ST1002-CS110525 (3)Page 1 of 1 Keith Marvin - FW: Old Coppell townhomes From: Chris Poteet <cjpgfreese.com> To: "'Keith Marvin' (kmarvingcoppelltx.gov)" <kmarvingcoppelltx.gov> Date: 5/25/2011 12:52 PM Subject: FW : Old Coppell townhomes Attachments: clearances of padmounted equipment from buildings.PDF X Chris Poteet Freese & Nichols, Inc. From: Karen. Eastman @oncor.com [mailto: Karen. Eastman @oncor.com] Sent: Tuesday, May 24, 20117:38 PM To: gregyancey @verizon.net; Chris Poteet Cc: rick.fielding @oncor.com Subject: Old Coppell townhomes After thinking about everything and the distances I heard mentioned in the meeting today, I don't see any way that we can maintain our clearance requirement between the transformers and the garage structures. We have to maintain 5 ft. between the transformer pads and a 2 hour fire rated wall. If there are doors, windows, or vents the distance increases to 10 ft. have attached our clearance requirements for your use. Please review and let me know your findings. Thank You, Karen Eastman New Construction Manager Oncor Electric Delivery 200 North Ector Euless, Texas 76039 Office 817 - 355 -7050 Fax 817 - 355 -7090 This I1ectr ini c mad i message is intended h i ll for the individuall or entity to Ihi lh it is fir . This i message, together with any attachment, ima contain the ender' s organization's coinfi anti ll and privfleged information. The fir it i int is hereby iinotified to treatthe information as confidentiall and Iprivfleged and to iii t disdose or use the information except as authorized Iby sender's it ini ti in. Any unauthorized fireview, printing, firetention, Il yin , disdosure, distribution, firetransmission, i it linati in or other use of, or taking of any action in rehance upon, this information Iby persons it entities other than the intended r i l i int is I prohibited. If you fireceived this i message in error, I pIlease immediat6ly contact the fin er Iby r l ll fr ill and d6lete II II copies of the imateri ll from any computer. Thank you for your cooperation. file: / /C: \Documents and Settings \radloo \Local Settings \Temp \XPgrpwise \4DDCFB85Cit... 10/24/2011 NOTE 4\ A CONTAINMENT TRANSFORMER PAD DIKE, NOTE 5 111 1 A -OW PLAN FIRE WINDOW OR VENTILATING DUCT TRANSFORMER NOTE 7 NOTE 6 NOTE 6 NOTE 6 FIRE ESCAPE ELEVATION TRANSF. TYPE BUILDING CONSTRUCTION WINDOWS, DOORS & VENTS FIRE ESCAPES FIRE RESISTIVE NON- FIRE RESISTIVE NOTE 3 1 PHASE 5' -0" 10' -0" 10' -0" 20' 4" 3 PHASE 5' -0" 15' 4" 15' -0" 20' -0" CLEARANCE TABLE NOTES: CONTAI DIKE, N BUILDING OR STRUCTURE 1. CLEARANCE FROM BUILDING WALLS SHALL COMPLY WITH THE CLEARANCE TABLE. ALL DIMENSIONS SHOWN ARE MINIMUM DIMENSIONS. 2. WHERE THERE ARE BUILDING EAVES OR OVERHANGS WITHIN 25'- 0' ABOVE GROUND, CLEARANCE SHALL BE MEASURED HORIZONTALLY BEGINNING FROM THE EDGE OF THE EAVE OR OVERHANG. 3. FIRE RESISTIVE BUIILDING WALLS INCLUDE BRICK AND MASONRY STRUCTURES THAT HAVE A 2 HOUR FIRE RATING. 4. CLEARANCE TO BUILDING DOORS, WINDOWS, VENTS AND FIRE ESCAPES TO BE MEASURED RADIALLY. 5. LIQUID FLOW OF AREA SURROUNDING TRANSFORMER SHOULD BE AWAY FROM BUILDING. WHERE GROUND IS FLAT OR SLOPES TOWARD BUILDING, A DIKE SUFFICIENT TO CONTAIN ALL TRANSFORMER OIL FOR TRANSFORMERS 500 KVA AND LARGER SHALL BE PROVIDED. 6. CLEARANCES ARE MEASURED FROM PAD EDGE TO BUILDING WALL, OPENING, OVERHANG OR FIRE ESCAPE UNLESS A CONTAINMENT DIKE IS UTILIZED, IF A CONTAINMENT DIKE IS UTILIZED, CLEARANCE IS MEASURED FROM DIKE. 7. CLEARANCES FOR WINDOWS AND VENTS ABOVE TRANSFORMER ARE MEASURED RADIALLY FROM CLOSEST POINT ON TRANSFORMER. B. PADMOUNTED TRANSFORMERS SHALL BE POSITIONED SUCH THAT HOTSTICK USE IS NOT REQUIRED ON THE SIDE FACING THE BUILDING. IF HOTSTICK USE IS REQUIRED ON THE BUILDING SIDE, CLEARANCES SHOWN IN DETAIL SHEET 50 SHALL BE MAINTAINED. 9. THERE SHOULD NOT BE ANY ABOVE GROUND OBSTRUCTIONS, SUCH AS SHRUBS, COOLING TOWERS, GAS METERS, FENCING, ETC. WITHIN 5'- O' OF PAD OR OVERHANGS ABOVE PAD FACILITIES. REFERENCE DETAIL SHEET 50 FOR SCREENING CLEARANCES AROUND PADMOUNTED EQUIPMENT. 10, THERE SHOULD NOT BE ANY PIPING OR CONDUIT UNDER THE PAD (EXCEPTION: MUTUALLY AGREED UPON COMMUNICATION CONDUITS) OTHER THAN THOSE ENTERING THE TRANSFORMER. 11. TRANSFORMERS SHALL NOT OBSTRUCT FIRE LANE, 12. IT IS THE OWNER'S RESPONSIBILITY TO COMPLY WITH ANY INSURANCE REGULATIONS AFFECTING THE PREMISES. CLEARANCES OF N R PADMOUNTED TRANSFORMERS FROM BUILDINGS DDS-4 UG DETAIL SHEET 49 OF 55 DETAIL "A-A" (11/30/2011) Ken Griffin - Fw: Old Coppell townhomesPage 1 From: Keith Marvin To: Mindi Hurley, Ken Griffin, Gary Sieb CC: Clay Phillips Date: 5/25/2011 1:15 PM Subject: Fw: Old Coppell townhomes Attachments: FW: Old Coppell townhomes Fyi... Oncor has a problem with the 6 foot setback between the alley paving and the homes. Keith