Loading...
ST9302-LR010510 ALPHA TESTING, INC. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 l enort (972) 620-8911 Tested For: CITY OF COPPELL Our Report No.: 98881-185 Aqq'N: KEN GRIFFIN Issue Date: 05/10/2001 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS FIELD DA TA Placement Location: PIER CAP; E. BOUND SANDY LAKE @ STATION 15+55 Date Placed: 4/5/01 Plant Number: 27-4000 Time Placed: 4:45 PM Delivery Ticket No.: 695154 Slump (ASTM C-143): 4 Made By: ALPHA Air Content: N/A Air Temperature: 67 Cured Specification: ASTM C-31 Specimen Temperature: 75 Date Received: 4/6/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: RANJBARAN, JAMSHID Mix Data Submitted By: PIONEER CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 262 LAB C-617 4/12/01 7 12 N/A 6 28.27 117769 4160 263 LAB C-617 5/3/01 28 12 N/A 6 28.27 142941 5050 264 LAB C-617 5/3/01 28 12 N/A 6 28.27 135964 4810 265 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 i Results to Date: PASS Notes: Respectfully Submitted By: ~/7/~ _//,,~,4~'_~- of Alpha Testing, Inc. - / Our test results and reports are for the exclusive use of the Client (an~'thelr designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test resull3 must receive our written approval. Test results and reporl3 apply only to the samples tested and/or observed, and are not indicative of the qualifies of apparently Identical or similar specimens.