ST9505-LR 950517 (2)Hooper
Engineering Laboratories,
Construction Materials Testing
Inc.
REPORT OF LIME SERIES
CLIENT: Prentiss Properties
DATE: 17 May 1995
PROJECT: Executive Drive, Coppell, TX
JOB NO.: 95.1053
SAMPLES: Taken by a representative of Hooper Engineering Laboratories, Inc. on 5/17/95.
LIQUID LINEAR PLASTICITY
CLASSIFICATION LIMIT SHRINKAGE INDEX
1)
2)
NOTE:
Executive Drive, Station 10 + 50
Brown clay 41.9
6% Lime added 38.0
8% Lime added 37.0
10% Lime added 35.4
14.0 27.5
4.6 10.3
4.5 10.1
4.1 9.4
Executive Drive
Dark grey clay 52.4 18.4 37.0
6% Lime added 52.9 7.3 14.9
8% Lime added 52.7 7.3 14.8
10% Lime added 50.2 6.3 13.1
Recommendation for 7% lime @ 6" depth - 32.0 lbs. per sq. yd.
This number should not be considered as a specified amount, rather an amount that
we feel would be required to reduce the plasticity index using normal work effort,
under realistic conditions.
TECHNICIAN:
DISTRIBUTION:
,,~.
LS/CDJ
(1) Prentiss Properties, Tom Navin
(1) L. H. Lac~ Company
{1} CiW of Co~pell En~ineerin~ De~t.