This leads to enhanced color life. and lower temperature differential between inner and outer door faces due to heat absorption. FRAMES - Frames shall be similar to the doors in construction and materials except the frames shall be soIidftberglass. The stop and frame will be molded all in one piece. The frame shall be integrally gelcoated to the customer's color when molded. MortiSes will be molded in. It is not permitted to rout in mortises or remove any material from the head or jambs, to provide mortises. Reinfc~rcement for mounting hinges, closers. etc.. shall be of mild steel plates strategically located and buried in the resin-glass matt-De so they will not be exposed to the elements. The jamb shall be fiat on the backside (against the opening) and uniform in thickness so as to provide a solid, uniform surface against the wall opening. No wood blocks or spacers are permitted. LOUVERS - Louvers shall be identical to the doors in construction and materials. The fins shall be solid fiberglass. [Patented) TRANSOMS - All transoms shall be identical to the doors in construction. materials, thickness, and reinforcement. ., HARDWARE - ALl hardware where applicable (locksets, hinges'. closets, etc.) shall be installed at the door manufacturing plant. The hardware rnanufacturer's warranty shall be included with the hardware installation. Chem-Pruf sbaII not be responsible for improper installation of hardware which is installed by others. INSTALLATION - Installation sh~lI be in strict compliance with manufacturer's written instructions using non-corrosive materials and methods. GUARANTEE - Chem-Pruf Door Company shall unconditionally guarantee its registered doors for TEN years against failure due to corrosion from the specific environment named at the time of purchase. See written guarantee. NOTE: TO SPECIFIER OR PURCHASER This specification relates to Chem-Pruf Doors only. Incorporated in this specification are four U.S. patents. Since the patents are of such importance to the performance of the end product. there carmot be an "OR EQUAL" when this specification governs. CHEM-PRUP DOOR CO. THE ABILITY TO WARRANTY A DOOR FOR LONG PERIOOS OF SERVICE DEPENDS ON MATCHING THE ENGINEERED RESIN SYSTEM TO THE ENVIRONMENT. SUCH CHEMICAL MATCH IS ONLY POSSIBLE WHEN THE MANUFACTURER HAS THIS CAPABILITY IN HOUSE AND MOLDS ALL PARTS OF THE SAME RESIN SYSTEM. THIS CANNOT BE ACHIEVED WHEN PULTRUSIONS ARE OBTAINED FROM ONE PLACE OR ANOTHER. ~ GLASS PANE IMBEDDED "" IN SEALANT THE MOST SANITARY DOOR WINDOW EVER DEVISED. THIS IS E~CLUSIVF_. THE LEDGE IS INTEGRALLY MOLDED AS .A PART OF THE DOOR PLATE. GLAZJNG IS SET IN A BED OF SIUCQNE USING FIBERGLASS GLAZING PINS. APPRQVED BY USDA & FOA. THERE IS NQ PLACE FOR A GERM TO HIDE. CUTTING THE DOOR PLATES AND USING A DROP IN WINDOW KIT IS A POOR SUBSTITUTE. ALSO, THE USE OF PICTURE FRAMES ON EACH SIDE OF THE WINDOW END UP COLLECTING GERMS OR CO NTAM I NANTS. CHEMICALLY BONDED THE ONE PIECE STILE AND RAIL STRUCTURE MOLDED ALL AT ONE TIME IS NOT AVAILABLE ANYWHERE ELSE. IT MEANS THAT THERE IS NO PLACE FOR CONTAMtNANTS TO ENTER, AS AT MITER JOINTS WHEN PULTRUSIONS ARE USED. IT ALSO MEANS THAT THE STRENGTH OF THE ONE PIECE CONSTRUCTION IS GREATER THAN THAT ACCOMPLISHED WHEN A JOINT IS MITER CUT AND GLUED. CHEMICALLY BONDED THE ONE PIECE STILE AND RAIL STRUCTURE WITH THE COLOR AND ALL MORTISES MOLDED IN, IS MADE WITH CONTROLLED CHEMICAL SYSTEMS. THE PLATES OF THE DOOR AS WELL AS THE INTERFACE BONDING IS MADE IN THE SAME RESIN SYSTEM. THE RESULT IS THAT THE CQOR AND FRAME ARE ONE HOMOGENEOUS AND ENGINEERED RESIN SYSTEM INCORPORATING CHEMICAL AS WELL AS PHYSICAL BONDING. THEY ARE THE STRONGEST INTERFACE BONDINGS KNOWN ANYWHERE. THE INTERIOR CAVITY OF THE DOOR IS COMPLETELY FILLED WITH 4-6,f DENSITY POLYURETHANE FOAM PRODUCING R FACTORS UP TO 12. WHEN ENGIN.EERING PARAMETERS DICTATE, A PHENQI IC COATED KRAFT HONEYCOMB MAY BE USED. MORTISE MOLDED IN IVIORTISES FOR LOCKS IN THE DOORS AND JAMBS AS WELL AS HINGE POCKETS IN THF JAMBS MUST BE MOLDED IN ANO REINFORCED BY STEEL ,RATES IMBEDOED IN THE FIBERGLASS MATRIX. /VOTE.' IF PULTRUStONS ARE USED IT MEANS THAT STRUCTURE IS REMOVED TO FORM MORTISES, THIS SERIOUSLY WEAKENS THE VERY AREA OR LOCATION THAT, NEEDS THE MOST STRENGTH. WOVEN ROVING iiii~ >' ;~; ; 2}}~>////i, CONSTRUCTION: THE RBERGLASS LAMINATE CONSISTS OF A 15-20 MIL GELCOAT LAID DOWN ON A MOLD SURFACE IT IS THE FIRST UNE OF OFFENSE AGAINST CHEMICAL ATTACK AND PROVIDES T'r CUSTOM COLOR. LAYER~ OF GLASS MAT AND ROVING SATURATE WITH RESINS SPECIFICALLY TAILORED TO THE SRECIRED ENVRIONMENT COMPLETE THE LAMINATE. THIS IS ALL ONE PROCESS, COMPLETED IN MOLDS. AiOTE: THE HIGHER THE RESIN CONTENT OF TH RiP LAMINATE. THE BETTER THE LONG TERM CHEMICAL RESISTANCE. A RATIO OF 70% RESI TO 30% GLASS IS OPTIMAL. (-,-5%) MANUFACTURERS OF CORROSION RESISTANT FIBERGLASS DOORS-FRAMES-LOUVERS ! '~ '1 ' ., ] WHEN HARDWARE IS TO BE APPUED, THRU-BOLTING TO THE DOOR IS RECOMMENDED. THRU-BOLTING IS 5 TO 7 TIMES AS STRONG AS THE USE OF SCREWS. (RBERGLASS HAS POOR SCREW HOLDING CAPABIUTY). WHEN THRU-BOLTING, A COMPRESSION MEMBER IS NEEDED THAT RESISTS TOROUING BUT HAS MEMORY TO RETURN TO ORIGINAL SHAPE. TREATEO WOOD BLOCKS THAT ARE SEALED IN FIBERGLASS RESIN ARE NON-HYGROSCOPIC AND MEET THAT REQUIREMENT. THE REINFORCING BLOCKS ARE USED AT HINGE, CLOSER, LOCK, PANIC DEVICE ANO KICKPLATE LOCATIONS. THEY ARE MARRIED TO THE STILE ANO RAIL STRUCTURE. (PLASTIC BLOCKS LACK MEMORY RESULTING IN SCREWS OR BOLTS CONTINUALLY WORKING LOOSE). SOLID-ALL FIBERGLASS FRAME WITH MOLDED IN COLOR, (EXCLUSIVE), .HARDWARE ATTACHING POINTS REINFORCED WITH BURIED STEEL PLATES, SIMPLE INSTALLAT1NG SYSTEM, FRAME IS ATTACHED TO WALL O~NING WiTH POLYMERIC BONDING SYSTEM AS WELL AS STAINLESS STEEL SCREWS AND ANCHORS (SUPPLIED), THE CHEM-PRUF DIFFERENCE ENGINEERING AND CHEMISTRY CUSTOM-MATCHED TO THE ENVIRONMENT AND USE. · FIRST TO BUILD A SUCCESSFUL FIBERGLASS DOOR. - · FIRST TO TAILOR RESIN CHEMISTRY TO MATCH THE CONDITIONS WHERE USED. FIRST TO DESIGN AND BUILD THE ONE PIECE STILE AND RAIL (EXCLUSIVE). FIRST TO DESIGN AND BUILD THE INTEGRALLY MOLDED WINDOW (EXCLUSIVE). EIRST TO OFFER AN UNCONDITIONAL i0 YEAR GUARANTEE AGAINST FAILURE DUE TO CORROSION. FIRST TO OBTAIN USDA AND FDA ACCEPTANCES FOR FOOD CONTACT (1975). FIRST TO MOLD A SOLID ALL FIBERGLASS FRAME (EXCLUSIVE). FIRST PATENTS ON ATMOSPHERIC RESISTANT DOORS IN U'.S. PATENT OFFICE EVER ISSUED. FIRST TO BUILD SUCCESSFUL GELCOATED INDUSTRIAL FRP LOUVERS. AERODYNAMIC SHAPE, MODULAR DESIGN, FIELD ALTERABLE. (PATENTED) | ;/?~~ 1~14 x 2' SLT SCREV S.S. ~ ZPLAST!')C ANCHOR ' TYPE HARDY'ARE HOUN'FING A~SY. HARDVARE ASSY.////~~ STYLE [ FRAME BONDING MATERIAL ( CHEM- RUF SUPPLIE'D ).- P TO ER STANDARD FRAME WIDTH = 5-3/4' SPECIAL FRAME ORDERS = 4% F-1 & 5' VARIES TYP. STYLE I HDUNTINE] CHEH-PRUF DOOR CO., INC. BROVNSVILLF TX. PATENT & COPYRIGHT FIBERGLASS FRAHES STYLE I MOUNTING SCALE { DRAVINGN0. I DRAVN BY } FULL CPFRNNTI D. RAMOS REv. 0 I t,,,. 8' CMU VALL .... CAULKING (2 PL) BY OTHER STYLE I FRP FRAME via, ss SCrEwS ~ PLASTIC ANCHORS STAGGERED e 18' FRP DOOR PER DOOR SCHEDULE N0fE= REGULATES DEGREE Or SVING 90 TO 180 HEAD DETAIL STYLE JAM~  BONDING AGENT (BY C.P.) STYLE I FRP FRAME NOTE: STEEL [NBEDDED IN VARIES ~ FRP DOOR PER ~ CAULKING (2 PL) BY OTHER NOTE: REGULATES DEGREE OF SVING 90 TO 180 DETAIL STYLE I 1 SCALE FULL CHEM-PRUF DOOR CO., INC. BROVNSVILLE TX. PATENT & COPYRIGHT FIBERGLASS STYLE [ FRAME HEAD & JAMB DETAILS DRAVING NO. DRAVN BY I CPHJD[ D. RAMOS RFV. 0 - - 'r T ,,) ,,) CHEH-PRUF 304 STAINLESS STEEL NRP- HALF SURF ACE HINGE C P~LY~ER'; :BEARING REVERSIBLE PIN 1 1/2' 1 314-' 11/161-- h 1' ~////' 4 1/2' 13t4' 1/2 · --.- NOTE: 304 SS HINGE COMES WITH A NDN-REMOVEABLE PIN. 11 I I I I I t 1/2' T 11/8' 1 1/4' --___+ 11/8' I q ~- 3/8' PIERCED & COUNTERSUNK FOR 1/4' THRU 30LTS <3) PLACES SHOWN BPP, PIERCED & COUNTERSUNK FOR 12-24 OVAL HEAD M.S. (4) PLACES id,, JAMZB 8-38 X 3/16 SS SET SCREV DOOR "' 9/16,T'I "'--' 2 9/16' --" 3/16' 1 2 1/16' ANSI STD. 4-1/2' TEMPLATE HINGE CHEM-PRUF DnDR CD., INC. ])RDVN~VILLE TX. PATENT & t'DPYRIGHT CHEM-PRUF HARI]VARE STAINLESS STEEL 304 HALF SURFACE HINGE ; gCA& E ) DRA%/INC, NIl. I DRAVN BY i RTV, FULL CPHGHSSS ID. RAMDS I' Applications Mortise Locksets ML2200 Series Applications Designed for high-traffic con~mercial, i,~stitutional, industrial and government buildi,~gs where security is of the greatest concern. The wide array of trim designs and functions meets or exceeds all A_MS[ Grade I performance requirements, while provid.- ing the reliability, versatility and security that owners and specifiers demand. Typical high-use applications may include: · Offices · Factories · Schools · Hospitals · Hotels · Municipal buildings · Stores · Theaters Advantages · Meets or exceeds AaNSI Grade 1 · Provides life safety and security in a single door prep. saving the additional cost of a deadlock · Throughbolted u-ira designs for proper alignment and increased security · Trim designs compatible with other Corbin Russ~n cylindrical. pre-assembled and exit device trims · Can be used with new or exisdng Corbin Russwin key systems and those of most other manufacturers :*'.!' ': ',;! I-.,.!',: .' ApplicatiQnSL. ;:L:L:'):i:L)." 2 Functions 4 Trim De~igris:".'"' ~' :": ~ 6 Options and Accessories 24 How to Order 26 Helpful Terms 28 How to Specify 29 Finishes 31 eatureS ..... Mortise Locksets ML2200 Series Features Handing Handed; field reversible. Door Thickness 1M" standard. Optional door thicknesses a~,nilable; ~'e individttal U'im designs or How to Order, page 27. Backset 2:Y~". Lockcase Heavy gauge chrome plated steel. 