ST0501-SP111213 (6)CONCRETE December 13, 2011 To: California Construction Project: Deforest Road - Coppell RE: Submittal Documents Redi -Mix Concrete, L.P. a US Concrete Company The Technical Service Department 331 North Main St. Euless, TX 76039 Office: (817) 835 -4100 Fax: (817) 835 -4074 RedimixQC@us-concrete.com www. us-concrete.com Enclosed you will fmd the necessary submittal documents for the referenced project above for your review. Redi -Mix's strength guarantee per ASTM C94 will not be effective unless the field sampling has been done per ASTM C172 and ASTM C31 and the laboratory testing fully complies with ASTM C39 and ASTM C1077. Redi -Mix will also guarantee the strength performance of the mix designs submitted for a placement temperature between 40 °F and 100 °F provided the design plastic properties are not exceeded and the concrete is placed within 90 minutes of batch time. This concrete temperature range shall not supersede any temperature specification. All concrete should be placed and cured with the appropriate ACI guidelines and recommendations for hot and cold weather concreting. Hot weather concreting practices will require you to order ice and/or chilled water to meet concrete temperature specifications. During periods of cold weather, all concrete surfaces should be protected from freezing for at least the first 24 hours after placement to allow the concrete to attain a compressive strength of 500 psi. According to ACI 304.2R Section 4.2.1 "Placing Concrete by Pumping Methods ", the inside diameter of the hose should be a minimum of 3 times the maximum angular aggregate size of the concrete. (ASTM C33 allows 957LS to have up to 5% retained on the 1" sieve). It is recommended to minimize or eliminate the free fall of concrete to avoid loss of air content. Depending on boom configurations, alterations to the mix design may be required. We thank you for allowing us to submit these documents for your review. Please copy Redi -Mix with the approved submittal. The approved submittal allows Redi -Mix to review any notes, comments or exceptions made by the engineer or owner relating to the specification. Failure to notify us prior to first placement shall constitute acceptance of the submitted mix designs. Please order by mix number when scheduling concrete delivery. We request that you add Redi -Mix to the list of names receivintt copies of testine laboratory information for this proiect. ASTM C94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. This information is another tool for Redi -Mix to review and monitor the quality and performance of the concrete product delivered. If you have any other questions, please do not hesitate to call. Respectfully, Carol Dunn Technical Services Supervisor Date: 12/13/2011 Mix Number: 10311504 Strength: 3000 psi @ 28 days Description: 5.0 SK AIR NR Plant No.: 259 Customer: California Construction Project: Deforest Road - Coppell Usage: Sidewalks & Retaining Walls Saturated Surface Dry Weights Per Cubic Yard 4 1 &CON LL CRETE Re&Mix Concrete, L.P. a US Concrete Company The Technical Service Department 331 N. Main St Euless, TX 76039 Office: (817) 835-4187 Fax: (817) 835-4074 RedimixQC @usconcrete.com www.u&concrete.com Material Source Quantity Vol ASTM C150 Type 1 /11 Cement Ash Grove, Midlothian 470 lb 2.39 0 0.00 ASTM C33 No. 57 LS Hanson, Perch Hill 1850 lb 11.15 ASTM C33 Concrete Sand Redi -Mix, Chatfield 1370 lb 8.38 ASTM C494 B & D WR Retarder BASF 322N 2 -4 oz /cwt ASTM C260 Air Entrainment BASF AE90 1 -4 oz /cy 1.08 ASTM C94 Water 30 gal 4.00 Total Volume: 27.00 Specified Slump 4 +/- 1" Specified Air Percent: 4.5 +/- 1% Wet Unit Weight: 145.9 lb/ft-3 Design w/c ratio: 0.53 The use of an EF Technology mix design will reduce the amount