Loading...
Red Hawk-LR111015REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Creststone GroupDATE: 10/15/11 Coppell, Texas PROJECT:Red Hawk ResidentialOUR REPORT NO.:110991-20 Coppell, Texas TEST DATA:TECHNICIAN:Daniel Montenegro OPTIMUMMAXIMUM LABIN PLACEIN PLACE TESTSOIL ID ELEV. PERCENT DATECOMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 30410/15/11FG-5.5116.6106.719.3105981-A 30510/15/11FG-5.0116.6106.718.0102961-A 30610/15/11FG-4.5116.6106.718.7103961-A 30710/15/11FG-4.0116.6106.719.0104971-A 30810/15/11FG-3.5116.6106.717.5104971-A 30910/15/11FG-3.0116.6106.718.6102961-A 31010/15/11FG-2.5116.6106.719.1104971-A TEST LOCATION:Utilities 304Sanitary Sewer Manhole on Line B at Station 3+00, East Side 305Sanitary Sewer Manhole on Line B at Station 3+00, East Side 306Sanitary Sewer Manhole on Line B at Station 3+00, East Side 307Sanitary Sewer Manhole on Line B at Station 3+00, West Side 308Sanitary Sewer Manhole on Line B at Station 3+00, West Side 309Sanitary Sewer Manhole on Line B at Station 3+00, South Side 310Sanitary Sewer Manhole on Line B at Station 3+00, South Side 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Creststone GroupDATE: 10/15/11 Coppell, Texas PROJECT:OUR REPORT NO.:110991-20A Red Hawk Residential Coppell, Texas TEST DATA:TECHNICIAN:Daniel Montenegro MAXIMUM LABIN PLACEIN PLACE OPTIMUM TESTSOIL ID ELEV. PERCENT DATE COMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 31110/15/11FG-2.0116.6106.717.4106991-A 31210/15/11FG-1.5116.6106.716.41071001-A 31310/15/11FG-1.0116.6106.716.9103971-A 31410/15/11FG-7.0116.6106.716.0104981-A 31510/15/11FG-6.5116.6106.717.8103961-A 31610/15/11FG-6.0116.6106.718.5103961-A 31710/15/11FG-5.5116.6106.715.2103961-A TEST LOCATION:Utilities 311Sanitary Sewer Manhole on Line B at Station 3+00, South Side 312Sanitary Sewer Manhole on Line B at Station 3+00, South Side 313Sanitary Sewer Manhole on Line B at Station 3+00, North Side 314Sanitary Sewer Line B at Station 4+00 315Sanitary Sewer Line B at Station 4+01 316Sanitary Sewer Line B at Station 4+02 317Sanitary Sewer Line B at Station 4+04 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Creststone GroupDATE: 10/15/11 Coppell, Texas PROJECT:Red Hawk ResidentialOUR REPORT NO.:110991-20B Coppell, Texas TEST DATA:TECHNICIAN:Daniel Montenegro OPTIMUMMAXIMUM LABIN PLACEIN PLACE TESTSOIL ID ELEV. PERCENT DATECOMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 31810/15/11FG-5.0116.6106.716.2103971-A 31910/15/11FG-4.5116.6106.718.91071001-A 32010/15/11FG-4.0116.6106.718.7103961-A 32110/15/11FG-4.0116.6106.719.3102961-A 32210/15/11FG-3.5116.6106.715.0105981-A 32310/15/11FG-3.0116.6106.716.7103971-A 32410/15/11FG-2.5116.6106.717.8106991-A TEST LOCATION:Utilities 318Sanitary Sewer Line B at Station 4+06 319Sanitary Sewer Line B at Station 4+07 320Sanitary Sewer Line B at Station 4+09 321Sanitary Sewer Line B at Station 7+00 322Sanitary Sewer Line B at Station 7+01 323Sanitary Sewer Line B at Station 7+02 324Sanitary Sewer Line B at Station 7+04 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.