ST9302-LR010510 ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 l enort
(972) 620-8911
Tested For: CITY OF COPPELL Our Report No.: 98881-185
Aqq'N: KEN GRIFFIN Issue Date: 05/10/2001
255 PARKWAY BLVD.
COPPELL, TX 75019
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS
FIELD DA TA
Placement Location: PIER CAP; E. BOUND SANDY LAKE @ STATION 15+55
Date Placed: 4/5/01 Plant Number: 27-4000
Time Placed: 4:45 PM Delivery Ticket No.: 695154
Slump (ASTM C-143): 4 Made By: ALPHA
Air Content: N/A
Air Temperature: 67 Cured Specification: ASTM C-31
Specimen Temperature: 75
Date Received: 4/6/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: RANJBARAN, JAMSHID
Mix Data Submitted By: PIONEER
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI:
262 LAB C-617 4/12/01 7 12 N/A 6 28.27 117769 4160
263 LAB C-617 5/3/01 28 12 N/A 6 28.27 142941 5050
264 LAB C-617 5/3/01 28 12 N/A 6 28.27 135964 4810
265 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 4000
i Results to Date: PASS
Notes:
Respectfully Submitted By: ~/7/~ _//,,~,4~'_~- of Alpha Testing, Inc.
- /
Our test results and reports are for the exclusive use of the Client (an~'thelr designated recepients on file in our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test resull3 must receive our written approval. Test results and reporl3 apply only to the samples tested and/or
observed, and are not indicative of the qualifies of apparently Identical or similar specimens.