of CO2 entering the atmosphere, thereby reducing potential global warming. EFn * ology- °Your Project, Our World" Notes: Please make sure that redimixgc @us- concrete.com is on the list to receive break reports. This mix has been designed to meet the requirements of this project based on the information sent to Redi -mix Concrete. It is the responsibility of the purchaser to determine whether this mix design meets project specifications and is appropriate for the anticipated environment conditions. The specified strength guarantee per ASTM C94 will not be effective unless field sampling has been done per ASTM C172 and ASTM C31 and the laboratory fully complies with ASTM C39 and ASTM C1077. In the event of limited material avaliability, substitution of a similar performing material may be required. All substituted materials will meet the appropriate ASTM requirements. In order to maintain the required mix volume, weights of individual materials may be varied to accommodate different material specific gravities. Material certifications for substituted materials are avaliable upon request. All Redi -Mix Concrete mix designs are proprietary and confidential. The information contained in this submittal is only intended for parties associated with this project to validate the mix design materials, properties and its performance. Use of this submittal for other purposes without permission or consent from Redi -Mix Concrete is strictly prohibited. MIX 10711504 ACI 318 STATISTICAL ANALYSIS DATES MAX 97 106 6.50 4460 5595 3445 5.3 MIN 57 46 1.75 1515 3470 475 2.0 NO. 29 28 29 30 30 30 29 MEANS 82 78 5.16 3300 4431 1132 4.0 SD 1 10.0 15.0 0.89 619 551 541 0.7 COV %j 12.2 19.2 17.2 18.7 12.4 47.8 18.7 DATE I CONC AIR 3D 7D 28D 7 -28 Air YY -MM -DD I TEMP TEMP SLMP STR. STR. STR. GAIN 1 61 2010 -12 -15 70 64 4.75 2670 4080 1410 5.3 2010 -12 -15 81 5.00 3435 5217 1782 4.0 2010 -12 -22 59 43 5.00 3630 5090 1460 3.5 2010 -12 -22 54 45 5.00 3250 4125 875 4.2 2010 -12 -22 57 45 5.00 3680 4740 1060 4.6 2011 -01 -04 1 64 55 4.75 3135 4700 1565 4.6 2011 -01 -19 1 61 61 4.25 4910 7265 2355 5.6 2011 -01 -19 1 63 43 5.00 3540 4875 1335 6.0 2011 -01 -19 1 61 54 5.00 4640 7250 2610 5.2 2011 -01 -26 1 46 36 5.00 4550 5460 910 4.8 2011 -02 -16 1 70 68 5.00 3685 5080 1395 4.9 2011 -02 -22 1 54 39 5.00 3810 6210 2400 3.8 2011 -02 -22 1 59 39 5.00 4160 5335 1175 3.9 2011 -02 -22 1 55 37 4.50 5200 6560 1360 3.5 2011 -02 -22 1 55 39 5.00 4890 6575 1685 3.7 2011 -02 -22 1 59 48 4.75 4140 5660 1520 4.0 2011 -02 -22 1 61 50 4.50 4200 5220 1020 4.3 2011 -02 -22 1 57 52 5.00 2360 5430 3070 4.1 2011 -02 -25 1 61 39 5.00 3535 4937 1402 4.6 2011 -02 -28 1 66 61 5.00 3560 4807 1247 3.5 2011 -03 -09 1 64 48 5.00 3040 4623 1583 4.0 2011 -03 -09 1 64 45 5.00 3190 4703 1513 4.0 2011 -03 -09 1 64 50 4.50 3670 5190 1520 4.7 2011 -03 -09 1 63 50 4.50 3020 4893 1873 4.5 2011 -03 -14 1 64 54 5.00 2960 4070 1110 3.5 2011 -03 -15 1 63 41 4.25 4140 5400 1260 3.5 2011 -03 -15 1 61 37 5.00 3965 5010 1045 3.6 2011 -03 -15 1 61 37 4.75 3950 5370 1420 3.5 2011 -03 -17 1 72 5.00 3240 4605 1365 4.2 2011 -03 -18 1 81 82 5.00 2770 3880 1110 3.8 Page 1 ASH GROVE CEMENT COMPANY AS H G ROVE 900 Gifco Road Post Office Box 520 Midlothian, Texas 76065 Type 1 /II Production Period: September 1 thru September 30, 2011 Date: 10/11/2011 The following information is based on average test data during the production period. The data is typical of cement shipped from the Midlothian, Texas plant. Individual shipments may vary. STANDARD REQUIREMENTS ASTM ClSO /ClSOM -09 OPTIONAL REQUIREMENTS ASTM C1SO/C150M -09, Tables 2 and 4 CHEMICAL PHYSICAL A.S.T.M. Test Spec. A.S.T.M. Test Item Method Limit Test Result Item Method Spec, Limit Test Result C + C ( %) 0314 A False set ( %) C451 