5W'x4"x,~%6". Optional: non-ferrotts lockcase for corrosion resistance; see How to Order, page 27. Front Heavy gauge steel, 8" x 1 W' x ~;". Accommodates flat doors and doors beveled W' in 2". Armored Front Wrought brass or bronze, attached by machine screws to lockcase front. Latchboa ,' 2-piece mechanical, b~, with"itainless steel anti-friction insert. Auxiliary Latchboa ~A6" effective throwand ~" effecdve auxiliary latch deadlocking. Deadboa One-piece stainless steel, :9/31' x 1%" x l" Hub Knob: nickel steel, -%" x Ym". Lever: steel, 8mm. Spacing C. to c. knob/lever to cylinder: 3Ys". C. to c. knob/lever to thumbturn: 27A6''. Strike Wrought brass or bronze, ANSI straight lip standard, 47/8.` x t W' x 1Vi' lip to center. Opdonal strikes, lip lengths and ANSI wrought strike box available; see How to Order, page 27. ML2200.3 Cylinder Brass, 6-pizt, L4 ke.~,vay, 0-billed standard. Optional cylinders agailable; see How to Order. [)age '_>7. Keys Two ,tickel silver standard. KeyinS Features ~vailable Mitqter keylag Co,~su'ucdon master keying Visual key ct n re'el Concealed key control P[ug only to show (concealed shell) 7-pin c)'[inde,' High security c,,'linder [nterchangeable core (IC) High sect, tit3,' [C Master ring Q'linder Blockout cylinder Flex head Q'linder Warranty One-year limited. Armored front conceals lock mounting screws and one-piece bea~' gauge steel front 1" throw. one-piece stai,dess steel deadbolt meets Security Grade I Heavy duty }';' throw latchbolt with stainless steel insert provides positive, ~cure latching Cedificati0n/Compliance ANSI Meets A156.13 Sedes 1000, (;n~dc' 1. Meets At 17.1 Accessibility C/odc. Meets FF-H- 106C. LIt/ULC All locks listed for A label and lea,set cla~s doors, 4' x 8' single or 8' x 8' pair. Letter F and UL ~nmbol on armored f,'ont indicate listing. California State Reference Code (Formerly Fttle t P, California State Fire Marshal Standard) All levers with returns comply; levers retttrtl to within W' of door face. Finishes BHMA 605 Bright Brass BHMA 606 Satin Brass BHMA611 Bdght Bronze BHMA612 Satin Bronze BHMA 613 Dark Oxidized Satin Bronze, oil rubbed BHMA 625 Bdght Chromium Plated BHMA 626 Satin Chromium Plated BHMA 629 Bright Stainless Steel -- 6-pin solid brass Q'linder standard; optional cylinders available Lockcases can be converted from knob to lever Heavy gauge internal parts provide security, reliability and durability / . '.Ctions "' ...... ,.,Mortise Locksets MI · "Function Type cn ML2211 2200 Series ANSI No.' - ~ad~lt by key ou~ide. - No i~ide operation. ML2212 Deadlock ML2213 Deadlock Deadlock Classroom Deadlock Passage or Closet '-,Privacy Bedroom or Bathroom · ML2222 Store Door ML2224 Entrance or Storeroom ML2229 Hotel or Motel .~21~ Bedroom or ..,... - ·. Bathroom F18 F16 - Deadbolt by key either side. F17 - Deadbolt by key outside or by thumbturn lever inside. - Deadbolt by key outside. - Thumbturn lever inside retracts deadbolt only; will net project deadbolt. - Latchbolt by grip either side. - Both grips always free. - Latchbolt by gdp" either side. - Deadbolt by thumbturn lever inside or by emergency release tool outside. - Latchbolt by grip* either side, i - Deadbolt by key either side, F14 .'.u ~--_- .... ~ ~-_~,.~ F21 . .. - Latchbolt by grip* either side. ' ~" - Deadbolt by key outside or b ' ' . - Latchbolt by gdp inside and by guest key or master key outside. - Outside grip always rigid. F15 : - Deadbolt by thumbturn lever inside or by emergency key outside. : - Inside grip simultaneously retracts latchbolt and deadbolL ,, : ,:.~, - Emergency key shuts out all other keys. ,, ~, - Auxiliary latch deadlocks latchbolL ;~:.. :.:'!= ; :~,i~ ~- Latchbolt by grip eiffier side. ;i ' Deadbolt by thumbturn lever inside, by rotating inside grip, or by emergency ~ release tool outside. ~.,; - Inside grip simultaneously retracts latchbolt and deadbolt. qlndicates dCd grip. Corbin Rdss,mnn ~. I I II ML2200. 4 ":'=i'i;imDesigns-::.:,::'- ,Mortise Locksets ML2200 Series Newport Complies with codes reqttiring lever to return within V_," of door face. Brass, I~ronze or stainless steel NSA ~ Lever: Cast Rose: Wrought Door thickness: t~s", 1~4", NSB Lever: Cast Rose: Cast Door th ckness: P/e", I,'Y4", 2V4" 3/16~ 25/6" , NSM Lever: Cast Escutcheon: Wrought Optional: Plug only to show; master ring Door thickness: FVs", FY;, 2V4" I ! ML2200, 12 Mortise'Locksets Quick Codes 2200 Series 'HOW to Order Cylinder and Keying Description Specify conventional 6-pin (standard) Conventional 7-pin 7P Less cylinder(s) LC High security HS High security IC CHS IC 6-pin C6 IC 6-pin with temporary construction core CT6 IC 6-pin less core CL6 IC 7-pin C7 IC 7-pin with temporary construction core CT7 IC 7-pin less core CL7 Master ring MR Blockout function cylinder B0 Flex head cylinder, 6-pin (sectional trim) FX6 Flex head cylinder, 7-pi.n (sectional trim) FX7 Flex head cylinder, master ring (sectional trim) ~,._:... '~ FXM Plug only to show, 6-pin (concealed shell) P06 Plug only to show, 7-pin O-bitted with 2 blank keys (standard) Keyed random KR Construction master keyed CMK Visual key control (VKC) - Keys only VKC1 - Cylinders and keys (not for HS or CHS) VKC2 - Cylinders only (not for HS or CHS) VKC3 Concealed key control (CKC) - CKC cylinders with VKC keys - CKC cylinders only 2 keys per lock More than 2 keys CKC2 CKC3 (standard) k'Y# (e.g., KY6) Finish Description US3 Bdg.ht.B...r:a_.ss. US4 Satin Brass US9 Bright Bronze US10 Satin Bronze US10B Dark Oxidized Satin Bronze, oil rubbed US26 Bright Chromium Plated US26D Satin Chromium Plated US32 Bdght Stainless Steel US32D Satin Stainless Steel Door Thickness Handing Hand: Right Hand Left Hand Left Hand Reverse Specify Doer Sectional Escutcheon* 605 Thickness Trim -Specify Trim -Specify 606 13/6" 0138 0138 611 1~4" (s~ndard) (standard) 6i2 1%" 0178 N/A 613 2" 0200 N/A 2W' 0218 N/A 625 2W' 0214 0214 626 2~s" 0238 0238 629 2W' 0212 0212 630 2~8" 0258 0258 2~" 0234 0234 2%" 0278 0278 3" 0300 0300 3~'' 0318 D318 Specify 3V," 0314 0314 RH 3~a" 0338 0338 LH 3~'' 0312 0312 RHR 3s/s" D~5~ !>;' ~Z" 6358 LHR 3¥~" 0334 0334 3%" 0378 0378 4" 0400 0400 Strike ............... ANSI'~:': 'AN~ ..... Lip to Straight Lip Curved Lip Center Specify Specify %." SS078 N/A fV~" (standard) N/A · lV4"' SSl14 SAl14 1 ~" SS138 SA138 ' ll~" SSl12 SAl12 13A" SS134 - SA134 2" SS200 SA200 2 V4" SS214 SA214 2Vz" SS212 SA212 2¥4" SS234 SA234 3" . SS300 SA300 o e.n: Sa : k ::;O,'o rThickn:ess spoc. ~:: ~":~*~" :' ~ 13/4" SB134 : 2" SB200 , :,~:.'~-:~:.;..,:,!, i: ,.~::2V4",'SB214 Rabbe(edfront and'strike - Specify sR118 *For 2~" to 4" door thickness: throughbolts and thumbturo_le. yer_ Spjod!.~ _fOr_4_"_d_oo_/r wil__Jbe_~p_Eq_vid_ed; maybe field3c~t. - Miscellaneous Options Description Specify Spanner head screws M02 ANSI wrought strike box M17 Occupancy indicator M19 :nnqjn~ide only Knuding inside only M22 Abrasive coat outside and inside M23 Abrasive coat inside only M24 AbrasiVe coat outside only M25 Non:ferrous lockcase M26 Lead wrapped case M29 Half trim (for ML221 O, M1_2220, M30 M. L2'.2?.j4i' ML2222~ ML2255 M1_2257' Only) Working trim only M31 ML2200.27 Norton Series 7500, Normal Power Range, Adjustable Sizes 2 thru 6. [] Series 7500 BF, Accessibility Code, Adjustable Sizes I thru 4. Multi-Size Door Closers Series 7500/7500 BF Installed Regular Arm Series 7500/7500 BF Installed Parallel Arm Series 7500/7500 BF Installed Tot~ Jamb · Norton Series 7500 Ordering Information """jering Intormation ,'ton Series 750017500BF Multi-Size Closers are available with a variety of options. Use the following outline to select the correct Catalog Number for the type of closer you require. Prefixes - DeslanRte the tree in InstallaUon. a~.rn: parallel arm or top jam.i~ Io~er Tf[s~lls top jamb only· See page 7500-7 for specific frame face requirements, frame reveal and minimum door swing data: Series J7500 - Closer with long secondary arm fo~ deep reveals - up to 15(Y' door swing. Series JL7500 - Closer with long main and secondary arms for deep reveals for door swings 150' to 180e. "P" - Closer installs parallel arm only when using other than standard soffit plate or with low profile arm, P7580, P75808F closets; "PR" - Parallel Rigid Arm with Third Digit - De~ne~ the tvoe of arm. "0' - ~pecifie~ a 'standard arrrt for hoTd-open. -r - sp.,,~ ~ ,~,,~ ~,u,,,. -.~ tor non-hold-open closets only. (Order drop plate for Top Jamb installaUons.) Packaging Information Series 7500 Closers are normally packed for Tri-Style installation one to a box. Included am the closer with cover, appropriate arm and mounting shoe for Regular Arm or Top Jamb mounting, for reveals up to-3" (76ram), and minimum frame face of 3-1/4" (83mm). It also includes a soffit plate for Parallel Arm mounting, a hex-key for control valve adjustment, installation instructions, and both screws and machine ..,~closers will also include a 9we for mounting. Hold-Open hold-open adjustment wrench. When ordered specifically for Top Jamb deep reveals (J or JL prefixed closets) the closer is supplied with Top Jamb mounting shoe and a 7786 back plate. Closets ordered with special Parallel Arm soffit plates, Parallel Rigid Arm or Narrow Profile Arm are supplied with that specific type of mounting only. Special Fasteners Thru-bolts and groinmet nuts (TBGN) or sex-nuts (SN) are available to order. Closer Finish (see page 7500-2) "H' - Hold-Open Closer (specify hand for PR ck~sers). "M" - Metal Cover (specify plated finish, spec/fy hand for Top Jamb dosere). "W' - Wood Laminated Steel Cover (specify wood grain; specify hand for Top Jamb closer). "DA" - Adjustable Delayed Action Closing. Available in addition to standard adjustable backcheck pesi{ioning and adjustable backcheck cushloning: 7500-2 Application The Notion® Series 7500 door closer combines the features of the Series 7700, our finest door closer, with a spring that permits power adjustment through a. range of sizes. These closers are available in two distinct power ranges. Series 7500 are Normal Power Range Closers and are adjustable in a 2 thru 6 size range. These closets can be installed and adjusted to conform to the power requirements of conventionally- sized closers. Series 7500BF are Accessibility Code Closers and are adjustable in a I thru 4 size range. This closer is lighter-powered than the Series 7500 to reduce the door opening resistance to manageable levels for the handicapped and still provide acceptable door control. The Series 7500/7500BF closers have a complete range of separate control adjustments: sweep speed, latch speed, backcheck cushioning. and backcheck positioning. Adjustable delayed action closing is also available as an option. Series 7500 closers are narrow projection door controls: projection is just 2-118" from the surface of the door or jamb. They are complete with covers that can be finished to suit the decor of other builders hardware. They are available with sprayed covers or BHMA plated finishes. Or, w,hete appearance is an extremely important consideration, covers are available in a wide variety of laminated wood grains to complement the door and frame. Norton Series 7500/7500BF closers are non-handed and are packaged with both a mounting shoe and soffit plate. Any Series 7500/7500BF can be installed Regular Arm or Parallel Arm. It can also be installed Top Jamb where frame face and frame reveal permit. Further, it can be installed on either right or left hand doors. Norton Series 7500 closets are the answer when the specifier and the building owner wish to combine the finest door control with wide range power adjustment. Series 7500BF closers combine the features of the Series 7500 closer with reduced opening resistance to comply with accessibility code requirements. These closets can be specified and installed with the knowledge that they will provide smooth dependable door control. And with a minimum inventory, the building owner has door control for any normal replacement or expansion requirement. Some special applications are also available with the Series 7500/7500BF door closers. Series 7580/7580BF closets are supplied with a narrow profile arm Norton Series 7500 General Information for non-hold-open installations where ceiling or top rail of door provide minimal clearance. And Series PR75001PR7500BF are supplied with a rigid forearm for Parallel Arm installation where heavy use is anticipated. ANSI/BHMA/Federal Specs The Series 7500 door closer has been tested and is certified by an independent testing laboratory as being in compliance with the Grade 1 requirements of ANSI Standard A156.4. It is listed as such in the BHMA Certified Products Directory. For a cross reference of Norton Series 7500 Door Closers to ANSI/BHMA/Federal FF-H-121D or FF-H-121c Specifications, see the Specification Comparison Chart in the General Information Section of this Catalog. U.L. Listing All Norton Series 750017500BF Closets with non-hold-open arms are listed by Underwriters' Laboratories, Inc. for use on labeled fire doors. Available Finishes Sprayed Finishes -- All Norton Series 7500 Door Closers and Accessories are available in the following sprayed finishes. Order sprayed finishes by the Norton Symbol. Finish Norton BHMA f')escrh3tion Svrr~ol .~vmbol ('AlumL. um-' AL ,r:~:,/ Uull Bronze I.J'B *' 8~11 Plated finishes must be ordered by the Norton finish symbols listed. Where a matching of other door hardware finish is required, a sample finish chip must be submitted and approved, prior to order processing. Wood Finishes -- Series 7500W closers are available with steel covers with an unfinished wood lamination. The cover may be used unfinished, or it may be finished at the job site, along with the door and frame. These covers are available in the following fine-grained woods: Flat Cut Oak White Birch Teak Flat Cut Walnut Cherry Honduras Mahogany Contact the Norton Marketing , Department for the availability of' other wood grain laminates. Warranty The Series 7500 Door Closer is backed by a 10-year limited warranty. The aluminum shell is _w_arran_teed for the lifetime of the building in which it is originally installed. Suggested Specification Closets for interior (and) exterior doors shall be full rack-and- pinion type with cast aluminum alloy shell. Closer shall be surface-mounted and shall project no more than 2-1/8' from the surface of the door. Closer shall be non-handed to permit Dark Statuary Bronze STAT 690 Black 315 693 Gold GB 6,96 .To Complement Duranodic Medium Amber [ 312 I 694 Dark Amber 313 695 Black 315 693 Corrosion Inhibitor Prime Coat* [ SRI ~ 600 · Available at extra cost. Beige in color. Closets c~n be ordered pdme coated only, i.e. (SRI), or prime coated with finish coat, i.e. (SRI) x (DB). Plated Finishes -- Series 7500M closers with steel covers are available, at extra cost, in the following plated finishes: installation on doors of either hand. Hydraulic fluid shall be non-gumming, and non-freezing. Closer shall have multi-size spring power adjustment to permit setting of spring power_ from size (1 through 4} (2 through 6) with additional spring power available. Closer shall have two non-critiCal valves, hex-key-adjusted, to independently regulate sweep and latch speed. Closer shall have backcheck cushioning controlled by a hex-key-adjusted valve. Closer shall have backcheck-positioning controlled by a hex-key-adjusted valve. (Closer shall have adjustable delayed action closing controlled by a hex-key adjusted valve,) Regular Arm and Top Jamb closers shall have a non-hold-open shoe permitting a 15% (_+ 7-112%) power adjustment. Closer shall be enclosed in a (molded Finish Norton BHMA Description Symbol Symbol Bright Brass US3 632 Satin Brass US4 633 Bright Bronze US9 637 Satin Bronze US10 639 Oxidized Satin Bronze, US10B 640 Oil Rubbed Bright Nickel US14 645 Satin Nickel US15 646 Dark Oxidized US20A 650 Statuary Bronze Bright Chrome US26 651 Satin Chrome US26D 652 cover) (metal cover plated with a Norton finish) (metal cover laminated with an unfinished wood grain). Closets to be Norton Series (7500, 7500M, 7500W) (7500BF, 7500BF-M, 7500BF-W). 7500-3 Norton Series 7500 . Features Backcheck Cushioning Backcheck Position Regulating Valve ~Regulatin~ Valve Multi-Size Spring Adjustment Assembly / ~ .: Pinion Sweep Speed Regulating Valve / Latch Speed Regulating Valve / Sweep Speed Latch Speed \ / e' Optional: "DA" Adjustable Delayed Action Closing Regulating Valve Multi-Size Power: The closer spring Rack & Pinion Operation: Provides a assembly can be adjusted through a smooth transmission of po~er for wide power range. A high shouldered control of the door through its full adjustment nut accepts a standard 11/16" socket or wrench. Two Power Ranges: Each series can be adjusted through a range of sizes: Series 7500 Normal Power Range Closers, sizes 2 thru 6; Series 7500BF Accessibility Code Closets, sizes 1 thru 4. Tri-Style Installation: Versatile closer packaged with mounting hardware for regular arm and parallel arm installation. Closer can also be installed top jamb where frame face and reveal permit. Top jamb installation requires a minimum frame face of 3-1/4" (83 ram); arm will accommodate frame reveals of 0-3" (0-76 mm). See page 7500-7 for more details. Non-Handed: Pinion shaft extends vertically through the closer body in both directions. This permits the closer to be positioned on either right or left hand doors for all applications. Some options. as noted on page 7500-2, will require that the hand of the closer be specified. """'~Inum Alloy Shell: Series 7500 closer 3s are constructed of a special aluminum alloy, carefully selected to accommodate individual closer characteristics and operating conditions. opening and closing cycle. Adjustable Sweep Speed: An independent regulating valve, hex-key- operated, permits adjustment of the general closing speed. Adjustable Latch Speed: An independent regulating valve, hex-key-operated, permits adjustment of the door's speed for approximately the last 5° of the closing cycle. Adjustable Backcheck Cushioning: An independent regulating valve. hex-key- operated, provides an adjustable hydraulic cushion to the door opening speed toward the end of the opening cycle. Adjustable Backcheck Positioning: An independent valve, hex-key-operated, allows adjustment of the point, in the door's opening cycle, at which backcheck cushioning takes effect. It provides a range of 20 ° within which backcheck can be set. The exact range is dependent upon the arm application and templated position of the closer. Non-Critical Valves: All control valves for sweep speed/latch speed and backcheck control are non-critical and are adjusted by a standard 118" hex-key. Narrow Profile Arm: Series 7580 closers are suppiled wlth_a narrow profile arm for non-hold-open installations. It permits regular arm installation where the minimum ceiling clearance is 1' (25 ram) and the reveal does not exceed 118" (3 mm); it can be installed top jamb with a drop plate where the minimum top rail of the door is 3-518" (92 ram) and the frame reveal does not exceed 3" (76 ram); or it can be mounted parallel arm to raise the closer body 112" (13 mm) higher on the top rail of the door than the standard 7500 Series closets will permit Order Series 7580. Non-Hold-Open Arm: Standard closer will be supplied with a Non-Hold-Open arm. This arm is non-handed. Adjusta-Power Shoe: Supplied as standard for a 15% (-.