Loading...
PA0101-LR010524CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0008 Dallas, Texas 75247 Service Date: April 24, 2001 214) 63o-1010 Client: City of Coppell - Parks & Recreation Rep( Attn: Brad Reid 732 DeForest Coppell TX 75019 Proje Material Information Sam ~tion Specified Strength: 3000 psi @ 28 Days Sample Time: 12:25pm Date Cast: April 24, 2001 Technician: Terry L. Smith Batch Time: 12:07pm Plant: 41 Weather Conditions: Clear, windy Supplier: TXl Accumulative Yards: 4 Truck No: Ticket No: 2871036 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See placement location Placement Location: Paving- Parking (See attached sketch) Field Test Data Test Result Specification Test Method Slump, inches: 6.00 5.0 Max ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature,O F: 74 ASTM C-39 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 05/01/2001 7 76,980 2,720 1 2 6.00 05/01/2001 7 78,300 2,770 ~ Awrage .:J~0' 50 1 3 6.00 05/22/~~'~ 2{:j 132~100 4,6'7~ 1 4 6.00 05/22/~0(r 28 133,990 4,740 '~ ~.~ Average 4,~ Services - Obtain samples of fresh concrete at the placement Iocatic~['f%, ~.:.-f::.~.. _-"";":-nd fi~l¢ tests --7~ll~cast compressive strength samples. The tests were performed in general accordance with applicable ASTIvl, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 3 0, CONCRETE COMPRESSIVE STRENGTH TEST ENGIN ~EERING, INC, 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0008 Dallas, Texas 75247 Service Date: April 24, 2001 (214) 63O-lO10 Client: City of Coppell - Parks & Recreation Report Date: May 24, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information 3pecified Strength: 3000 psi @ 28 Days Sample Time: 1:50pm Date Cast: April 24, 2001 Technician: Terry L. Smith Batch Time: 1:21pm Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 110 Truck No: 712 Ticket No: 2871206 Placement Method: Direct discharge Mix I.D. Ne,: 8272 Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 5.0 Max ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature,O F: 75 ASTM C-39 Ambient Temperature, 0 F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 2 1 6.00 05/01/2001 7 103,480 3,660 2 2 6.00 05/01/2001 7 99,510 3,520 Average 3,590 2 3 6.00 05/22/2001 28 119,730 4,230 2 4 6.00 05/22/2001 28 120,710 4,270 Average 4,250 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 °' b~W'~l ~1~'~'~'~ CONCRETE COMPRESSIVE STRENGTH TEST EN(J'INEEPJK(], INC. 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0008 Dallas, Texas 75247 Service Date: April 24, 2001 (214) 63O-lO10 Client: City of Coppell - Parks & Recreation Report Date: May 24, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 3:05pm Date Cast: April 24, 2001 Technician: Terry L. Smith Batch Time: Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 220 Truck No: 867 Ticket No: 2871361 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 5.0 Max ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature, o F: 76 ASTM C-39 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 3 1 6.00 05/01/2001 7 94,790 3,350 3 2 6.00 05/01/2001 7 94,130 3,330 Average 3,340 3 3 6.00 05/22/2001 28 112,200 3,970 3 4 6.00 05/22/2001 28 106,610 3,770 Average 3,870 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: Inc. (1) City of Coppell - Parks & Recreation (1) TLB Construction Reviewed bY: C"'" ~'~ric~Jj ~v; (1) City of Coppell - Constr. Insp. . land, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3 o~ CONCRETE COMPRESSIVE STRENGTH TEST E2~;1NEEP, ING, INC. 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0008 Dallas, Texas 75247 Service Date: April 24, 2001 (214) 63O-lO10 Client: City of Coppell - Parks & Recreation Report Date: May 24, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 3:05pm Date Cast: April 24, 2001 Technician: Terry L. Smith Batch Time: Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 220 Truck No: 867 Ticket No: 2871361 Placement Method: Direct discharge Mix I.D. No.: 8272 Sample Locations: See page 1 Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 5.0 Max ASTM C-143 Air Content, %: ASTM C-172 Concrete Temperature,© F: 76 ASTM C-39 Ambient Temperature, o F: 79 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 3 1 6.00 05/01/2001 7 94,790 3,350 3 2 6.00 05/01/2001 7 94,130 3,330 Average 3,340 3 3 6.00 05/22/2001 28 112,200 3,970 3 4 6.00 05/22/2001 28 106,610 3,770 Average 3,870 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: Inc. (1) City of Coppell - Parks & Recreation (1) TLB Construction Reviewed by:C,/" /////z/- ( ., (1) City of Coppell - Constr. Insp. (-"/' ~ric J. ~veland, P.E. Senior Project Engineer The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3 °'