Loading...
ST9302-LR010508 (4) ALPHA TESTING, INC. Concrete Test 2209 Wisconsin St.. Suite 100 ,_.omt, ress,on Dallas, Texas 75229 -°e"or, (972) 620-8911 Tested For: CITY OF COPPELL Our Report No.: 98881-193 ATTN: KEN GRIFFIN Issue Date: 05/08/2001 255 PARKWAY BLVD. COPPELL, TX 75019 Fax Number: (972) 304-3570 Project Desc: SANDY LAKE ROAD PROJ NO. ST 93 COPPELL, TEXAS FIELD DA TA Placement Location: WALL @ STATION 15+50 Date Placed: 4/11/01 Plant Number: N/A Time Placed: N/A Delivery Ticket No.: N/A Slump (ASTM C-143): N/A Made By: CONTRACTOR Air Content: N/A Cured Specification: ASTM C-31 Air Temperature: N/A Specimen Temperature: N/A Date Received: 5/1/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: CONTRACTOR Mix Data Submitted By: N/A CYLINDER COMPRESSION TEST RESUL TS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: T}/pe: spec: Tested: (Daysl: Len~lth Width Diameter Sq. In. Load: PSI: 266 LAB C-617 5/2/01 21 12 N/A 6 28.27 120496 4260 267 LAB 5/9/01 28 12 N/A 6 28.27 0 268 LAB 5/9/01 28 12 N/A 6 28.27 0 , 269 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 4000 Results to Date: N/A Notes: CONTRACTOR MADE CYLINDERS Respectfully Submitted By: of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not Indicative of the qualities of apparently Identical or similar specimens. Geotechnlcal Engineering * Construction Materials Testing * Environmental Engineering * Consulting 7706