TCEQ Investigation Sec 3 pg 174-269
Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test.-Total Solids by Method 254OG L411486 Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -01 Sample Date:7 1812009 Extraction Date:7 1912009 Analysis Date:7 11312009 11:13:00 AM Instrument ID: BAL Analyst. Analytic Batch: WG430721 EPA ID: TN00003 Method Blank Analyte CAS Results Total Solids 0.000 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Total Solids 50.0 50.0 100 85- 115 Quality Control Summary for client sample(s) S13- 01 -2FT 32 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Total Solids by Method 2540G Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No.-L411486 Sample Number: L411486 -02, -08, -03, -05, -09, -06, -04, -07 Sample Date:7 1812009 Extraction Date:7 1912009 Analysis Date:7 11312009 11:07:00 AM Instrument ID: BAL L411486 Analyst :469 Analytic Batch: WG430722 EPA ID: TN00003 Method Blank Analyte CAS Results Total Solids 0.000 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Total Solids 50.0 50.0 100.0 85 - 115 Quality Control Summary for client sample(s) SB -02 -2FT, S13-08 -1 OFT, SB -03 -2FT, SB -05 -1 OFT, SB -09 -LOFT, SB -06 -LOFT, SB -04 -1 OFT, S13- 07 -8FT 33 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Total Solids by Method 254OG L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No. Sample Number.-L411486-01 Sample Date.-71812009 Extraction Date:7 1912009 Analysis Date:7 11312009 11:13:00 AM Instrument ID: BAL Analyst: 469 Analytic Batch: WG430721 EPA ID: TN00003 Sample Duplicate L411486 -01 Sample Results Name Results Duplicate %RPD Limit Qualifiers Total Solids 81.0 81.1 0.1 5 Quality Control Summary for client sample(s) SB- OI -2FT 34 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Total Solids by Method 2540G Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number.-L411486-02, -08, -03, -05, -09, -06, -04, -07 Sample Date.-71812009 Extraction Date.-71912009 Analysis Date: 7 /13/2009 11:07:00 AM Instrument ID: BAL L411486 Analyst: 469 Analytic Batch: WG430722 EPA ID: TN00003 Sample Duplicate L411491 -02 Sample Results Name Results Duplicate %RPD Limit Qualifiers Total Solids 86.9 85.4 1.8 Quality Control Summary for client sample(s) SB -02 -2FT, S13-08 -1 OFT, SB -03 -2FT, S13-05-1 OFT, S13-09 -1 OFT, SB -06 -LOFT, SB -04 -1 OFT, SB- 07 -8FT 35 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Mercury by Method 7471 L411486 Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No.-L411486 Sample Number: L411486 -04, -06 Sample Date:7 1812009 Extraction Date:7 1912009 Analysis Date:7 11212009 9:04:00 PM Instrument ID: CVAA3 Analyst: 448 Analytic Batch: WG430718 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL Mercury Laboratory Control Sample (LCS) <0.020 <0.0025 Quality Control Summary for client sample(s) SB -04 -1 OFT, SB- 06 -1 OFT 36 of 69 True Recovery Control Analyte Value Found % Limits Qualifiers Mercury 8.77 8.21 93.6 71.6-127.7 Quality Control Summary for client sample(s) SB -04 -1 OFT, SB- 06 -1 OFT 36 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Mercury by Method 7471 L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -04, -06 Sample Date :7 1812009 Extraction Date :7 1912009 Analysis Date :7 11212009 9:04:00 PM Instrument ID: CVAA3 Analyst: 448 Analytic Batch: WG430718 EPA ID: TN00003 Sample Duplicate L411484 -01 Sample Results Name Results Duplicate %RPD Limit Qualifiers Mercury 0.000 0.000 Matrix Spike /Matrix Spike Duplicate L411484 -01 Quality Control Summary for client sample(s) SB -04 -1 OFT, SB -06 -1 OFT 37 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Mercury 0.250 0.000 0.235 94.0 0.235 94.0 70 -130 0.0 20 Quality Control Summary for client sample(s) SB -04 -1 OFT, SB -06 -1 OFT 37 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Trace Metals by Method 6010B L411486 Matrix: Soil - mg /kg Project :Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -04, -06 Sample Date:7 1812009 Extraction Date:711012009 Analysis Date. Instrument ID: ICP6 Analyst. Analvtic Batch: WG430873 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL Arsenic 7440 -38 -2 <1.00 <0.271 Barium 7440 -39 -3 <0.250 <0.0536 Cadmium 7440 -43 -9 <0.250 <0.0371 Chromium 7440 -47 -3 <0.500 <0.0986 Lead 7439 -92 -1 <0.250 0.120 Selenium 7782 -49 -2 <1.00 <0.327 Silver 7440 -22 -4 <0.500 <0.163 Laboratory Control Sample (LCS) Quality Control Summary for client sample(s) SB -04 -I OFT, SB -06 -I OFT 38 of 69 True Recovery Control Analyte Value Found % Limits Qualifiers Arsenic 192 182 94.8 78.6-120.8 Barium 420 421 100 78.8- 121.4 Cadmium 70.1 67.0 95.6 78.5 -121.5 Chromium 168 173 103 80.4-120.2 Lead 113 110 97.3 77.3 - 122.1 Selenium 176 166 94.3 75.6- 125 Silver 115 113 98.3 66- 133.9 Quality Control Summary for client sample(s) SB -04 -I OFT, SB -06 -I OFT 38 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test.-Trace Metals by Method 6010B L411486 Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -04, -06 Sample Date. Extraction Date:7110 12009 Analysis Date:7 11112009 Instrument ID: ICP6 Analyst: 265 Analytic Batch: WG430873 EPA ID: TN00003 Sample Duplicate L411634 -29 Sample Results Name Results Duplicate %RPD Limit Qualifiers Arsenic 5.74 5.94 3.4 20 Barium 75.1 74.7 0.5 20 Cadmium 0.0000 0.0252 MS Rec Chromium 13.9 13.5 2.9 20 Lead 17.0 18.0 5.7 20 Selenium 0.0000 0.0000 3.6 20 Silver 0.0000 0.0000 122 94.6 Matrix Spike /Matrix Spike Duplicate L411634 -29 Quality Control Summary for client sample(s) SB -04 -1 OFT, SB -06 -LOFT 39 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Arsenic 50.0 5.94 52.5 93.1 54.4 96.9 75 -125 3.6 20 Barium 50.0 74.7 122 94.6 123 96.6 75 -125 0.8 20 Cadmium 50.0 0.0000 44.2 88.4 48.0 96.0 75 -125 8.2 20 Chromium 50.0 13.5 59.7 92.4 62.2 97.4 75 -125 4.1 20 Lead 50.0 18.0 67.2 98.4 66.2 96.4 75 -125 1.5 20 Selenium 50.0 0.0000 44.9 89.8 53.1 106 75 -125 17 20 Silver 50.0 0.0000 45.5 91.0 49.1 98.2 75 -125 7.6 20 Quality Control Summary for client sample(s) SB -04 -1 OFT, SB -06 -LOFT 39 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Volatile Organic Compounds by Method 8260B L411486 Matrix.-Soil - mg/kg Project: Coppell Auto Center Project No. - 940.002 Login No.- L411486 Sample Number: L411486 -02 Sample Date:7 1812009 Extraction Date:7 11412009 Analysis Date:7 11512009 5:42:00 AM Instrument ID: VOCMS 1 Analyst: 140 Analytic Batch: WG431272 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL 65 -128 Ethylbenzene 0.050 0.046 Benzene 71 -43 -2 <0.001 <0.0003 Ethylbenzene 100 -41 -4 <0.001 <0.0002 Methyl tert-butyl ether 1634 -04 -4 <0.001 <0.0003 Toluene 108 -88 -3 <0.005 <0.0012 Xylenes, Total 1330 -20 -7 <0.003 <0.0005 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Benzene 0.050 0.047 94.2 65 -128 Ethylbenzene 0.050 0.046 91.7 74- 128 Methyl tert-butyl ether 0.050 0.047 93.0 44- 148 Toluene 0.050 0.047 93.1 70- 120 Xylenes, Total 0.150 0.141 94.2 74- 127 Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers Benzene 0.050 0.044 87.6 65- 128 Ethylbenzene 0.050 0.044 87.3 74- 128 Methyl tert-butyl ether 0.050 0.044 87.8 44- 148 Toluene 0.050 0.045 89.1 70- 120 Xylenes, Total 0.150 0.136 90.5 74- 127 Quality Control Summary for client sample(s) S13- 02 -217T 40 of 69 M Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No.-L411486 Sample Number: L411486 -04 Sample Date:7 1812009 Extraction Date:7 11412009 Analysis Date:7 11412009 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL 1, 1, 1,2-Tetrachloroethane 630 -20 -6 <0.001 <0.0002 1, 1, 1 -Trichloroethane 71 -55 -6 <0.001 <0.0005 1,1,2,2 - Tetrachloroethane 79 -34 -5 <0.001 <0.0003 1,1,2 - Trichloroethane 79 -00 -5 <0.001 <0.0005 1,1,2 - Trichloro- 1,2,2 - trifluoroethane 76 -13 -1 <0.001 <0.0002 1, 1 -Dichloroethane 75 -34 -3 <0.001 <0.0003 1, 1 -Dichloroethene 75 -35 -4 <0.001 <0.0007 1, 1 -Dichloropropene 563 -58 -6 <0.001 <0.0003 1,2,3 - Trichlorobenzene 87 -61 -6 <0.001 <0.0002 1,2,3 - Trichloropropane 96 -18 -4 <0.001 <0.0007 1,2,3 - Trimethylbenzene 526 -73 -8 <0.001 <0.0002 1,2,4 - Trichlorobenzene 120 -82 -1 <0.001 <0.0002 1,2,4 - Trimethylbenzene 95 -63 -6 <0.001 <0.0002 1,2- Dibromo -3- Chloropropane 96 -12 -8 <0.005 <0.0012 1,2- Dibromoethane 106 -93 -4 <0.001 <0.0003 1,2- Dichlorobenzene 95 -50 -1 <0.001 <0.0002 1,2- Dichloroethane 107 -06 -2 <0.001 <0.0005 1,2- Dichloropropane 78 -87 -5 <0.001 <0.0008 1,3,5- Trimethylbenzene 108 -67 -8 <0.001 <0.0002 1,3- Dichlorobenzene 541 -73 -1 <0.001 <0.0004 1,3- Dichloropropane 142 -28 -9 <0.001 <0.0003 1,4- Dichlorobenzene 106 -46 -7 <0.001 <0.0002 2,2- Dichloropropane 594 -20 -7 <0.001 <0.0006 2- Butanone (MEK) 78 -93 -3 <0.010 <0.0027 2- Chloroethyl vinyl ether 110 -75 -8 <0.001 <0.0033 2- Chlorotoluene 95 -49 -8 <0.001 <0.0002 4- Chlorotoluene 106 -43 -4 <0.001 <0.0003 4- Methyl -2- pentanone (MIBK) 108 -10 -1 <0.010 <0.0014 Acetone 67 -64 -1 <0.050 <0.0170 Acrylonitrile 107 -13 -1 <0.010 <0.0020 Benzene 71 -43 -2 <0.001 <0.0003 Bromobenzene 108 -86 -1 <0.001 <0.0002 Bromodichloromethane 75 -27 -4 <0.001 <0.0004 Bromoform 75 -25 -2 <0.001 <0.0006 Quality Control Summary for client sample(s) SB -04 -1 OFT 41 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No. Login No.-L411486 Sample Number: L411486 -04 Sample Date: 7/8/2009 Extraction Date:7 11412009 Analysis Date:7 11412009 10:06:00 PM Instrument ID: VOCMS6 Analyst:167 Analytic Batch: WG431385 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL Bromomethane 74 -83 -9 <0.005 <0.0013 Carbon tetrachloride 56 -23 -5 <0.001 <0.0003 Chlorobenzene 108 -90 -7 <0.001 <0.0002 Chlorodibromomethane 124 -48 -1 <0.001 <0.0002 Chloroethane 75 -00 -3 <0.005 <0.0006 Chloroform 67 -66 -3 <0.005 <0.0004 Chloromethane 74 -87 -3 <0.001 <0.0006 cis -1,2- Dichloroethene 156 -59 -2 <0.001 <0.0007 cis -1,3- Dichloropropene 10061 -01 -5 <0.001 <0.0003 Di- isopropyl ether 108 -20 -3 <0.001 <0.0003 Dibromomethane 74 -95 -3 <0.001 <0.0003 Dichlorodifluoromethane 75 -71 -8 <0.005 <0.0003 Etylbenzene 100 -41 -4 <0.001 <0.0002 Hexachloro -1,3- butadiene 87 -68 -3 <0.001 <0.0004 Isopropylbenzene 98 -82 -8 <0.001 <0.0002 Methyl tert-butyl ether 1634 -04 -4 <0.001 <0.0003 Methylene Chloride 75 -09 -2 <0.005 <0.0006 n- Butylbenzene 104 -51 -8 <0.001 <0.0002 n- Propylbenzene 103 -65 -1 <0.001 <0.0002 Naphthalene 91 -20 -3 <0.005 <0.0004 p- Isopropyltoluene 99 -87 -6 <0.001 <0.0002 sec - Butylbenzene 135 -98 -8 <0.001 <0.0002 Styrene 100 -42 -5 <0.001 <0.0002 tert- Butylbenzene 98 -06 -6 <0.001 <0.0002 Tetrachloroethene 127 -18 -4 <0.001 <0.0002 Toluene 108 -88 -3 <0.005 <0.0012 trans -1,2- Dichloroethene 156 -60 -5 <0.001 <0.0007 trans -1,3- Dichloropropene 10061 -02 -6 <0.001 <0.0004 Trichloroethene 79 -01 -6 <0.001 <0.0003 Trichlorofluoromethane 75 -69 -4 <0.005 <0.0003 Vinyl chloride 75 -01 -4 <0.001 <0.0003 Xylenes, Total 1330 -20 -7 <0.003 <0.0005 Quality Control Summary for client sample(s) SB -04 -1 OFT 42 of 69 m Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No.-L411486 Sample Number: L411486 -06 Sample Date:7 1812009 Extraction Date:7 11512009 Analysis Date:711512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL 1, 1, 1,2-Tetrachloroethane 630 -20 -6 <0.001 <0.0002 1, 1, 1 -Trichloroethane 71 -55 -6 <0.001 <0.0005 1,1,2,2 - Tetrachloroethane 79 -34 -5 <0.001 <0.0003 1,1,2 - Trichloroethane 79 -00 -5 <0.001 <0.0005 1,1,2 - Trichloro- 1,2,2- trifluoroethane 76 -13 -1 <0.001 <0.0002 1, 1 -Dichloroethane 75 -34 -3 <0.001 <0.0003 1,1- Dichloroethene 75 -35 -4 <0.001 <0.0007 1, 1 -Dichloropropene 563 -58 -6 <0.001 <0.0003 1,2,3 - Trichlorobenzene 87 -61 -6 <0.001 <0.0002 1,2,3 - Trichloropropane 96 -18 -4 <0.001 <0.0007 1,2,3 - Trimethylbenzene 526 -73 -8 <0.001 <0.0002 1,2,4 - Trichlorobenzene 120 -82 -1 <0.00I <0.0002 1,2,4 - Trimethylbenzene 95 -63 -6 <0.001 <0.0002 1,2- Dibromo -3- Chloropropane 96 -12 -8 <0.005 <0.0012 1,2- Dibromoethane 106 -93 -4 <0.001 <0.0003 1,2- Dichlorobenzene 95 -50 -1 <0.001 <0.0002 1,2- Dichloroethane 107 -06 -2 <0.001 <0.0005 1,2- Dichloropropane 78 -87 -5 <0.001 <0.0008 1,3,5- Trimethylbenzene 108 -67 -8 <0.001 <0.0002 1,3- Dichlorobenzene 541 -73 -1 <0.001 <0.0004 1,3- Dichloropropane 142 -28 -9 <0.001 <0.0003 1,4- Dichlorobenzene 106 -46 -7 <0.001 <0.0002 2,2- Dichloropropane 594 -20 -7 <0.001 <0.0006 2- Butanone (MEK) 78 -93 -3 <0.010 <0.0027 2- Chloroethyl vinyl ether 110 -75 -8 <0.001 <0.0033 2- Chlorotoluene 95 -49 -8 <0.001 <0.0002 4- Chlorotoluene 106 -43 -4 <0.001 <0.0003 4- Methyl -2- pentanone (MIBK) 108 -10 -1 <0.010 <0.0014 Acetone 67 -64 -1 <0.050 <0.0170 Acrylonitrile 107 -13 -1 <0.010 <0.0020 Benzene 71 -43 -2 <0.001 <0.0003 Bromobenzene 108 -86 -1 <0.001 <0.0002 Bromodichloromethane 75 -27 -4 <0.001 <0.0004 Bromoform 75 -25 -2 <0.001 <0.0006 Quality Control Summary for client sample(s) S13-06 -1 OFT 43 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -06 Sample Date: 71812009 Extraction Date:711512009 Analysis Date:7 11512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst:140 Analytic Batch: WG431498 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL Bromomethane 74 -83 -9 <0.005 <0.0013 Carbon tetrachloride 56 -23 -5 <0.001 <0.0003 Chlorobenzene 108 -90 -7 <0.001 <0.0002 Chlorodibromomethane 124 -48 -1 <0.001 <0.0002 Chloroethane 75 -00 -3 <0.005 <0.0006 Chloroform 67 -66 -3 <0.005 <0.0004 Chloromethane 74 -87 -3 <0.001 <0.0006 cis -1,2- Dichloroethene 156 -59 -2 <0.001 <0.0007 cis -1,3- Dichloropropene 10061 -01 -5 <0.001 <0.0003 Di- isopropyl ether 108 -20 -3 <0.001 <0.0003 Dibromomethane 74 -95 -3 <0.001 <0.0003 Dichlorodifluoromethane 75 -71 -8 <0.005 <0.0003 Ethylbenzene 100 -41 -4 <0.001 <0.0002 Hexachloro -1,3- butadiene 87 -68 -3 <0.001 <0.0004 Isopropylbenzene 98 -82 -8 <0.001 <0.0002 Methyl tert-butyl ether 1634 -04 -4 <0.001 <0.0003 Methylene Chloride 75 -09 -2 <0.005 <0.0006 n- Butylbenzene 104 -51 -8 <0.001 <0.0002 n- Propylbenzene 103 -65 -1 <0.001 <0.0002 Naphthalene 91 -20 -3 <0.005 <0.0004 p- Isopropyltoluene 99 -87 -6 <0.001 <0.0002 sec - Butylbenzene 135 -98 -8 <0.001 <0.0002 Styrene 100 -42 -5 <0.001 <0.0002 tert- Butylbenzene 98 -06 -6 <0.001 <0.0002 Tetrachloroethene 127 -18 -4 <0.001 <0.0002 Toluene 108 -88 -3 <0.005 <0.0012 trans -1,2- Dichloroethene 156 -60 -5 <0.001 <0.0007 trans -1,3- Dichloropropene 10061 -02 -6 <0.001 <0.0004 Trichloroethene 79 -01 -6 <0.001 <0.0003 Trichlorofluoromethane 75 -69 -4 <0.005 <0.0003 Vinyl chloride 75 -01 -4 <0.001 <0.0003 Xylenes, Total 1330 -20 -7 <0.003 <0.0005 Quality Control Summary for client sample(s) SB -06 -I OFT 44 of 69 M Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Volatile Organic Compounds by Method 8260B L411486 Matrix. - mg /kg Project :Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -01 Sample Date.-71812009 Extraction Date:711512009 Analysis Date:7 11512009 10:54:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431545 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL Benzene 71 -43 -2 <0.001 <0.0003 Methyl tert-butyl ether 1634 -04 -4 <0.001 <0.0003 Toluene 108 -88 -3 <0.005 <0.0012 Laboratory Control Sample (LCS) Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers Benzene 0.050 0.047 94.3 65- 128 Methyl tert-butyl ether 0.050 0.053 106 44-148 Toluene 0.050 0.049 97.7 70- 120 Laboratory Control Sample Duplicate (LCSD) Quality Control Summary for client sample(s) SB- 01 -2FT 45 of 69 True Recovery Control Analyte Value Found % Limits Qualifiers Benzene 0.050 0.047 94.4 65- 128 Methyl tert-butyl ether 0.050 0.051 101 44- 148 Toluene 0.050 0.048 96.6 70- 120 Quality Control Summary for client sample(s) SB- 01 -2FT 45 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -01 Sample Date: 7/8/2009 Extraction Date:7 11712009 Analysis Date:7 11712009 1:53:00 PM Instrument ID: VOCMS 18 Analyst:73 Analytic Batch: WG431941 EPA ID: TN00003 Method Blank Analyte CAS PQL NIDL Ethylbenzene 100 -41 -4 <0.001 <0.0002 Xylenes, Total 1330 -20 -7 <0.003 <0.0005 Laboratory Control Sample (LCS) Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers Ethylbenzene 0.050 0.043 86.4 74-128 Xylenes, Total 0.150 0.131 87.1 74- 127 Laboratory Control Sample Duplicate (LCSD) Quality Control Summary for client sample(s) S13- 0I -2FT 46 of 69 True Recovery Control Analyte Value Found % Limits Qualifiers Ethylbenzene 0.050 0.047 93.8 74-128 Xylenes, Total 0.150 0.140 93.5 74- 127 Quality Control Summary for client sample(s) S13- 0I -2FT 46 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No. Login No. Sample Number: L411486 -04 Sample Date: 7/8/2009 Extraction Date:7 11412009 Analysis Date. 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA ID: TN00003 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers 1, 1, 1,2-Tetrachloroethane 0.050 0.055 H] ] 73 - 134 1, 1, 1 -Trichloroethane 0.050 0.052 104 62- 135 1,1,2,2 - Tetrachloroethane 0.050 0.052 103 74- 129 1,1,2- Trichloroethane 0.050 0.053 106 77- 124 1,1,2 - Trichloro- 1,2,2 - trifluoroethane 0.050 0.049 98.2 49- 155 1, 1 -Dichloroethane 0.050 0.050 100 61- 134 1, 1 -Dichloroethene 0.050 0.050 101 53 - 136 1, 1 -Dichloropropene 0.050 0.053 105 63- 132 1,2,3 - Trichlorobenzene 0.050 0.052 105 62- 146 1,2,3 - Trichloropropane 0.050 0.054 108 70- 133 1,2,3 - Trimethylbenzene 0.050 0.053 107 73- 126 1,2,4 - Trichlorobenzene 0.050 0.052 105 61- 148 1,2,4 - Trimethylbenzene 0.050 0.054 108 68- 135 1,2- Dibromo -3- Chloropropane 0.050 0.045 89.5 61 - 134 1,2- Dibromoethane 0.050 0.054 107 76- 127 1,2- Dichlorobenzene 0.050 0.053 107 77- 123 1,2- Dichloroethane 0.050 0.051 101 58 -141 1,2- Dichloropropane 0.050 0.051 102 71 - 128 1,3,5 - Trimethylbenzene 0.050 0.054 108 71 - 133 1,3- Dichlorobenzene 0.050 0.053 106 71 - 132 1,3- Dichloropropane 0.050 0.051 101 76- 120 1,4- Dichlorobenzene 0.050 0.052 104 72- 123 2,2- Dichloropropane 0.050 0.051 103 50- 147 2- Butanone (MEK) 0.250 0.232 92.7 51 - 131 2- Chloroethyl vinyl ether 0.250 0.274 109 0-188 2- Chlorotoluene 0.050 0.054 108 73 - 128 4- Chlorotoluene 0.050 0.054 107 72- 129 4- Methyl -2- pentanone (MIBK) 0.250 0.267 107 61 - 143 Acetone 0.250 0.231 92.3 44- 140 Acrylonitrile 0.250 0.232 92.6 55- 143 Benzene 0.050 0.047 94.7 65-128 Bromobenzene 0.050 0.051 102 75- 123 Bromodichloromethane 0.050 0.054 109 66- 126 Bromoform 0.050 0.044 88.3 64- 139 Quality Control Summary for client sample(s) SB -04 -1 OFT 47 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Volatile Organic Compounds by Method 8260B L411486 Matrix.