- 7-1/2%) power adjustment by relocating the forearm at the shoe, for all regular arm and top jamb non-hold-open closets, only. Hold-Open Arm: Closer has adjustable hold-open feature (90' to 180°). This arm is non-handed. Order by suffixing "H" to the Catalog Number. Parallel RIgid Arm: Closer supplied with a heavy-duty rigid forearm for applications where heavy traffic, and heavy use are anticipated. Order by prefixlng "PR" to the Catalog Number. 75004 Features The Non-Hold-Open Parallel Rigid arm is non-handed. Also available with Hold- Open arm. Order by suffixing "H" to the Catalog Number. Hold-Open arms are handed. Molded cover:. Supplied as standard for all closers, this cover is fabricated of high impact UL listed material for covering the closer body and mounting screws. This cover is non-handed, and has cutout sections for top jamb application. Metal Cover. An optional cover available with either a plated or sprayed finish. This cover is non-handed except for top jamb installations since the shaft cutout must be factory prepared. Cover is attached to the Special Feature Closets Adjustable Delayed Action Closing: An optional hydraulic feature that adds a third speed range to the closing control cycle. This feature becomes effective when the door is opened and released at any point beyond 70°. This delayed closing enables traffic to clear the opening befor~ the normal Standard & Optional Arms Standard Arm: All Series 7500 (Regular Arm, Parallel Arm and Top Jamb) are supplied with a standard main arm which projects 1" (25 mm) from the mounting surface on the pinion. closer' body with screws; body must be factory drilled and tapped to accept these screws. Order Sedes 7500M dosera and specify hand of door for top jamb installations, Wood Laminated Cover. An optional metal cover that is laminated with fine-grained domestic or imported woods. It is supplied unfinished so it can be finished on the job with the door and frame. This cover is non-handed except for top jamb installations because the shaft cutout must be factory prepared. Cover is attached to the closer body with attaching screws; body must be factory ddlled and tapped to accept these screws. Order Series 7500W closing cycle starts. This feature is advantageous to the handicapped and elderly. It is also valuable for wheeled or other traffic where delayed closing is desirable. Backcheck cushioning and backcheck positioning are standard with all closers including closers with Adjustable Delayed Action Closing. Order Series 7500DA. Low Profile Arm: Series 7580 closers are supplied with a main arm which projects just 1/2" (13 ram) from the pinion mounting surface. Non-hold-open arms only. See Narrow Profile Arm features on the facing page for more details. Norton Series 7500 closere and specify hand of door for top jamb installations. Closer Adjustment Decah A decal is permanently affixed to the inside of the closer cover. This decal fully details all closer adjustments. Corrosion Resistant Closer. The shell, pinion bushing assembly and end caps of this closer are aluminum alloy materials. All other exposed components are of stainless steel, or zinc alloy materials to provide excellent resistance to corrosive environments. For standard non-hold-open applications only. Order Series 7500SS, P7500SS or J7500SS. Where hold-Open applications are desirable, Norton CloserPlus"' or Unitrole type controls with single-point hold-open are recommended. Refer to the Norton CloserPlusTM and Unitrole Door Controls catalog sections for complete details. For specific data concerning function and use of the Adjustable Delayed Action Closing feature, refer to page 7500-16. Hold-Open Arm: All Series 7500H closers are supplied with a hold-open telescoping arm. This arm is non-handed. Parallel Rigid Arm Series 750017500BF closers are available with a heavy-duty forearm for parallel arm applications where heavy traffic and heavy use are anticipated. Non-HoEd-Open Arm/Non,Handed Order PR75001PR7500BF Hold-Open Arm/Handed Order PR7500H x HandlPR7500BF-H x Hand Control Options Norton Series 7500,/7500BF Multi-Size Closers are the basic door control components for the following Norton Controls: Norton Unitrole Door Controls - integrates into a single unit a full feature heavy-duty door closer, a shock absorber and an auxiliary overhead door stop with or without selectable overhead door holder. Refer to the Unitrole Door Controls catalog section for complete details. Norton CloserPlus'= Door Controls - provides the control of a full featured heavy*duty door closer plus a positive overhead door stop with or without selectable hold-opeft. Refer to the CloserPlus"' Door Controls catalog section for complete details, 7500-5 TO: LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE ATTACHED ITEMS: Copies Spec Section Submittal No. LETTER OF TRANSMITTAL Date Attn: Re: IJob. No. 11/2/98 9802 Mr. Gary C. Henriticks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas Description 5 SC.8 12 Rolling Steel Door THESE ARE BEING TRANSMITTED: Information for Record O&M Data X Information for Engineer's Approval X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS / REMARKS: Please note that the model # for the specified door has changed from SFN-1 to Series 620. This is the same "Storm rite" as specified. Signed Joe Swinnea Wagon Wheel Ranch 1.5 MG Elevated Storage Tank City of Coppell, Texas Submittal No. Specification Section SC.8 Metal Rolling Service Door · Manufacturer: Size: Operation: Slats: Hood: Wind Load: Model: Overhead Door Corporation 12' X 12' ~bet, ic ow,.tor' 20 GA. Galvanized 24 GA. Galvanized Minimum 20psf. [] NO EXCEPTION TAKEN/j~AKE CORRECTIONS NOTED Overhead Series US~dIT SPECIFIED ITEM CheckinS is only for general Conformance with the design C,~nC,:'D~ Of '~he [-.'ro.'e.?t ~,n.'_-! FeneraI compliance with the in?orm:~:,m 7iv::~n in th;a contract documents. Any action sh~'w ~ i~ su',.~j~-'d to i:he requh'ements of the plans and spcc:,ficc;~ons. Ccntrc. c~or is re:pcnsibZe for: dimensions w[:~'h 2hi:tl be cc:~firRied and correlated at the job site; fab:ic:~2i:>n p'c~ce~:ies ~'nJ techniques of construction, cO- or,:ifnd~h n of hi:~ v'/or:.; wi;:h that of all other trades and perfoi-m~nB his work in a safe and satisfactory manner. SH~M2K, JACOBS & FINKLEA CONSULTING ENGINEERS DALES, TEXAS Corporation FEATURES · CUSTOM DESIGN All rolling service doors are computer designed to fit your specific requirements. )* COUNTERBALANCE The counterbalance is composed of helical torsion springs housed in a steel pipe barrel. The spring tension is readily adjusted with an accessible tension wheel. Spring assemblies are computer designed to effectively counterbalance the door for a standard 20,000 cycles. Optional high-cycle springs may be specified. ~'OPERATOR Overhead Door Corporation manufactures and computer matches its operators to the door's counterbalance system for precision operation and long life. Optional radio controls are available. ' · GUIDF..S Guides of structural steel angle or roll-formed design ensure smooth curtain operation. As an option, guide weatherstripping is available. · BO'i'rOM BAR The bottom bar is a reinforcing member that strengthens the curtain. As an option, it can be weatherstripped. On motor-operated doors, a sensing edge is also recommended. · CURTAIN The curtain consists of interlocking slats of curved or flat design, with endlocks to maintain alignment and windlocks as required to meet specified windloads. ~'SUPPORT BRACKE'TS Steel plate brackets support the curtain and counterbalance on sealed, self-aligning ball bearings. A stiffening steel fib on the bracket adds extra strength and supports the hood. · HOOD The hood shields the coiled curtain and counterbalance assembly against dust and premature wear of system parts. There are stiffening ribs at the top and bottom, with intermediate supports as required. As an added option, an internal hood baffle weatherstrip may be specified. -- Service Doors 08330/0VE BuyLine 4845 Service Door Selection Guide 'I'JLeEXANE : -~ ; , COIL-AWAY' ,S~:~C[ ' SEIVICE S814CE STOIIITrFF" $TOIglffi[m IRSllRT9 SmES, MODEL · :~ 60O, CAW 6ZS, Jn( aS, fiX Sle, FN 620, SF~ 6~,Um Common Projec~Tfi~es and Uses Light commercial, Commercial Commercial Zndus~al Indus~al, ~dustriai warehouse, , ~ -:* -i mini warehouse, & wa~housc, factory, wa~house, factory, warehouse, factory, warehouse, factory, factory, dis~budon economy projects up distribution cent, or, ' disb-ibudon center, distribution ccote~ dis~bucion center center, vehicle ma~n- ' ~ · '~ :' j ':" !' ! * ~ to ] 4' x 16' vehicle ma~tenance vehjcie maintenance vddc]c marcchance vehicle maintenance tea garage wRb'- : , ,::!.'~;,** ~ *" ~"* gErage, uptot6'x16' Frage up to16' x ]6' garage ' gage with insuhted. slSts&--! ;.~ j ) ..: ~ ~'-" stripping ~ight 30'0" max width 30'4" width 30'4" ' :(.. .. > '., : ·. bei ,t 30'0" , tl30' Operation .~-"'.:~' ";: ~ :!; TM Available push-up, V~Iabl= push-up, Available push-up; Avafiablo push-up, Available push-up, .Av' ' le push ' ;. WalI MoUntingC~}ndition Face-of-wail Fac~-of: all, .': Face-of-w , Facc..of-watl.