Loading...
ST8504-CS 870507CONTRACTING PARTY: PROPOSED PROJECT NAME~ DESIGN ENGINEER: CONTACT: Janet Vick '~,,.[NITY RIVER AUTHORITY OF TEXAS NORTHERN REGION PROJECTS REQUEST FOR A POINT OF ENTRY City of Coppell Riverchase Nathan D. Maier Consulting Engineers, Inc. TELEPHONE NO. 739-4741 I"U-k K t.,H ~0 ATTACHMENT A LOCATION OF PROPOSED CONNECTION (TRA NOMENCLATURE). NOTE: DETAILS CONCERNING TRA INTERCEPTORS ARE AVAILABLE FROM THE PROJECT BUT SHOULD BE VERIFIED IN THE FIELD PRIOR TO SUBMITTAL.' PROJECT CRWS x TMC INTERCEPTOR: Coppell STATION NO.: 130 + 40~ PLANNED LAND USE FOR THE AREA TO BE SERVED: See enclosed zonings'exhibit. · ACREAGE: 326 INITIAL FLOW EXPECTED: 0.05 ULTIMATE FLOW EXPECTED: 1.30 BASIS FOR ESYABLISHING FLOWS: MGD (DAILY AVERAGE) 0.125 MGD (DAILY AVERAGE) 3.25 100 Gal/person/day MGD (PEAK) MGD (PEAK) Based on 3.6 persons per single family residence or 3.6 persons per multi- family unit at designated zoning density. TYPE OF CONNECTION:' EXISTING MANHOLE: SIZE OF. CONNECTION: MATERIAL OF CONNECTION: 15 Inch P.V.C. CONSTRUCT MANHOLE~ x SLOPE AT CONNECTION' ~15% METERING FACILITY PROPOSED? TYPE YES' x NO