-Soil - mg/kg Project: Coppell Auto Center Project No. Login No.-L411486 Sample Number.-L411486-04 Sample Date:71812009 Extraction Date:7114 12009 Analysis Date:711412009 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA ID: TN00003 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Bromomethane 0.050 0.044 88.6 41 - 175 Carbon tetrachloride 0.050 0.051 102 60- 140 Chlorobenzene 0.050 0.052 104 75- 125 Chlorodibromomethane 0.050 0.047 94.3 72- 137 Chloroethane 0.050 0.049 97.2 44- 159 Chloroform 0.050 0.050 100 63- 123 Chloromethane 0.050 0.053 106 42- 149 cis -1,2- Dichloroethene 0.050 0.051 103 71 - 129 cis -1,3- Dichloropropene 0.050 0.057 114 73 - 132 Di- isopropyl ether 0.050 0.050 99.8 59- 143 Dibromomethane 0.050 0.053 106 70- 130 Dichlorodifluoromethane 0.050 0.053 106 26- 186 Ethylbenzene 0.050 0.054 109 74- 128 Hexachloro -1,3- butadiene 0.050 0.051 103 65- 137 Isopropylbenzene 0.050 0.057 114 73- 130 Methyl tert-butyl ether 0.050 0.047 94.4 44- 148 Methylene Chloride 0.050 0.048 96.3 57- 129 n- Butylbenzene 0.050 0.055 109 60 -145 n- Propylbenzene 0.050 0.055 110 71 - 132 Naphthalene 0.050 0.054 109 61 - 142 p-Isopropyltoluene 0.050 0.055 110 67- 138 sec - Butylbenzene 0.050 0.054 109 71 - 134 Styrene 0.050 0.054 109 76- 133 tert- Butylbenzene 0.050 0.054 108 72- 132 Tetrachloroethene 0.050 0.054 108 65- 135 Toluene 0.050 0.052 103 70- 120 trans -1,2- Dichloroethene 0.050 0.050 101 61 - 133 trans -1,3- Dichloropropene 0.050 0.049 97.8 70- 135 Trichloroethene 0.050 0.053 105 71 - 126 Trichlorofluoromethane 0.050 0.054 109 52- 147 Vinyl chloride 0.050 0.052 103 50- 151 Xylenes, Total 0.150 0.167 111 74- 127 Quality Control Summary for client sample(s) SB -04 -1 OFT 48 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -04 Sample Date.-71812009 Extraction Date:7114 12009 Analysis Date:711412009 10:06:00 PM Instrument ID: VOCMS6 Analyst:167 Analytic Batch: WG431385 EPA ID: TN00003 Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers 1, 1, 1,2-Tetrachloroethane 0.050 0.052 104 73- 134 1, 1, 1 -Trichloroethane 0.050 0.050 99.5 62- 135 1,1,2,2 - Tetrachloroethane 0.050 0.050 100 74- 129 1,1,2 - Trichloroethane 0.050 0.051 101 77- 124 1, 1,2-Trichloro- 1,2,2-trifluoroethane 0.050 0.047 93.6 49- 155 1, 1 -Dichloroethane 0.050 0.049 97.0 61 - 134 I,1- Dichloroethene 0.050 0.049 97.0 53- 136 1,1- Dichloropropene 0.050 0.050 101 63- 132 1,2,3 - Trichlorobenzene 0.050 0.049 98.7 62- 146 1,2,3 - Trichloropropane 0.050 0.051 103 70- 133 1,2,3 - Trimethylbenzene 0.050 0.051 103 73- 126 1,2,4 - Trichlorobenzene 0.050 0.050 99.5 61 -148 1,2,4 - Trimethylbenzene 0.050 0.051 102 68- 135 1,2- Dibromo -3- Chloropropane 0.050 0.045 90.5 61 - 134 1,2- Dibromoethane 0.050 0.050 101 76- 127 1,2- Dichlorobenzene 0.050 0.051 102 77- 123 1,2- Dichloroethane 0.050 0.049 98.0 58- 141 1,2- Dichloropropane 0.050 0.049 97.2 71 - 128 1,3,5 - Trimethylbenzene 0.050 0.052 103 71 - 133 1,3- Dichlorobenzene 0.050 0.051 102 71 - 132 1,3- Dichloropropane 0.050 0.047 94.4 76- 120 1,4- Dichlorobenzene 0.050 0.050 99.5 72- 123 2,2- Dichloropropane 0.050 0.048 96.8 50- 147 2- Butanone (MEK) 0.250 0.224 89.7 51 - 131 2- Chloroethyl vinyl ether 0.250 0.265 106 0- 188 2- Chlorotoluene 0.050 0.051 103 73 - 128 4- Chlorotoluene 0.050 0.051 102 72- 129 4- Methyl -2- pentanone (MIBK) 0.250 0.260 104 61 - 143 Acetone 0.250 0.220 87.8 44- 140 Acrylonitrile 0.250 0.261 104 55 - 143 Benzene 0.050 0.046 91.6 65- 128 Bromobenzene 0.050 0.048 96.9 75- 123 Bromodichloromethane 0.050 0.053 107 66- 126 Bromoform 0.050 0.043 86.7 64- 139 Quality Control Summary for client sample(s) SB -04 -1 OFT 49 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test.-Volatile Organic Compounds by Method 8260B L411486 Matrix. - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No: L411486 Sample Number: L411486 -04 Sample Date: 7/8/2009 Extraction Date:7 11412009 Analysis Date:7 11412009 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA ID: TN00003 Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers Bromomethane 0.050 0.038 76.3 41 - 175 Carbon tetrachloride 0.050 0.049 97.0 60- 140 Chlorobenzene 0.050 0.049 98.3 75- 125 Chlorodibromomethane 0.050 0.045 90.5 72- 137 Chloroethane 0.050 0.040 80.1 44- 159 Chloroform 0.050 0.047 94.7 63- 123 Chloromethane 0.050 0.048 95.2 42- 149 cis -1,2- Dichloroethene 0.050 0.049 97.4 71 - 129 cis -1,3- Dichloropropene 0.050 0.054 109 73- 132 Di- isopropyl ether 0.050 0.048 96.0 59- 143 Dibromomethane 0.050 0.052 104 70- 130 Dichlorodifluoromethane 0.050 0.047 95.0 26- 186 Ethylbenzene 0.050 0.051 103 74- 128 Hexachloro -1,3- butadiene 0.050 0.048 97.0 65- 137 Isopropylbenzene 0.050 0.054 108 73 -130 Methyl tert-butyl ether 0.050 0.046 91.2 44- 148 Methylene Chloride 0.050 0.046 91.7 57- 129 n- Butylbenzene 0.050 0.052 104 60- 145 n- Propylbenzene 0.050 0.053 105 71 -132 Naphthalene 0.050 0.052 103 61 - 142 p- Isopropyltoluene 0.050 0.052 105 67- 138 sec - Butylbenzene 0.050 0.051 103 71 - 134 Styrene 0.050 0.052 105 76- 133 tert- Butylbenzene 0.050 0.051 102 72- 132 Tetrachloroethene 0.050 0.051 101 65- 135 Toluene 0.050 0.048 96.6 70- 120 trans -1,2- Dichloroethene 0.050 0.048 95.0 61- 133 trans -1,3- Dichloropropene 0.050 0.046 92.2 70- 135 Trichloroethene 0.050 0.051 103 71- 126 Trichlorofluoromethane 0.050 0.051 101 52- 147 Vinyl chloride 0.050 0.048 95.9 50- 151 Xylenes, Total 0.150 0.158 105 74- 127 Quality Control Summary for client sample(s) SB -04 -1 OFT 50 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No.-L411486 Sample Number. Sample Date. Extraction Date: 7 /15/2009 Analysis Date:7 11512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers 1, 1, 1,2-Tetrachloroethane 0.050 0.050 101 73 - 134 1, 1, 1 -Trichloroethane 0.050 0.047 94.0 62- 135 1,1,2,2 - Tetrachloroethane 0.050 0.055 111 74- 129 1,1,2 - Trichloroethane 0.050 0.052 105 77- 124 1, 1,2-Trichloro- 1,2,2-trifluoroethane 0.050 0.045 90.2 49- 155 1, 1 -Dichloroethane 0.050 0.046 91.5 61 - 134 1, 1 -Dichloroethene 0.050 0.049 97.7 53- 136 1, 1 -Dichloropropene 0.050 0.047 94.1 63- 132 1,2,3 - Trichlorobenzene 0.050 0.053 106 62- 146 1,2,3 - Trichloropropane 0.050 0.059 117 70- 133 1,2,3 - Trimethylbenzene 0.050 0.046 91.3 73 - 126 1,2,4- Trichlorobenzene 0.050 0.055 110 61 - 148 1,2,4 - Trimethylbenzene 0.050 0.051 102 68- 135 1,2- Dibromo -3- Chloropropane 0.050 0.050 99.7 61 - 134 1,2- Dibromoethane 0.050 0.052 105 76- 127 1,2- Dichlorobenzene 0.050 0.048 95.2 77- 123 1,2- Dichloroethane 0.050 0.044 87.2 58- 141 1,2- Dichloropropane 0.050 0.045 89.7 71 - 128 1,3,5- Trimethylbenzene 0.050 0.051 102 71 - 133 1,3- Dichlorobenzene 0.050 0.052 105 71 - 132 1,3- Dichloropropane 0.050 0.050 99.8 76- 120 1,4- Dichlorobenzene 0.050 0.048 95.6 72- 123 2,2- Dichloropropane 0.050 0.046 92.8 50- 147 2- Butanone (MEK) 0.250 0.253 101 51 - 131 2- Chloroethyl vinyl ether 0.250 0.268 107 0- 188 2- Chlorotoluene 0.050 0.050 100 73 - 128 4- Chlorotoluene 0.050 0.052 103 72- 129 4- Methyl -2- pentanone (MIBK) 0.250 0.275 110 61 - 143 Acetone 0.250 0.253 101 44- 140 Acrylonitrile 0.250 0.261 104 55- 143 Benzene 0.050 0.046 92.3 65- 128 Bromobenzene 0.050 0.049 97.7 75- 123 Bromodichloromethane 0.050 0.046 91.4 66- 126 Bromoform 0.050 0.057 115 64- 139 Quality Control Summary for client sample(s) SB -06 -1 OFT 51 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Volatile Organic Compounds by Method 8260B L411486 Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -06 Sample Date: 71812009 Extraction Date:7 11512009 Analysis Date:7 11512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Bromomethane 0.050 0.048 96.1 41- 175 Carbon tetrachloride 0.050 0.046 92.3 60- 140 Chlorobenzene 0.050 0.052 103 75- 125 Chlorodibromomethane 0.050 0.054 109 72- 137 Chloroethane 0.050 0.050 99.2 44- 159 Chloroform 0.050 0.045 89.5 63- 123 Chloromethane 0.050 0.050 100 42- 149 cis -1,2- Dichloroethene 0.050 0.047 94.8 71 - 129 cis -1,3- Dichloropropene 0.050 0.047 93.7 73 - 132 Di- isopropyl ether 0.050 0.048 95.9 59- 143 Dibromomethane 0.050 0.047 94.1 70- 130 Dichlorodifluoromethane 0.050 0.056 111 26- 186 Ethylbenzene 0.050 0.051 103 74 -128 Hexachloro -1,3- butadiene 0.050 0.048 95.6 65- 137 Isopropylbenzene 0.050 0.052 104 73 -130 Methyl tert-butyl ether 0.050 0.047 94.6 44- 148 Methylene Chloride 0.050 0.044 88.3 57- 129 n- Butylbenzene 0.050 0.049 97.6 60 -145 n- Propylbenzene 0.050 0.051 102 71 -132 Naphthalene 0.050 0.055 109 61- 142 p- Isopropyltoluene 0.050 0.052 104 67- 138 sec- Butylbenzene 0.050 0.051 103 71- 134 Styrene 0.050 0.056 112 76- 133 tert- Butylbenzene 0.050 0.052 104 72 -132 Tetrachloroethene 0.050 0.051 102 65 -135 Toluene 0.050 0.046 92.0 70-120 trans- l,2- Dichloroethene 0.050 0.047 94.7 61 - 133 trans -1,3- Dichloropropene 0.050 0.043 85.3 70- 135 Trichloroethene 0.050 0.049 97.5 71- 126 Trichlorofluoromethane 0.050 0.048 95.3 52- 147 Vinyl chloride 0.050 0.054 107 50-151 Xylenes, Total 0.150 0.156 104 74- 127 Quality Control Summary for client sample(s) SB -06 -1 OFT 52 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No: L411486 Sample Number: L411486 -06 Sample Date.-71812009 Extraction Date:711512009 Analysis Date:7 11512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers 1, 1, 1,2-Tetrachloroethane 0.050 0.058 115 73 - 134 1, 1, 1 -Trichloroethane 0.050 0.051 101 62- 135 1,1,2,2 - Tetrachloroethane 0.050 0.061 121 74- 129 1,1,2 - Trichloroethane 0.050 0.058 115 77- 124 1, 1,2-Trichloro- 1,2,2-trifluoroethane 0.050 0.051 102 49- 155 1,1- Dichloroethane 0.050 0.048 96.0 61- 134 1,1- Dichloroethene 0.050 0.054 109 53- 136 1,1- Dichloropropene 0.050 0.050 101 63- 132 1,2,3 - Trichlorobenzene 0.050 0.061 121 62- 146 1,2,3 - Trichloropropane 0.050 0.061 122 70- 133 1,2,3 - Trimethylbenzene 0.050 0.050 99.1 73- 126 1,2,4- Trichlorobenzene 0.050 0.061 123 61 - 148 1,2,4 - Trimethylbenzene 0.050 0.057 113 68- 135 1,2- Dibromo -3- Chloropropane 0.050 0.055 110 61 - 134 1,2- Dibromoethane 0.050 0.057 114 76- 127 1,2- Dichlorobenzene 0.050 0.053 106 77- 123 1,2- Dichloroethane 0.050 0.046 92.1 58- 141 1,2- Dichloropropane 0.050 0.049 98.7 71 - 128 1,3,5 - Trimethylbenzene 0.050 0.058 115 71 - 133 1,3- Dichlorobenzene 0.050 0.060 121 71 - 132 1,3- Dichloropropane 0.050 0.055 109 76- 120 1,4- Dichlorobenzene 0.050 0.052 104 72- 123 2,2- Dichloropropane 0.050 0.050 99.1 50- 147 2- Butanone (MEK) 0.250 0.252 101 51 - 131 2- Chloroethyl vinyl ether 0.250 0.201 80.4 0- 188 2- Chlorotoluene 0.050 0.057 114 73 -128 4- Chlorotoluene 0.050 0.059 118 72- 129 4- Methyl -2- pentanone (MIBK) 0.250 0.284 113 61 - 143 Acetone 0.250 0.247 98.8 44- 140 Acrylonitrile 0.250 0.261 104 55- 143 Benzene 0.050 0.050 99.8 65- 128 Bromobenzene 0.050 0.056 112 75- 123 Bromodichloromethane 0.050 0.050 101 66- 126 Bromoform 0.050 0.064 127 64- 139 Quality Control Summary for client sample(s) SB -06 -1 OFT 53 of 69 hkA Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No.-L411486 Sample Number: L411486 -06 Sample Date. Extraction Date:7 11512009 Analysis Date:7 11512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers Bromomethane 0.050 0.050 99.8 41- 175 Carbon tetrachloride 0.050 0.050 99.0 60- 140 Chlorobenzene 0.050 0.056 112 75- 125 Chlorodibromomethane 0.050 0.059 119 72- 137 Chloroethane 0.050 0.051 103 44- 159 Chloroform 0.050 0.048 96.7 63- 123 Chloromethane 0.050 0.052 104 42- 149 cis -1,2- Dichloroethene 0.050 0.051 103 71 - 129 cis -1,3- Dichloropropene 0.050 0.052 104 73- 132 Di- isopropyl ether 0.050 0.050 99.1 59- 143 Dibromomethane 0.050 0.050 101 70- 130 Dichlorodifluoromethane 0.050 0.059 118 26- 186 Ethylbenzene 0.050 0.057 114 74- 128 Hexachloro -1,3- butadiene 0.050 0.054 108 65 -137 Isopropylbenzene 0.050 0.058 116 73 -130 Methyl tert-butyl ether 0.050 0.048 95.1 44- 148 Methylene Chloride 0.050 0.047 93.5 57- 129 n- Butylbenzene 0.050 0.053 106 60- 145 n- Propylbenzene 0.050 0.059 117 71 -132 Naphthalene 0.050 0.060 119 61- 142 p- Isopropyltoluene 0.050 0.060 120 67- 138 sec - Butylbenzene 0.050 0.059 117 71 - 134 Styrene 0.050 0.062 125 76- 133 tert- Butylbenzene 0.050 0.059 118 72- 132 Tetrachloroethene 0.050 0.057 114 65- 135 Toluene 0.050 0.051 103 70- 120 trans -1,2- Dichloroethene 0.050 0.051 102 61 -133 trans -1,3- Dichloropropene 0.050 0.046 91.9 70- 135 Trichloroethene 0.050 0.054 108 71- 126 Trichlorofluoromethane 0.050 0.049 98.0 52- 147 Vinyl chloride 0.050 0.055 110 50- 151 Xylenes, Total 0.150 0.176 117 74- 127 Quality Control Summary for client sample(s) SB -06 -1 OFT 54 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No. Login No: L411486 Sample Number: L411486 -02 Sample Date. Extraction Date. Analysis Date:7 11512009 5:42:00 AM Instrument ID: VOCMS 1 Analyst: 140 Analytic Batch: WG431272 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Matrix Spike /Matrix Spike Duplicate L411290 -12 Spike % % % Control % Control Analyte Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali Benzene 0.050 0.047 94.2 0.044 87.6 65 -128 7.2 20 Ethylbenzene 0.050 0.046 91.7 0.044 87.3 74 -128 4.9 20 Methyl tert-butyl ether 0.050 0.047 93.0 0.044 87.8 44 -148 5.7 20 Toluene 0.050 0.047 93.1 0.045 89.1 70 -120 4.4 20 Xylenes, Total 0.150 0.141 94.2 0.136 90.5 74 -127 4.0 20 Matrix Spike /Matrix Spike Duplicate L411290 -12 Quality Control Summary for client sample(s) S13- 02 -2FT 55 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Benzene 0.250 0.000 0.307 123 0.250 100 16 -143 20 31 Ethylbenzene 0.250 0.000 0.302 121 0.246 98.6 12 -137 20 36 Methyl tert -butyl ether 0.250 0.000 0.303 121 0.247 98.7 21 -157 21 31 Toluene 0.250 0.000 0.302 121 0.243 97.1 12 -136 22 32 Xylenes, Total 0.750 0.000 0.945 126 0.758 101 10 -138 22 36 Quality Control Summary for client sample(s) S13- 02 -2FT 55 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test.-Volatile Organic Compounds by Method 8260B L411486 Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No.-L411486 Sample Number: L411486 -04 Sample Date:71812009 Extraction Date:7 /14/2009 Analysis Date:711412009 10:06:00 PM Instrument ID: VOCMS6 Analyst:167 Analytic Batch: WG431385 EPA ID: TN00003 Matrix Spike /Matrix Spike Duplicate L411492 -01 Quality Control Summary for client sample(s) SB -04 -1 OFT 56 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali 1, 1, 1,2-Tetrachloroethane 0.250 0.000 0.270 108 0.268 107 29 -145 0.6 31 1, 1, 1 -Trichloroethane 0.250 0.000 0.279 112 0.258 103 23 -147 7.8 32 1,1,2,2 - Tetrachloroethane 0.250 0.000 0.257 103 0.270 108 18 -150 4.8 33 1,1,2 - Trichloroethane 0.250 0.000 0.254 101 0.260 104 35 -140 2.5 29 1, 1,2-Trichloro- 1,2,2- 0.250 0.000 0.263 105 0.239 95.4 10 -145 9.6 35 1, 1 -Dichloroethane 0.250 0.000 0.271 108 0.252 101 24 -148 7.2 31 1,1- Dichloroethene 0.250 0.000 0.271 108 0.249 99.7 10 -149 8.3 34 1,1- Dichloropropene 0.250 0.000 0.268 107 0.258 103 10 -141 3.9 34 1,2,3 - Trichlorobenzene 0.250 0.000 0.216 86.5 0.211 84.6 10 -129 2.3 43 1,2,3 - Trichloropropane 0.250 0.000 0.263 105 0.275 110 30 -148 4.4 32 1,2,3 - Trimethylbenzene 0.250 0.000 0.259 104 0.252 101 10 -137 2.6 36 1,2,4 - Trichlorobenzene 0.250 0.000 0.226 90.3 0.210 83.9 10 -119 7.3 44 1,2,4 - Trimethylbenzene 0.250 0.000 0.258 103 0.253 101 10 -145 2.0 41 1,2- Dibromo -3- Chloropropane 0.250 0.000 0.226 90.4 0.244 97.7 19 -145 7.8 35 1,2- Dibromoethane 0.250 0.000 0.261 104 0.269 108 24 -145 3.2 31 1,2- Dichlorobenzene 0.250 0.000 0.252 101 0.249 99.5 12 -130 1.3 35 1,2- Dichloroethane 0.250 0.000 0.260 104 0.259 104 21 -155 0.5 29 1,2- Dichloropropane 0.250 0.000 0.248 99.3 0.247 98.9 28 -144 0.3 30 1,3,5 - Trimethylbenzene 0.250 0.000 0.263 105 0.254 101 10 -135 3.5 39 1,3- Dichlorobenzene 0.250 0.000 0.258 103 0.246 98.6 10 -129 4.5 38 1,3- Dichloropropane 0.250 0.000 0.239 95.5 0.248 99.0 31 -137 3.6 29 1,4- Dichlorobenzene 0.250 0.000 0.246 98.5 0.238 95.2 10 -121 3.4 36 2,2- Dichloropropane 0.250 0.000 0.278 111 0.252 101 18 -144 10.0 32 2- Butanone (MEK) 1.25 0.000 1.15 92.0 1.20 96.4 21 -143 4.6 37 2- Chloroethyl vinyl ether 1.25 0.000 1.37 110 1.35 108 0 -176 2.0 50 2- Chlorotoluene 0.250 0.000 0.259 103 0.254 102 10 -132 1.8 37 4- Chlorotoluene 0.250 0.000 0.255 102 0.247 98.9 10 -129 2.9 38 4- Methyl -2- pentanone 1.25 0.000 1.32 106 1.40 112 31 -151 5.6 36 Acetone 1.25 0.000 1.26 101 1.30 104 13 -158 2.7 34 Acrylonitrile 1.25 0.000 1.23 98.6 1.24 98.9 20 -154 0.3 35 Benzene 0.250 0.000 0.244 97.4 0.236 94.5 16 -143 3.0 31 Bromobenzene 0.250 0.000 0.240 95.8 0.240 96.2 14 -135 0.4 39 Bromodichloromethane 0.250 0.000 0.274 110 0.270 108 27 -139 1.4 30 Bromoform 0.250 0.000 0.213 85.1 0.225 90.0 21 -144 5.6 34 Quality Control Summary for client sample(s) SB -04 -1 OFT 56 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test. - Volatile Organic Compounds by Method 8260B L411486 Matrix.-Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No.