- Face--of-wall, Fac~Lo w Windload Design "-.~: ~; None standard 20 l~3F ' - 20 F 20 PSF 20 PSF 20 PSF ' Weatherseals:; '.: ~'- , ' ~: · Bottom seal Bottom seal om seal, exterior Bottom seal Bottom seal, exterior Bottom' ' ' Is hood seals hood Curtain ' CAW C-187 C-187, C-275 F-265 F-26 d (see slat selector guide pg. 4) F-265 (fo e) Guide Types and Construction Galv. steel roll Roll Eormed Roll formed steel 3 st formed shapes for steel shapes or 3 shapes or 3 steel wi steel jambs & I angles for angles with weather- masonry wails arabs & seal for steel jambs alls & masonry walls Bottom Bar Design ~-~"~ l~xtruded aluminum Extruded aluminum Extruded aluminum Extruded aluminum Extruded aluminum 2 steel angles with with weatherseal or 2 galvanized steel or 2 galvanized steel or 2 steel angles with or 2 steel angles with weatherseat angles with weather- angles with weather- weatherseal weatherseal seal seal Optional features shown in italics. ~ J, :i. '~ i/ {.3../ Overhead Door Corporation offers the broadest array of rolling steel service ] J | J ' 7 light-duty Coil-Away*, Series 600, to our industrial StormtileTM insulated., Series ..t. ). I ~" .;., ~ 625, these doors provide long-lasting, · I j '. ' . ',. -" reliable service. We back all of our doors ~ i with unequaled engineering experience "i ~ .... ~,~.'.'. 7 ~" "." and the professional service of 400 / - ..=. Overhead Door distributors nationwide. * Clearance Details 08330/0VE BuyLine 4845 C ROLLING SERVICE DOORS SERIES 610, 615, 616, 620, 625 Hoist-Operated Doors 7' Series 6t0/620/625 Maximum dimensions' 91/2"' Series 815/616 9T/~" Series 615/616 101/2" Series 610/620 · 123/4~ Series 625 · Add 2" 10r electric operator 'Add T' 10r crank radius Add 4" 10r electric operator "9' w/3 angle guide with solely edge (series 615/616) GUIDE DETAILS SERIES 610, 620, 625 Face Mounted Service Doors over 15'4" 'Z" guides for concrete, masonry or wood jambs 1/4"-~.~_G~___.J "E' guides tor steel jambs Note: Guide weatherseat does not apL>l..y to'Series 610 doors. Face Mounted Service Doors to 15'4" 'Z" guides for concrete, "E" guides rot steel jambs masonry or wood jambs Note: Rolled guides do not apply to Series 625 doors. 01911i6 30'-- 16' t2' 10' 8' Dimension "A" Data: Series 610, 615, 616, 620, 625 Slat Series ..... To Determine Dimension ,. ooate bar it appropriate door series number and slat type 1. Locate door opening width at bottom of chart '~ L w h 3. Follow bar up to appropriate door ol:~ning height (shown at left) 4. Measurement designated within that bar section is Dimension "A" 5. For sizes exceeding those shown in chart consult your local Overhead Door distributor. Optional Between Jambs Mounting (Special Mounting Requirements) ] G + 3'* t b"-3'--'{ Motor &chain Push-up option · It RG operator with chain hoist, G + 6 3/4'. 'peralor must be top or lront ol hood mounted. · 'G" and "NI" Dimensions 610 & "G" 3:h" 4q~" 5sis'' 620 62S "M" 51/,'. 53/,'' 6~/';' 8'/," 8qZ' "G" and "M' dimensions shown are maximums Note for speci~er: The action of a windload on the curtain of a rolling door places loads on the door guides. The building jamb structure must be sufficient to accept these loads. A summary of the loads to be anticipated can be supplied as an option when specified. ' Architectural Specifications 08330/0VE BuyLine 4845 SERES 620 Not~ to Speci~er. This specification is a sug- gested guide. Available options are shown in (). PART 1 GENrERAL 1.01 Work Included The rolling doors shall be Series 620 as manufactured by Overhead Door Corporation. 1.02 Related Work Opening preparation, miscellaneous or structural metal work, access panels, finish or field painting, field electrical wiring, wire, conduit, fuses and disconnect switches are in the Scope of Work of other divisions or trades. PART 2 PRODUCT 2.01 Curtain Interlocking roll-formed slats as specified following. Endlocks shall be attached to each end of alternate slats to prevent lateral movemeaL Flat profile type F-265 for doors up to 18'4" wide, fabricated of 22 gauge gnlv~mized steel ~' (20 gauge galvanized steel)( I 8 gauge galv~mited stool)(22 gauge stainless steel)( 1B g,,,$e alumir. u,..). Flat profile type F 265 for doom botw~on lg'd" gah,,'~izosl ct.I (20 ga-g~ 0cainIcon otool)(18 g~v~o g-~ .... ;-ed ct,sl)( 1 t gauge ~ ~ uminum), Flat profile t/pe F 265 fat do~o bct~e~,~ 25'4" ~-cl ~30'4" vgid~, labfloated of Ig/,auge galv4minod 0t~ol ( i g gauge nlu..:au..)( 16 gauge g~ .... i'~ect cacti), 2.02 Bottom Bar Rxtruded aluminum up to l$"t" ,)/ido, Two creel ~nea-~ o,,er 15'4" wide, (Two galvanized ~ steel angles.) 2.03 Guides Guides shall be roll-formed steel shapes for openings up to 15'4" wide. On wider openings, guides shall be three (3) structural steel angles with a minimum thickness of 3/16". The guides shall be weatherstripped with a vinyl weatherseal at each jamb, on the exterior curtain side. (Interior cur,~;n fide ..... ,~,e,-~-ot ;, e~t!=.-.:!.; Guides shall be equipped with windlock bars as required to meet the minimum design windload of 20 PSF. (Cteat~' v, ir, dlo,~L, ~ a,,'til'~ble ~o optlone upon ttqua0t.) (Optional -e.},~de m~te~alc includ, ~luminum ~qct ct~jnle~v 2.04 Brackets Brackets shall be hot rolled steel plate to supporz the counterbalance, curtain and hood. (Galvanized steel plate is an option.) 2.05 Counterbalance The counterbalance shah be adjustable helical torsion springs housed in a steel tube or pipe barrel, suplxming the curtain with a deflection limited to .03" per foot of span [width]. Designed for standard 20,000 cycles. (~F:~c:.:! · cycle designs are available sueh as 50,000 or :~'Y2,~%2C~.) Counterbalance shall be adjustable by means of an adjustable tension wheel. 2.06 Hood The bocu:t sl~all be minimum 24 gauge galvanized steel. (I,Iea~ier steel gauges and Mnrninnr, e~r ~:rs~;nl,~¢~ [t~tI material -~ptie-"-~_!.) Intermediate supports shall be furnished to support the hood where required on wider openings. The hood shall be supplied with an internal hood baffle weatherseal. wenthe, s.~ls ~ optional.) 2.07 OReration M~nv~l F~oh up to 95 ~1- ft. or 12' X 8'. Above 12' X 8' operation shall be manual chain hoist. eOptioeal :..mar and m~'dt el~atatioa.) Manual push up doors shall have interior slide bolts, suitable for padlocking by others. Manual chain hoist operated doors shall have elmin keeperlocks suitable for padlocking by others. (Cylinder locks a~ optional. Maaufa~mr~r's v'~^~4~l cylinder ms7 he fu..iahed hy othe. ~.) · . Galvanized Steel: Slats and hood shall be galvanized steel in accordance with ASTM A 525 and receive rust-inhibitive, roll coating process, including bondcrazing. 0.2 mils thick baked-on prime paint, and 0.6 mils thick baked- on polyester (powder c~at-d) top east. Non- galvanized expos~xt fen'ous surfaces shall receive one coat of rust-inhibitive primer. C, tainlc_u ~teel; Slau and hood shall ha ot. ainl~3~ ~t.l with (~ mill ~nich)(Ng, ~ cmin finish). Aluminum: ~latt ~nd h~d ehall b~ aluminkx-.. with (mill ~ni~h)(cl .... ~aized ~nioh)(bronae . :~netH?~.el finlob) PART 3 EXECUTION 3.01 The 620 Series service doors shall be installed in accordance with Overhead Door Corporation instructions and standards. Installation will be by authorized Overhead Door Corporation representatives. LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 TO: Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE ATTACHED ITEMS: Copies Spec Section Submittal No. LETTER OF TRANSMITTAL Date Attn: Re: IJob. No. 11/4/98 9802 Mr. Gary C. HendrickS, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas Description 5 Sht. 16 13 Backflow Preventer THESE ARE BEING TRANSMITTED: Information for Record O&M Data X Information for Engineers Approval X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS / REMARKS: Signed ~ ~///~ Joe Swinnea GLA-VA[ S~E~. 5~c~- ~ - MODEL DC6L Double Check Backflow Preventer Sizes 3/4" - 1" - 11/2"-2" Installation Model DC6L Double Check Backflow Preventers should be installed with adequate clearance and easy accessibility for testing and maintenance and must by protected from freezing. The assembly may be installed horizontally or vertically with flow up. Refer to local codes for specific installation require- ments, Some codes may prohibit vertical installation. Thermal water expansion and/or water hammer down stream of the back'flow proventar can cause excessive pressure. Excessive pressure situations should be eliminated to avoid possible damage to the system and assembly. Side View Protective Enclosure Water Meter 12" Min. ,',~ ~'e~- f Suggested .~' ~'; .' ~'-~r;.,~ .....!-,' ~ i~' ::.