A 79 Equivalent alkalies ( %) C114 0.60 0.42 Heat of hydration (k1 /kg) Equivalent alkalies 95% conf.limit- 0.44min., 0.60max 7 days C186 A&D 347 A = Not applicable. B = Limit not specified by purchaser, 28 Days A ,test results provided for information only. C = Test results for this period not available. D = Test results represent most recent values and is for information only. We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements of ASTM C150.09 and AASHTO M85. The above described cement, at the time of shipment, is approved under NSF /ANSI Standard 61 for Portland Ce t. Signature: Title: Chief Chemist Leo Snwlinski ....- :QUE1JNiE CARBAJAL NO 1ARY PUBLIC /sue STATE OF TEXAS ' +' Comm. Expires 02 24 buk �' CHEMICAL A.S.T.M. Test Spec. Item Method Limit Test Result Si0 %) C114 A 20.44 Al ( %) C114 6.0 max 5.00 Fe ( %) C114 6.0 max 3.22 CaO ( %) C114 A 64.98 M90 ( %) C114 6.0 max 0.82 S0 ( %) C114 3.0 max 2.76 Loss on ignition ( %) 0114 3.0 max 1.53 Na ( %) C114 A 0.09 K ( %) C114 A 0.50 Insoluble Residue ( %) 0114 0.75 max OA3 CO ( %) C114 A 1.08 Limestone ( %) per ASTM C114 5.0 max 3.0 Limestone ( %) per TXDOT Initial: Not more than 5.00% max. 3.0 Limestone ( %) perAHTO 5.00% max. 3.0 CaCO in limestone ( %) C114 70 min 82.61 Potential compounds ( %) C C114 A 60 C C114 A 13 C C214 8 max 8 C C114 A 10 C C114 A C +4.75 C C114 100 max 98 OPTIONAL REQUIREMENTS ASTM C1SO/C150M -09, Tables 2 and 4 CHEMICAL PHYSICAL A.S.T.M. Test Spec. A.S.T.M. Test Item Method Limit Test Result Item Method Spec, Limit Test Result C + C ( %) 0314 A False set ( %) C451 A 79 Equivalent alkalies ( %) C114 0.60 0.42 Heat of hydration (k1 /kg) Equivalent alkalies 95% conf.limit- 0.44min., 0.60max 7 days C186 A&D 347 A = Not applicable. B = Limit not specified by purchaser, 28 Days A ,test results provided for information only. C = Test results for this period not available. D = Test results represent most recent values and is for information only. We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements of ASTM C150.09 and AASHTO M85. The above described cement, at the time of shipment, is approved under NSF /ANSI Standard 61 for Portland Ce t. Signature: Title: Chief Chemist Leo Snwlinski ....- :QUE1JNiE CARBAJAL NO 1ARY PUBLIC /sue STATE OF TEXAS ' +' Comm. Expires 02 24 buk �' PHYSICAL A.S.T.M. Test Item Method Spec, Limit Test Result Air content of mortar (volume %) C185 12 max 8 Fineness (cm /g): Air permeability C204 2800 min 3994 Autodave expansion ( %) C351 0.80 max 0.03 Compressive strength (psi) 1 Day 0109 A 2057 3 Days C109 1740 min 3832 7 Days C109 2760 min 4985 28 Days C109 A Time of setting (minutes) (fit) Initial: Not less than C191 45 78 Initial: Not more than 375 OPTIONAL REQUIREMENTS ASTM C1SO/C150M -09, Tables 2 and 4 CHEMICAL PHYSICAL A.S.T.M. Test Spec. A.S.T.M. Test Item Method Limit Test Result Item Method Spec, Limit Test Result C + C ( %) 0314 A False set ( %) C451 A 79 Equivalent alkalies ( %) C114 0.60 0.42 Heat of hydration (k1 /kg) Equivalent alkalies 95% conf.limit- 0.44min., 0.60max 7 days C186 A&D 347 A = Not applicable. B = Limit not specified by purchaser, 28 Days A ,test results provided for information only. C = Test results for this period not available. D = Test results represent most recent values and is for information only. We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements of ASTM C150.09 and AASHTO M85. The above described cement, at the time of shipment, is approved under NSF /ANSI Standard 61 for Portland Ce t. Signature: Title: Chief Chemist Leo Snwlinski ....