-L411486 Sample Number. Sample Date: 7/8/2009 Extraction Date:711412009 Analysis Date:711412009 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA 1D: TN00003 Matrix Spike /Matrix Spike Duplicate L411492 -01 Quality Control Summary for client sample(s) SB -04 -1 OFT 57 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Bromomethane 0.250 0.000 0.273 109 0.209 83.5 0 -180 27 41 Carbon tetrachloride 0.250 0.000 0.273 109 0.254 101 12 -149 7.2 34 Chlorobenzene 0.250 0.000 0.249 99.6 0.247 98.9 17 -134 0.7 34 Chlorodibromomethane 0.250 0.000 0.227 90.9 0.235 93.9 28 -147 3.3 32 Chloroethane 0.250 0.000 0.309 124 0.233 93.4 0 -172 28 38 Chloroform 0.250 0.000 0.261 104 0.251 100 28 -138 4.0 30 Chloromethane 0.250 0.000 0.277 111 0.239 95.8 10 -158 15 35 cis -1,2- Dichloroethene 0.250 0.000 0.274 109 0.256 103 21 -147 6.4 31 cis -1,3- Dichloropropene 0.250 0.000 0.285 114 0.282 113 17 -145 1.4 32 Di- isopropyl ether 0.250 0.000 0.267 107 0.255 102 31 -153 4.7 29 Dibromomethane 0.250 0.000 0.267 107 0.272 109 24 -147 1.9 30 Dichlorodifluoromethane 0.250 0.000 0.288 115 0.256 102 0 -192 12 38 Ethylbenzene 0.250 0.000 0.264 105 0.257 103 12 -137 2.7 36 Hexachloro -1,3- butadiene 0.250 0.000 0.192 76.8 0.181 72.4 10 -123 5.8 50 Isopropylbenzene 0.250 0.000 0.274 110 0.268 107 14 -134 2.2 37 Methyl tert-butyl ether 0.250 0.000 0.259 104 0.248 99.3 21 -157 4.3 31 Methylene Chloride 0.250 0.000 0.262 105 0.241 96.5 12 -149 8.4 31 n- Butylbenzene 0.250 0.000 0.247 98.7 0.237 94.7 10 -130 4.1 48 n- Propylbenzene 0.250 0.000 0.264 106 0.257 103 10 -130 2.8 40 Naphthalene 0.250 0.000 0.240 95.9 0.243 97.3 0 -146 1.4 43 p- Isopropyltoluene 0.250 0.000 0.262 105 0.250 100.0 10 -131 4.7 43 sec - Butylbenzene 0.250 0.000 0.258 103 0.246 98.5 10 -134 4.9 43 Styrene 0.250 0.000 0.261 104 0.260 104 10 -140 0.0 35 tert- Butylbenzene 0.250 0.000 0.257 103 0.248 99.4 11 -137 3.2 39 Tetrachloroethene 0.250 0.000 0.250 100 0.248 99.0 10 -131 1.1 35 Toluene 0.250 0.000 0.253 101 0.244 97.6 12 -136 3.8 32 trans -1,2- Dichloroethene 0.250 0.000 0.272 109 0.253 101 10 -143 7.3 33 trans -1,3- Dichloropropene 0.250 0.000 0.247 98.9 0.237 94.6 16 -147 4.4 32 Trichloroethene 0.250 0.000 0.259 104 0.255 102 10 -155 1.7 33 Trichlorofluoromethane 0.250 0.000 0.303 121 0.264 105 10 -154 14 32 Vinyl chloride 0.250 0.000 0.282 113 0.247 98.9 10 -159 13 36 Xylenes, Total 0.750 0.000 0.804 107 0.790 105 10 -138 1.7 36 Quality Control Summary for client sample(s) SB -04 -1 OFT 57 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -04 Sample Date. Extraction Date:711412009 Analysis Date:711412009 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Spike % % Control % Control Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali 1, 1, 1,2-Tetrachloroethane 0.050 0.055 111 0.052 104 73 -134 5.7 20 1, 1, 1 -Trichloroethane 0.050 0.052 104 0.050 99.5 62 -135 4.2 20 1,1,2,2 - Tetrachloroethane 0.050 0.052 103 0.050 100 74 -129 3.0 20 1,1,2 - Trichloroethane 0.050 0.053 106 0.051 101 77 -124 4.9 20 1,1,2 - Trichloro- 1,2,2- 0.050 0.049 98.2 0.047 93.6 49 -155 4.8 20 1, 1 -Dichloroethane 0.050 0.050 100 0.049 97.0 61 -134 3.3 20 1,1- Dichloroethene 0.050 0.050 101 0.049 97.0 53 -136 3.9 20 1, 1 -Dichloropropene 0.050 0.053 105 0.050 101 63 -132 4.2 20 1,2,3 - Trichlorobenzene 0.050 0.052 105 0.049 98.7 62 -146 6.0 20 1,2,3 - Trichloropropane 0.050 0.054 108 0.051 103 70 -133 5.2 20 1,2,3 - Trimethylbenzene 0.050 0.053 107 0.051 103 73 -126 4.0 20 1,2,4 - Trichlorobenzene 0.050 0.052 105 0.050 99.5 61 -148 4.9 20 1,2,4 - Trimethylbenzene 0.050 0.054 108 0.051 102 68 -135 5.2 20 1,2- Dibromo -3- Chloropropane 0.050 0.045 89.5 0.045 90.5 61 -134 1.1 21 1,2- Dibromoethane 0.050 0.054 107 0.050 101 76 -127 5.9 20 1,2- Dichlorobenzene 0.050 0.053 107 0.051 102 77 -123 3.9 20 1,2- Dichloroethane 0.050 0.051 101 0.049 98.0 58 -141 3.2 20 1,2- Dichloropropane 0.050 0.051 102 0.049 97.2 71 -128 4.3 20 1,3,5 - Trimethylbenzene 0.050 0.054 108 0.052 103 71 -133 4.9 20 1,3- Dichlorobenzene 0.050 0.053 106 0.051 102 71 -132 4.3 20 1,3- Dichloropropane 0.050 0.051 101 0.047 94.4 76 -120 6.8 20 1,4- Dichlorobenzene 0.050 0.052 104 0.050 99.5 72 -123 4.2 20 2,2- Dichloropropane 0.050 0.051 103 0.048 96.8 50 -147 5.7 20 2- Butanone (MEK) 0.250 0.232 92.7 0.224 89.7 51 -131 3.2 25 2- Chloroethyl vinyl ether 0.250 0.274 109 0.265 106 0 -188 3.4 39 2- Chlorotoluene 0.050 0.054 108 0.051 103 73 -128 5.4 20 4- Chlorotoluene 0.050 0.054 107 0.051 102 72 -129 4.9 20 4- Methyl -2- pentanone 0.250 0.267 107 0.260 104 61 -143 2.9 23 Acetone 0.250 0.231 92.3 0.220 87.8 44 -140 5.0 25 Acrylonitrile 0.250 0.232 92.6 0.261 104 55 -143 12 20 Benzene 0.050 0.047 94.7 0.046 91.6 65 -128 3.3 20 Bromobenzene 0.050 0.051 102 0.048 96.9 75 -123 4.7 20 Bromodichloromethane 0.050 0.054 109 0.053 107 66 -126 2.1 20 Bromoform 0.050 0.044 88.3 0.043 86.7 64 -139 1.9 20 Control Summary for client sample(s) SB -04 -1 OFT 58 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No.-L411486 Sample Number: L411486 -04 Sample Date: 7/8/2009 Extraction Date: 7/ 14/2009 Analysis Date:7 11412009 10:06:00 PM Instrument ID: VOCMS6 Analyst: 167 Analytic Batch: WG431385 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Spike % % Control % Control Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali Bromomethane 0.050 0.044 88.6 0.038 76.3 41 -175 15 20 Carbon tetrachloride 0.050 0.051 102 0.049 97.0 60 -140 5.2 20 Chlorobenzene 0.050 0.052 104 0.049 98.3 75 -125 6.1 20 Chlorodibromomethane 0.050 0.047 94.3 0.045 90.5 72 -137 4.1 20 Chloroethane 0.050 0.049 97.2 0.040 80.1 44 -159 19 20 Chloroform 0.050 0.050 100 0.047 94.7 63 -123 5.5 20 Chloromethane 0.050 0.053 106 0.048 95.2 42 -149 10 20 cis -1,2- Dichloroethene 0.050 0.051 103 0.049 97.4 71 -129 5.2 20 cis -1,3- Dichloropropene 0.050 0.057 114 0.054 109 73 -132 4.8 20 Di- isopropyl ether 0.050 0.050 99.8 0.048 96.0 59 -143 3.9 20 Dibromomethane 0.050 0.053 106 0.052 104 70 -130 2.3 20 Dichlorodifluoromethane 0.050 0.053 106 0.047 95.0 26 -186 11 22 Ethylbenzene 0.050 0.054 109 0.051 103 74 -128 5.5 20 Hexachloro -1,3- butadiene 0.050 0.051 103 0.048 97.0 65 -137 5.6 20 Isopropylbenzene 0.050 0.057 114 0.054 108 73 -130 5.6 20 Methyl tert-butyl ether 0.050 0.047 94.4 0.046 91.2 44 -148 3.5 20 Methylene Chloride 0.050 0.048 96.3 0.046 91.7 57 -129 5.0 20 n- Butylbenzene 0.050 0.055 109 0.052 104 60 -145 4.8 20 n- Propylbenzene 0.050 0.055 110 0.053 105 71 -132 4.3 20 Naphthalene 0.050 0.054 109 0.052 103 61 -142 4.8 20 p- Isopropyltoluene 0.050 0.055 110 0.052 105 67 -138 5.3 20 sec - Butylbenzene 0.050 0.054 109 0.051 103 71 -134 5.5 20 Styrene 0.050 0.054 109 0.052 105 76 -133 3.8 20 tert- Butylbenzene 0.050 0.054 108 0.051 102 72 -132 6.1 20 Tetrachloroethene 0.050 0.054 108 0.051 101 65 -135 6.1 20 Toluene 0.050 0.052 103 0.048 96.6 70 -120 6.5 20 trans- l,2- Dichloroethene 0.050 0.050 101 0.048 95.0 61 -133 5.9 20 trans -1,3- Dichloropropene 0.050 0.049 97.8 0.046 92.2 70 -135 5.9 20 Trichloroethene 0.050 0.053 105 0.051 103 71 -126 2.4 20 Trichlorofluoromethane 0.050 0.054 109 0.051 101 52 -147 7.3 20 Vinyl chloride 0.050 0.052 103 0.048 95.9 50 -151 7.2 20 Xylenes, Total 0.150 0.167 111 0.158 105 74 -127 5.5 20 Quality Control Summary for client sample(s) SB -04 -1 OFT 59 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No.-940.002 Login No. Sample Number: L411486 -06 Sample Date:71812009 Extraction Date:711512009 Analysis Date.-711512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analvtic Batch: WG431498 Matrix Spike /Matrix Spike Duplicate L411666 -08 EPA ID: TN00003 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali 1, 1, 1,2-Tetrachloroethane 2.43 0.000 3.43 141 2.97 123 29 -145 1, 1, 1 -Trichloroethane 2.43 0.000 3.44 142 3.05 126 23 -147 1,1,2,2 - Tetrachloroethane 2.43 0.000 3.04 125 2.65 109 18 -150 1,1,2 - Trichloroethane 2.43 0.000 3.67 151 3.18 131 35 -140 1, 1,2-Trichloro- 1,2,2- 2.43 0.000 3.89 160 3.59 148 10 -145 I,1- Dichloroethane 2.43 0.000 3.18 131 2.78 115 24 -148 1,1- Dichloroethene 2.43 0.000 3.88 160 3.44 142 10 -149 1, 1 -Dichloropropene 2.43 0.000 3.34 138 2.94 121 10 -141 1,2,3 - Trichlorobenzene 2.43 0.016 3.76 154 3.59 147 10 -129 1,2,3 - Trichloropropane 2.43 0.000 3.22 133 2.94 121 30 -148 1,2,3 - Trimethylbenzene 2.43 0.000 3.16 130 2.82 116 10 -137 1,2,4- Trichlorobenzene 2.43 0.012 3.74 154 3.52 145 10 -119 1,2,4 - Trimethylbenzene 2.43 0.000 3.30 136 2.85 117 10 -145 1,2- Dibromo -3- Chloropropane 2.43 0.000 3.20 132 2.83 117 19 -145 1,2- Dibromoethane 2.43 0.000 3.48 143 3.01 124 24 -145 1,2- Dichlorobenzene 2.43 0.000 3.16 130 2.84 117 12 -130 1,2- Dichloroethane 2.43 0.000 2.76 114 2.43 100 21 -155 1,2- Dichloropropane 2.43 0.000 3.03 125 2.74 113 28 -144 1,3,5 - Trimethylbenzene 2.43 0.000 3.24 134 2.87 118 10 -135 1,3- Dichlorobenzene 2.43 0.000 3.36 138 2.97 122 10 -129 1,3- Dichloropropane 2.43 0.000 3.22 133 2.85 118 31 -137 1,4- Dichlorobenzene 2.43 0.000 3.11 128 2.78 115 10 -121 2,2- Dichloropropane 2.43 0.000 3.49 144 3.09 127 18 -144 2- Butanone (MEK) 12.1 0.000 11.7 96.7 10.5 86.8 21 -143 2- Chloroethyl vinyl ether 12.1 0.000 13.6 112 10.4 86.1 0 -176 2- Chlorotoluene 2.43 0.000 3.11 128 2.74 113 10 -132 4- Chlorotoluene 2.43 0.000 3.23 133 2.81 116 10 -129 4- Methyl -2- pentanone 12.1 0.000 12.7 105 11.4 94.2 31 -151 Acetone 12.1 0.000 11.8 97.3 10.8 89.5 13 -158 Acrylonitrile 12.1 0.000 14.6 120 13.1 108 20 -154 Benzene 2.43 0.000 3.19 131 2.82 116 16 -143 Bromobenzene 2.43 0.000 3.10 128 2.74 113 14 -135 Bromodichloromethane 2.43 0.000 2.98 123 2.68 111 27 -139 Bromoform 2.43 0.000 3.25 134 2.84 117 21 -144 J5 J5 J5 J5 J5 J5 J5 J5 J5 14 31 12 32 14 33 14 29 8.1 35 14 31 12 34 13 34 4.7 43 9.2 32 11 36 6.1 44 15 41 12 35 14 31 11 35 12 29 10 30 12 39 12 38 12 29 11 36 12 32 11 37 26 50 12 37 14 38 11 36 8.4 34 11 35 12 31 12 39 11 30 13 34 Quality Control Summary for client sample(s) S13-06 -1 OFT 60 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No. Login No: L411486 Sample Number: L411486 -06 Sample Date. Extraction Date:711512009 Analysis Date:7 11512009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst:140 Analytic Batch: WG431498 EPA ID: TN00003 Matrix Spike /Matrix Spike Duplicate L411666 -08 Quality Control Summary for client sample(s) SB -06 -1 OFT 61 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Bromomethane 2.43 0.000 2.32 95.6 2.02 83.5 0 -180 14 41 Carbon tetrachloride 2.43 0.000 3.17 131 2.86 118 12 -149 10 34 Chlorobenzene 2.43 0.000 3.37 139 2.96 122 17 -134 J5 13 34 Chlorodibromomethane 2.43 0.000 3.70 152 3.15 130 28 -147 J5 16 32 Chloroethane 2.43 0.000 1.79 73.9 1.52 62.8 0 -172 16 38 Chloroform 2.43 0.000 3.16 130 2.88 119 28 -138 9.4 30 Chloromethane 2.43 0.000 2.84 117 2.48 102 10 -158 13 35 cis -1,2- Dichloroethene 2.43 0.000 3.33 137 2.96 122 21 -147 12 31 cis -1,3- Dichloropropene 2.43 0.000 3.08 127 2.76 114 17 -145 11 32 Di- isopropyl ether 2.43 0.000 3.30 136 2.92 120 31 -153 12 29 Dibromomethane 2.43 0.000 3.06 126 2.78 115 24 -147 9.8 30 Dichlorodifluoromethane 2.43 0.000 3.01 124 2.66 110 0 -192 12 38 Ethylbenzene 2.43 0.000 3.43 141 2.93 121 12 -137 J5 16 36 Hexachloro -1,3- butadiene 2.43 0.000 3.36 139 3.10 128 10 -123 J5 8.1 50 Isopropylbenzene 2.43 0.000 3.25 134 2.85 117 14 -134 J5 13 37 Methyl tert-butyl ether 2.43 0.000 3.05 126 2.75 113 21 -157 10 31 Methylene Chloride 2.43 0.000 3.05 126 2.72 112 12 -149 12 31 n- Butylbenzene 2.43 0.000 3.42 141 3.09 127 10 -130 J5 10 48 n- Propylbenzene 2.43 0.000 3.46 143 2.99 123 10 -130 J5 15 40 Naphthalene 2.43 0.000 3.38 140 3.22 133 0 -146 5.0 43 p- Isopropyltoluene 2.43 0.000 3.52 145 3.07 127 10 -131 J5 14 43 sec - Butylbenzene 2.43 0.000 3.30 136 2.86 118 10 -134 J5 14 43 Styrene 2.43 0.000 3.45 142 2.97 123 10 -140 J5 15 35 tert- Butylbenzene 2.43 0.000 3.31 137 2.89 119 11 -137 14 39 Tetrachloroethene 2.43 0.000 3.86 159 3.36 139 10 -131 J5 14 35 Toluene 2.43 0.000 2.96 122 2.56 106 12 -136 14 32 trans -1,2- Dichloroethene 2.43 0.000 3.28 135 2.91 120 10 -143 12 33 trans -1,3- Dichloropropene 2.43 0.000 2.86 118 2.54 105 16 -147 12 32 Trichloroethene 2.43 0.000 3.38 139 2.98 123 10 -155 13 33 Trichlorofluoromethane 2.43 0.000 2.29 94.6 1.95 80.5 10 -154 16 32 Vinyl chloride 2.43 0.000 3.06 126 2.70 112 10 -159 12 36 Xylenes, Total 7.28 0.000 9.85 135 8.59 118 10 -138 14 36 Quality Control Summary for client sample(s) SB -06 -1 OFT 61 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix. - mg/kg Project: Coppell Auto Center Project No.-940.002 Login No. Sample Number: L411486 -06 Sample Date:71812009 Extraction Date:7115 12009 Analysis Date:7115 12009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Analyte Spike LCS % Rec LCSD % Rec Control Limits % Qualifier RPD Control Limits Quali 1, 1, 1,2-Tetrachloroethane 0.050 0.050 101 0.058 115 73 -134 13 20 1, 1, 1 -Trichloroethane 0.050 0.047 94.0 0.051 101 62 -135 7.4 20 1,1,2,2 - Tetrachloroethane 0.050 0.055 111 0.061 121 74 -129 9.2 20 1,1,2 - Trichloroethane 0.050 0.052 105 0.058 115 77 -124 9.8 20 1,1,2 - Trichloro- 1,2,2- 0.050 0.045 90.2 0.051 102 49 -155 12 20 1,1- Dichloroethane 0.050 0.046 91.5 0.048 96.0 61 -134 4.8 20 1,1- Dichloroethene 0.050 0.049 97.7 0.054 109 53 -136 11 20 1, 1 -Dichloropropene 0.050 0.047 94.1 0.050 101 63 -132 6.8 20 1,2,3 - Trichlorobenzene 0.050 0.053 106 0.061 121 62 -146 13 20 1,2,3 - Trichloropropane 0.050 0.059 117 0.061 122 70 -133 3.5 20 1,2,3 - Trimethylbenzene 0.050 0.046 91.3 0.050 99.1 73 -126 8.2 20 1,2,4 - Trichlorobenzene 0.050 0.055 110 0.061 123 61 -148 11 20 1,2,4 - Trimethylbenzene 0.050 0.051 102 0.057 113 68 -135 10 20 1,2- Dibromo -3- Chloropropane 0.050 0.050 99.7 0.055 110 61 -134 10 21 1,2- Dibromoethane 0.050 0.052 105 0.057 114 76 -127 8.1 20 1,2- Dichlorobenzene 0.050 0.048 95.2 0.053 106 77 -123 10 20 1,2- Dichloroethane 0.050 0.044 87.2 0.046 92.1 58 -141 5.4 20 1,2- Dichloropropane 0.050 0.045 89.7 0.049 98.7 71 -128 9.5 20 1,3,5 - Trimethylbenzene 0.050 0.051 102 0.058 115 71 -133 13 20 1,3- Dichlorobenzene 0.050 0.052 105 0.060 121 71 -132 14 20 1,3- Dichloropropane 0.050 0.050 99.8 0.055 109 76 -120 8.8 20 1,4- Dichlorobenzene 0.050 0.048 95.6 0.052 104 72 -123 8.1 20 2,2- Dichloropropane 0.050 0.046 92.8 0.050 99.1 50 -147 6.6 20 2- Butanone (MEK) 0.250 0.253 101 0.252 101 51 -131 0.3 25 2- Chloroethyl vinyl ether 0.250 0.268 107 0.201 80.4 0 -188 29 39 2- Chlorotoluene 0.050 0.050 100 0.057 114 73 -128 13 20 4- Chlorotoluene 0.050 0.052 103 0.059 118 72 -129 13 20 4- Methyl -2- pentanone 0.250 0.275 110 0.284 113 61 -143 3.2 23 Acetone 0.250 0.253 101 0.247 98.8 44 -140 2.3 25 Acrylonitrile 0.250 0.261 104 0.261 104 55 -143 0.1 20 Benzene 0.050 0.046 92.3 0.050 99.8 65 -128 7.7 20 Bromobenzene 0.050 0.049 97.7 0.056 112 75 -123 13 20 Bromodichloromethane 0.050 0.046 91.4 0.050 101 66 -126 9.9 20 Bromoform 0.050 0.057 115 0.064 127 64 -139 10 20 Quality Control Summary for client sample(s) SB -06 -1 OFT 62 of 69 ftA Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No. Login No: L411486 Sample Number: L411486 -06 Sample Date:7 1812009 Extraction Date:711512009 Analysis Date: 7 /15/2009 2:38:00 PM Instrument ID: VOCGCMS5 Analyst: 140 Analytic Batch: WG431498 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Spike % % Control % Control Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali Bromomethane 0.050 0.048 96.1 0.050 99.8 41 -175 3.7 20 Carbon tetrachloride 0.050 0.046 92.3 0.050 99.0 60 -140 7.1 20 Chlorobenzene 0.050 0.052 103 0.056 112 75 -125 8.7 20 Chlorodibromomethane 0.050 0.054 109 0.059 119 72 -137 8.7 20 Chloroethane 0.050 0.050 99.2 0.051 103 44 -159 3.3 20 Chloroform 0.050 0.045 89.5 0.048 96.7 63 -123 7.7 20 Chloromethane 0.050 0.050 100 0.052 104 42 -149 3.7 20 cis -1,2- Dichloroethene 0.050 0.047 94.8 0.051 103 71 -129 7.9 20 cis -1,3 -Diehl oropropene 0.050 0.047 93.7 0.052 104 73 -132 11 20 Di- isopropyl ether 0.050 0.048 95.9 0.050 99.1 59 -143 3.3 20 Dibromomethane 0.050 0.047 94.1 0.050 101 70 -130 7.1 20 Dichlorodifluoromethane 0.050 0.056 111 0.059 118 26 -186 5.4 22 Ethylbenzene 0.050 0.051 103 0.057 114 74 -128 10 20 Hexachloro -1,3- butadiene 0.050 0.048 95.6 0.054 108 65 -137 12 20 Isopropylbenzene 0.050 0.052 104 0.058 116 73 -130 11 20 Methyl tert-butyl ether 0.050 0.047 94.6 0.048 95.1 44 -148 0.5 20 Methylene Chloride 0.050 0.044 88.3 0.047 93.5 57 -129 5.8 20 n- Butylbenzene 0.050 0.049 97.6 0.053 106 60 -145 8.2 20 n- Propylbenzene 0.050 0.051 102 0.059 117 71 -132 14 20 Naphthalene 0.050 0.055 109 0.060 119 61 -142 8.7 20 p- Isopropyltoluene 0.050 0.052 104 0.060 120 67 -138 14 20 sec - Butylbenzene 0.050 0.051 103 0.059 117 71 -134 14 20 Styrene 0.050 0.056 112 0.062 125 76 -133 11 20 tert- Butylbenzene 0.050 0.052 104 0.059 118 72 -132 12 20 Tetrachloroethene 0.050 0.051 102 0.057 114 65 -135 12 20 Toluene 0.050 0.046 92.0 0.051 103 70 -120 11 20 trans -1,2- Dichloroethene 0.050 0.047 94.7 0.051 102 61 -133 7.3 20 trans -1,3- Dichloropropene 0.050 0.043 85.3 0.046 91.9 70 -135 7.4 20 Trichloroethene 0.050 0.049 97.5 0.054 108 71 -126 9.9 20 Trichlorofluoromethane 0.050 0.048 95.3 0.049 98.0 52 -147 2.8 20 Vinyl chloride 0.050 0.054 107 0.055 110 50 -151 2.9 20 Xylenes, Total 0.150 0.156 104 0.176 117 74 -127 12 20 Quality Control Summary for client sample(s) SB -06 -1 OFT 63 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -01 Sample Date.-71812009 Extraction Date:711512009 Analysis Date:7115 12009 10:54:00 PM Instrument ID: VOCMS6 Analyst. Analytic Batch: WG431545 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Matrix Spike /Matrix Spike Duplicate L411401 -01 Spike % % % Control % Control Analyte Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali Benzene 0.050 0.047 94.3 0.047 94.4 65 -128 0.1 20 Methyl tert-butyl ether 0.050 0.053 106 0.051 101 44 -148 4.7 20 Toluene 0.050 0.049 97.7 0.048 96.6 70 -120 1.2 20 Matrix Spike /Matrix Spike Duplicate L411401 -01 Quality Control Summary for client sample(s) SB -0I -2FT 64 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Benzene 2.48 0.000 1.99 80.6 1.90 76.9 16 -143 4.7 31 Methyl tert-butyl ether 2.48 0.000 2.41 97.3 2.23 90.1 21 -157 7.8 31 Toluene 2.48 0.320 3.17 115 3.10 112 12 -136 2.2 32 Quality Control Summary for client sample(s) SB -0I -2FT 64 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Volatile Organic Compounds by Method 8260B L411486 Matrix. - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No. Sample Number: L411486 -01 Sample Date:7 1812009 Extraction Date.-711712009 Analysis Date:7 11712009 1:53:00 PM Instrument ID: VOCMS 18 Analyst.-73 Analytic Batch: WG431941 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Matrix Spike /Matrix Spike Duplicate L411666 -11 Spike % % Control % Control Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali Ethylbenzene 0.050 0.043 86.4 0.047 93.8 74 -128 8.2 20 Xylenes, Total 0.150 0.131 87.1 0.140 93.5 74 -127 7.1 20 Matrix Spike /Matrix Spike Duplicate L411666 -11 Quality Control Summary for client sample(s) SB- 01 -2FT 65 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Ethylbenzene 2.35 0.000 2.45 104 2.28 97.1 12 -137 7.0 36 Xylenes, Total 7.05 0.000 7.41 105 6.87 97.4 10 -138 7.7 36 Quality Control Summary for client sample(s) SB- 01 -2FT 65 of 69 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: TPH C6 - C35 by Method 8015 L411486 Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No: L411486 Sample Number: L411486 -03, -05, -06, -07, -08, -02, -09, -04, -01 Sample Date:7 1812009 Extraction Date:7 1912009 Analysis Date:711312009 12:35:00 PM Instrument ID: SVGC 13 Analyst.