Loading...
ST9302-LR010520 (2) ALPHA TESTING, INC. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 l enort (972) 620-8911 Tested For: CITY OF COPPELL Our Report No.: 98881-194 ATTN: KEN GRIFFIN Issue Date: 05/20/2001 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS FIELD DA TA Placement Location: WALL @ STATION 4+90 Date Placed: 4/20/01 Plant Number: N/A Time Placed: N/A Delivery Ticket No.: N/A Slump (ASTM C-143): N/A Made By: CONTRACTOR Air Content: N/A Air Temperature: N/A Cured Specification: ASTM C-31 Specimen Temperature: N/A Date Received: 5/2/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: CONTRACTOR Mix Data Submitted By: N/A CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 270 LAB C-617 5/2/01 12 12 N/A 6 28.27 119616 4230 271 LAB C-1231 5/18/01 28 12 N/A 6 28.27 143155 5060 272 LAB C-1231 5/18/01 28 12 N/A 6 28.27 145390 5140 273 LAB HOLD HOLD 12 N/A 6 28.27 0 ~pe~ifi?tio~! 28 4000J Results to Date: PASS Notes: CONTRACTOR MADE CYLINDERS Respectfully Submitted By: ,//x~,,~ /./~',~,, of Alpha Testing, Inc. Our test results and reports are for the exclusive use°f the Client(and/~elr designated recepients on file In our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not IndicatiVe of the qualities of apparently Identical or similar specimens.