- :QUE1JNiE CARBAJAL NO 1ARY PUBLIC /sue STATE OF TEXAS ' +' Comm. Expires 02 24 buk �' ASH GROVE CEMENT COMPANY CA :H1 ROVE W 0 Type 1 /11 Production Period: September 1 thru September 30, 2011 900 Gifco Road Post Office Box 520 Midlothian, Texas 76065 Date: 10/11/2011 The following information is based on average test data during the production period. The data is typical of cement shipped from the Midlothian, Texas plant. Individual shipments may vary. Additional Data M85 Inorganic Processing Addition Data Type Limestone Amount( %) 2.98 SiO ( %) 8.49 Al ( %) 2.82 Fe %) 1.43 Ca0 ( %) 46.28 S0 3 ( %) 1.16 CO 2 N 36.23 Base Cement Phase Composition C 62 C 2 S 13 C 8 C.AF 10 JACQUELINE CARBAJAL NOTARY PUBLIC STATE OF TEXAS Comm. Expires 02- 24-2014 Signature: . retie: Chief Chemist S- n.U.ki j 1 4 CONCRETE Us 9 CONC TE REDI -MIX TECHNICAL SERVICES LABORATORY SIEVE ANALYSIS RESULTS Plant: Lewisville, Plant 259 Product: Fine Aggregate, ASTM C 33, Section 5.1 Date Sampled: 7/8/11 Date Tested: 7/20/11 Tested by: WCH Percentage SPEC'S Sieve mm %Ret %Pass 1112 38.10 0 100 - 1 25.40 0 100 314" 19.00 0 100 100 112" 12.70 0 100 100 3/8" 9.51 0 100 100 #4 4.76 2 98 95 -100 #8 2.38 11 89 80 -100 #16 1.19 28 72 50 -85 #30 0.60 48 52 25 -60 #50 0.30 80 20 5 -30 #100 0.15 96 4 0 -10 Pan 100 0 - #200 Decant 0.07 - 0 0 -3 FM 2.65 2.3 -3.1 ABS% 1.40 S.G. 2.62 Decant Method ASTM C117 Technical Services Manager mom mmm m o m Hanson HEIIDELBERGCEMENTGroup Product Quality Summary Report Period 10/24/2011 - 11/07/2011 Plant C777- BRIDGEPORT (PERCH -HILL) Product TX121 TX126 TX129 TX157 TX178 TX180 TX389 - ASTM #467 - ASTM #57 1" STATE - ASTM #67 Mfg Sand Cr. #6 - #20 Mfg. ASTM C -33 (1 -1/2" - # 4) (1" - # 4) Cr. GRADE 3 (3/4 "- #4) Cr. Lime Stone Sand Cr. Lime Sand Cr. Lime Cr. Lime Lime Stone 81.4 Lime Stone Stone Stone Stone 3/4" (19mm) Specification TXDOT 2 TXDOT 4/57 TXDOT 3 TXDOT 5/67 ASTM C -33 /467(421 -Crs) (421 -Crs) (421 -Crs) (421 -Crs) MFG SAND 2" (50mm) 100.0 1 1/2" (37.5mm) 100.0 100.0 100.0 1" (25mm) 81.4 95.9 95.2 100.0 3/4" (19mm) 55.7 78.7 76.9 94.7 1/2" (12.5mm) 38.1 39.8 39.8 51.1 3/8" (9.5mm) 23.7 26.4 22.8 26.9 100.0 100.0 100.0 #4 (4.75mm) 2.1 5.1 3.3 4.2 99.5 95.3 99.8 #8 (2.36mm) 1.9 1.3 1.1 73.4 57.3 86.2 #10 (2mm) 71.9 #16 (1.18mm) 41.2 24.0 60.3 #30 (0.6mm) 22.4 8.8 38.5 #40 (0.425mm) 24.7 #50 (0.3mm) 11.0 3.8 21.5 #80 (0.18mm) 10.7 #100 (0.15mm) 4.3 2.0 #200 (75um) 1.33 1.27 2.62 Pan 0.0 0.0 0.0 0.0 0.00 0.00 0.00 aggQC 11/07/2011 Lehigh Hanson Page: 1 of 1 mom MMM mom Hanson HEIDELBERGCEMENTGroup Basic Quality Statistical Summary Report Period 10/23/2011 - 11/06/2011 Plant C777- BRIDGEPORT (PERCH -HILL) Product TV 26-- ASTM #57 (1" -# 4) Cr. Lime Stone Specification TXDOT 4/57 (421 -Crs) Sieve/Test Tests Average St Dev Target Specification 4200 (75um) 2 0.56 0.085 aggQC 11/06/2011 Lehigh Hanson Page: 1 of 3 BAS The Chemical Company January 7, 2011 Certificate of Conformance Pozzolith 322N BASF Corporation* *(successor in interest to BASF Construction Chemicals, LLC, which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, inc., formerly known as Master Builders, Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga ) ss Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Sr. Technical Specialist for BASF Corporation in Cleveland, Ohio; and That Pozzolith 322N is manufactured by BASF Corporation; and That Pozzolith 322N, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00024 percent (2.4 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That Pozzolith 322N, depending upon the dosage used, meets the requirements for a Type A, Water - Reducing, Type B, Retarding, and Type D, Water- Reducing and Retarding Admixture specified in ASTM C 494, Corps of Engineers' CRD -C 87 and AASHTO M194 the Standard Specifications for Chemical Admixtures for Concrete. Richard Hubbard III BASF Corporation - Admixture Systems Subscribed and sworn to before me the 7th,4ay of January, 2091 Charlene R. Mandat