-287 Analytic Batch: WG430757 EPA ID: TN00003 Method Blank Analyte CAS PQL MDL TPH C12 - C28 <50.0 <25.0 TPH C28 - C35 <50.0 <25.0 TPH C6 - C12 <50.0 <25.0 TPH C6 - C35 <50.0 <25.0 Laboratory Control Sample (LCS) Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers TPH C12 - C28 250 248 99.1 75- 125 TPH C6 - C12 250 255 102 75- 125 TPH C6 - C35 500 502 100 75- 125 Laboratory Control Sample Duplicate (LCSD) Quality Control Summary for client sample(s) SB -03 -2FT, SB -05 -1 OFT, SB -06 -1 OFT, S13- 07 -8FT, SB -08 -1 OFT, SB -02 -2FT, SB- 09 -1 OFT, SB -04 -1 OFT, SB -OI -2FT 66 of 69 True Recovery Control Analyte Value Found % Limits Qualifiers TPH C12 - C28 250 278 111 75- 125 TPH C6 - C12 250 265 106 75- 125 TPH C6 - C35 500 543 109 75- 125 Quality Control Summary for client sample(s) SB -03 -2FT, SB -05 -1 OFT, SB -06 -1 OFT, S13- 07 -8FT, SB -08 -1 OFT, SB -02 -2FT, SB- 09 -1 OFT, SB -04 -1 OFT, SB -OI -2FT 66 of 69 �, Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test.- C6 - C35 by Method 8015 L411486 Matrix.- - mg /kg Project: Coppell Auto Center Project No.- 940.002 Login No. - L411486 Sample Number: L411486 -03, -05, -06, -07, -08, -02, -09, -04, -01 Sample Date:71812009 Extraction Date:71912009 Analysis Date:711312009 12:35:00 PM Instrument ID: SVGC13 Analyst.-287 Analytic Batch: WG430757 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Spike % % Control % Control Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali TPH C12 - C28 250 248 99.1 278 111 75 -125 11 20 TPH C6 - C12 250 255 102 265 106 75 -125 4.0 20 TPH C6 - C35 500 502 100 543 109 75 -125 7.8 20 Matrix Spike /Matrix Spike Duplicate L411699 -01 Quality Control Summary for client sample(s) SB -03 -2FT, SB -05 -LOFT, SB- 06 -1 OFT, SB- 07 -8FT, SB- 08 -1 OFT, SB -02 -2FT, SB -09 -1 OFT, SB- 04 -1OFT, SB -01 -2FT 67 of 69 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali TPH C12 - C28 250 0.000 287 115 281 112 75 -125 2.4 20 TPH C6 - C12 250 0.000 269 108 266 106 75 -125 1.3 20 TPH C6 - C35 500 0.000 557 111 547 109 75 -125 1.9 20 Quality Control Summary for client sample(s) SB -03 -2FT, SB -05 -LOFT, SB- 06 -1 OFT, SB- 07 -8FT, SB- 08 -1 OFT, SB -02 -2FT, SB -09 -1 OFT, SB- 04 -1OFT, SB -01 -2FT 67 of 69 Company Name/Address: W&M Environmental Group, Alternate billing information: Prese Chain ustpd Page of I Prepared by: F162 Inc.- Ft Worth 11 2 NW 24th St. Ste 201 Ptk D tz U ENVIRONMENTAL Fort Worth.TX 76164 l q SCIENCE CORP. 12065 Lebanon Road Report `T bo4 En*l to (-�VA -Yk Ot- Mt Juliet, TN 37122 J Phone(615)758 -5858 Project ickv/satc Desc. on: 0 Pti okoix co6cle d Ck Phone (800) 767-5859 Phone: (817) 378!06 1 Client Project ESC Key: FAX: FAX (615) 758-5859 Collected by: 1 Site /Facility I D#: P.O.* �e ;; : , Collected by (sign ure) Rush? MUST Be Notified i ede 111 d: Same Day.... Newt Dav 200 inno/. No. pH Flow Remarks/Contaminant I Sample (lab only) Temp Other )mpany N, address: W &M Environmental Group, Inc.- Ft Worth 112 NW 24th St. Ste 201 Fort Worth.TX 76164 Alternate billing information: Report to ff ry r f_ � / � � [� �,� y� f �9 51 i r, S n Y I 444 mail b: Lf ln/10�110ir±f(�OY.JrI��YA rn,.� me: (817) 398 C lectedby: lecteg by (�„tc)1#u Ably ontca N_ Y1 Sample ID 7"9 - /3 °]— In Client Project #: ESC Key: Chh Cust Pagef Site/Facility ID #: P.O. #: RushT { Lab MUST Be Notified ) Same Day ....... 200% Next Day........ 100% Two Day........ 50% Three Day. . . .... 25% Comp /Grab MatrW Depth ,( .1 t ua es aeu: No. Email? _No_rYes (( of FAX? J2do Yes Cntrs Date I Time n K't 'Matrix. SS- SoiVSolid GW- Groundwater NWIi - WasteWater DW -Drinking Water OT-Other pH Temp Remarks: Flow Other Chh Cust Pagef , flab V o Prepared by: ENVIRONMENTAL SCIENCE CORP. RemarkslContaminant Sample # (lab only) 12065 Lebanon Road :. Mt. Juliet, TN 37122 i Phone (615) 758 -5858 Phone (800) 767 -5859 FAX (615) 758 -5859 'Matrix. SS- SoiVSolid GW- Groundwater NWIi - WasteWater DW -Drinking Water OT-Other pH Temp Remarks: Flow Other flab V o RemarkslContaminant Sample # (lab only) 'Matrix. SS- SoiVSolid GW- Groundwater NWIi - WasteWater DW -Drinking Water OT-Other pH Temp Remarks: Flow Other Environmental Science Corporation Mount Juliet, TN For: W &M Environmental Group, Inc,. -`FtWorth Cpppell Auto Center L413297 (615) 758 -5858 1- 800 -767 -5859 Fax (615) 758 -5859 EST. 1970 1 of 18 Appendix A Laboratory Data Package Cover Page This data package consists of: This signature page, the laboratory review checklist, and the following reportable data: R1 Field chain -of- custody documentation; R2 Sample identification cross- reference; R3 Test reports (analytical data sheets) for each environmental sample that includes: a) Items consistent with NELAC 5.13 or ISO /IEC 17025 Section 5.10 b) dilution factors, c) preparation methods, d) cleanup methods, and e) if required for the project, tentatively identified compounds (TICS). R4 Surrogate recovery data including: a) Calculated recovery ( %R), and b) The laboratory's surrogate QC limits. R5 Test reports /summary forms for blank samples; R6 Test reports /summary forms for laboratory control samples (LCSs) including: a) LCS spiking amounts, b) Calculated %R for each analyte, and c) The laboratory's LCS QC limits. R7 Test reports for project matrix spike /matrix spike duplicates (MS/MSDs) including: a) Samples associated with the MS/MSD clearly identified, b) MS/MSD spiking amounts, c) Concentration of each MS/MSD analyte measured in the parent and spiked samples, d) Calculated %Rs and relative percent differences (RPDs), and e) The laboratory's MS/MSD QC limits R8 Laboratory analytical duplicate (if applicable) recovery and precision: a) the amount of analyte measured in the duplicate, b) the calculated RPD, and c) the laboratory's QC limits for analytical duplicates. R9 List of method quantitation limits (MQLs) for each analyte for each method and matrix; R10 Other problems or anomalies. The Exception Report for every "No" or "Not Reviewed (NR)" item in laboratory review checklist. Release Statement: I am responsible for the release of this laboratory data package. This data package has been reviewed by the laboratory and is complete and technically compliant with the requirements of the methods used, except where noted by the laboratory in the attached exception reports. By my signature below, I affirm to the best of my knowledge, all problems /anomalies, observed by the laboratory as having the potential to affect the quality of the data, have been identified by the laboratory in the Laboratory Review Checklist, and no information or data have been knowingly withheld that would affect the quality of the data. Check, if applicable: [ ] This laboratory is an in -house laboratory controlled by the person responding to rule. The official signing the cover page of the rule- required report (for example, the APAR) in which these data are used is responsible for releasing this data package and is by signature affirming the above release statement is true. William Mock Operations Manager Environmental Science Corp. RG-3 66/TRRP- 13 December 2002 2 oM$ Appendix A (cont'd): Laboratory Review Checklist: Reportable Data Laboratory Name:Environmental Science LRC Date: 07/24/09 Project Name: Coppell Auto Center Laboratory Job Number: L41 329 7-01 Reviewer Name: ESC Representative Prep Batch Number(s): WG430721 TS # A Z Descri lion Yes No NA NR 4 ER# Chain -of- custody (C -O -C) RI OI Did samples meet the laboratory's standard conditions of sample acceptability upon receipt? Were all departures from standard conditions described in an exception report? R2 OI Sample and quality control (QQ identification Are all field sample ID numbers cross - referenced to the laboratory ID numbers? Are all laboratory ID numbers cross - referenced to the corresponding QC data? R3 OI Test reports Were all samples prepared and analyzed within holding times? Other than those results < MQL, were all other raw values bracketed by calibration standards? AL I — Were calculations checked by a peer or supervisor? Were all analyte identifications checked by a peer or supervisor? Were sample quantitation limits reported for all anal tes not detected? Were all results for soil and sediment samples reported on a dry weight basis? Were % moisture (or solids) reported for all soil and sediment samples? If required for the project, TICs reported? R4 O Surrogate recovery data Were surrogates added prior to extraction? Were surrogate percent recoveries in all samples within the laboratory C limits? R5 OI Test reports/summary reports/summary forms for blank samples Were appropriate type(s) of blanks analyzed? Were blanks analyzed at the appropriate frequency? Were method blanks taken through the entire analytical process, including preparation and, if applicable, cleanup procedures? Were blank concentrations < M L? R6 OI Laboratory control samples (LCS): Were all COCs included in the LCS? Was each LCS taken through the entire analytical procedure, including re and cleanup steps? Were LCSs analyzed at the required frequency? Were LCS (and LCSD, if applicable) %Rs within the laboratory QC limits? Does the delectability data document the laboratory's capability to detect the COCs at the MDL used to calculate the SQLs? Was the LCSD RPD within QC limits? R7 OI Matrix spike MS and matrix spike duplicate MSD data Were the project/method specified anal es included in the MS and MSD? Were MS /MSD analyzed at the appropriate fre uenc ? Were MS (and MSD, if applicable) %Rs within the laboratory QC limits? Were MS/MSD RPDs within laboratory QC limits? RS 1 01 1 Anal tical duplicate data Were appropriate anal ical duplicates analyzed for each matrix? Were analytical duplicates analyzed at the appropriate fre uenc ? Were RPDs or relative standard deviations within the laboratory QC limits? R9 OI Method quantitation limits (MQLs): Are the MQLs for each method anal to included in the laboratory data package? Do the MQLs correspond to the concentration of the lowest non -zero calibration standard? Are unadjusted MQLs included in the laboratory data package? R10 OI Other problems/anomalies Are all known problems/anomalies/special conditions noted in this LRC and ER? Were all necessary corrective actions performed for the reported data? Was applicable and available technology used to lower the SQL minimize the matrix interference affects on the sample results? 1. Items identified by the letter "R" must be included in the laboratory data package submitted in the TRRP- required report(s). Items identified by the letter "S" should be retained and made available upon request for the appropriate retention period. 2. = organic analyses; I = inorganic analyses (and general chemistry, when applicable); 3. NA = Not applicable; 4. NR = Not reviewed; 5. ER# = Exception Report identification number (an Exception Report should be completed for an item if "NR" or "No" is checked). RG-3 66/TRRP- 13 December 2002 3 of 48 Appendix A (cont'd): Laboratory Review Checklist: Reportable Data Laboratory Name:Environmental Science LRC Date: 07/24/09 Project Name: Coppell Auto Center Laboratory Job Number:L413297 -01 Reviewer Name: ESC Representative Prep Batch Number(s): WG432501 SV8270PAH # A Description Yes No NA NR ER# Chain -of- custody (C -O -C) RI OI Did samples meet the laboratory's standard conditions of sample acceptability upon receipt? Were all departures from standard conditions described in an exception report? R2 OI Sample and quality control (QQ identification Are all field sample ID numbers cross - referenced to the laboratory ID numbers? Are all laboratory ID numbers cross - referenced to the corresponding QC data? R3 01 Test reports Were all samples prepared and analyzed within holding times? Other than those results < MQL, were all other raw values bracketed by calibration standards? Were calculations checked by a peer or supervisor? Were all analyte identifications checked by a peer or supervisor? Were sample quantitation limits reported for all anal es not detected? Were all results for soil and sediment samples reported on a dry weight basis? Were % moisture (or solids) reported for all soil and sediment samples? If required for the project, TICS reported? R4 0 Surro ate recovery data Were surrogates added prior to extraction? Were surrogate percent recoveries in all samples within the laboratory C limits? R5 OI Test reports/summary reports/summary forms for blank samples Were appropriate type(s) of blanks analyzed? Were blanks analyzed at the appropriate fre uenc ? Were method blanks taken through the entire analytical process, including preparation and, if applicable, cleanup procedures? Were blank concentrations < MQL? R6 OI Laboratory control samples (LCS): Were all COCs included in the LCS? Was each LCS taken through the entire analytical procedure, including re and cleanup steps? Were LCSs analyzed at the required frequency? Were LCS (and LCSD, if applicable) %Rs within the laboratory QC limits? Does the detectability data document the laboratory's capability to detect the COCs at the MDL used to calculate the SQLs? Was the LCSD RPD within QC limits? R7 101 IMatrix spike MS and matrix spike duplicate MSD data Were the project/method specified anal es included in the MS and MSD? Were MS /MSD analyzed at the appropriate fre uenc ? Were MS (and MSD, if applicable) %Rs within the laboratory QC limits? Were MS /MSD RPDs within laboratory QC limits? RH OI Analytical duplicate data Were appropriate anal ical duplicates analyzed for each matrix? Were anal ical duplicates analyzed at the appropriate fre uenc ? Were RPDs or relative standard deviations within the laboratory QC limits? R9 OI Method quantitation limits (MQLs): -- - Are the MQLs for each method analyte included in the laboratory data package? Do the MQLs correspond to the concentration of the lowest non -zero calibration standard? Are unadjusted MQLs included in the laboratory data package? R10 OI Other problems/anomalies Are all known problems/anomalies/special conditions noted in this LRC and ER? Were all necessary corrective actions performed for the reported data? Was applicable and available technology used to lower the SQL minimize the matrix interference affects on the sample results? 1. Items identified by the letter "R" must be included in the laboratory data package submitted in the TRRP- required report(s). Items identified by the letter "S" should be retained and made available upon request for the appropriate retention period. 2. = organic analyses; I = inorganic analyses (and general chemistry, when applicable); 3. NA = Not applicable; 4. NR = Not reviewed; 5. ER# = Exception Report identification number (an Exception Report should be completed for an item if "NR" or "No" is checked). RG-3 66/TRRP- 13 December 2002 4 of AS ENVIRONMENTAL SCIENCE CORP. Teal Chiabotti W &M Environmental Group, Inc.- Ft Worth 112 NW 24th St, Ste 201 Fort Worth, TX 76164 12065 Lebanon Rd. Mt. Juliet, TN 37122 (615) 758 -5858 1- 800 - 767 -5859 Fax (615) 758 -5859 Tax I.D. 62- 0814289 Est. 1970 Report Summary Thursday July 23, 2009 Report Number: L413297 Samples Received: 07/09/09 Client Project: 940.002 Description: Coppell Auto Center The analytical results in this report are based upo informa ion su plie by you, the client, and are for your exclusive use ou ave a questions regarding this data package, please do o ita e to 1. Entire Report Reviewed By: Laboratory Certification Numbers r eas ey, ZSC Rep/ sen a ive A2LA - 1461 -01, AIHA - 100789, AL - 40660, CA - I -2327, CT - PH -0197, FL - E87487 GA - 923, IN - C- TN -01, KY - 90010, KYUST - 0016, NC - ENV375,DW21704, ND - R -140 NJ - TN002, NJ NELAP - TN002, SC - 84004, TN - 2006, VA - 00109, WV - 233 AZ - 0612, MN - 047- 999 -395, NY - 11742, WI - 998093910 Accreditation is only applicable to the test methods specified on each scope of accreditation held by ESC Lab Sciences. This report may not be reproduced, except in full, without written approval from Environmental Science Corp. Where applicable, sampling conducted by ESC is performed per guidance provided in laboratory standard operating procedures: 060302, 060303, and 060304. 1 Samples Reported: 07/23/09 13:52 Printed: 07/23/09 13:53 Page 1 of 4 5of18 ENVIRONMENTAL SCIENCE CORP. 12065 Lebanon Rd. Mt. Juliet, TN 37122 (615) 758 -5858 1- 800 - 767 -5859 Fax (615) 758 -5859 Tax I.D. 62- 0814289 Teal Chiabotti W &M Environmental Group, Inc.