Loading...
NL Cypress-CS111123 (1/30/2012) George Marshall - Re: Saintsbury Water and WW Connections to CoppellPage 1 From: <brad.moss@kimley-horn.com> To: <gmarshall@coppelltx.gov> CC: <marty.paris@kimley-horn.com> Date: 11/23/2011 11:50 AM Subject: Re: Saintsbury Water and WW Connections to Coppell Thanks George. Sent from my iPhone On Nov 23, 2011, at 11:41 AM, "George Marshall" <gmarshall@coppelltx.gov> wrote: > Marty, > > Please see the attached letter. > > Thank You, George > > > George Marshall, PE > City of Coppell > Engineering > 972-304-3562 >>>> <marty.paris@kimley-horn.com> 11/15/2011 4:11 PM >>> > George, > We have addressed your comments on the Cypress Waters – Saintsbury Street - Water & Wastewater Tie-in Plans as described below and shown on the attached drawings. > Water > > 1. Delineate City of Coppell maintenance vs. City of Dallas. > > a. The delineation is shown and labeled in the plan view on Sheet C-101. > > 2. All tie-ins, borings, etc. shall be per City of Coppell Standards. > > a. Note #1 was added to the Sheet C-101. > > 3. Provide a compound meter instead of a transit time flow meter. Remove sump pump & power service. > > a. The transit time flow meter was removed and replaced with a compound meter as shown on Sheet C-101 and C-111. > > 4. Provide backflow prevention device on the Dallas side of the meter. > > a. A double check valve assembly was added as shown on Sheet C-101 and C-111. > > 5. All water line fittings, bends, valves, etc. shall have mega-lug type joint connections. > > a. Note #2 was added to Sheet C-101. > > 6. All bends and tees shall have thrust blocks provided. > > a. Note #3 was added to Sheet C-101. > > 7. Detail 1 – remove 10” segment of pipe between tee, valve and bend & provide flanged connection. (1/30/2012) George Marshall - Re: Saintsbury Water and WW Connections to CoppellPage 2 > > a. Detail 1 on Sheet C-101 was revised. > > 8. No compact fittings. > > a. Note #4 was added to Sheet C-101. > > 9. Use long sleeve dresser coupling to cut in 12”x12” tee (both sides). > > a. Note #5 was added to Sheet C-101. > > 10. Use City of Coppell standard on 4190 for lid on meter vault. > > a. The City of Coppell Standard Detail 4190 is reference on the detail Sheet C-111. > Wastewater > > 11. Delineate City of Coppell maintenance vs. City of Dallas. > > a. Note #2 was added to Sheet C-02. > > 12. Check proposed size of pipe in call at Sta: 1+98.05 (15” vs. 16”) > > a. The size label was changed to 15” on Sheet C-02. > > 13. FYI, The City of Coppell has not seen nor approved wastewater plans for the line being tied into by this construction. Additional comments or changes may be necessary. > Please let us know if you have any questions or need additional information. Thank you. > Marty S. Paris, PE > Kimley-Horn and Associates, Inc. > 12700 Park Central Drive, Suite 1800 > Dallas, Texas 75251 > 972-770-1300 (main) 972-239-3820 (fax) > 972-776-1732 (direct) > marty.paris@kimley-horn.com<mailto:marty.paris@kimley-horn.com> > > From: George Marshall [mailto:gmarshall@coppelltx.gov] > Sent: Friday, November 04, 2011 8:38 AM > To: Moss, Brad > Subject: Saintsbury > > Brad, > > Please see attached comment letter on the Wastewater & water tie-in at Belt Line. The marked up plans are here for you to pick up. > > Thank You, George > > > George Marshall, PE > City of Coppell > Engineering > 972-304-3562 > <Letter & Permit.pdf>