~:~ ,~ , ~. ~;~ · ~ · Low Head Loss · Documented Flow Curves · All Internal Parts are Serviceable Inline · Meets Specifications of AWWA, ASSE, and the Foundation for Cross Connection Control and Hydraulic Research the University of Southern California · Bronze Bodies, Caps, Shutoff Valves and Testcocks. The CLA-VAL Model DC6L Double Check Valve Assembly is a reliable means of backflow protection for non-toxic service. The assembly is carefully constructed of corrosion resisting materials. It consists of one body containing two independently acting spring-loaded check valves, two ball valves and four test cocks. Field testing is easily performed by means of the test cocks provided for this purpose. The Y-type check valves are uniquely designed to provide drip- tight closure against reverse flow, and low pressure drop at maximum capacity. The spring-loaded check-valves cause the valve to seal against an inlet pressure higher than the outlet pressure when there is no flow. Typical Applications Double Check assemblies are used to prevent backflow of pollutants that are objectionable but not toxic. Double checks may be installed under continuous pressure service and may be subjected to back pressure. Double Checks can be used in sprinkler irrigation systems, fire protection without chemical additives, protection of industrial plants, industrial in-plant plumbing systems and other systems requiring protection. Local codes may vary. Consult author- ities for specific approved applications. Material Specifications Maximum working pressure Hydrostatic test pressure Temperature Range Fluid · End Detail Main Valve Body Elastomer Spdngs ' On water systems that experience an excess of a constant 140°F. assembly must be ordered wit~ HW (OC7L 1" HW) ' Can be furnished with optional silicone seat discs for areas subject to chlorine degradation ot rubber pans. 175 psi 350 psi 32°F to 180°F' Water Threaded ANSI B2.1 Bronze ASTM B584-78 Nitdte ASTM D-2000 seat discs' Stainless steel, 300 sedes CLA-VAL' Dimensions (In inches) and Weights (In Ibs.) Net Wt. A SIze A B C D E 3/'4 11 3/8 6 7/8 3 3/4 3 3,/4 2 1/2 7 l" B 11/2 177/8 101/4 51/8 47/8 33/8 171/2 =,~ 2 18 5/8 10 1/4 5 1/8 4 7/8 3 3/8 20 ..,-~. ~ (METRIC - ram.) _ (g) 9 3 25 327.0 953 63.5 3.4 EE 30 1302 7.9 t 73.1 260.4 130.2 123.8 85~ Flow Curves Row curves as established by the Founda~on for Cross Connec'don Control and Hydraulic Research at the University of Southern California, 10 20 30 (GPr~u-*. 10 ~ 30 40 ~ ~' ~ ' '- ,~ 6 , ~ 10 15 20 (FPS) 2" ~ :' "' ':: ' ' ':' '::' " ' .... '.:: :': :' 0 ~ 80 ~ 160 ~ 2~ (G~M) 6 ~ 10 15 ~ (FPS) FLOW RATE (in GPM and ~S) NO~S: 1. Vel~ities are ~lculated for flows in Sch~ule ~ st~l pipe. 2. Typi~l ~ter system flow vel~es of 0 to 7.5 ~s ~ould ~ ~ for head Io~ efficien~ compad~ns. Agency Compliance · ASSE Listed 1015 · AWWA C506 Conformance · CSA B-64.5 Certified The Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California* ' Valves must be supplied with resilient seated s~ut-off valves and test cocks. Typical Specifications The Double Check Valve assembly 3/4" through 2" shall consist of a bronze body with bronze caps. The body shall be a "Y" pattom design incorporating two spring loaded, center guided check assemblies. The assembly shall include threaded inlet and outlet, full port ball valve shut-off valves and four ball valve test cocks. All intemal parts shall be of corrosion resis- tant mateddais. All Double Check Valves shall be constructed so all intemal parts can be serviced without removing the assembly from the line. Seat discs shall be reversible. The assembly shall operate when installed in any position. Double Check Valves Shall be rated to 175 psi MVV~NP and water temperature from 32°F to 1400E The assembly shall meet the requirements of ASSE Standard 1015, AWWA Standard C506-78, and USC Foundation for Cross Connection Control and Hydraulic Research, Latest Edition. The Double Check Assembly shall be a CLA-VAL DC6L or approved equal. CLA-VA[ E-DCGL (R-10/95) CLA-VAL CO. P o Box 1325 Newport Beach CA 92659-0325 Phone: 714-722-4800 · Fax: 714-548-5441 CLA-VAL CANADA LTD. 4687 Chnstie Drive Beamsvie, Ontario Canada L0R 194 Phone: 905-563-4963 Fax: 905-563-4040 CLA-VAL SA Chemin des Mesanges 1 CH-1032 Romanel/ Lausanne. Swilzedand Phone:41-21-643-15-55 Fax: 41-21-643-15-50 Represented By: LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 TO: Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 LETTER OF TRANSMITTAL Date Attn: Re: lJob. No. 11/2/98 9802 Mr. Gary C. Henddcks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas WE ARE SENDING YOU THE A'R'ACHED ITEMS: Copies Spec Section Submittal No. 5 Sht. 16 14 Backflow Prevenl THESE ARE BEING TRANSMITTED: Information for Record O&M Data X Description ,~NO EXCEPTION TAKEN [] MAKE CORRECTIONS NOTED e )f22] SU,3MIT SPECIFIED ITEM Chr/:!,:inr~ iE c:::y fc,,-!~-:ner-~fi conforlT.~nce with the design or,no .~ ,:v:' ':-:: ~r,::~?~ ~:nd ~x,zmernl compliance ,2,'~th the ~q'{', ,: :~:': -:~ ":1 [: :5~ c,-~:~:~{:.-~: .!On!JFleF~t::. f.F'.y action sh ,:,':,' ~ .:h,.-c::, ~c: :~e r-:':;t;"z~'%~;-:~n of the plans and ~p:.":' :':':: :. (,~.':"c,:::~ ~3 :,'_ :nn:~:;~e for: dimensions v/h~: .~;::~ ::e conFhnk:d ~nd ,-:r',r,-s',2~ed at the job site; ord:,n?i; ,ri ,:~ ~'f:5 wgfk w:~:~ {~ of aH oLhel' trades and perforlning I':i:: ,',"~r~,'. in a 5;:4,9 add sn-LZc:'/~',:zc!-y manner, q -4 MFK jACOBS & FINKLEA UUI'~bULI II'~b LINbli~jLLb:5 DALLAS, I LXAS Information for Engineer°s Approval X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below, EXCEPTIONS / REMARKS: Please note that we propose to paint the Junction Box Lid per the city's standard details. The lid is not available with a galvanized option. Signed ~ ~ /--,. Joe Swinnea ,..)u.t,,,tCT iraf'd BDX /" 1,185# OPENING SIZE OR CAST IRON RING & COVER AS REQUIRED lay CUSTOMER %~C,, ~ 6 J 4 0 BOI'FO~ SECTION 4.8~5~ EXTENSIONS · O ' 1,040 PER/FT. K.O PER JO~3' REQUIRE EN M T 1. CONCRETE: 4000 PSI 2. REINF.: GRADE 60 ,.'3. H-20 LOADING · 4.. MAX. PIPE SIZE 30" I.O.R.C.P. .,5. EXTENSION SECTIONS AVAILABLE /o, ?--' 4"¢ ,,C,c>- CC-/~T~'R 'Z '-d' f-Ro'-'~, b~ ',"',/RL',.. 'g. p.,. !?. ~'J 0, 3'-0"x3'--Erx~'-6". STANDARD JUNCTION "BOX W/VARIABLE HEIGHTS A~nerican Indushrial Pre-Cast Products, Inc. P.O. BOX 394 ALVAP,.ADO, TEXAS 76QQ9. ME'FRO: 817-.4.77-5286 501 EAST BAXTER SEGUIN, TEXAS 78155 210-401-:0555 It walk Floor, Vau , and SideDoors "Single Leaf Steel SPECIFICATIONS: Type Q. Floor access door snail be Type Q. size .~ as manufactured by The Bilco Company. Angle frame shall be 1/4' (6.35mm} steel with anchors welded to the exterior. Door leaf shall be 1/4' (6.35mm) steel diamond pattern plate to withstand a live load of 150 lb/ft2 (732 kg/mz) with a maximum allowable deflection of 1/150th of the span. Cast steel cam- action hinges shall be bolted to the underside and shall pivot on torsion bars for smooth, easy and controlled door operation throughout the entire arc ol opening and closing. Operation Shall not be affected by temperature. Door shall open to 90 degrees and lock automatically in that position. A vinyl grip handle shall be provided to release the cover for closing, A Type 316 stain- less steel snap lock and removable turn handle shall be provided. Hardware shall be zinr ptntPd nnd chromate sealed. Factory fin- Manufacturer shall guarantee against defects in material or workmanship for a period of five years. STANDARD SIZES AND WEIGHTS SIZE Type Width x Length Material Q-1 2'0" x 2'0' (610mm x 610mm) Steel Q-2 2'6" x 2'6" (762mm x 762turn) Steel Q-3 2'6' x 3'0"/762mm x 914mrn) Steel Q-4 3'0" x 3'0' (91 4mmx 914rnm) Steel QD-I' 4'0" x 2'6' (1219mm x 762rnrn) Steel Type Q Wt. Ib (kg) 11 o (5o) 160 (73) 185 (84) 210 (95) 275 (125) "TER & TRD" si.g! Double Leaf Aluminum Pan-Ty! 1 "(25.4mm) deep pan for terrazzo, cer e, brick payors and many other fioori .~riais. SPECIFICATIONS: Type TER, Type TR[ iccess door shall be Type ~ as manufactured by The Bilco 1' (25.4mm) fillable pan to receive {specify fill material and wet e shall be I/4' (6.35mm) shall be 1/4' (6.35mm) aluminum plate reinforced num stiffenors as required. shaft be equiDped with hea~ continuous tel hinges and shall have compression spring operators for easy opeBtion. Door to nine~ degrees and lock automatically in that position. A vinyl grip handle s to release the cover for closing. Door(s) s~all be built to withstand a live b/~2 (732 kg/m2}, and equipped with a snap Fock and removable handle. Alumi~ I be mill finish, with b~tuminous coating applied to the exterior of the frame; 'or. Hardware shall be zinc plated and chromate sealed'. ~allation shall be in m~nufacturer's instructions. Manufacturer shall guaran- ~nst defects ip for a period of five years. conditions, when so specified, TER and TRD are available with stainl lrdware ~hroughout. (See Floor, Vault, and Sidewalk Door Options). Type TER-1 TER-2 TER-3 TER-4 TER-5 TRD-2 TRD-3 TRD-4 · "'~_',.,-~ SIZE Wt. ~..Width x Length Ib (kg) 2'0" x'~.610ram x 610rnrn) 100 (45) 2'6" x 2'6""~ x 762mm) 110 (50) 3'0"x2'6"(914~x 62mrn) 120 (54) 3'0" x 3'0" (914rnrn%x' ~lm) 130 (59) 3'6" x 34'60" ' , 5'o"x '" --: 19 LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 TO: Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE ATTACHED ITEMS: LETTER OF TRANSMITTAL Date Attn: Re: 11/2/98 IJ°b' N%802 Mr. Gary C. Hendricks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas Copies Spec Section Submittal No. Description 5 Sht. 5 15 Wall Feed Plates and Boots THESE ARE BEING TRANSMITTED: Information for Record ~ O&M Data X Information for Engineer's Approval X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in com~ll~~tPhEt~Q~lTt~ld~lJlt~ttORRECTlONS NOTED including plans and specifications as modified by addenda, cha 'g~E~Pagelgsc~/ii[I field orders.[~,ft~iVlSE AND RESUBMIT exceptions to the contract documents are noted below. ! [] SUGMET SPECIFIED ITEM EXCEPTIONS / REMARKS: Chqc!,-im~ is cnty for r:'ner;,~ ccnformance with the design ~ c{::;.:'. ' "; :;.' :-:':/'% :.:;~ .f>;-lurn! ccmpqnnc& wi~-h the [D'C: :': ,r~ Y:'.."