- Ft W 112 NW 24th St, Ste 201 Fort Worth, TX 76164 REPORT OF ANALYSIS July 23,2009 Est. 1970 Results listed are dry weight basis. U = ND (Not Detected) MDL Minimum Detection Limit = LOD RDL = Reported Detection Limit = LOQ = PQL = EQL Note: This report shall not be reproduced, except in full, without the written approval from ESC. The reported analytical results relate only to the sample submitted Reported: 07/23/09 13:52 Printed: 07/23/09 13:53 Page 2 of 4 6of18 ESC Sample # L413297 - 01 Date Received July 09, 2009 Description Coppell Auto Center Site ID Sample ID SB- 01 -2FT Project # 940.002 Collected By Teal Chiabotti Collection Date 07/08/09 09:45 Parameter Dry Result MDL RDL Units Q Method Date Dil. Total Solids 81.0 % 2540G 07/13/09 1 Polynuclear Aromatic Hydrocarbons Anthracene 0.34 0.0080 0.041 mg /kg 8270C 07/22/09 1 Acenaphthene 0.14 0.010 0.041 mg /kg 8270C 07/22/09 1 Acenaphthylene 0.037 0.010 0.041 mg /kg J 8270C 07/22/09 1 Benzo(a)anthracene 0.012 0.0086 0.041 mg /kg J 8270C 07/22/09 1 Benzo(a)pyrene U 0.0092 0.041 mg /kg 8270C 07/22/09 1 Benzo(b)fluoranthene U 0.013 0.041 mg /kg 8270C 07/22/09 1 Benzo(g,h,i)perylene U 0.0089 0.041 mg /kg 8270C 07/22/09 1 Benzo(k)fluoranthene U 0.011 0.041 mg /kg 8270C 07/22/09 1 Chrysene U 0.011 0.041 mg /kg 8270C 07/22/09 1 Dibenz(a,h)anthracene U 0.0093 0.041 mg /kg 8270C 07/22/09 1 Fluoranthene 0.020 0.0076 0.041 mg /kg J 8270C 07/22/09 1 Fluorene 0.30 0.011 0.041 mg /kg 8270C 07/22/09 1 Indeno(1,2,3- cd)pyrene U 0.0099 0.041 mg /kg 8270C 07/22/09 1 Naphthalene 1.4 0.0081 0.041 mg /kg 8270C 07/22/09 1 Phenanthrene 1.2 0.0087 0.041 mg /kg 8270C 07/22/09 1 Pyrene 0.22 0.010 0.041 mg /kg 8270C 07/22/09 1 Surrogate Recovery Nitrobenzene -d5 78.1 % Rec. 8270C 07/22/09 1 2- Fluorobiphenyl 67.7 % Rec. 8270C 07/22/09 1 p- Terphenyl -dl4 113. % Rec. 8270C 07/22/09 1 Results listed are dry weight basis. U = ND (Not Detected) MDL Minimum Detection Limit = LOD RDL = Reported Detection Limit = LOQ = PQL = EQL Note: This report shall not be reproduced, except in full, without the written approval from ESC. The reported analytical results relate only to the sample submitted Reported: 07/23/09 13:52 Printed: 07/23/09 13:53 Page 2 of 4 6of18 Attachment A List of Analytes with QC Qualifiers Sample Number L413297 -01 Work Sample Group Type Analyte WG432501 SAMP Acenaphthylene WG432501 SAMP Benzo(a)anthracene WG432501 SAMP Fluoranthene Run ID 8832326 R832326 8832326 Qualifier Page 3 of 4 7of18 Attachment B Explanation of QC Qualifier Codes Qualifier Meaning J (EPA) - Estimated value below the lowest calibration point. Confidence correlates with concentration. Qualifier Report Information ESC utilizes sample and result qualifiers as set forth by the EPA Contract Laboratory Program and as required by most certifying bodies including NELAC. In addition to the EPA qualifiers adopted by ESC, we have implemented ESC qualifiers to provide more information pertaining to our analytical results. Each qualifier is designated in the qualifier explanation as either EPA or ESC. Data qualifiers are intended to provide the ESC client with more detailed information concerning the potential bias of reported data. Because of the wide range of constituents and variety of matrices incorporated by most EPA methods,it is common for some compounds to fall outside of established ranges. These exceptions are evaluated and all reported data is valid and useable unless qualified as 'R' (Rejected). Definitions Accuracy - The relationship of the observed value of a known sample to the true value of a known sample. Represented by percent recovery and relevant to samples such as: control samples, matrix spike recoveries, surrogate recoveries, etc. Precision - The agreement between a set of samples or between duplicate samples. Relates to how close together the results are and is represented by Relative Percent Differrence. Surrogate - Organic compounds that are similar in chemical composition, extraction, and chromotography to analytes of interest. The surrogates are used to determine the probable response of the group of analytes that are chem- ically related to the surrogate compound. Surrogates are added to the sample and carried through all stages of preparation and analyses. TIC - Tentatively Identified Compound: Compounds detected in samples that are not target compounds, internal standards, system monitoring compounds, or surrogates. Page 4 of 4 8of18 Summary of Remarks For Samples Printed 07/23/09 at 13:53:14 TSR Signing Reports: 134 R5 - Desired TAT Sample: L413297 -01 Account: WMENVFTX Received: 07/09/09 09:00 Due Date: 07/24/09 00:00 RPT Date: 07/23/09 13:52 Relogged from L411486 -01 9of18 Environmental Science Corporation Quality Control Summary Q t3' Y W &M Environmental Group, Inc.- Ft Worth Test.-Total Solids by Method 254OG L413297 Matrix.-Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No: L413297 Sample Number: L413297 -01 Sample Date:7 1812009 Extraction Date:7 1912009 Analysis Date:7 11312009 11:13:00 AM Instrument ID: BAL Analyst. Analytic Batch: WG430721 EPA ID: TN00003 Method Blank Analyte CAS Results Total Solids 0.000 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Total Solids 50.0 50.0 100 85-115 Quality Control Summary for client sample(s) SB -OI -2FT 10 of 18 Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Total Solids by Method 2540G L413297 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No.-L413297 Sample Number: L413297 -01 Sample Date: 7/8/2009 Extraction Date:7 1912009 Analysis Date.-711312009 11:13:00 AM Instrument ID: BAL Analyst: 469 Analytic Batch: WG430721 EPA ID: TN00003 Sample Duplicate L411486 -01 Sample Results Name Results Duplicate %RPD Limit Qualifiers Total Solids 81.0 81.1 0.1 5 Quality Control Summary for client sample(s) SB- 0I -2FT 11 of 18 Environmental Science Corporation Quality Control Summary Q t3' Y W &M Environmental Group, Inc.- Ft Worth Test: Semi - Volatiles by Method 8270C Matrix.-Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No: L413297 Sample Number: L413297 -01 Sample Date: 71812009 Extraction Date:7 12112009 Analysis Date:712212009 Instrument ID: SVGCMS6 L413297 Analyst. Analytic Batch: WG432501 EPA ID: TN00003 Method Blank CAS POL MDL Naphthalene 91 -20 -3 <0.033 <0.0081 Acenaphthylene 208 -96 -8 <0.033 <0.0100 Acenaphthene 83 -32 -9 <0.033 <0.0100 Fluorene 86 -73 -7 <0.033 <0.0110 Phenanthrene 85 -01 -8 <0.033 <0.0087 Anthracene 120 -12 -7 <0.033 <0.0080 Fluoranthene 206 -44 -0 <0.033 <0.0076 Pyrene 129 -00 -0 <0.033 <0.0100 Benzo(a)anthracene 56 -55 -3 <0.033 <0.0086 Chrysene 218 -01 -9 <0.033 <0.0110 Benzo(b)fluoranthene 205 -99 -2 <0.033 <0.0130 Benzo(k)fluoranthene 207 -08 -9 <0.033 <0.0110 Benzo(a)pyrene 50 -32 -8 <0.033 <0.0092 Indeno(1,2,3- cd)pyrene 193 -39 -5 <0.033 <0.0099 Dibenz(a,h)anthracene 53 -70 -3 <0.033 <0.0093 Benzo(g,h,i)perylene 191 -24 -2 <0.033 <0.0089 Quality Control Summary for client sample(s) S13- 01 -2FT 12 of 18 Environmental Science Corporation Quality Control Summary Q tY Y W &M Environmental Group, Inc.- Ft Worth Test: Semi - volatile Organic Compounds by Method 8270C Matrix: Soil - mg /kg Project: Coppell Auto Center Project No: 940.002 Login No. Sample Number: L413297 -01 Sample Date: 71812009 Extraction Date:7 12112009 Analysis Date. 4:57:00 PM Instrument ID: SVGCMS6 L413297 Analyst: 279 Analytic Batch: WG432501 EPA ID: TN00003 Laboratory Control Sample (LCS) True Recovery Control Analyte Value Found % Limits Qualifiers Acenaphthene 0.167 0.136 81.3 44-117 Acenaphthylene 0.167 0.135 80.7 43- 118 Anthracene 0.167 0.135 80.7 42- 127 Benzo(a)anthracene 0.167 0.127 76.2 45- 127 Benzo(a)pyrene 0.167 0.121 72.2 46- 123 Benzo(b)fluoranthene 0.167 0.102 60.9 43- 126 Benzo(g,h,i)perylene 0.167 0.143 85.8 43- 128 Benzo(k)fluoranthene 0.167 0.135 80.6 40- 126 Chrysene 0.167 0.130 78.1 44- 129 Dibenz(a,h)anthracene 0.167 0.140 83.6 43- 127 Fluoranthene 0.167 0.141 84.7 44- 125 Fluorene 0.167 0.134 80.4 45- 121 Indeno(1,2,3- cd)pyrene 0.167 0.145 86.7 43- 127 Naphthalene 0.167 0.119 71.1 32- 113 Phenanthrene 0.167 0.127 76.3 43- 124 Pyrene 0.167 0.134 80.1 47- 128 Quality Control Summary for client sample(s) SB- 01 -2FT 13 of 18 uA Environmental Science Corporation Quality Control Summary W &M Environmental Group, Inc.- Ft Worth Test: Semi - volatile Organic Compounds by Method 8270C L413297 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No: 940.002 Login No: L413297 Sample Number: L413297 -01 Sample Date:7 /8/2009 Extraction Date:7 12112009 Analysis Date. 4:57:00 PM Instrument ID: SVGCMS6 Analyst.-279 Analytic Batch: WG432501 EPA ID: TN00003 Laboratory Control Sample Duplicate (LCSD) True Recovery Control Analyte Value Found % Limits Qualifiers Acenaphthene 0.167 0.136 81.5 44- 117 Acenaphthylene 0.167 0.131 78.5 43-118 Anthracene 0.167 0.148 88.7 42-127 Benzo(a)anthracene 0.167 0.140 83.6 45- 127 Benzo(a)pyrene 0.167 0.137 81.9 46-123 Benzo(b)fluoranthene 0.167 0.118 70.5 43- 126 Benzo(g,h,i)perylene 0.167 0.168 101 43-128 Benzo(k)fluoranthene 0.167 0.149 89.3 40-126 Chrysene 0.167 0.144 86.5 44-129 Dibenz(a,h)anthracene 0.167 0.162 96.9 43- 127 Fluoranthene 0.167 0.157 93.9 44- 125 Fluorene 0.167 0.138 82.8 45- 121 Indeno(1,2,3- cd)pyrene 0.167 0.169 101 43- 127 Naphthalene 0.167 0.108 65.0 32- 113 Phenanthrene 0.167 0.139 83.0 43- 124 Pyrene 0.167 0.144 86.3 47- 128 Quality Control Summary for client sample(s) SB- 0I -2FT 14 of 18 Environmental Science Corporation Quality Control Summary Q tY Y W &M Environmental Group, Inc.- Ft Worth Test: Semi - volatile Organic Compounds by Method 8270C L413297 Matrix: Soil - mg/kg Project: Coppell Auto Center Project No.-940.002 Login No: L413297 Sample Number: L413297 -01 Sample Date:7 1812009 Extraction Date:712112009 Analysis Date:712212009 4:57:00 PM Instrument ID: SVGCMS6 Analyst: 279 Analytic Batch: WG432501 EPA ID: TN00003 Matrix Spike /Matrix Spike Duplicate L413259 -05 Quality Control Summary for client sample(s) SB- 0I -2FT 15 of 18 Spike % % Control % Control Analyte Value Sample MS Rec MSD Rec Limits Qualifier RPD Limits Quali Acenaphthene 0.167 0.00000 0.120 71.7 0.119 71.0 38 -121 1.0 23 Acenaphthylene 0.167 0.00000 0.116 69.3 0.117 70.0 39 -120 0.9 22 Anthracene 0.167 0.00000 0.129 77.0 0.140 83.9 35 -133 8.6 23 Benzo(a)anthracene 0.167 0.00000 0.123 73.9 0.136 81.4 35 -136 9.6 23 Benzo(a)pyrene 0.167 0.00000 0.118 70.9 0.130 77.7 37 -131 9.1 22 Benzo(b)fluoranthene 0.167 0.00000 0.0953 57.1 0.120 71.9 29 -145 23 33 Benzo(g,h,i)perylene 0.167 0.00000 0.145 86.7 0.164 97.9 10 -139 12 26 Benzo(k)fluoranthene 0.167 0.00000 0.126 75.6 0.130 77.9 31 -140 3.0 34 Chrysene 0.167 0.00000 0.124 74.0 0.141 84.3 34 -137 13 23 Dibenz(a,h)anthracene 0.167 0.00000 0.139 83.3 0.155 92.6 21 -132 11 25 Fluoranthene 0.167 0.00000 0.138 82.4 0.154 92.1 34 -132 11 24 Fluorene 0.167 0.00000 0.120 71.9 0.129 77.0 38 -126 6.8 23 Indeno(1,2,3- cd)pyrene 0.167 0.00000 0.144 86.5 0.163 97.7 17 -134 12 25 Naphthalene 0.167 0.00000 0.0911 54.5 0.0802 48.0 24 -122 13 29 Phenanthrene 0.167 0.00000 0.121 72.7 0.136 81.6 38 -128 11 25 Pyrene 0.167 0.00000 0.129 77.0 0.139 83.2 35 -141 7.7 25 Quality Control Summary for client sample(s) SB- 0I -2FT 15 of 18 Environmental Science Corporation Quality Control Summary Q t3' Y W &M Environmental Group, Inc.- Ft Worth Test: Semi - volatile Organic Compounds by Method 8270C L413297 Matrix. - mg /kg Project: Coppell Auto Center Project No. Login No. Sample Number: L413297 -01 Sample Date: 7/8/2009 Extraction Date: 712112009 Analysis Date:712212009 4:57:00 PM Instrument ID: SVGCMS6 Analyst: 279 Analytic Batch: WG432501 EPA ID: TN00003 Laboratory Control Sample/ Laboratory Control Sample Duplicate Spike % % Control % Control Analyte LCS Rec LCSD Rec Limits Qualifier RPD Limits Quali Acenaphthene 0.167 0.136 81.3 0.136 81.5 44 -117 0.2 21 Acenaphthylene 0.167 0.135 80.7 0.131 78.5 43 -118 2.8 20 Anthracene 0.167 0.135 80.7 0.148 88.7 42 -127 9.4 21 Benzo(a)anthracene 0.167 0.127 76.2 0.140 83.6 45 -127 9.3 21 Benzo(a)pyrene 0.167 0.121 72.2 0.137 81.9 46 -123 13 20 Benzo(b)fluoranthene 0.167 0.102 60.9 0.118 70.5 43 -126 15 27 Benzo(g,h,i)perylene 0.167 0.143 85.8 0.168 101 43 -128 16 20 Benzo(k)fluoranthene 0.167 0.135 80.6 0.149 89.3 40 -126 10 32 Chrysene 0.167 0.130 78.1 0.144 86.5 44 -129 10 22 Dibenz(a,h)anthracene 0.167 0.140 83.6 0.162 96.9 43 -127 15 20 Fluoranthene 0.167 0.141 84.7 0.157 93.9 44 -125 10 22 Fluorene 0.167 0.134 80.4 0.138 82.8 45 -121 2.9 20 Indeno(1,2,3- cd)pyrene 0.167 0.145 86.7 0.169 101 43 -127 15 21 Naphthalene 0.167 0.119 71.1 0.108 65.0 32 -113 9.0 26 Phenanthrene 0.167 0.127 76.3 0.139 83.0 43 -124 8.4 21 Pyrene 0.167 0.134 80.1 0.144 86.3 47 -128 7.4 20 Quality Control Summary for client sample(s) SB- 01 -2FT 16 of 18 oinparry ress: Alternate baling information: 7. W &M Environmental Group, Inc.- Ft Worth': x _. i 112 NW 24th St. Ste 241 ,� �kKO C-4— Fort Worth.TX 76164 4 I Report �tC.(/N Project C ity/sae Description: k C ohecxd _ Phone: (819)378 12 Client Project #: ESC Key: t FAX: v J Colleded by: J SitelFaciiity ID#: P.OA 'r Collected by (sign /�_ture): ,� Rush? { Lab MUST Be Notified) Same Day ....... 200% D e s�p�eded: D _t No. .cam �• . D. r Th 'Matrix SS- 5oi /VSolid GW / -OG�� , wndwater M- WasteWater DW- Drinking Water 07-Other_ Remarks: /��Lag9Qfif L c//y "m L ?V, 1 Chain of u Page of Prepared by: F162 ENVIRONMENTAL SCIENCE CORP. I2065 Lebanon Road Mt Juliet, IN 37122 Phone (615) 758 -5858 Phone (800) 767 -5859 FAX (615) 758 -5859 Remark&Contanrn" Sample (lab only) y13 2It ?- 0� ptFaT f� Pl S 9I'r� 1 pH Flow Temp Other Jonah Huckabay L W I V1 From: Mark Beasley Sent: Tuesday, July 21, 2009 8:46 AM To: Login; Sample Storage Subject: L411486 *WMENVFTX' relog Relog L411486 -01 for SV8270PAH. Transfer TS results. Log as R5 due 7/24. Thanks Mark Beasley ESC Lab Sciences Direct Phone: (615) 773 -9672 Tall -free: 1-800 -767 -5859 ext 9672 Email: mbeasley@esciabsciences.com This E -mail and any attached files are confidential, and may be copyright protected. If you are not the addressee, any dissemination of this communication Is strictly prohibited. If you have received this message in error, please contact the sender immediately and delete /destroy all information received. 0 ip r� �J 9 OXIDOR Laboratory Review Checklist Cover Page Project Name: 940.002.003 Coppell Auto Ctr. W. Bethel Rd - Coppell OXIDOR Job Number: 0910331 W &M Environmental Group, Inc. This data ackage consists of: X This signature page, the laboratory review checklist, and the following reportable data: X R1 Field chain -of- custody documentation; X R2 Sample identification cross - reference; X R3 Test reports (analytical data sheets) for each environmental sample that includes: XQ R4 dX R5 R6 X❑ R7 XD R8 X X X R9 R10 a) Items consistent with NELAC 5.13 or ISO /IEC 17025 Section 5.10 b) dilution factors, c) preparation methods, d) cleanup methods, and e) if required for the project, tentatively identified compounds (TICs). Surrogate recovery data including: a) Calculated recovery ( %R), and b) The laboratory's surrogate QC limits. Test reports /summary forms for blank samples; Test reports /summary forms for laboratory control samples (LCSs) including: a) LCS spiking amounts, b) Calculated %R for each analyte, and c) The laboratory's LCS QC limits. Test reports for project matrix spike /matrix spike duplicates (MS /MSDs) including: a) Samples associated with the MS /MSD clearly identified, b) MS /MSD spiking amounts, c) Concentration of each MS /MSD analyte measured in the parent and spiked samples, d) Calculated %Rs and relative percent differences (RPDs), and e) The laboratory's MS /MSD QC limits Laboratory analytical duplicate (if applicable) recovery and precision: a) the amount of analyte measured in the duplicate, b) the calculated RPD, and c) the laboratory's QC limits for analytical duplicates. List of method quantitation limits (MQLs) for each analyte for each method and matrix; Other problems or anomalies. The Exception Report for every "No" or "Not Reviewed (NR)" item in laboratory review checklist. Release Statement: I am responsible for the release of this laboratory data package. This data package has been reviewed by the laboratory and is complete and technically compliant with the requirements of the methods used, except where noted by the laboratory in the attached exception reports. By my signature below, I affirm to the best of my knowledge, all problems /anomalies, observed by the laboratory as having the potential to affect the quality of the data, have been identified by the laboratory in the Laboratory Review Checklist, and no information or data have been knowingly withheld that would affect the quality of the data. Charles Brungardt Name Oxidor Laboratory Review Checklist Rev. 1.1, 072803 � _ Signature 0 C (� President Official Title October 27, 2009 Date Page 1 of 4 OXIDOR Laboratory Review Checklist: Reportable Data Laboratory Name: OXIDOR Laboratories, LLC LRC Date: October 27, 2009 Project Name: 940.002.003 Coppell Auto Ctr. I Laboratory Job Number: 0910331 W &M Environmental Group, Inc. Reviewer Name: Kyra Crutchfield JQC Batch Number(s): See Cross - reference List #' A Description Yes No NA' NR ER # R1 OI Chain -of- Custody (C -O -C) Did samples meet the laboratory's standard conditions of sample acceptability upon receipt? X Were all departures from standard conditions described in an exception report? X R2 OI Sample and quality control (QC) identification Are all field sample ID numbers cross - referenced to the laboratory ID numbers? X Are all laboratory ID numbers cross - referenced to the corresponding QC data? X R3 OI Test reports ; Were all samples prepared and analyzed within holding times? X Other than those results < MDL, were all other raw values bracketed by calibration standards? X Were calculations checked by a peer or supervisor? X Were all analyte identifications checked by a peer or supervisor? X Were sample quantitation limits reported for all analytes not detected? X Were all results for soil and sediment samples reported on a dry weight basis? X Were % moisture (or solids) reported for all soil and sediment samples? X If required for the project, TICs reported? X R4 O Surrogate recovery data w Were surrogates added prior to extraction? X Were surrogate recoveries in all samples within the laboratory QC limits? X R5 OI Test reports /summary forms for blank samples Were appropriate type(s) of blanks analyzed? X Were blanks analyzed at the required frequency? X Were method blanks taken through the entire analytical process, including preparation and, if applicable, cleanup procedures? X Were blank concentrations < MQL? X R6 OI Laboratory control samples (LCS): 3 5 Were all COCs included in the LCS? X Was each LCS taken through the entire analytical procedure, including prep and cleanup steps? X Were LCSs analyzed at the required frequency? X Were LCS (and LCSD, if applicable) %Rs within the laboratory QC limits? X Does the detectability data document the laboratory's capability to detect the COCs at the MDL used to calculate the SQLs? X Was the LCSD RPD within QC limits? X R7 Of Matrix spike (MS) and matrix spike duplicate (MSD) data °' Were the project/method specified analytes included in the MS and MSD? X Were MS /MSD analyzed at the appropriate frequency? X Were MS (and MSD, if applicable) %Rs within the laboratory QC limits? X ER #1 Were MS /MSD RPDs within laboratory QC limits? X R8 01 Analytical duplicate data .;. Were appropriate analytical duplicates analyzed for each matrix? X Were analytical duplicates analyzed at the appropriate frequency? X Were RPDs or relative standard deviations within the laboratory QC limits? X R9 OI Method quantitation limits( MQLs): " Are the MQLs for each method analyte included in the laboratory data package? X Do the MQLs correspond to the concentration of the lowest non -zero calibration standard? X Are unadjusted MQLs included in the laboratory data package? X R10 OI Other problems /anomalies:. hPA �..-. _ Are all known problems /anomalies /special conditions noted in this LRC and ER? X Were all necessary corrective actions performed for the reported data? X Was applicable and available technology used to lower the SQL minimize the matrix interference affects on the sample results? X Rams wenuueu uy uie ieueI IN must oe incivaeo in the iaooratory data package suomitted in the I KHF required report(s). Items identified by the letter "S" should be retained and made available upon request for the appropriate retention period. O = organic analyses; [=inorganic analyses (and general chemistry, when applicable); NA = Not applicable; NR = Not reviewed; ER# = Exception Report identification number (an Exception Report should be completed for an item if "NR" or "No" is checked) Oxidor Laboratory Review Checklist Rev. 1.1, 072803 Page 2 of 4 OXIDOR Laboratory Review Checklist: Supporting Data Laboratory Name: OXIDOR Laboratories, LLC LRC Date: October 27, 2009 Project Name: 940.002.003 Coppell Auto Ctr. Laboratory Job Number: 0910331 W &M Environmental Group, Inc. Reviewer Name: Kyra Crutchfield JQC Batch Number(s): See Cross - reference List # A 2 Description Yes No NA NR ER# 1 01 Initial calibration (ICAL) Were response factors and /or relative response factors for each analyte within QC limits? X Were percent RSDs or correlation coefficient criteria met? X Was the number of standards recommended in the method used for all analytes? X Were all points generated between the lowest and highest standard used to calculate the curve? X Are ICAL data available for all instruments used? X Has the initial calibration curve been verified using an appropriate second source standard? X S2 OI Initial and continuing calibration verification (ICCV and CCV) and continuing calibration Was the CCV analyzed at the method required frequency? X Were percent differences for each analyte within the method - required QC limits? X Was the ICAL curve verified for each analyte? X Was the absolute value of the analyte concentration in the inorganic CCB < MDL? X S3 O Mass spectral tuning: Was the appropriate compound for the method used for tuning? X. Were ion abundance data within the method - required QC limits? X S4 O Internal Standards (IS): Were IS area counts and retention times within the method - required QC limits? X S5 OI Raw data (NELAC section 1 appendix A glossary, and section 5.12 or ISO /IEC 17205 section ?, Were the raw data (for example, chromatograms, spectral data) reviewed by an analyst? X Were data associated with manual integrations flagged on the raw data? X S6 OI Dual column confirmation tv . .; Did dual column confirmation results meet the method - required QC? X S7 01 Tentatively identified compounds (TICS): If TICs were requested, were the mass spectra and TIC data subject to appropriate checks? X S8 I Interference Check Sample (ICS) results: Were percent recoveries within the method QC limits? X '9 I Serial dilutions, post digestion spikes, and method of standard additions Were percent differences, recoveries, and the linearity within the QC limits specified in the method? X S10 OI Method detection limit (MDL) studies Was a MDL study performed for each reported analyte? X Is the MDL either adjusted or supported by the analysis of DCSs? X S11 01 Proficiency test reports: Was the laboratory's performance acceptable on the applicable proficiency tests or evaluation studies? X S12 OI Standards documentation Are all standards used in the analysis NIST - traceable or obtained from other appropriate sources? X S13 Of Compound / analyte identification procedures.: - Are the procedures for compound /analyte identification documented? X S14 OI Demonstration of analyst competency (DOC) Was DOC conducted consistent with NELAC Chapter 5C or ISO /IEC 4? X Is documentation of the analyst's competency up -to -date and on file? X S15 OI Verification /validation documentation for methods (NELAC Chap 5 or ISO /IEC 17025 Section 5) L Are all methods used to generate the data documented, verified, and validated, where applicable? X S16 OI Laboratory standard operating procedures (SOPs): Are laboratory SOPs current and on file for each method performed? X Items identified by the letter "R" must be included in the laboratory data package submitted in the TRRP- required report(s). Items identified by the letter "S" should be retained and made available upon request for the appropriate retention period. O = organic analyses; l= inorganic analyses (and general chemistry, when applicable); NA = Not applicable; NR = Not reviewed; ER# = Exception Report identification number (an Exception Report should be completed for an item if "NR" or "No" is checked). Oxidor Laboratory Review Checklist Rev. 1.1, 072803 Page 3 of 4 OXIDOR Laboratory Review Checklist: Exception Reports Laboratory Name: OXIDOR Laboratories, LLC LRC Date: October 27, 2009 Project Name: 940.002.003 Coppell Auto Ctr. Laboratory Job Number: 0910331 W &M Environmental Group, Inc. Reviewer Name: Kyra Crutchfield JQC Batch Number(s): See Cross - ref erence Li st ER #' DESCRIPTION ER #1 MSD recovery of TPH was slightly lower than Oxidor QC limits for QC batch 1005_02320AS. ER# = Exception Report identification number (an Exception Report should be completed for an item if "NR" or "No" is checked on the LRC) Oxidor Laboratory Review Checklist Rev. 1.1, 072803 Page 4 of 4 ACCO Q L�.� Order ID: 0910331 OXIDOR Laboratories, LLC ," � Date: 10i26i2009 Page 1 of 30 T104704227 -09 -TX Monday, October 26, 2009 W &M Environmental Group, Inc. Frank Clark 906 E. 18th, Suite 100 Plano, TX 75074 Tel: (214) 369 -2500 Fax: (972) 516 -4145 Re: Project Name: Coppell Auto Ctr. Project Number: 940.002.003 Project Location: W. Bethel Rd - Coppell Oxidor received 43 solid sample(s). The analysis performed were as follows: Sample Sample ID Matrix Collected Analysis 0910331 -006 SB 010 - 12 ft Solid 10/15/2009 08:20 BTEX/MTBE, Dry Weight, Total Petroleum Hydrocarbons 0910331 -011 SB 011 - 10 ft Solid 10/15/2009 08:50 BTEX/MTBE, Dry Weight, Total Petroleum Hydrocarbons 0910331 -014 SB 012 - 4 ft Solid 10/15/2009 09:30 Arsenic, Dry Weight, Lead 0910331 -015 SB 012 - 6 ft Solid 10/15/2009 09:30 Dry Weight, Total Petroleum Hydrocarbons 0910331 -017 SB 012 - 10 ft Solid 10/15/2009 09:30 Arsenic, Dry Weight, Lead 0910331 -020 SB 013 - 4 ft Solid 10/15/2009 10:05 Arsenic, Dry Weight, Lead 0910331 -023 SB 013 - 10 ft Solid 10/15/2009 10:05 Arsenic, Dry Weight, Lead 0910331 -029 MW 01 - 15 ft Solid 10/15/2009 10:45 BTEX/MTBE, Dry Weight, Total Petroleum Hydrocarbons 0910331 -031 MW 01 - 22 ft Solid 10/15/2009 10:45 BTEX/MTBE, Dry Weight, Total Petroleum Hydrocarbons 0910331 -036 MW 03 - 20 ft Solid 10/15/2009 13:05 STEX/MTBE, Dry Weight, Total Petroleum Hydrocarbons 0910331 -038 MW 04 -1 ft Solid 10/15/2009 14:15 BTEX/MTBE, Dry Weight, Total Petroleum Hydrocarbons 0910331 -042 MW 04 - 23 ft Solid 10/15/2009 14:15 BTEX/MTBE, Dry Weight 0910331 -043 MW 04 - 20 ft Solid 10/15/2009 14:15 BTEX/MTBE, Dry Weight Respectfully submitted, Charles Brungardt President C n www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ` h ACCp o +" OXIDOR Laboratories, LLG T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Coppell Auto Ctr. Customer Sample ID: SB 010 -12 ft Oxidor Sample ID: 0910331 -006 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 08:20 Parameter M QL SQL Result Units Date Analyzed Method Analyst General Chemistry % Solids 0.1 0.1 91.9 % 10/20/09 15:05 Dry Weight J.M. BTEX/MTBE Benzene 5 5.4 ND pg /kg 10/19/0918:47 8260B V.D.L. Toluene 5 5.4 ND pg /kg 10/19/0918:47 8260B V.D.L. Ethylbenzene 5 5.4 ND pg /kg 10/19/0918:47 8260B V.D.L. m,p- Xylene 10 10.9 ND pg /kg 10/19/0918:47 8260B V.D.L. o- Xylene 5 5.4 ND pg /kg 10/19/0918:47 8260B V.D.L. Xylenes (Total) 15 16.3 ND pg /kg 10/19/09 18:47 8260B V.D.L. MTBE 5 5.4 ND pg /kg 10/19/0918:47 8260B V.D.L. Surrogate Result Units Spike Conc Recovery Rec Limits 4- Bromofluorobenzene 43.7 pg /kg 50 pg /kg 87% 70- 130% Total Petroleum Hydrocarbons Prepared by method TX 1005 on 10119109 at 09:00 TPH (C 6 to C12) 25 27.2 ND mg /Kg 10/19/09 17:05 TX 1005 T.N. TPH (C12 to C28) 25 27.2 ND mg /Kg 10/19/09 17:05 TX 1005 T.N. TPH (C28 to C35) 25 27.2 ND mg /Kg 10/19/09 17:05 TX 1005 T.N. TPH (C6 to C35) 25 27.2 ND mg /Kg 10/19/09 17:05 TX 1005 T.N. Surrogate Result Units Spike Conc Recovery Rec Limits 1- chlorooctane 56.9 mg /Kg 50 mg /Kg 114% 70 -130% o- Terphenyl 56.6 mg /Kg 50 mg /Kg 113% 70 -130% Order ID: 0910331 Date: 10/26/2009 Page 2 of 30 Flags www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 }k GCOfi �= T Order ID: 0910331 OXIDOR L aboratories, LLC Date: 10/26/2009 Page 3 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Coppell Auto Ctr. Customer Sample ID: SB 011 - 10 ft Oxidor Sample ID: 0910331 -011 Sample Received: 10/16/2009 Parameter MQL SQL General Chemistry 80.1 % 10/20/09 15:05 % Solids 0.1 0.1 BTEX/MTBE 82608 V.D.L. Benzene 5 6.2 Toluene 5 6.2 Ethylbenzene 5 6.2 m,p- Xylene 10 12.5 o- Xylene 5 6.2 Xylenes (Total) 15 18.7 MTBE 5 6.2 arrogate 8260B V.D.L. 4- Bromofluorobenzene Spike Conc Recovery Total Petroleum Hydrocarbons 44.8 pg /kg 50 pg /kg Prepared by method TX 1005 on 10119109 at 09:00 ND mg /Kg TPH (C 6 to C12) 25 31.2 TPH (C12 to C28) 25 31.2 TPH (C28 to C35) 25 31.2 TPH (C6 to C35) 25 31.2 Surrogate 1- chlorooctane o- Terphenyl www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 Matrix: Solid Sample Collected: 10/15/2009 08:50 Result units Date Analyzed Method Analyst Flags 80.1 % 10/20/09 15:05 Dry Weight J.M. ND pg /kg 10/19/0919:11 82608 V.D.L. ND pg /kg 10/19/0919:11 8260B V.D.L. ND pg /kg 10/19/0919:11 82608 V.D.L. ND Ng /kg 10/19/0919:11 8260B V.D.L. ND pg /kg 10/19/0919:11 82608 V.D.L. ND pg /kg 10/19/0919:11 8260B V.D.L. ND pg /kg 10/19/0919:11 8260B V.D.L. Result Units Spike Conc Recovery Rec Limits 44.8 pg /kg 50 pg /kg 90% 70 -130% ND mg /Kg 10/19/09 17:51 TX 1005 T. N. ND mg /Kg 10/19/09 17:51 TX 1005 T. N. ND mg /Kg 10/19/09 17:51 TX 1005 T. N. ND mg /Kg 10/19/09 17:51 TX 1005 T. N. Result Units Spike Conc Recovery Rec Limits 49.0 mg /Kg 50 mg /Kg 98% 70 -130% 48.5 mg /Kg 50 mg /Kg 97% 70 -130% www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACCO "t r Order ID: 0910331 ` OXIDOR Laboratories LLC ■�"� _ Laboratories � � � Date: 10/26/2009 Page 4 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Cop pell A Ctr. Customer Sample ID: SB 012 - 4 ft Oxidor Sample ID: 0910331 -014 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 09:30 Parameter MQL SQL Result Units Date Analyzed Met Analyst Flags General Chemistry % Solids 0.1 0.1 86.9 % 10/20/09 15:05 Dry Weight J.M. Metals Digested by method 3050B on 10119109 at 11:00 Arsenic 0.5 0.575 2.42 mg /Kg 10/19/0914:57 6020 K.O. Lead 0.5 0.575 7.72 mg /Kg 10/19/09 14:57 6020 K.O. www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 , ACC \ �° 4, Order ID: 0910331 O XIDOR Laboratories, LLC Date: 10/26/2009 .. .. J Page 5 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Coppell Auto Ctr. Customer Sample ID: SB 012 - 6 ft Oxidor Sample ID: 0910331 -015 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 09:30 Parame MQL SQ Result Units Date Analyzed Meth Analyst Flags General Chemistry % Solids 0.1 0.1 88.1 % 10/20/09 15:05 Total Petroleum Hydrocarbons Prepared by method TX 1005 on 10119109 at 09:00 TPH (C 6 to C12) 25 28.4 ND mg /Kg 10/19/09 18:37 TPH (C12 to C28) 25 28.4 ND mg /Kg 10119/09 18:37 TPH (C28 to C35) 25 28.4 ND mg /Kg 10/19/09 18:37 TPH (C6 to C35) 25 28.4 ND mg /Kg 10/19/09 18:37 Surrogate 1- chlorooctane i- Terphenyl Result Units Spike Conc 56.9 mg /Kg 50 mg /Kg 56.2 mg /Kg 50 mg /Kg Dry Weight TX 1005 TX 1005 TX 1005 TX 1005 Recovery 114% 112% J.M. T.N. T. N. T. N. T. N. Rec Limits 70 -130% 70 -130% www.OXIDOR.com • 1825 E. Piano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 - 6422 • Fax: (972) 424 - 6508 Order ID: 0910331 _2 OXIDOR Labo ratories, LLC� c Date: 10/26/2009 Page 6 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Coppell Auto Ctr. Customer Sample ID: SB 012 - 10 ft Oxidor Sample ID: 0910331 -017 Sample Received: 10/16/2009 Parameter MQL SQL General Chemistry % Solids 0.1 0.1 Metals Digested by method 30508 on 10119/D9 at 11:00 Arsenic 0.5 0.564 Lead 0.5 0.564 San Result Units 88.6 % 20.8 mg /Kg 9.42 mg /Kg Matrix: Solid iple Collected: 10115/2009 Date Analyzed Me thod 10/20/09 15:05 Dry Weight 10/19/0917:12 6020 10/19/0917:12 6020 09:30 Analyst J.M. K.O. K.O. Flags www.OXIDOR.com • 1825 E. Piano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 j ACCp Order ID: 0910331 OXIDOR La bo r at ories, LLC N� x Date: 10/26/2009 Page 7 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Cop pell A uto Ctr. Customer Sample ID: SB 013 - 4 ft Oxldor Sample ID: 0910331 -020 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 10:05 Parameter MOIL SQL Result Units Date Analyzed Method Analys Flags General Chemistry % Solids 0.1 0.1 86.8 % 10/20/09 15:05 Dry Weight J.M. Metals Digested by method 30508 on 10119109 at 11:00 Arsenic 0.5 0.576 3.63 mg /Kg 10/19/09 17:18 6020 K. 0. Lead 0.5 0.576 23.2 mg /Kg 10/19/09 17:18 6020 K.O. www.OXIDOR.com • 1825 E. Plano Parkway #160 - Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 n c c a,y�� Order ID: 0910331 OXIDOR Laboratories, L L w� Date: 10/26 /2009 Page 8 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: C A uto Ctr. Customer Sample ID: SB 013 - 10 ft Oxidor Sample ID: 0910331 -023 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 10:05 Parameter M SQL Result Units Date Analyzed Metho Analyst Flags General Chemistry % Solids 0.1 0.1 90.8 % 10/20/09 15:05 Dry Weight J.M. Metals Digested by method 3050B on 10119109 at 11:00 Arsenic 0.5 0.551 7.21 mg /Kg 10/19/0917:24 6020 K.O. Lead 0.5 0.551 7.22 mg /Kg 10/19/09 17:24 6020 K.O. www.OXIDOR.corn • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 A _ y Order ID: 0910331 OXIDOR L a bo rat ories, LLC �° : � �� Date: 10/26/2009 s> Page 9 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Coppell Aut Ctr. Customer Sample ID: MW 01 - 15 ft Oxidor Sample ID: 0910331 -029 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 10:45 Parameter MQL SQL Result Units Date Analyzed Method An General Chemistry % Solids 0.1 0.1 85.7 % 10/20/09 15:05 Dry Weight J.M. BTEX/MTBE Benzene 5 5.8 ND Itg /kg 10/19/09 20:02 8260B V.D.L. Toluene 5 5.8 ND pg /kg 10/19/09 20:02 8260B V.D.L. Ethylbenzene 5 5.8 ND pg /kg 10/19/09 20:02 8260B V.D.L. m,p- Xylene 10 11.7 ND pg /kg 10/19/09 20:02 8260B V.D.L. o- Xylene 5 5.8 ND pg /kg 10/19/09 20:02 8260B V.D.L. Xylenes (Total) 15 17.5 ND pg /kg 10/19/09 20:02 8260B V.D.L. MTBE 5 5.8 ND pg /kg 10/19/09 20:02 8260B V.D.L. irrogate Result Units Spike Conc Recovery Rec Limits 4- Bromofluorobenzene 45.8 pg /kg 50 pg/kg 92% 70 -130% Total Petroleum Hydrocarbons Prepared by method TX 1005 on 10119109 at 09:00 TPH (C 6 to C12) 25 29.2 ND mg /Kg 10/19/09 19:24 TX 1005 T.N. TPH (C12 to C28) 25 29.2 ND mg /Kg 10/19/09 19:24 TX 1005 T.N. TPH (C28 to C35) 25 29.2 ND mg /Kg 10/19/09 19:24 TX 1005 T.N. TPH (C6 to C35) 25 29.2 ND mg /Kg 10/19/09 19:24 TX 1005 T.N. Surrogate Result Units Spike Conc Recovery Rec Limits 1- chlorooctane 47.1 mg /Kg 50 mg /Kg 94% 70 -130% o- Terphenyl 47.0 mg /Kg 50 mg /Kg 94% 70 -130% Flags www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 .,,,,,.... OXIDOR Laboratories, LLC c T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: C Auto Ctr. Customer Sample ID: MW 01 - 22 ft Oxidor Sample ID: 0910331 -031 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 10:45 Parameter MQL SQL Result Units Date Analyzed Method Analyst General Chemistry % Solids 0.1 0.1 86.3 % 10/20/09 15:05 Dry Weight J.M. BTEX/MTBE Benzene 5 5.8 ND pg /kg 10/19/09 22:33 8260B V.D.L. Toluene 5 5.8 ND pg /kg 10/19/09 22:33 82608 V.D.L. Ethylbenzene 5 116 3660 pg /kg 10/19/09 16:37 8260B V.D.L. m,p- Xylene 10 232 3180 pg /kg 10/19/0916:37 8260B V.D.L. o- Xylene 5 5.8 ND pg /kg 10/19/09 22:33 82608 V.D.L. Xylenes (Total) 15 17.4 3180 pg /kg 10/19/09 22:33 8260B V.D.L. MTBE 5 5.8 ND pg /kg 10/19/09 22:33 8260B V.D.L. Surrogate Result Units Spike Conc Recovery Rec Limits Date Analyzed: 10/19/09 22:33 Analyst: V.D.L. 4- Bromofluorobenzene 53.2 pg /kg 50 pg /kg 106% 70 -130% Date Analyzed: 10/19/09 16:37 Analyst: V.D.L. 4- Bromofluorobenzene 53.3 pg /kg 50 pg /kg 107% 70 -130% Total Petroleum Hydrocarbons Prepared by method 7X 1005 on 10119109 at 09:00 TPH (C 6 to C12) 25 29.0 895 mg /Kg 10/19/09 20:12 TX 1005 T.N. TPH (C12 to C28) 25 29.0 219 mg /Kg 10/19/09 20:12 TX 1005 T.N. TPH (C28 to C35) 25 29.0 ND mg /Kg 10/19/09 20:12 TX 1005 T.N. TPH (C6 to C35) 25 29.0 1114 mg /Kg 10/19/09 20:12 TX 1005 T.N. Surrogate Result Units Spike Conc Recovery Rec Limits 1- chlorooctane 57.5 mg /Kg 50 mg /Kg 115% 70 -130% o- Terphenyl 38.8 mg /Kg 50 mg /Kg 78% 70 -130% Order ID: 0910331 Date: 10/26/2009 Page 10 of 30 Flags www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACCp Order ID: 0910331 .,. ,....,. OXIDOR Laboratories, LLC ,N F � � Date: 10/26/2009 Page 11 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Name: Coppell Au Ctr. V.D.L. Customer Sample ID: MW 03 - 20 ft Oxidor Sample ID: 0910331 -036 Sample Received: 10/16/2009 Parameter MQL SQL General Chemistry 29.7 Surrogate % Solids 0.1 0.1 BTEX/MTBE V.D.L. D -1 Benzene 5 119 Toluene 5 119 Ethylbenzene 5 1190 m,p- Xylene 10 2370 o- Xylene 5 119 Xylenes (Total) 15 3560 MTBE 5 119 urogate 4- Bromofluorobenzene 4- Bromofluorobenzene V.D.L. Total Petroleum Hydrocarbons 8260B Prepared by method TX 1005 on 10119109 at 09:00 D -1 TPH (C 6 to C12) 25 29.7 TPH (C12 to C28) 25 29.7 TPH (C28 to C35) 25 29.7 TPH (C6 to C35) 25 29.7 Surrogate 8260B 1- chlorooctane D -1 o- Terphenyl V.D.L. Matrix: Solid Sample Collected: 10/15/2009 13:05 Result Units Date Analyzed Method Analyst Flags 84.3 % 823 pg /kg ND pg /kg 14600 pg /kg 25900 pg /kg 406 pg /kg 26306 pg /kg ND pg /kg Result Units Date Analyzed: 58.7 pg /kg Date Analyzed: 45.9 pg /kg 249 mg /Kg 118 mg /Kg ND mg /Kg 367 mg /Kg Result Units 64.5 mg /Kg 56.7 mg /Kg 10/20/09 15:05 Dry Weight J.M. 10/19/09 17:31 10/19/09 17:31 10/19/09 17:02 10/19/09 17:02 10/19/09 17:31 10/19/09 17:31 10/19/09 17:31 Spike Conc 10/19109 17:31 50 pg /kg 10/19/09 17:02 50 pg /kg 10/19/09 20:59 10/19/09 20:59 10/19/09 20:59 10/19/09 20:59 Spike Conc 50 mg /Kg 50 mg /Kg 8260B V.D.L. D -1 8260B V.D.L. D -1 82608 V.D.L. D -1 8260B V.D.L. D -1 8260B V.D.L. D -1 8260B V.D.L. D -1 8260B V.D.L. D -1 Recovery Rec Limits Analyst: V.D.L. 117% 70 -130% Analyst: V.D.L. 92% 70 -130% TX 1005 TX 1005 TX 1005 TX 1005 Recovery 129% 113% T. N. T. N. T. N. T. N. Rec Limits 70 -130% 70 -130% www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 � acco 1 ;o s Order ID: 0910331 OXIDOR L a bo r atories, LLC ;w° 4< �{ Date: 10/26/2009 x Page 12 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Proje Name: Coppell Auto Ctr. Customer Sample ID: MW 04 - 1 ft Oxidor Sample ID: 0910331 -038 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 14:15 Parameter MQL SQL Result Units Date Analyzed Method Analyst Flags General Chemistry % Solids BTEX/MTBE Benzene Toluene Ethylbenzene m,p- Xylene o- Xylene Xylenes (Total) MTBE 0.1 0.1 86.1 % 10/20/09 15:05 Dry Weight J. M. 5 5 5 10 5 15 5 Surrogate 4- Bromofluorobenzene Total Petroleum Hydrocarbons Prepared by method TX 1005 on 10/19/09 at 09:00 TPH (C 6 to C12) 25 TPH (C12 to C28) 25 TPH (C28 to C35) 25 TPH (C6 to C35) 25 Surrogate 1- chlorooctane o- Terphenyl 5.8 ND pg /kg 10/19/09 20:27 8260B V.D.L. 5.8 ND pg /kg 10/19/09 20:27 8260B V.D.L. 5.8 ND pg /kg 10/19/09 20:27 8260B V.D.L. 11.6 ND pg /kg 10/19/09 20:27 8260B V.D.L. 5.8 ND pg /kg 10/19/09 20:27 8260B V.D.L. 17.4 ND pg /kg 10/19/09 20:27 8260B V.D.L. 5.8 ND pg /kg 10/19/09 20:27 8260B V.D.L. Result Units Spike Conc Recovery Rec Limits 46.1 pg /kg 50 pg /kg 92% 70- 130% 29.0 ND mg /Kg 10/19/09 21:47 TX 1005 T. N. 29.0 ND mg /Kg 10/19/09 21:47 TX 1005 T. N. 29.0 ND mg /Kg 10/19/09 21:47 TX 1005 T. N. 29.0 ND mg /Kg 10/19/09 21:47 TX 1005 T. N. Result Units Spike Conc Recovery Rec Limits 54.3 mg /Kg 50 mg /Kg 109% 70 -130% 53.8 mg /Kg 50 mg /Kg 108% 70 -130% m • 1825 E. Plano Parkway #160 • Piano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 � �y ACCOy OXIDOR Laboratories, LLC T777 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project Nam Coppell Auto Ctr. Customer Sample ID: MW 04 - 23 ft Oxidor Sample ID: 0910331 -042 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10/15/2009 14:15 Parameter MQL SQL Result Units Date Analyzed M ethod Ana General Chemistry % Solids 0.1 0.1 83.1 % 10/20/09 15:05 Dry Weight J.M. BTEX/MTBE Benzene 5 6.0 ND pg /kg 10/20/0915:12 82608 V.D.L. Toluene 5 6.0 ND pg /kg 10/20/0915:12 8260B V.D.L. Ethylbenzene 5 6.0 ND pg /kg 10/20/0915:12 8260B V.D.L. m,p- Xylene 10 12.0 ND pg /kg 10/20/0915:12 8260B V.D.L. o- Xylene 5 6.0 ND pg /kg 10/20/0915:12 8260B V.D.L. Xylenes (Total) 15 18.1 ND pg /kg 10/20/09 15:12 82608 V.D.L. MTBE 5 6.0 ND pg /kg 10/20/0915:12 8260B V.D.L. arrogate Result Units Spike Conc Recovery Rec Limits 4- Bromofluorobenzene 45.3 pg /kg 50 pg /kg 91% 70 -130% Order ID: 0910331 Date: 10/26/2009 Page 13 of 30 Flags www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ! AGCp ^' T :. Order ID: 0910331 XIDOR Laboratories, LLC ; � Date: 10/26/2009 Page 14 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Analytical Report Project N Coppell Auto Ctr. Customer Sample ID: MW 04 - 20 ft Oxidor Sample ID: 0910331 -043 Matrix: Solid Sample Received: 10/16/2009 Sample Collected: 10115/2009 14:15 Parameter MQL SQL Result Units Date Analyzed Method Analyst General Chemistry % Solids 0.1 0.1 84.2 % 10/20/09 15:05 Dry Weight J.M. BTEX/MTBE Benzene 5 5.9 NO pg /kg 10/19/09 20:52 8260B V.D.L. Toluene 5 5.9 NO pg /kg 10/19/09 20:52 8260B V.D.L. Ethylbenzene 5 5.9 NO pg /kg 10/19/09 20:52 8260B V.D.L. m,p- Xylene 10 11.9 NO pg /kg 10/19/09 20:52 82608 V.D.L. o- Xylene 5 5.9 NO pg /kg 10/19/09 20:52 8260B V.D.L. Xylenes (Total) 15 17.8 NO pg /kg 10/19/09 20:52 8260B V.D.L. MTBE 5 5.9 NO pg /kg 10/19/09 20:52 8260B V.D.L. Surrogate Result Units Spike Conc Recovery Rec Limits 4- Bromofluo robe nzene 45.1 pg /kg 50 pg /kg 90% 70 -130% Flags www.OXIDOR.com • 1825 E. Plano Parkway #160 • Piano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 y AC C Order ID: 0910331 OXIDOR L a bor at ories, LLC Q Date: 10/26/2009 �� q Page 15 of 30 7104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Cross Reference Project Nam e: Coppell Auto Ctr. Customer ID: Lab ID: Test Method QCBatchlD: SB 010 - 12 ft 0910331 -006 Total Petroleum Hydrocarbons TX 1005 1005_02320AS BTEX /MTBE 8260B BTXM_04809_S Dry W eight Dry Weight DW 01219 S SB 011 - 10 ft 0910331 -011 Total Petroleum Hydrocarbons TX 1005 1005 02320AS BTEX/MTBE 82608 BTXM_04809_S Dry Weight _ Dry Weight DW 01219 S SB 012 - 4 ft 0910331 -014 Dry Weight Dry Weight DW_01219_S Arsenic 6020 META_11326_S Lead 6 020 META 11326S SB 012 - 6 ft 0910331 -015 Total Petroleum Hydrocarbons TX 1005 1005_02320AS Dry Weight Dry Weight DW_01219_S SB 12 - 10 ft 0910331 -017 Dry Weight Dry Weight DW 01219S Arsenic 6020 — META 11326_S Lead - 602 META 1326 S 3 013 - 4 ft 0910331 -020 Dry Weight Dry Weight --- - W D_01215S Lead 6020 META_11326_S Arsenic 6020 META 11326 S SB 013 - 10 ft 0910331 -023 Dry Weight Dry Weight DW_01219_S Arsenic 6020 META_11326_S Lead 6020 META 1326 S MW 01 - 15 ft 0910331 -029 Total Petroleum Hydrocarbons TX 1005 1005_02320AS BTEX /MTBE 8260B BTXM_04809 S Dry Weight Dry Weight DW_01219 S MW 01 - 22 ft 0910331 -031 Total Petroleum Hydrocarbons TX 1005 1005_02320AS BTEX/MTBE 8260B BTXM_04809_S Dry Weight Dry Weight W D_01219 MW 03 - 20 ft 0910331 -036 Total Petroleum Hydrocarbons TX 1005 - S 1005 02320AS BTEX/MTBE 82608 BTXM_04809_S Dry Weight Dry Weight DW_01219_S MW 04 - 1 ft 0910331 -038 Total Petroleum Hydrocarbons TX 1005 1005_02320AS BTEX /MTBE 8260B BTXM_04809_S Dry Weight Dry Weight DW 01219 S 0910331 -042 Dry Weight Dry Weight - - -- - DW_01219_S BTEX /MTBE 82606 VOC 30 709 S MW 4 - 20 ft 0910331 -043 BTEX /MTBE 82608 BTXM_04809_S Dry Weight Dry Weight DW_01219 S www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ' OXIDOR Laboratories, LLC ACC � AC o ��'�,. Aso Order ID: 0910331 Date: 10/26/2009 Page 16 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark QC Summary Project Name: Coppell Auto Ctr. Reference Rec RPD QC Type Parameter Result Value Spike Conc Rec Limits RPD Limits Flags QCBatchlD DW_01219_S Replicate % Solids 87.0% 87.4% 0.4% 0 -20% QCBatchlD META S Blank Arsenic ND mg /Kg - - Lea ND mg /Kg LCS Arsenic 1.03 mg /L 1 mg /L 103% 85 -115% Lead 1 0.6 mg /L 11 mg /L 96 85 -115% LCSD Arsenic 1.02 mg /L 1 mg /L 102% 85- 115 %_ -- 0.9% 0 -20% Lead 10.5 mg /L 11 mg /L 96% 85 -115% 0.9% 0 -20% MS Arsenic 50.3 mg /Kg 2.1 mg /Kg 50 mg /Kg 96% 80 -120% Lead - -- -- -- -- - - 529 mg /Kg - -- - - - - 6.71 mg /Kg 550 mg /Kg 95% 80 -120% MSD Arsenic - 53.0 mg /Kg 2.1 mg /Kg 50 mg /Kg 102% 80- 120% _ 5.1% 0 -20% Lead 530 mg /Kg 6.71 mg /Kg 550 mg /Kg 95% 80- 120% 0.2% 0 -20% QCBat 1005 02320AS Blank TPH (C 6 to C12) ND mg /Kg TPH (C12 to C28) ND mg /Kg TPH (C28 to C35) ND mg /Kg TPH (C6 to C35) ND mg /Kg Surrogate Result Spike Conc Recovery Rec Limits 1- chlorooctane 54.2 mg /Kg 50 mg /Kg 108% 70 -130% o- Terphenyl 52.2 mg /Kg 50 mg /Kg 104% 70- 130% LCS TPH (C6 to C35) 92.4 mg /Kg 100 mg /Kg 92% 75- 125% - - -- Surrogate Result Spike Conc Recovery Rec Limits 1- chlorooctane 55.0 mg /Kg 50 mg /Kg 110% 70- 130% o- Te rph en yl 53.2 mg /Kg 50 mg /Kg 106% 70- 130% LCSD TPH (C6 to C35) 82.9 mg /Kg 100 mg /Kg 83% 75- 125% 10.8% 0 -20% Surrogate Result Spike Conc Recovery Rec Limits 1- chlorooctane 49.2 mg /Kg 50 mg /Kg 98% 70- 130% o- Terphenyl 47.4 mg /Kg 50 mg /Kg 95% 70 -130% MS H (C6 to C35) 75.3 mg /Kg ND 100 mg /Kg 75% - 7 - 5 -- -l - 25% - - - - Surrogate Result Spike Conc Recovery Rec Limits 1- chlorooctane 52.4 mg /Kg 50 mg /Kg 105% 70- 130% o- Terphenyl 50.5 m /Kg 50 mg /Kg 101% 70 -130% MSD TPH (C6 to C35) 70.1 mg /Kg ND 100 mg /Kg 70% 75- 125% -- - - - - 7.2% 0 -20% - - Q -7 Surrogate Result Spike Conc Recovery Rec Limits 1- chlorooctane 53.9 mg /Kg 50 mg /Kg 108% 70- 130% o- Terphenyl 52.8 mg /Kg 50 mg /Kg 106% 70- 130% QCBatchlD BTXM 04809 S Blank MTBE ND N9 /kg Benzene ND pg /kg Toluene ND pg /kg Ethylbenzene ND pg /kg www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 C � 0 , Order ID: 0910331 OXIDOR Laboratories, L LC r Date: 10/26/2009 q Page 17 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark QC Summary Project N ame: Coppell Auto Ctr. Reference Rec RPD QC Type Parameter Result Value Spike Conc Rec Limits RPD Limits Flags QCBat chlD BTXM 04809 S m,p- Xylene ND pg /kg o- Xylene ND pg /kg Xvlanae /Tntnil Ain ,,..i... Qurrugme Keswt Spike Corn 4 -Brom ofl uo robe nzen e 47.5 pg /kg 50 pg /kg LCS MTBE 45.8 pg /kg 50 pg /kg Benzene 47.6 pg /kg 50 pg/kg Toluene 48.2 pg /kg 50 pg /kg Ethylbenzene 49.7 pg /kg 50 pg /kg m,p- Xylene 95.8 pg /kg 100 pg /kg o- Xylene 48.3 pg /kg 50 pg/kg Surrogate Result Spike Conc 4- Bromofluorobenzene 49.0 pg /kg 50 pg /kg LCSD MTBE 46.8 pg /kg 2.3% 50 pg/kg Benzene 47.6 pg /kg 0.1% 50 pg /kg Toluene 49.0 pg /kg 1.6% 50 pg /kg Ethylbenzene 50.2 pg /kg 1.0% 50 pg /kg m,p- Xylene 96.2 pg /kg 0.4% 100 pg /kg o- Xylene 48.0 pg /kg 0.6% 50 pg /kg Surrogate Result Spike Conc 4- Bromofluo robe nzene 49.6 pg /kg 50 pg /kg MS MTBE 49.0 pg /kg 4.04 pg /kg 50 pg /kg Benzene 51.2 pg /kg ND 50 pg /kg Toluene 50.9 pg /kg ND 50 pg /kg Ethylbenzene 51.7 pg /kg ND 50 pg /kg m,p- Xylene 100 pg /kg ND 100 pg /kg o- Xylene 50.4 pg /kg ND 50 pg /kg Surrogate Result Spike Conc 4- Bromofluorobenzene 48.6 p /kg 50 pg/kg MSD MTBE 47.7 pg /kg 4.04 pg /kg 50 pg /kg Benzene 49.6 pg /kg ND 50 pg /kg Toluene 49.1 pg /kg ND 50 pg /kg Ethylbenzene 52.0 pg /kg ND 50 pg /kg m,p- Xylene 99.4 pg /kg ND 100 pg /kg o- Xylene 50.3 pg /kg ND 50 pg /kg Surrogate Result Spike Conc 4- Bromofluorobenzene 49.8 pg /kg 50 pg /kg Q CBat c hlD VO C 30709 S lank MTBE - - - ND pg /kg Benzene ND pg /kg Toluene ND pg /kg Ethylbenzene ND pg /kg Recovery Rec Limits 95% 70- 1 92% 70- 130% -- 95% 70- 130% 96% 70- 130% 99% 70- 130% 96% 70- 130% 97% 70- 130% Recovery Rec Limits 98% 70 -130% 94% 70- 130% 2.3% 0 -25% 95% 70- 130% 0.1% 0 -25% 98% 70- 130% 1.6% 0 -25% 100% 70- 130% 1.0% 0 -25% 96% 70- 130% 0.4% 0 -25% 96% 70- 130% 0.6% 0 -25% Recovery Rec Limits 99 % 70- 130% 90% 70- 130% 102% 70- 130% 102% 70- 130% 103% 70- 130% 100% 70- 130% 101% 70 -130% Recovery Rec Limits 97% 70- 130% 87% 70- 130% 2.7% 0 -25% - 99% 70- 130% 3.2% 0 -25% 98% 70- 130% 3.6% 0 -25% 104% 70- 130% 0.6% 0 -25% 99% 70- 130% 0.6% 0 -25% 101% 70 -130% 0.2% 0 -25% Recovery Rec Limits 100% 70 -130% www.OXIDOR.com • 1825 E. Piano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 Order ID: 0910331 .' .r OXIDOR Laboratories, LLC Date: 10/26/2009 Page 18 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark QC Summary Project Name: Coppell Auto Ct Reference Rec RPD QC Type Parameter Result Value Spike Conc Rec Limits RPD Limits Flags QCBatchlD VO m,p- y ene ND pg /kg o- Xylene ND pg /kg Xylenes (Total) ND pg /kg Surrogate Result Spike Conc Recovery Rec Limits 4- Bro mofluorobenzene 45.0 pg /kg 50 pg /kg 90% 70 -130% LCS 47.4 pg /kg 50 pg /kg 95% - 70-130% - - - - - -- Benzene 50.8 pg /kg 50 pg /kg 102% 70 -130% Toluene 50.7 pg /kg 50 pg /kg 101% 70 -130% Ethylbenzene 50.4 pg /kg 50 pg /kg 101% 70 -130% m,p- Xylene 99.9 pg /kg 100 pg /kg 100% 70 -130% o- Xylene 50.5 pg /kg 50 pg /kg 101% 70 -130% Surrogate Result Spike Conc Recovery Rec Limits 4- Bromofluorobenzene 49.3 pg /kg 50 pg /kg 99% 70 -130% L SD MTBE 48.9 pg/kg 50 pg /kg 98% 70 -130% 3.1% - 0 -25% - Benzene 51.7 pg /kg 50 pg /kg 103% 70 -130% 1.8% 0 -25% Toluene 51.0 pg /kg 50 pg /kg 102% 70- 130% 0.6% 0 -25% Ethylbenzene 52.8 pg /kg 50 pg/kg 106% 70 -130% 4.7% 0 -25% m,p- Xylene 104 pg /kg 100 pg /kg 104% 70 -130% 4.0% 0 -25% o- Xylene 52.9 pg /kg 50 pg /kg 106% 70 -130% 4.6% 0 -25% Surrogate Result Spike Conc Recovery Rec Limits 4- Bromofluorobenzene 49.6 p /kg 50 pg /kg 99 % 70- 13 MS MTBE 63.4 pg /kg ND 50 pg/kg 127% 70- 130% - -- _- _ Benzene 53.3 pg /kg ND 50 pg /kg 107% 70- 130% Toluene 52.2 pg /kg ND 50 pg /kg 104% 70 -130% Ethylbenzene 54.7 pg /kg ND 50 pg /kg 109% 70- 130% m,p- Xylene 108 pg /kg ND 100 pg /kg 108% 70 -130% o- Xylene 54.8 pg /kg ND 50 pg/kg 110% 70- 130% Surrogate Result Spike Conc Recovery Rec Limits 4 Bro mofluorobenzene 52.2 p g /kg 50 pg /kg 104% 70- 130% M D MTBE 61.6 pg /kg NO 50 pg /kg 123% - - - - - - -- 70- 130% - - 2.9% - 0 -25% Benzene 52.3 pg /kg ND 50 pg /kg 105% 70- 130% 1.9% 0 -25% Toluene 52.1 pg /kg ND 50 pg /kg 104% 70- 130% 0.2% 0 -25% Ethylbenzene 53.8 pg /kg ND 50 pg/kg 108% 70 -130% 1.7% 0 -25% rn,p- Xylene 106 pg /kg ND 100 pg /kg 106% 70- 130% 1.9% 0 -25% o- Xylene 54.3 pg /kg ND 50 pg/kg 109% 70- 130% 0.9% 0 -25% Surrogate Result Spike Conc Recovery Rec Limits 4- Bromofluorobenzene 52.6 pg /kg 50 pg/kg 105% 70 -130% www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plana, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 g yt4 ACCol,, 1 �-r Order ID: 0910331 ®XIDOR L a bo r atories, LLC 40 Date: 10/26/2009 ti Page 19 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Case Narrative Project Name: Coppell Auto Ctr. Elevated reporting limit(s) due to dilution. Dilution resulted from sample matrix interference, high target analyte(s), high non - target analyte(s) or a combination thereof. Q -7 Recovery and /or RPD outside desirable limits. ppm Parts per million = mg /Kg or mg /L ppb Parts per billion = ug /Kg or ug /L MQL Method quantitation limit SDL Sample detection limit (reflects any laboratory adjustments made to the sample during analysis such as dry weight or dilutions) SQL Sample quantitation limit (reflects any laboratory adjustments made to the sample during analysis such as dry weight or dilution ND Analyte not detected at or above SQL LCS /LCSD Laboratory control spike / Laboratory control spike duplicate MS /MSD Matrix spike / Matrix spike duplicate PD Relative percent difference Sub Analysis performed by subcontract laboratory Solid sample results reported on a dry weight basis for all applicable analysis, unless otherwise noted. Dry weight calculations based upon % solids obtained as outlined in EPA method 5035 section 7.5 This report is intended only for the use of W &M Environmental Group, Inc. and may contain information that is privileged and confidential. It may not be reproduced in full (or in part) without the expressed written permission of W &M Environmental Group, Inc. and Oxidor Laboratories, LLC. Oxidor Laboratories, LLC certifies to the best of its knowledge that all results contained in this report are consistent with the National Environmental Laboratory Accreditation Program, except where otherwise noted. www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACCp w �1�'1' Order ID: 0910331 OXIDOR Laboratories, LLC Date: 10/26/2009 Page 20 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project Name: Coppell Auto Ctr. Receipt temp: 4.3 °C on Ice All applicable VOA's received free of headspace: N/A Receipt method: Client Custody seal intact: Not Present A ll sample / labels r eceived intact: Yes Customer Sample ID: SIB 010 - 2 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -001 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:20 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SIB 010 - 4 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -002 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:20 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 010 - 6 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -003 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:20 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SIB 010 - 8 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -004 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:20 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 010 - 10 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -005 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:20 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp www.OXIDOR.com - 1825 E. Plano Parkway #160 • Plano, TX 75074 - Tel: (972) 424 -6422 - Fax: (972) 424 -6508 K ACCp ("''��r L� T d " , �r y � Order ID: 0910331 ti. XIDOR Laboratories, LL � � "� Date: 10/26/2009 Page 21 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project Name Cop Auto Ctr. Customer Sample ID: SB 010 -12 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -006 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:20 Matrix: Solid Indicated Bottle Tvpe Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 011 - 2 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -007 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:50 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: SB 011 - 4 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -008 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:50 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 011 - 6 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -009 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:50 Matrix: Solid Bottle Type Count Collection Method Indicated Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 011 - 8 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -010 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:50 Matrix: Solid Bottle Type Count Collection Method Indicated Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp - C ustomer Sample ID: SB 011 - 10 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -011 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:50 Matrix: Solid Bottle Type Count Collection Method Indicated Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp www.OXIDOR.com • 1825 E. Plano Parkway #160 - Piano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACC09 Order ID: 0910331 Wo :� OXIDOR Labo ratories LLC Date: 10/26/2009 7 7 " Page 22 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project Name: Coppell Auto Ctr. Customer Sample ID: SB 011 -12 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -012 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 08:50 Matrix: Solid Bottle Tvge Count 4 oz Glass Jar 2 Customer Sample ID: SB 012 - 2 ft Oxidor Sample ID: 0910331 -013 Collected: 10/15/09 09:30 Bottle Type Count 4 oz Glass Jar 2 Customer Sample ID: SB 012 - 4 ft Oxidor Sample ID: 0910331 -014 Collected: 10/15/09 09:30 Bottle Type Count 4 oz Glass Jar 2 Customer Sample ID: SB 012 - 6 ft Oxidor Sample ID: 0910331 -015 Collected: 10/15/09 09:30 Indicated Collection Method Parts / Interval Preservation pH Grab Temp - Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid Indicated Collection Method