ST9505-LR 950614 (2)Hooper Engineering Laboratories, Inc.
Geotechnical Engineering · Construction Materials Testing
CONCRETE MIX DESIGN
CLIENT: L.H. Lacy
Date: 14 June 1995
PROJECT: Executive Drive Coppell, Tx
DESIGN SPECIFICATIONS: Per Client
28 DAY STRENGTH: 3000 PSi
CEMENT CONTENT: 5.00 SACKS, Type 1
SLUMP: 3.0 "+/- 1"
AGGREGATE SIZE: 1.5 "Gr. St. - Pioneer
ADMIXTURE: ASTM C494 and C260
5.00 SKS. TOTAL CEMENT[TIOUS MATERIAL
Mix No. I
MATERIALS
WEIGHTS # ABS. VOL.
I Cu Yd 1Cu Yd
SSD CF
Cement ASTM C150
Fly Ash ASTM C618
Coarse Agg. 1.5" Cr. St.
Coarse Agg. 3/8" P. G.
Fine Agg. 0-#4
Water
Admixture ASTM C494
Admixture ASTM C260 % Air
3.15 470 2.391
2.67 0 0.000
2.59 1825 11.292
2.63 0 0.000
2.60 1356 8.360
1.00 242 29.0 3.877
18.8 oz* 0.000
4.00 2.4 oz* 1.080
0.00 0.000
entrapped air
Total Weight
* OR AS RECOMMENDED BY SUPPLIER
3893 27.000
Fresh Unit Weight #/cf
Water Cement Ratio #/#
144.2
0.515 5.81 gal /sack
NOTE: ASTM C-94 Standard Specifications For Ready Mix Concrete
"When the concrete strength is used as a basis for acceptance,
the manufacturer shall be entitled to copies of test reports."
"The individual who samples and tests concrete---shall have
demonstrated the knowledge and ability---for Certification,
ACI Level I."
To assist in the quality control/quality assurance of your mix,
provide reports on a timely basis.9~ ~Z. ~
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351-6419
Hooper Engineering Laboratories, Inc.
Geotechnical Engineering · Construction Materials Testing
CONCRETE MIX DESIGN
CLIENT: L.H. Lacy
Date: 14 June 1995
PROJECT: Executive Drive Coppell, Tx
DESIGN SPECIFICATIONS: Per Client
28 DAY STRENGTH: 3000 PSI
CEMENT CONTENT: 6.00 SACKS, Type t
SLUMP: 5.0 "+/- l"
AGGREGATE SIZE: 1.5 "Ct. St. - Pioneer
ADMIXTURE: ASTM C494 and C260
6.00 SKS. TOTAL CEMENTITIOUS MATERIAL
Mix No. 2 - Hand Work
MATERIALS
WEIGHTS # ABS. VOL.
[ Cu Yd ! Cu Yd
SSD CF
Cement ASTM C150
Fly Ash ASTM C618
Coarse Agg. 1.5" Cr. St.
Coarse Agg. 3/8" P. G.
Fine Agg. 0-#4
Water
Admixture ASTM C494
Admixture ASTM 0260 [ Air
3.I5 564 2.869
2.67 0 0.000
2.59 1775 I0.983
2.63 0 0.000
2.60 1287 7.933
1.00 258 31.0 4.135
22.6 oz* 0.000
4.00 2.8 oz* 1.080
0.00 0.000
entrapped air
Total Weight
' OR AS RECOMMENDED BY SUPPLIER
3884 27.000
Fresh Unit Weight #/cf
Water Cement Ratio #t#
143.9
0.457 5.16 gal /sack
NOTE: ASTM C-94 Standard Specifications for Ready Mix Concrete
"When the concrete strength is used as a basis for acceptance,
the manufacturer shall be entitled to copies of test reports."
"The individual who samples and tests concrete---shall have
demonstrated the knowledge and ability---For Certification,
ACI Level [."
To assist in the quality control/quality assurance of your mix,
provide reports on a timely basis.
2870 Walnut Hill Lane Dallas, Texas 75229 (214) 351.6419