PA0101-LR010518 GEOTECHNICAL AND j ~ J=~J I-'1 U P
ENVIRONMENTAL CONSULTANTS
I
CONCRETE CYLINDER TEST REPORT
Coppell Tech Center II
1322 Crestside
Coppell, Texas
REPORTED TO: Bob Moore Construction Co. REPORT NO. 111
1110 N. Watson Road REG PROJECT NO. 7044
Arlington, Texas 76011 SAMPLE DATE: 05-18-01
ATTN: Mr. Ed T. McGuire TECHNICIAN: D. French
CONTRACTOR: Bob Moore Construction Co.
Location of Sample
Set Number I Location I Quantity Represented
1 Sidewalk: 2'S, 390'E of S.W. building corner 10/70
Design Information
Source of Concrete I Mix Identification I Specified Strength p.s.i.
TXI 8204 3000
Test Results
Set Cylinder Age@ Total Load J CompressiveI Average
No. ID Date Tested Test lbs. I JStrength p.s.i. Strength p.s.i.
1 7862 05-25-01 7 98420 3480
7862 06-15-01 28
7862 06-15-01 28
7862 Hold H
Cylinder Data
Set Cylinder Time of Concrete J Air Ticket
No. ID Slump Sample Air Temp. Temp.J Entrainment Number
1 7862 4.50 11:00AM 79 92 N/A 2893519
Mail Submitted by:
Distribution: (1) Bob Moore Construction Co./
Mr. Ed T. McGuire REED ENGINEERING GROUP, INC.
(1) City of Coppell/Mr. Larry Davis
(1) City of Coppell/Mr. Lee Stone Original Signed By
(1) McHale Consulting Engineering/
Mr. Gary McHale Keith Atkins
(1) CMC-Commercial Realty/ KEA/je
Mr. Steve Huff
(1) AECC, Inc./Mr. Chad Stevens
2424 STUTZ DR. · SUITE 400 · DALLAS, TX 75235 * TEL [214] 350 5600 · FAX [214] 350 0019