Resident of Summit County Notary Public, State of Ohio My Commission Expires November 4, 2011 Master Builders = : T j j The Chemical Company January 7, 2011 Certificate of Conformance Pozzolith 30OR BASF Construction Chemicals * Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC, which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga ) ss Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Technical Specialist for BASF Corporation in Cleveland, Ohio; and That Pozzolith 30OR is manufactured by BASF Corporation — Admixture Systems; and That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 300R; and That Pozzolith 300R, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.0002 percent (2.0 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That Pozzolith 30OR meets the requirements for a Type B, Retarding, and Type D, Water- Reducing and Retarding Admixture specified in ASTM C 494, Corps of Engineers' CRD -C 87, and AASHTO M194, the Standard Specifications for Chemical Admixtures for Concrete. Richard Hubbard III BASF Corporation — Admixture Systems Subscribed and sworn to before me the,7fh day of January, 20 7 Charlene R. Manda� Resident of Summit County Notary Public, State of Ohio My Commission Expires November 4, 2011 Master Builders BASF The Chemical Company January 7, 2011 Certificate of Conformance PolyHeed 1020 BASF Corporation* *(successor in interest to BASF Construction Chemicals, LLC, which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga )Ss Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Sr. Technical Specialist for BASF Corporation in Cleveland, Ohio; and That PolyHeed 1020 is manufactured by BASF Corporation — Admixture Systems; and That no calcium chloride or chloride based ingredient is used in the manufacture of PolyHeed 1020; and That PolyHeed 1020, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00014 percent (1.4 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That, depending on the dosage used, PolyHeed 1020 meets the requirements for a Type A, Water - Reducing, and Type F, Water- Reducing, High Range Admixture specified in ASTM C 494, Corps of Engineers' CRD -C 87 and AASHTO M194, the Standard Specifications for Chemical Admixtures for Concrete. Richard Hubbard III BASF Corporation — Admixture Systems Subscribed and sworn to before me the,7ffi'day of January, 2011 Z Charlene R. Mandat f Resident of Summit County Notary Public, State of Ohio My Commission Expires November 4, 2011 Master Builders r BASF The Chemical Company January 7, 2011 Certificate of Conformance MB AE 90 BASF Corporation* Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC, which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.) TO WHOM IT MAY CONCERN: State of Ohio ) County of Cuyahoga )Ss Before me, a Notary Public, in and for the aforesaid State and County, personally appeared Richard Hubbard III, who being duly sworn, deposes and says: That he is a Sr. Technical Specialist for BASF Corporation in Cleveland, Ohio; and That MB AE 90 is manufactured by BASF Corporation — Admixture Systems; and That MB AE 90 is Master Builders air - entraining admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of MB AE 90; and That MB AE 90, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.000068 percent (0.68 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That MB AE 90 meets the requirements of ASTM C 260, Corps of Engineers CRD -C 13, and AASHTO M154, the Standard Specifications for Air - Entraining Admixtures for Concrete. Richard Hubbard III BASF Corporation — Admixture Systems Subscribed and sworn to before me the Ah day of January 2011 Charlene R. Mandat' Resident of Summit County Notary Public, State of Ohio My Commission Expires November 4, 2011 Master Builders