SW0801-LR111121 Consulting Engineering * Geotechnical Engineering * Construction Materials ALLIFINCE 3228 Halifax Street, Suite A, Dallas, Texas 75247 1 GEOTECH11IC9L Phone: (972) 444 -8889 Fax: (972) 444 -8893 GROUP C ll ' / J Z 40/2' ,,,,,/ / Acct ID: 1770 wile No: C11 -1117 Date Sampled: 11/21/201 Report Date: 11/30/2011 - -- \'` - -, Sampled By: Whitney, - Steve Project: Denton Tap Sidewalk Replacement @ Railroad Tracks By Order Of: Lrry Davis Location: Sidewalk on the Southbound side of Denton Tap 40' north and Order Number: 1770 south of railroad tracks, Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 108343 Material: Concrete Test Method: See Below Client PO: 2012 - 00000851 TEST RESULTS Report No: 108343 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Nbr (date : days) (in) (in (Ibs) Break Type Loc (PSI) (PSI) Comments A 11/28/11 : 7 6.00 28.27 91,750 Type 2 Lab 3,240 3,240 B 12/19/11: 28 6.00 28.27 Lab °. ,.„__---- -_ -- C 12/19/11 : 28 6.00 28.27 Lab D I HOLD (see remarks) - mil NH m N - Ei ,, Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification: 3,000 psi @ 28 days Date Received: 11/22/2011 Slump: 6.0 ches Transported By: Redi -Mix Curing Method: Standard it Content: 2.1% Source /Sampled At: Truck / Center Time Sampled: 1:45 pm Plant: P255 Temp.: Ambient: 59 °F Mix: 65 °F ? Mix Code: 10J11504 Truck/Ticket No: 1237 / 25406488 Unit Weight: 145.1 # /cu ft t Quantity Represented: 2 cu. yds. at 12 cu. yds. placed of a 12 cu. yd. total placement Remarks: Concrete arrived 45 minutes early. Technician sampled at end of load. Larry Davis w/ the City of Coppell was notified of low air content. Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Orig: City of Coppell (Coppell, TX) Attn: Mr. George S. Marshall, P.E. (1 -ec copy) Respectfully Submitted, Alliance Geotechnical Group 71/( /„. ., !/ 1 r Martin J. Elliott, P.E., Principal THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.