Parts / Interval Preservation pH Grab Temp Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid Indicated Collection Method Parts / Interval Preservation pH Grab Temp Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 012 - 8 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -016 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 09:30 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation gH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 012 -10 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -017 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 09:30 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation r)H 4 oz Glass Jar 2 Grab Temp www.OXIDOR.com • 1825 E. Plano Parkway #160 - Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 > � , OXIDOR Laboratories, LL1. ACC '; i o ��. �`� �� � �' �° Order ID: 0910331 Date: 10/26/2009 Customer Sample ID: SB 012 -12 ft Page 23 of 30 Collected By: T104704227 -09 -TX Oxidor Sample ID: 0910331 -018 W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project Na Coppell A Ctr. Customer Sample ID: SB 012 -12 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -018 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 09:30 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation [H 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 013 - 2 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -019 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 013 - 4 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -020 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: SB 013 - 6 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -021 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:05 Matrix: Solid Bottle Type Count 4 oz Glass Jar 2 Customer Sample ID: SB 013 - 8 ft Oxidor Sample ID: 0910331 -022 Collected: 10/15/09 10:05 Bottle Type Count 4 oz Glass Jar 2 Customer Sample ID: SB 013 10 ft Oxidor Sample ID: 0910331 -023 Collected: 10/15/09 10:05 Bottle Type Count 4 oz Glass Jar 2 Indicated Collection Method Parts / Interval Preservation pH Grab Temp Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid Indicated Collection Method Parts / Interval Preservation pH Grab Temp - Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid Indicated Collection Method Parts / Interval Preservation pH Grab Temp www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 i ACC0 .9, Order ID: 0910331 ... OXID 7R .L Laboratories, LLC � ��� `� Date: 10/26/2009 g z Page 24 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project N Coppell Auto Ctr. Customer Sample ID. SB 013 -12 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -024 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 01 -1 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -025 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 01 - 5 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -026 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 01 -10 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -027 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Tvpe Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 01 -13 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -028 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 01 -15 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -029 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp - www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 � Order ID: 0910331 � ..�....��. aXIDOR Labor atories, LLC w � `� Date: 10/26/2009 Page 25 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Proje Na Cop A uto Ctr. C ustomer Sample ID: MW 01 - 20 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -030 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 01 - 22 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -031 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 10:45 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 03 -1 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -032 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 13:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 03 - 5 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -033 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 13:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 03 -10 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -034 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 13:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation P. 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 03 - 15 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -035 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 13:05 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp - www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACCp A wr Order ID: 0910331 " OXIDOR Laboratories, LLB ,�° ��� ` � `� Date: 10r26/2009 Page 26 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project Name: Coppell Auto Ctr. Customer Sample ID: MW 03 - 20 ft Oxidor Sample ID: 0910331 -036 Collected: 10/15/09 13:05 Bottle Type Count Collection Method 4 oz Glass Jar 2 Grab Customer Sample ID: MW 03 - 22 ft Oxidor Sample ID: 0910331 -037 Collected: 10/15/09 13:05 Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid Parts / Interval Indicated Parts / Interval Preservation pH Temp Collected By: Brent Vollman Collector Affiliation: W &M Environmental Group, Inc. Matrix: Solid www.OXIDOR.com • 1825 E. Plano Parkway #160 - Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 04 -1 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -038 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 14:15 Matrix: Solid Indicated Bottle Tvpe Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 04 - 5 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -039 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15109 14:15 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 04 -10 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -040 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10115/09 14:15 Matrix: Solid Indicated Bottle Tvpe Count Collection Method Parts / Interval Preservation PH 4 oz Glass Jar 2 Grab Temp Customer Sample ID: MW 04 - 15 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -041 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 14:15 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp www.OXIDOR.com • 1825 E. Plano Parkway #160 - Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACCO Order ID: 0910331 OXIDOR Laboratories ' LLG w `_ a � Date: 10/26/2009 F. U Page 27 of 30 T104704227 -09 -TX W &M Environmental Group, Inc. Frank Clark Sample Preservation Verification Project Name: Coppe A Ctr. Customer Sample ID: MW 04 - 23 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -042 Collector Affiliation: W &M Environmental Group, Inc. Collected: 10/15/09 14:15 Matrix: Solid Indicated Bottle Tvpe Count Collection Method Parts / Interval Preservation sH 4 oz Glass Jar 2 Grab Temp - Customer Sample ID: MW 04 - 20 ft Collected By: Brent Vollman Oxidor Sample ID: 0910331 -043 Collector Affiliation: W &M Environmental Group, Inc. Collected. 10/15/09 14:15 Matrix: Solid Indicated Bottle Type Count Collection Method Parts / Interval Preservation pH 4 oz Glass Jar 2 Grab Temp - Sample conditions at time of receipt at laboratory verified in part or in whole by: T. M. www.OXIDOR.com • 1825 E. Plano Parkway #160 • Plano, TX 75074 • Tel: (972) 424 -6422 • Fax: (972) 424 -6508 ACC ' Order ID: 0910331 OXIDOR Laboratories, LLC ; `° ` � � Date: 10/26/2009 Page 28 of 30 T104704227 -09 -TX Chain of Custody PROJECT DESCRIPTION: Coppell Auto Ctr. OXIPOK Llboraloijes, LLC Chain of Custody Record 1825 East Plann Parkway ri160 Plano, TX 75074.857D 4 � tr ''" F '' r Page I Of 3 P 9T2 424 6422 F. 972 424 f508 custornersetvk:e @oxklof com Sand Rapod To Pro)ec1 I Raporl Information Comparry Noms 1,' Q �t - -..� 1 •V' +' `� Crcle Requested Tu (Less than 2 Days must be verified with lab) 7- Days ress Add 904 E - 18'11L 1- r�4e(: In 4� Day 2 Days ASAP Prof Name Z+ _ 1 P C it l[M.T' CCITT' �5 R /USH� } -D ' CRY Pl r..a+c P Stale - Zip -,SD 7N Project L-1—l- C +� � 1k R l.i Gtl ) TX 4 W. CI ws1L1 � Cordael N— 1TWK 1. ` Project a PO N 94t6,0(7;-W3 Contact Email �cta�.vL. rn.urw. Semple, Name Sampler Company 'JrL'4�,+ Vcl(►rwr WF.N1 E- . vin.a Phone `, -7 ..�cl,� Fes &I- L) Sampler Signature Sand lrivoloa To (Only Y Dllfererd from above Melm Codes Spacullmilruclions - Compi N.— L - Lpuld S - Solid Address Presevetbn W - WS A - Air Codes City 1 - Stale Zip 2 -NOre 4.HCI - HNO,, 5-N. 'Please confirm condit -1 re nests rior to addh onal anal an Requested eq '7 111 5 C.M.0 Name 7 -H,So, 6 -Ica - other Phone Container Fax P. 0 Codes Plastic G - Glean - Other `e - a OXIDOR Order ID Customer Sample ID Sample Info 1 6 .n 9 m E € 09 1833I Date rre s 9 S E A a $ u -oo) 1 55 01 2 -Pr lobfio4 $!'G'..() S 6 G G X -o °z . . . 2 _ _ - Sg 0t0 1ft- 10 0 0o1 S 2 6 X f - ao 3 5f3 01D - b-E /0'44'v 5 2 6 X ✓ $13 oho_— W 10f(S?W 5 - 2 b D'S 513 oa o- I P 4 /o� 0? 5 2 6 - "°° sa DID 'ONE' s 2 G -ooh 7 Sp J -Doss a ' 5$ . vn — i f+ ° g S$ of( - 6 F(- - °frJ 58 S Olt 11 Sg oil— 104 XX - 047— 12 .... Cb _. 011 — ('Z f- 17 14 / 15 RaX nsd Aaiiarbn Date Ting Received to Aft.— Date Time x �yc�r+f i N t,n ! 0 v.. ►7. 9 S x RaMnpualud IW AM.— Date Time Receied br Affibton Del. Recalv 7 e x x Ralnpehatl ARiiMpn ONa ime ad X r OR b T�rw i7 by T 35 Submilal of samples signifm acceptance of OXIDOR'n St rd Terms and Conditions rzzr Doe • Nev s a UAIDOR camwl accept ventral changes to IhR document. Please faa p email wratan moci ncanoas Temp al Rr pl `f • -) "C mIc 48 www.OXIDOR.com e 1825 E. Plano Parkway #160 • Plano, TX 75074 e Tel: (972) 424 -6422 e Fax: (972) 424 -6508 ACCO . ;, Order ID: 0910331 i ®XIDOR Lab oratories, LLC k� Date: 10/26/2009 s Page 29 of 30 T104704227 -09 -TX Chain of Custody PROJEC DESCRIPTION: Coppell Auto Ctr. OXIDOR Laboralolir LLB: Chain of Custody Record 1525 least Plana Pafkvjay. #160 Plano 75074 -8570 �' s ';. Page Z. of . Pu. 4 rime P. 972 424.6505 eP i cus torner 42 toryterseNjme@ox com A Dario rsepon ro P Pr Y Report Informat' Company Nam j j ` Q Circle Requested T d me (Less than 2 Days most be verified v4rh lab) N pl � � C 7 -70 Days S7 Day ' R/Uf /JFS.�H/�y /3-4 Days 2 Days ASAP City P Project LOCaaon./� _�/-` /, �� 11,C1 Contact Name S Project # Z} b D, �W p0 512212008 • R- 4.0 OXIDOR canrwt accept verbal changes to Mis document. Please la or emailwiitlen nwdifwatkxw Temp al Reciept 1 f. _ 'C ox -f b 4 v+rww.OXIDOR.corn a 1825 E. Piano Parkway #160 e Plano, TX 75074 a Tel: (972) 424 -6422 e Fax: (972) 424 -6508 Z QXIDOR Laboratories, LLC Chain of Custody PROJECT DESCRIPTION: Coppell Auto Ctr. OXIPOR L tlxv,ttorics, LLC: 419� 1825 East Piano Parkway. #160 Piano. TX 75D74 -8570 P'. 972 424 6,422 F. 972 424 6508 customersewice @ox idor. corn Chain of Custody Record Page — 3 — of 3 a Send Roped To Project ! Report Inn Company Nama Circle Requested Tur d ime (Less than 2 Days must be verified vdth lab) 7.10 Days 5.7 Daye RUSH 3-4 Days 2 Days ASAP Address Project Name City State Zip Project Location Name Contact ,, /�Y�`���J 5 /V/ 4 Project # PO # Contact Email Sampler Na Sampler C grpapy �����. Phone Fax a Sa Sampler ignatura Send Invoice To i DftFo It front above Matrhr. Codes Special Instructions' Company Name L - Liquid S - Solid Additim W- s A A, Presevation Codes 1 - None 4 - HCl City /' /% /Y $late g VV�� ZIP 2 HNO 5. NaOH 'Pieria confirm conditional r uesls prior to additional analysis 3 H.,SO e - Ice Contact Name Re uested Anal sls 7 - Other 9 Y Container Codes Plane Fax P - plastic G -Glass O - Other P a` o OXIDOR Order ID Sample Info a m s I c Customer Sample ID = v QGG //�� �`7 fa33! Date Time - IONS 2 � XX -01 pi1 � –031 4 N 01 , Z. 1 U Mw 03 i 1 =05 M'vJ a.3 -035 e 10 -- 22 f fo/ -0'3'd _MWo! 11 M W M - I ffr 2; _ — 031 12 (^� H'WD�i 5 - -' _. _ocf 14 .04 UW D4 - 23 -0 - % aYlypls Oy_ Alrrliet�on Date Time R-4 x by AniWtgn Unre Tme Rebquished by Alfiuetun Date Tane Received by AlNlatwn 0A. Tirrw X Relnallhhed by x AReatdn Date Tlme x R-.,.d if t� b ��J hare /� Time / by v/ 3/22/2008 - Rev. 1.0 auomrtra o aemp.. sgnxws p".. or .. WFI 151 alarms and DendNens OXIDO0. cannot accept —W charges to this document Ploa ar nl 0 .ldten moddkations CT ACCoy Order ID: 0910331 Date: 10/26/2009 Page 30 of 30 T104704227 -09 -TX Tmmp al Reciep^ °C LL www.OXIDOR.com a 1825 E. Plano Parkway #160 a Plano TX 75074 e Tel: (972) 424 -6422 - Fax: (972) 424 -6508 Chain ®f Custody Record 1825 cast Plano Pzr;v, 6O c % , Piano, T, 7507 -8670 0 � Page I of P 972 ^2z. 6!22 F 9'/2 �2 6508 P f z custcmerservlce c oxi6c,o, ro z Send Report 1 o Project / Report Information Company Name t y l Circle Requested Tu me (Less than 2 Days must be verified with lab) t�J r f..fVdti ✓rmro e^,y 7 -10 Days 5 _D_Days RUSH 3 -4 Days 2 Days ASAP Address Project Name t �6a� E f��>�, s City 91'.111c, State -- Zip _ Project Location Contact Name P Project #.�q PO # Contact Email / Sampler Name Sampler Company _ C C (.,.roc :a!!�a -wa, �€�+l 5. wt VC t h1wr am fT,.asn Phone r — r t i Fax 1 Sampler Signature pl t' Send Invoice To (Only if Different from above Matrix Codes Special Instructions' Company Name L - Liquid S - Solid W -Wipes A -Air Address o' Presevation Codes - �A - -_ 1 -None 4 - HCI (; ItV i State ZID 9 - HNl7.. 5 - NanH *Plaasa rnnfirm cnnrl itinnal ranllPS }a nrinr in aririitinnal analysis v Contact Name 3 - t 6 -Ice 7 - O O ther her Time Received by Requested Time lelinquished by Affiliation Date Analysis Received by Affiliation Date Time Phone Fax Container Codes P - Plastic G -Glass X '.elinquished by Affiliation Date Time Received for OR by Y Date 17 Time m O - Other f J 1 3 5 � Submittal of samples signifies acceptance of OXIDOR's StadArd Terms and Conditions L 3 U m L U 3 c_ � iv OXIDOR Order ID Sample Info Customer Sample ID x tj C "R O U E u O N O E p 4 3 1 Date Time m `o o U o o t V 40 j ZI X ` 2 513 Olt 0 0 3 3 513 00 � -4 10/1 - i 1 s 5 p //� d �) Q 6 — `�� S 06 9 r'4l<. In 2- � ' 7 SP3 s"rrI z'SO 0of) 8 a �� g J Oil F' �' r r1 Q 10 _ 0 i 11 SA 6M1 12 _ r C) l 13 14 15 shed by Affiliation Date . N � M 10[ � /"o Time Received by Affiliation Date Time lelinquished by Affiliation Date Time Received by Affiliation Date Time X '.elinquished by Affiliation Date Time Received for OR by Y Date 17 Time I x f J 1 3 5 Submittal of samples signifies acceptance of OXIDOR's StadArd Terms and Conditions 5/22/2008 - Rev. 4.0 OXIDOR cannot accept verbal changes to this document. Please fax or email written modifications Temp at Reciept '7 • °C 1825 cast PlunO �''af {ONa,'. '., , 0 Plano, TX i507� -8570 > P: 0 ,72.- 2n.6k22 F: 972 4c^.6�308 custornef erJice @cxido. coiTf Chairs Of Custody Record g 54 ', Rage 2— of .5 4 s Send Report To Project/ Report InformaU Company Name ,�, / Circle Requested T r nd me (Less than 2 Days must be verified with lab) 7 -10 Days 5 -7 Day RUSH 3 -4 Days 2 Days ASAP Address q f Project Name J / ��� City + State +. Zip " . � Project Location J 1 A Contact Name ' Project # ( PO # Contact Email 1 l � _'f•Lt^T/f8�8„- `6'8..• L��'' = Sam ler Name Sam ler Company P �J P Y - _ ___ "° 8:_�sY i�Vr�. �i14 :. - Phone ( Fax Fe ./ Sampler Signature E e Send Invoice To (Only if Different from above Matrix Codes Special Instructions Company Name L - Liquid S - Solid W -Wipes A - Air Address Presevation Codes 1 -None 4 - HCI City /�MfState Zip 2 - HNO 5-NaOH 'Please confirm conditional requests erior to additional analysis Contact Name 3 -H SO 6 -Ice 2 Requested Analysis 7 - Other Container Codes Phone Fax P - Plastic G - Glass N o� O - Other t U d r m R m U 0 OXIDOR Order ID Sample Info � ° c �? a) E Customer Sample ID o __ a W M 0 Date Time m `o o o m o o U 0- a x @r Sib Ok- -2 �' rafr� Fo-f g ` S �. G t� C� -air 2 � d '`f 3 � 4 S 0 1 2 L 513 0/2 '/fi�� l t,�d `r i� -are! 7 so ��; -- `��� ���i� � o f r�5" s z 6 �p p g 013 G 2� 10 1 5 6 3 Llv 11 11 Ed � ! v � o := 3 0 3 -� I0f� t/ I X < y H 12 56 01z - i 15 Relfi�lu�is�he,,d,� O/ J ' Affiliation D�tp„ % / Time �� Received by X Fi ' Y�?�J'Z' VV X Relinquished by Affiliation Date Time Received by X X Relinquished by Affiliation Date Time Received for X X Submittal of samples signifies acceptance of OXIDOR's Stand 5/22/2008 - Rev. 4.0 OXIDOR cannot accept verbal changes to this document. Please fax Affiliation Date I ime Affiliation Date Time by % � f j /J late Time a d 17 t J - arms and Conditions email written modifications. Temp at Reciept °C (ix' - 4 1825 East Piano Parkw2y.::'tiBO Plano, TX 750k-8570 P: 972.24 642?. F: 972. customerseivice @oxidor.com 5eno Kepon i o Customer Sample ID p Company Name A Address c _ 6 City State Zip 1°' ( c _ Contact Name Date Contact Email -o �g Phone Fax Send Invoice To (Only d Different from above) Company Name Time Address City State Zip h (� Contact Name Phone Fax Chain Of Custody Record Page __,�)_ of 3 b U U m S Q Project / Report Inform Circle Requested Tur d ime (Less than 2 Days must be verified with lab) 7 -10 Days 5 -7 Days RUSH 3 -4 Days 2 Days ASAP Project Name Project Location Project # PO # Sampler Na Sampler Compa y f / �J Sampler Signature Matrix Codes Special Instructions' L - Liquid S - Solid W -Wi es A -Air Presevation Codes 1 - None 4 - HCI 2 - HNO 5-NaOH `Please confirm conditional requests prior to additional analysis 3 - H 6 - Ice Requested Analysis 7 - Other Container Codes N P - Plastic G -Glass - m O - Other e s d OXIDOR Order ID 3 i \ J Customer Sample ID p Sample Info X o # c _ 6 ° N a- �? a E U 1°' ( c _ Time Date Time -o �g r� -� ✓ r- i ��,� j� r J: Affiliation Date Time G6 X h X KW oll X0 ft4W 01 i 1tl r �A �j 9 i'�1rV 03 -- p lotel 1 2 ^ 7 ss 8 AW 0? t k 1C/i51�t I ..�2� g io v n j 10 _�, If , , I 0q —03 12 �_ t) t1 AA ` (� f 13 k iv /00 KA 1 - � "1'� 15 r•VGAV rs� & � cu3 W V4 •- t R shed by�/� X G' I,�IG�•._.�_ Affiliation Date W k rn l0 1 c�0� Time - 3S Received by X Relinquished by _ Affiliation Date Time Received by X x Relinquished by Affiliation Date Time Received f94 X X Submittal of samples signifies acceptance of OXIDOR's 5/22/2008 - Rev. 4.0 OXIDOR cannot accept verbal changes to this document If 3 Q N N N � p O o 0 L 6 � U Affiliation Date Time Affiliation Date Time 2 by Date Time x 7 35 d Terms and Conditions �y or email written modifications Temp at Reciept ox -�(