Loading...
ST9505-LR 950614 (2)Hooper Engineering Laboratories, Inc. Geotechnical Engineering · Construction Materials Testing CONCRETE MIX DESIGN CLIENT: L.H. Lacy Date: 14 June 1995 PROJECT: Executive Drive Coppell, Tx DESIGN SPECIFICATIONS: Per Client 28 DAY STRENGTH: 3000 PSi CEMENT CONTENT: 5.00 SACKS, Type 1 SLUMP: 3.0 "+/- 1" AGGREGATE SIZE: 1.5 "Gr. St. - Pioneer ADMIXTURE: ASTM C494 and C260 5.00 SKS. TOTAL CEMENT[TIOUS MATERIAL Mix No. I MATERIALS WEIGHTS # ABS. VOL. I Cu Yd 1Cu Yd SSD CF Cement ASTM C150 Fly Ash ASTM C618 Coarse Agg. 1.5" Cr. St. Coarse Agg. 3/8" P. G. Fine Agg. 0-#4 Water Admixture ASTM C494 Admixture ASTM C260 % Air 3.15 470 2.391 2.67 0 0.000 2.59 1825 11.292 2.63 0 0.000 2.60 1356 8.360 1.00 242 29.0 3.877 18.8 oz* 0.000 4.00 2.4 oz* 1.080 0.00 0.000 entrapped air Total Weight * OR AS RECOMMENDED BY SUPPLIER 3893 27.000 Fresh Unit Weight #/cf Water Cement Ratio #/# 144.2 0.515 5.81 gal /sack NOTE: ASTM C-94 Standard Specifications For Ready Mix Concrete "When the concrete strength is used as a basis for acceptance, the manufacturer shall be entitled to copies of test reports." "The individual who samples and tests concrete---shall have demonstrated the knowledge and ability---for Certification, ACI Level I." To assist in the quality control/quality assurance of your mix, provide reports on a timely basis.9~ ~Z. ~ 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419 Hooper Engineering Laboratories, Inc. Geotechnical Engineering · Construction Materials Testing CONCRETE MIX DESIGN CLIENT: L.H. Lacy Date: 14 June 1995 PROJECT: Executive Drive Coppell, Tx DESIGN SPECIFICATIONS: Per Client 28 DAY STRENGTH: 3000 PSI CEMENT CONTENT: 6.00 SACKS, Type t SLUMP: 5.0 "+/- l" AGGREGATE SIZE: 1.5 "Ct. St. - Pioneer ADMIXTURE: ASTM C494 and C260 6.00 SKS. TOTAL CEMENTITIOUS MATERIAL Mix No. 2 - Hand Work MATERIALS WEIGHTS # ABS. VOL. [ Cu Yd ! Cu Yd SSD CF Cement ASTM C150 Fly Ash ASTM C618 Coarse Agg. 1.5" Cr. St. Coarse Agg. 3/8" P. G. Fine Agg. 0-#4 Water Admixture ASTM C494 Admixture ASTM 0260 [ Air 3.I5 564 2.869 2.67 0 0.000 2.59 1775 I0.983 2.63 0 0.000 2.60 1287 7.933 1.00 258 31.0 4.135 22.6 oz* 0.000 4.00 2.8 oz* 1.080 0.00 0.000 entrapped air Total Weight ' OR AS RECOMMENDED BY SUPPLIER 3884 27.000 Fresh Unit Weight #/cf Water Cement Ratio #t# 143.9 0.457 5.16 gal /sack NOTE: ASTM C-94 Standard Specifications for Ready Mix Concrete "When the concrete strength is used as a basis for acceptance, the manufacturer shall be entitled to copies of test reports." "The individual who samples and tests concrete---shall have demonstrated the knowledge and ability---For Certification, ACI Level [." To assist in the quality control/quality assurance of your mix, provide reports on a timely basis. 2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351.6419