~ ~: i[:: 'c',~'F,~,:[' ~::2. r'U;7'C~',~. ;~Y ~C~iOR st?:::.; ~: ~L'. '~ >~ ':::: ~2c;L.;:' ::j"'.:S Of 'L':2e p;~mS and f'P'--:.::'~::.:::::. C::'::,; :...':_:i['-: ~:":'~:'~:>7- for: Ji.nensiOnS wh~,:h rh: s~ ~._- :.:?.:>:~>:-~:::r?,:j :_< r,c::~':~?.d n~ the job site; fab~'>:: ::>a p ., -:.,:,:z ~:r,d>J.:h:::,:?3s of cOns'L~uc:h~n, co- ord~n&;:_~i-~ or :'~[~: Wc:jk %jth th~'L' Of aj~ o~he;- fi',"~das and performing h:.. ,?.';-rk in a safe and sat~sfi:c:o;v R1JrlBer. , CONSULTING ENGINEERS DALLAS. TEXAS Signed ~ ~/~ Joe Sw/nnea A B C D Multiple Entrance Wall/Roof Feed- Thru Plate opening Distance Plumber of Height Width Center to Center Type Openings in (mm) in (mm) in (mm) No. 4" (102 ram) Entry Opening, Multiple Entrance Plate 1 7 (178) 7 (178) - 204673-1 1 5 (127) 5 (127) - 204673-2 4 9.5 (241) 25.5 (648) 5.5 (139) 204673-4 8 17.5 (444) 25.5 (648) 5.5 (139) 204673-8 12 25.5 (648) 25.5 (648) 5.5 (139) 204673-12 5" (127 ram) Entry Opening, Multiple Entrance Plate 1 9.5 (241) 9.5 (241) - 48940-1 2 9.5 (241) 17.5 (444) 7 (178) 48940-2 3 9.5 (241) 25.5 (648) 7 (178) 48940-3 ,,_. 4 17.5 (444) 17.5 (444) 7 (178) 48940-4 6 17.5 (444) 25.5 (648) 7 (178) 48940-6 -,~ 566 A'~NDREW, Wall Entry Systems 'lldntrancuesrnce WaI~R~ QiMultiple Entrance Wall/Roof Feed Thru Plate. Plate with one or more 4 or 5 inch entry holes. Use with the corresponding size rubber cable boots (sold separately). (2~Rubber Cable Boot. Use with above feed-thru plate, with the corresponding size entry hole. rrestorPort PlusTM Integrated Wall Entry/Groun ' em. Wall entry and grounding system in on con of a polycarbonate entry panel an olid copper nd bar assembly with asse hardware, a eize corrosion inhibitor therstripping and weatherpro aling caps for try ports. Use with Arrestor Plus e arres (order separately, see page 562) and ca cushions (sold separately, see table o age). E Polycarbonate E nventional Installations. the same durable pol Port Plus for instal requi as Customer Service Center - Call toll-free from: · U.S.A., Canada and Mexico 1-800-255-1479 Wall/Roof Feed Thru Assembly, Single Entrance Cable Size 1/2" 5/8" 7/8" ~.~,. 1-5/8" 2-1/4" 3" 4" 5" Cable Entry Cushions Type Number 40656A-3 40656A-7 40656A-1 40656A-2 40656A-6 40394-2 40394-1 33938-5 Number of Type Number Cable Size Holes in Cushions WC4-3 1/2" 3 WC5-3 7/8" 3 WC6-1 1-1/4" 1 WC7-1 1-5/6" 1 WC12-1 2-1/4" 1 Ground Bar Assembly Only Used On APPORT-14-2 APPORT-22-2 APPORT-23-2 APPORT-24-3 APPORT-26-4 APPORT-34-3 APPORT-36-4 APPORT-38-5 HELIAX® Coaxial Cables Wall/Roof Feed Thru Boots Cable Cable Boot Number of Size Type No. Holes in Boots 4" (102 ram) Cable Boots 1/2" Foam 204679-5 1 1/2' Foam 204679-7 3 1/2" Air 204679-6 1 1/2" Air 204679-1 3 5/8" 204679-13 1 5/8" 204679-14 3 7/8" 204679-2 1 1 - 1/4" 204679-3 1 1-5/8" 204679-4 1 2-1/4" 204679-8 1 3" 204679-9 1 5" (127 mm) Cable Boots 1/2' Foam 48939-6 1 1/2" Foam 48939-8 3 1/2' Air 48939-7 1 Type Number 1/2" Air 48939-5 3 GBA-14-2 5/8" 48939-14 1 GBA-22-2 5/8" 48939-15 3 7/8" 4Q,939-.1 1 GBA-23-2 ~7/8" ~ 48939-2 '~ 3 G BA-24-3 - - G BA-26-4 1 - 1/4" 48939-3 I GBA-34-3 1-5/8" 48939-4 1 G BA-36-4 2-1/4" 48939-9 1 GBA-38-5 3" 48939-10 1 ArrestorPort-Plus'" Integrated Entry IilTi~e/Ground Systems Surge Arrestor Ports q'l~Jilion Type Horizontal Vertical qi1~ry Number Rows Columns APPORT-14-2 1 4 2 APPORT-22-2 2 2 2 APPORT-23-2 2 3 ~ APPORT-24-3 2 4 ~1 APPORT-26-4 2 6 ,- APPORT-34-3 3 4 t4 A P PO RT-36-4 3 6 ., APPORT-38-5 3 8 ;, Panel Wall Opening Width Height Width Height in (ram) in (mm) in (mm) in (mm) 20.5 (520) 16 (405) 15.25 (390) 11.25 (285) '1-5 (380) 22 (560) 9.75 (250) 17.125 (435) 15 (380) 22 (560) 10.75 (275) 16.875 (430) 20 (510) 22 (560) 15.25 (385) 17,125 (435) 26,5 (675) 22 (560) 21,75 (550) 17.25 (440) 20 (510) 28 (710) 15.25 (385) 23.25 (590) 26,5 (675) 28 (710) 21.75 (550) 23.25 (590) 32 (815) 28 (710) 27.25 (690) 23.25 (590) Polycarbonate Entry Panel for C.,lt~,z~.,nal Installations Hole Pattern Panel Wall Opening Type Horizontal Vertical Width Height Width Height Number Rows Columns in (mm) in (ram) in (mm) in (ram) STPORT-14 1 4 26.5 (675) 10.5 (265) STPORT-22 2 2 15.5 (395) 16 (405) STPORT-23 2 3 20.5 (520) 16 (405) STPORT-24 2 4 26.5 (675) 16 (405) STPORT-26 2 6 37.5 (955) 16 (405) STPORT-34 3 4 26.5 (675) 21.5 (545) STPORT-36 3 8 37.5 (955) 21.5 (545) STPORT-46 4 6 37.5 (955) 27 (685) · U.K. 0800-250055 - Republic of Ireland 1-800-535358 · Australia !:[e:0-803 219 · New Zealand 0800-441-747 21.75 (550) 5.75 (145) 10.75 (275) 11.25 (285) 16.25 (413) 11.25 (285) 21.75 (550) 11 (280) 32.75 (830) 11.25 (285) 21.75 (550) 16.75 (425) 32.75 (830) 16.75 (425) 32.75 (830) 22.25 (565) 567 TO: LANDMARK STRUCTURES, INC. 1665 Harmon Road Fort Worth, Texas 76177 (817) 439-8888 Fax (817) 439-9001 Shimek, Jacobs & Finklea 8333 Douglas Avenue, Suite 820 Dallas, Texas 75225 WE ARE SENDING YOU THE ATTACHED ITEMS: LETTER OF TRANSMITTAL Date Attn: Re: 11/2/98 JJob. No~)802 Mr. Gary C. Hendricks, P.E. Wagon Wheel Ranch 2.0 MG Elevated Storage Tank Bid No. Q 0198-03 City of Coppell, Texas Copies Spec Section Submittal No. Descdption 5 SC.8 17 THESE ARE BEING TRANSMITTED: Information for Record O&M Data Welding Procedures / Welder Certification '~N0 EXCEPTION TAKEN [] MAKE CORRECTIONS NOTED [] REJECTED [] REVISE AND RESUBMIT [~ SUBMIT SPECIFIED ITEM Chec~:h3F= is on'..v fc,' .,.7?nGra! conformance with the design c~>nc:~.,; of [:h'- h'~c-::: :jE~ :::~;::.~:al cornp~i,?nce wifh the into~::.:L'cn ,':E,,~ :1 h, ~1 ,-::,,t ; .-: d:,::~:ments, Any action sh:,v;': ~: f~,~::~ ,-.: ;.:~ ~-:.::~.~:-- .-:,:,:::-~ of ~he p~ans and sp:c:c[;~::~':ort~:. (x , t:,':": ; ,,. ::,.;::[ ~'fie 1-or: di;nensions wil-h :'h::~ ',u ~,,.::~ ~ &;C: C~;:C::t~f?~ at t~,a job site; performing h~ vvDr',< in a s~:~e and SaLI~T.::;C:GrV Fredrotor- S~:-~,/~LZK, JACOBS & FtNKLEA CONSULTING ENGINEERS DALES, TEXAS X Return 2 Copies CERTIFICATION: This information has been reviewed and determined to be in compliance with the contract documents Including plans and specifications as modified by addenda, change orders and field orders. Any exceptions to the contract documents are noted below. EXCEPTIONS / REMARKS: Signed Joe Swinnea ,LANDMARK STEEL INC. 817/439-8888 1665 Harmon Road Fort Worth, Texas 76177 WPS No. Revision No. Welding Process Supporting PQR No. Joint Detail WELDING PROCEDURE SPECIFICATION LSI- 1 Date Oct, 3, 1995 n/a Date n/a SMAW Type Manual LSI - 1.1 , LSI- 1.2 1. t > .375" Bevel at joint to be total 45 +/- 15 degrees for a 1/4" +/- 1/8" land. t < or = .375" joint is square groove, 2. Wider gaps up to 314" require buttering each side until closure meets this tolerance. A36 backing plate may be used on wide gaps. Remove backing prior to welding second side. 3. Root pass may be run up or down with E6010. 4. Cover or wash pass may be run up or down with E7018. 5. Grind and/or arc gouge to sound metal for 100% penetration. JOINTS (QW-402) Joint Design See Detail Backing Wide gaps only Backing Material A36 if req'd for wide gaps onlV BASE METALS (QW-403) ~ P#I, Group¢~l to Pffl, Group#l . nickness Range 3116'" to 11/2" Pipe Dia. Range '~ 2~-" to 60" Other FILLER METALS (QW-404) Spec. No.(SFA) 5.1/5.5 5.1/5.5 AWS No. E7018 E6010 F No. 4 3 A No. 1 1 Electrode Dia. 1/8to7/32 1/8to7/32 Filler Dia. Not required Not required Electrode Flux(Class) " " Consumable Insert .... Other " " 'POSITION (QW405) Position of Groove Position of Fillet Welding Progression Other 1 G, 2G, 3G, 4G 1 G, 2G, 3G, 4G E7018 up, E6010 down A,~-c"~01a11~ Process SMAW ~ (No'tes 1,3,4.,5 J~l/8 +/- 1/i6 No~e ~ POSTWELD H EAT TREATMENT (QW-407) Temperature Time Range Other " GAS (QW-408) Shielding Gas Not required % Composition " Flow Rate " Gas Backing " TECHNIQUE (QW-410) String/Weave Bead Oriface/gas cup size . I n itial/I nterpass clean Method back gouge Oscillation Cont. tube to work gap Mult.lsingle pass Mult./single electrode Travel Speed (Range) Peening PREHEAT (QW-406) Preheat Temp. 50F Interpass Temp.-Min. 5OF Interpass Temp.-Max. 500F Preheat Maintenance n/a ELECTRICAL CHARACTERISTICS (QW-409) Diameter Weld layers Type polarity Amp. Range Volt Range 1/8 - 7/32 Multiple DC/Reverse 130-200 22-30 Not required Either n/a Grind and/or brush Grind and/or arc gouge n/a n/a Multiple Single Manual No Travel Speed Positions Manual All E7018 SMAW 1/8 - 7/32 Multiple DC/Reverse 130-210 22-30 Manual All LANDMARK STEEL INC. 817/439-8888 1665 Harmon Road Fort Worth, Texas 76177 PQR No. LS I - 1.1 WPS NO. LSI - 1 Revision No. n/a Welding Process SMAW Joint Detail PROCEDURE QUAUF1CATION RECORD Date Oct. 3, 1995 Date Oct. 3, 1995 Date n/a Type Manual 1. Plate thickness: t = .75" 2. Bevel: Angle = 45 degrees with 1/8 land. 3. Alignment tacks and root pass E6010 ~ /~ (]3o, ckgouge I No~es ].-3 ' I ' 5/3;~ JOINTS (QW-402) Joint Design See Detail Backing Not required Backinq Material n/a BASE METALS (QW-403) P#1, Group#1 to P#I, Group#1 )~ess 3/4" A36 Plate Pipe Dia. Range 24" to 60" Other ' FILLER METALS (QW-404) Spec. No.(SFA) 5.1/5.5 AWS No. E7018 F No. 4 A No. 1 Electrode Dia. 5 / 3 2" Filler Dia. Not required Ele, ctrode Flux(Class) " Consumable Insert Other " POSITION (QW-405) Position of Groove Position of Fillet Welding Progression 5.1/5.5~' E6010 3 1 5/32" Not required 3G n/a E7018 up, E6010 (root) down E7018 down on wash pass only AW_.~Iall~ Process Diameter SMAW 5/32 · E7018 SMAW 5~32' Time Range Other " GAS (QW-408) Shielding Gas Not required % Composition " Flow Rate " Gas Backing " TECHNIQUE (QW-410) String/Weave Bead Oriface/gas cup size Initial/lnterpass clean Method back gouge Oscillation Cont. tube to work gap MultJsingle pass Mult./single electrode Travel Speed (Range) Peening PREHEAT (QW-406) Preheat Temp. None Interpass Temp.-Min. 50F Interpass Temp.