SS9301-CS 930713 Coppell, Texas 75019
,~..~ ~. 214-462-0022
The City With A Beautiful Fulure ~'~ 5 ~'~""O1
July 13, 1993
Mr. Wayne Ginn
Ginn, Inc.
17103 Preston Road Suite 205
Dallas, TX 75248
RE: Request for Point of Entry to Trinity River Authority/Grapevine Sanitary Sewer Line
Phase I
Dear Mr. Ginn:
Per our conversation yesterday afternoon, I informed you that I had received a call from Bob
Roth with Trinity River Authority. Bob had requested that the City submit a point of entry
request for the new 30" tie-in to the 33" TRA interceptor.
In speaking with Ken Griffin, he has asked that your office complete this packet and return
to his office for his signature.
If you. have any questions r~r~gar~ling this~matter, please advise.
~in~ely, ;? ~J
H~ow~d~~L paff(~or~ ~ v;[ ~,.~ -
Utilities S~perintendent /
HLP/dm
cc: Steven G. Goram, Director of Public Works
Ken Griffin, City Engineer
Attachments
TRINITY RIVER AU[HORITY OF TE'~'''-,
NORTHERN REGION PROJECTS
REQUEST FOR A POINT OF ENTRY
CONTRACTING PARTY:
PROPOSED PROJECT NAME:
DESIGN ENGINEER:
CONTACT: TELEPHONE NO.:
LOCATION OF PROPOSED CONNECTION (TRA NOMENCLATURE). NOTE: DETAILS CONCERNING
TRA INTERCEPTORS ARE AVAILABLE FROM THE INDIVIDUAL PROJECT BUT SHOULD BE
FIELD VERIFIED PRIOR TO SUBMITTAL.
PROJECT: CRWS TMCRWS ROCRWS DCRWS
INTERCEPTOR:
STATION NO.:
PLANNED LAND USE FOR THE AREA TO BE SERVED:
ACREAGE:
INITIAL FLOW EXPECTED: MGD (DAILY AVERAGE) MGD (PEAK)
ULTIMATE FLOW EXPECTED: MGD (DAILY AVERAGE) MGD (PEAK)
BASIS FOR ESTABLISHING FLOWS:
'TYPE OF CONNECTION:
EXISTING MANHOLE: CONSTRUCT MANHOLE:
SIZE OF CONNECTION: SLOPE AT CONNECTION:
MATERIAL OF CONNECTION:
METERING FACILITY PROPOSED? YES NO
IF YES, EASEMENT DOCUMENTS FOR THE METER STATION, ACCESS ROAD AND
PERMANENT ELECTRIC UTILITY MUST ACCOMPANY THIS REQUEST.
TYPE:"
ATTACHMENTS ACCOMPANYIi~G THIS REQUEST CONTAIN: (PLEASE CHECK)~
CONNECTION: METERING FACILITY:
PLAN SHEETS PLAN SHEETS
PROFILE SHEETS PROFILE SHEETS
SPECIFICATIONS CONSTRUCTION PRINTS
CONSTRUCTION SPECIFICATIONS
INSTRUMENTATION SUBMITTALS
GENERAL:
SERVICE AREA MAP TO INCLUDE DRAINAGE AREA, CITY BOUNDARIES, AND NAME OF
DEVELOPMENT
REQUEST TO BE SIGNED BY THE
CONTRACTING PARTY:
'NAME:
SIGNATURE:
DATE:
TITLE:
CONTRACTING PARTY:
~ REQUESTS WITHOUT THE ABOVE INFORMATION WILL BE DELAYED UNTIL ALL THE
INFORMATION IS RECEIVED.
TRA PROJECT NOMENCLATURE AND ADDRESS OF PROJECT ARE REPRESENTED AS FOLLOWS:
Central Regional Wastewater System Ten Mile Creek Regional Wastewater
P.O. Box 531196 System
Grand Prairie, Texas 75053-1196 Malloy Bridge Road, Route 2, Box 136
Ferris, Texas 75125
Tarrant County Water Supply Project Denton Creek Regional Wastewater
ll201Mosier Valley Road System
Euless, Texas ?6039 P.O. Box 1259
Roanoke, Texas 76262
Red Oak Creek Regional Wastewater System
TRINITY RIVER AUTHORITY OF TEXAS
PERMIT REQUEST FORM
Submit Permit Request To: (Check The Appropriate TRA Project)
Central Regional Wastewater System (CRWS)
Technical Services Engineer
P.O. Box 531196
Grand Prairie, Texas 75053-1196
(214) 263-2251 or (214) 262-5186
Tarrant County Water Supply Project (TCWSP)
Project Manager
11201 Nosier Valley Road
Euless, Texas 76039
(817) 267-4226 or (817) 267-4227
Ten Nile Creek Regional Wastewater System (TMCRWS)
Project Manager
Malloy Bridge Road, Route 2, Box 136
Ferrts, Texas 75125
(214) 225-3462 or (214) 225-5538
Denton Creek Regional Wastewater System (DCRWS)
Project Manager
P.O. Box 1259
Roanoke, Texas 76262
(817) 430-4657
Red Oak Creek Regional Wastewater System (ROCRWS)
Permit for construction to be issued to: (Title Owner of Property)
Name
Street
City State Zip Code
Telephone Contact:
Name Telephone Number
Permit for operation and maintenance to be issued to: (i.e., individual,
developer, city)
Name
Street
City State Zip Code
Telephone Contact:
Name Telephone Number
Engineering Firm:
Contact Name Telephone Number
Street City Zip Code
Details must be submitted on all proposed modifications of TRA facilities
including plan and profile sheets of each crossing and initial and final ground
elevations within the facility's easement boundary.
Attachments: Plans and Profiles Location Map
Proposed Project Name:
Submitted by: Date:
Telephone Number:
Date of Plans: Proposed Project Start Date:
PROPOSED PERMIT MODIFICATIONS
Utility Crossin~
1 2 3
SIZE TYPE CLEARANCE TRA FACILITY TRA STA NO.
inch
inch
inch
inch
inch
inch
inch
inch
Pavements
STREET NAME OR DRIVEWAY CLEARANCE TRA FACILITY TRA STA NO.
Fill
MAXIMUM AMOUNT FINAL
OF FILL (ft} ELEVATION {ft} TRA FACILITY TRA STA NO.
Excavation
MAXIMUM AMOUNT FINAL
OF EXCAVATION (ft) ELEVATION (ft) TRA FACILITY TRA STA NO.
Manhole Adjustment
FINAL
HEIGHT ADJUSTED (ft) ELEVATION (ft) TRA FACILITY TRA STA NO.
Miscellaneous
TRA FACILITY TRA STA NO.
CLEARANCE - the number of feet between the proposed modification and the
Authority's facility. The clearance should indicate if the modifications
are to be above, below or next to the Authority's facilities.
TRA FACILITY - pertains to wastewater interceptors, water pipelines, meter
stations, lift stations, etc... TRA facility plans may be obtained from
the appropriate Project.
3
TRA STATION NUMBER - TRA station numbers can be obtained from the
appropriate Project's as-built construction plans and must be included on
the Permit Request Form.
TRA USE ONLY
NORTHERN REGION NUMBER:
APPROVED BY: DATE: