ST9302-LR010520 (2) ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 l enort
(972) 620-8911
Tested For: CITY OF COPPELL Our Report No.: 98881-194
ATTN: KEN GRIFFIN Issue Date: 05/20/2001
255 PARKWAY BLVD.
COPPELL, TX 75019
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
FIELD DA TA
Placement Location: WALL @ STATION 4+90
Date Placed: 4/20/01 Plant Number: N/A
Time Placed: N/A Delivery Ticket No.: N/A
Slump (ASTM C-143): N/A Made By: CONTRACTOR
Air Content: N/A
Air Temperature: N/A Cured Specification: ASTM C-31
Specimen Temperature: N/A
Date Received: 5/2/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: CONTRACTOR
Mix Data Submitted By: N/A
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
270 LAB C-617 5/2/01 12 12 N/A 6 28.27 119616 4230
271 LAB C-1231 5/18/01 28 12 N/A 6 28.27 143155 5060
272 LAB C-1231 5/18/01 28 12 N/A 6 28.27 145390 5140
273 LAB HOLD HOLD 12 N/A 6 28.27 0
~pe~ifi?tio~! 28 4000J
Results to Date: PASS
Notes: CONTRACTOR MADE CYLINDERS