-Max. 500F Preheat Maintenance n/a POSTWELD HEAT TREATMENT (QW-407) Temperature Not required ELECTRICAL CHARACTERISTICS (QW409) Weld layers Type poladty Amp. Range Volt Range Single DC/Reverse 140-160 26-28 Multiple DC/Reverse 140 -170 23 -25 Weave n/a Grind and brush Arc gouge n/a n/a Multiple Single Manual No Travel Speed Positions Manual 3G Manual 3G LAND'MARK STEEL INC. 81'7/439-8888 1665 Harmon Road Fort Worth, Texas 76177 PQH No. WPS NO. Revision No. Wedding Process Joint Detail PROCEDURE QUAUFICATION RECORD LSI- 1.2 Date Oct. 3, 1995 LSI ~ 1 Date Oct. 3, 1995 n/a Date nla SMAW Type Manual 1. Plate thickness: t = .75" 2. Bevel: Angle = 45 degrees with 1/8 land. 3. Alignment tacks and root pass E6010 JOINTS (QW-402) Joint Design Backing Backinq Material BASE METALS (QW-403) See Detail Not required n/a r ,~, ~ia. Range 24" to 60" Other -~. FILLER METALS (QW-404) Spec. No.(SFA) 5.1/5.5 AWS No. "' ET018 F No. 4- A No. 1 Electrode Oia. 5 / 3 2" Filler Dia. Not required Electrode Flux(Class) - Consumable Insert " Other - P~I, Group#l to P#I, Group#1 314" A36 Plate POSITION (QW-405) Position of Groove Position of Fillet Welding Progression 5.1/5.5-- E6010 3 1 5/32" Not required 4G n/a E7018 Up, E6010 (root) down AWS Class Process Diameter "'~""10 SMAW 5/32" E/d18 SMAW 5/32" POSTWELD HEAT TREATMENT {QW-407) Temperature Not required Time Range ' Other GAS (QW-408) Shielding Gas. Not required % Composition " Flow Rate " Gas Backinq TECHNIQUE {QW-410) String/Weave Bead Offface/gas cup size Initial/Interpass clean Method back gouge Oscillation Cent. tube to work gap Mult./single pass Mult./single electrode Travel Speed (Range) Peeninq PREHEAT (QW-406) Proheat Tamp. None Interpass Temp.-Min. 50F Interpass Temp.-Max. 500 F Proheat Maintenance n/a ELECTRICAL CHARACTERISTICS (QW-409) Weld layers Type polarity Amp. Range Volt Range Single OC/Reverse 140-160 26-28 Multiple OC/Reverse 140 -170 23-25 Weave n/a Grind and brush Arc gouge n/a n/a Multiple Single Manual No Travel Speed Positions Manual 4G Manual 4G LANDMARK STEEL INC. 817~439-8888 1665 Harmon Rd. Ft. Worth, TX 76177 MANUFACTURE'S RECORD OF WELDING OPERATOR QUALIFICATION TEST Welder's Name: Chds Burns Welding Process: SMAW Type: Manual In Accordance With Welding Procedure Specificatjon 0NPS): LSI-1 Backing (QW-402): None Base Matedal Welded (QW-403): A36 Plate Thickness: .75" The above welder is qualified for the following ranges: Vadable Process Process Type Backing (QW-402) Matedal Spec. (QW-403) Thickness- Groove.~ - Fillet Filler Matedal (QW-404) - Spec. No. - Class - F Number Position (QW-405) Weld Progression (QW-410) Gas Type (QW-408) Electrical Characteristics (QW-409) - Current - Potadty Actual Values Used In Qualification SMAW Manual None P1 to P1 None A5.1 E7018 F4 4G, 3G Uphill N.A. D.C. Reverse Range Qualified SMAW Manual None P1 to P1 t< 1.5" Unlimited A5.1 E7018 F4, F3, F2, F1 4G, 3G, 2G, 1G Uphill and Downhill N.A. D.C. or A.C. Reverse - N.A. for A.C. RADIOGRAPHIC TEST RESULTS (QW-304 & QW-306) Radiographic Results: Passed Per QW 191.2 Test Conducted by: Centur~ Inspection Inc. Test No.: 98-242 Test Date: May 26, 1998 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the requirements of 2:ctions~~ Organization: Landmark Steel Inc. . ~ "'LANDMARK STEEL INC. 817/439-8888 1665 Harmon Rd. Ft. Worth, TX 76177 MANUFACTURE'S RECORD OF WELDING OPERATOR QUALIFICATION TEST Welders Name: Paul Wolfe Welding Process: SMAW Type: Manual In Accordance With Welding Procedure Specification (WPS): LSI-1 Backing (QW-402): None Base Material Welded (QW-403): A36 Plate Thickness: .75" The above welder is qualified for the following ranges: Variable Process Process Type ,Backing (QW-402) I~terial Spec. (QW-403) Thickness - Groove - Fillet Filler Material (QW-404) - Spec. No. - Class - F Number Position (QWo405) Weld Progression (QW-410) Gas Type (QW-408) Electrical Characteristics (QW-409) -Current - Poladty Actual Values Used In Qualification SMAW Manual None P1 to P1 .75" None A5.1 ET018 F4 4G, 3G Uphill N.A. D.C. Reverse Range Qualified SMAW Manual None P1 to P1 t<1.5" Unlimited A5.1 E7018 F4, F3, F2, F1 4G, 3G, 2G, 1G Uphill and Downhill N.A. D.C. or A.C. Reverse - N.A. for A.C. RADIOGRAPHIC TEST RESULTS {QW-304 & QW-306) Radiographic Results: Passed Per QW 191.2 Test Conducted by: MQS Inspection Inc. Test No.: 96-609 Test Date: Dec. 9, 1996 We certify that the statements in this record are correct and that the test welds were ared, requirements of Sections IX of the . "'[:ganization: Landmark Steel Inc. By: LANDMARK STEEL INC. 817/439-8888 1665 Harmon Rd. Ft. Worth, TX 76177 MANUFACTURES RECORD OF WELDING OPERATOR QUALIFICATION TEST Welder's Name: Juan Talamantez Welding Process: SMAW Type: In Accordance With Welding Procedure Specification (WPS): Backing (QW402): None Base Matedal Welded (QW403): A36 Plate Manual LSI-1 Thickness: .75" The above welder is qualified for the following ranges: Vadable Process Process Type Backing (QW-402) Material Spec. (QW-403) Thickness- Groove ~ - Fillet Filler Material (QW-404) - Spec. No. - Class - F Number Position (QW-405) Weld Progression (QW-410) Gas Type (QW-408) Electrical Characteristics (QW-409)- Current - Polarity Actual Values Used In Qualification 'SMAW Manual None P1 to P1 None A5.1 E7018 F4 4G, 3G Uphill N.A. D.C. Reverse Range Qualified SMAW Manual None P1 to P1 t< 1.5" Unlimited A5.1 E7018 F4, F3, F2, F1 4G, 3G, 2G, 1G Uphill and Downhill N.A. D.C. or A.C. Reverse - N .A. for A.C. RADIOGRAPHIC TEST RESULTS (QW-304 & QW-306) Radiographic Results: Passed Per QW 191.2 Test Conducted by: Century Inspection Inc. Test No.: 98-320 Test Date: July 16, 1998 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the requirements of Sections IX of the ASME Code. Organizationi Landmark Steel Inc. By: ,~~ LANDMARK STEEL INC. 1665 Harmon Rd. Ft. Worth, TX 76177 MANUFACTURE'S RECORD OF WELDING OPERATOR QUALIFICATION TEST 'I' Welder's Name: Paul Williams Welding Process: SMAW Type: Manual In Accordance With Welding Procedure Specification (WPS): LSI-1 Backing (QW-402): None Base Matedal Welded (QW-403): A36 Plate Thickness: .75" The above welder is qualified for the following ranges: Vadable Process Process Type Backing (QW-402) 'Material Spec. (QW-403) Thickness- Groove. - Fillet Filler Matedal (QW-404) - Spec. No. - Class - F Number Position (QW405) Weld Progression (QW-41 O) Gas Type (QW408) Electrical Characteristics (QW409) - Current - Poladty Actual Values Used In Qualification SMAW Manual None P1 to P1 .75" None A5.1 E7018 F4 4G, 3G Uphill N.A. D.C. Reverse Range Qualified SMAW Manual None P1 to P1 t< 1.5" Unlimited A5.1 E7018 F4, F3, F2, F1 4G0 3G, 2G, 1G Uphill and Downhill N.A. D.C. or A.C. Reverse - N.A. for A.C. RADIOGRAPHIC TEST RESULTS (QW-304 & QW-306) Radiographic Results: Passed Per QW 191.2 Test Conducted by: Century Inspection Inc. Test No.: 98-242 Test Date: Apdl 26, 1998 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the requirements of Sections IX of the ASME Code. Organization: Landmark Steel Inc. By: !' I LANDMARK STEEL INC. 817/439-8888 1665 Harmoh Rd. Ft. Worth, TX 76177 MANUFACTURE'S RECORD OF WELDING OPERATOR QUALIFICATION TEST Welder's Name: Chad Upshaw Welding Process: SMAW Type: Manual In Accordance With Welding Procedure Specification (WPS): LSI-1 Backing (QW-402): None Base Matedal Welded (QW-403): A36 Plate Thickness: .75" The above welder is qualified for the following ranges: Vadable Process Process Type Backing (QW-402) Material Spec. (QW-403) Thickness- Groove. - Fillet Filler Material (QW-404) - Spec. No. - Class - F Number Position (QW-405) Weld Progression (QW-410) Gas Type (QW-408) Electrical Characteristics (QW-409) - Current - Poladty Actual Values Used In Qualification SMAW Manual None P1 to P1 None A5.1 E7018 F4 4G, 3G Uphill N.A. D.C. Reverse Range Qualified SMAW Manual None P1 to P1 t<1.5" Unlimited A5.1 E7018 F4, F3, F2, F1 4G, 3G, 2G, 1G Uphill and Downhill N.A. D.C. or A.C. Reverse- N.A. for A.C. RADIOGRAPHIC TEST RESULTS (QW-304 & QW-306) Radiographic Results: Passed Per QW 191.2 Test Conducted by: Century Inspection Inc. Test No.: 98-100 Test Date: March 19, 1998 We certify that the statements in this record are correct and that the test welds were prepared, of Sections I f the ASME Code. welded and tested in accordance with the requirementsns I f the~ Organization: Landmark Steel Inc. By: LANDMARK STEEL 817/439-8888 INC. 1665 Harmon Rd. Ft. Worth, TX 76177 MANUFACTURE'S RECORD OF WELDING OPERATOR QUALIFICATION TEST Welder's Name: Chuck Koehne Welding Process: SMAW Type: In Accordance With Welding Procedure Specificatjon (WPS): Backing (QW-402): None Base Matedal Welded (QW-403): A36 Plate Manual LSI~I Thickness: .75" The above welder is qualified for the following ranges: Vadable ~rocess Process Type Backing (QW-402) Matedal Spec. (QW-403) Thickness - Groove - Fillet Filler Matedal (QW-404)- Spec. No. - Class - F Number Position (QW-405) We'jd Progression (QW-410) Gas Type (QW408) Electrical Characteristics (QW-409)- Current - Poladty Actual Values Used In Qualification SMAW Manual None P1 to P1 None A5.1 E7018 F4 4G, 3G Uphill N.A. D.C. Reverse Range Qualified S MAW Manual None P1 to P1 t<1.5" Unlimited A5.1 E7018 F4, F3, F2, F1 4G, 3G, 2G, 1G Uphill and Downhill N.A. D.C. or A.C. Reverse - N.A. for A.C. RADIOGRAPHIC TEST RESULTS (QW-304 & QW-306) Radiographic Results: Passed Per QW 191.2 Test Conducted by: Century Inspection Inc. Test No.: 98-100 Test Date: March 19, 1998 We certify that the statements in this record are correct and that the test welds were prepared, welded and tested in accordance with the requirements of Sections IX of the ASME Code. Organization: Landmark Steel Inc. By: ~