ST8502-CS 850102GINN, INC. January 2, 1985 CONSULTING ENGINEERS Ashlar Contracting Company P.O. Box 713 Lewisville, TX 75067 Re: Pre-Construction Conference Moore Road Improvement Project Gentlemen: The following were in attendance at the above referenced meeting on December 17, 1985, at Ginn, Inc.: Name company Phone No. George Miller Terry Mayo Jackie Mayfield Ed Powell Glenn Fabian D. W. Mason David Vanderpool Bill Bettis David Cromer B. D. Harkins Kevin Peiffer Randy Fleming Steve Pennington Ashlar Contracting Co. Metcalf Construction City of Coppell City of Coppell Texas Power & Light Ross Concrete Continental Pipeline Lone Star Gas Lone Star Gas B & J Ginn, Inc. Ginn, Inc. Ginn, Inc. 436-5509 631-6293 462-1133 462-0022 888-1382 271-3629 318-494-5852 579-0232 670-2072 291-7811 386-6611 386-6611 386-6611 A Notice-to-Proceed was issued to the Contractor for work to begin on or before January 6, 1986 for all items except the bridge. A separate notice will be issued for the bridge after Change Order No. 1 on the bridge is approved by the City. Three hundred (300) calendar days are alotted for this project reflecting a contract completion date of November 1, 1986. Liquidated damages are $750.00 per calendar day. The following summary of the pre-construction conference serves as documentation of the items discussed and agreed upon. Any items in the contract documents not mentioned does not relieve the Contractor of those responsibilities. Ginn, Inc. is retained by the City of Coppell as administrator on this project. Ginn, Inc. will inspect all construction for conformance to plans and specifications. We will also review all payment applications and make recommendations to the Coppell City Council regarding payment. All communication will be with Ashlar Contracting Company and/or Ashlar's general superintendent, and not with any of the subcontractors. Ginn, Inc. will not supervise the construction under any circumstances. 16t 3':, Prcston Road · .qui;c 106 · Dallas. Texa~ 7'5248 · Phone 214,/ 386-6611 Ashlar Contracting Company is responsible for the means, methods, techniques, etc., for the construction of this project. Ashlar is also responsible for supervising all aspects of the construction as listed below: 1. Maintain a general superintendant on the project at all times to supervise all prime and subcontractor work. Maintain proper barricades and signage at all times through- out the project site to insure smooth traffic flow and safety around the construction and to inform anyone of any detours available for their use. (City concerned about dropoff between new and existing pavements and access for emergency vehicles.) Notify police and fire and inspector at least 24 hours in advance of any street or intersection closing and provide any detour information. Notify utility companies and coordinate work schedule with them on relocations, excavations, or any conflicts. Comply to whatever requirements they have when working around their utility. 5. Give 24 hours advance notice to the City and/or Ginn, Inc.'s inspector for any testing or inspections. 6. Maintain access at all times to properties adjacent to the project. Do Pot park vehicles, construction equipment, etc., on private property. Erect signs at each end of project prohibiting thru truck traffic. (City said that it is already prohibited.) Submit revised construction and cash flow schedules and certificate of insurance prior to beginning any construc- tion on this project. 10. Submit shop drawings on all items except RCP pipe for Ginn, Inc. review. (See specifications on submittal requirements.) 11. Stake out entire storm sewer system prior to the excavation of any pipe or box culverts. Provide inspector with cut sheets. 12. Verify all utilities, horizontal and vertical, prior to installing any storm sewer. Provide inspector with all data. 13. Keep as-built drawings. 14. Obtain all required permits from utility companies, rail- road, etc. City of Coppell requires a street cut permit prior to the installation of storm sewer across Sandy Lake Road. (There should be no charge for this permit.) 15. Any extras or change in the work, in accordance with the contract documents, must come through Ginn, Inc. office for review first. 16. City of Coppell will provide contractor with a water meter for this project. This meter is not to be used on any other job at the same time as this project. (Contractor must provide double check valves.) 17. One tenth of the total amount bid for the field office can be submitted each month on the payment applications. 18. Only the City of Coppell is to operate any water valves on this project. Call 462-9010 for City assistance. 19. Testing (densities, concrete cylinders) will be paid for by the City of Coppell. Re-tests will be paid for by the Contractor. 20. Inspector will take photographs of the site prior to the start of construction to show existing conditions. 21. Batch plant -- must meet all City, state and federal regula- tions for temporary batch plants. Provide Ginn, Inc. with mix design, calibration data, and aggregate analysis for our review and approval. Test pilot beams will be required. 22. Contractor will cast concrete cylinders. Ginn, Inc. will have a testing lab pick up and test them. During the interim, it is the responsibility of the Contractor to care for the cylinders. 23. Do not perform any work at the railroad crossing until further notice. The City of Coppell must first reach an agreement with Continental Pipeline Company. The above information is for your documentation as to what was discussed at the December 17, 1985 pre-construction conference. If you have any questions regarding this project, please do not hesitate to call. Sincerely, Kevin Peiffer Project Engineer /st