ST9302-LR010508 (3) ALPHA TESTING, INC.
Concrete
Test
su, o , om ,ress.on
Dallas, Texas 75229 ''t' -~enort
(972) 620-8911
Tested For: CITY OF COPPELL Our Report No.: 98881-194
A'I-i-N: KEN GRIFFIN Issue Date: 05/08/2001
255 PARKWAY BLVD.
COPPELL, TX 75019
Fax Number: (972) 304-3570
Project Desc: SANDY LAKE ROAD PROJ NO. ST 93
COPPELL, TEXAS
FIELD DA TA
Placement Location: WALL @ STATION 4+90
Date Placed: 4/20/01 Plant Number: N/A
Time Placed: N/A Delivery Ticket No.: N/A
Slump (ASTM C-143): N/A Made By: CONTRACTOR
Air Content: N/A Cured Specification: ASTM C-31
Air Temperature: N/A
Specimen Temperature: N/A
Date Received: 5/2/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: CONTRACTOR
Mix Data Submitted By: N/A
CYLINDER COMPRESSION TEST RESUL TS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: T~pe: Spec: Tested: tDaysl: Len~lth Width Diameter S(~. In. Load: PSI:
270 LAB C-617 5/2/01 12 12 N/A 6 28.27 119616 4230
271 LAB 5/18/01 28 12 N/A 6 28.27 0
272 LAB 5/18/01 28 12 N/A 6 28.27 0
273 LAB HOLD HOLD 12 N/A 6 28.27 0
28 4000
Specifications:
Results to Date: N/A
Notes: CONTRACTOR MADE CYLINDERS
Respectfully Submitted By: /~[J of Alpha Testing, Inc.
Our test resull3 and report~ are for the exclusive use of the Client (and their de$1~ated receplent~ on file In our office) and shall not be reproduced and/or distributed except
with express approval of ALPHA. The u~e of our name and tea result~ must receive our wrilZen approval. Test result~ and report~ apply only to the samples tested and/or
observed, and are not indicative of the qualities of apparenty Identical or similar specimens.
Geotechnlcal Engineering * Construction Materials Testing * Environmental Engineering * Consulting 7707