Loading...
Red Hawk-LR120123REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Creststone GroupDATE: 01/23/12 Coppell, Texas PROJECT:OUR REPORT NO.:110991-55 Red Hawk Residential Coppell, Texas TEST DATA:TECHNICIAN:Daniel Montenegro MAXIMUM LABIN PLACEIN PLACE OPTIMUM TESTSOIL ID ELEV. PERCENT DATE COMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 69201/23/12FG521.598.321.7981003-A 69301/23/12FG521.598.323.497993-A 69401/23/12FG521.598.322.895973-A 69501/23/12FG521.598.322.9981003-A 69601/23/12FG521.598.323.197983-A 69701/23/12FG422.097.522.296983-A 69801/23/12FG422.097.524.595973-A TEST LOCATION:Paving 692Blackburn Drive Southbound at Station 1+00, Centerline 1/4 Left 693Blackburn Drive Northbound at Station 1+00, Centerline 1/4 Right 694Blackburn Drive at Station 2+50, Centerline 695Oxford Place at Station 3+00, Centerline 696Oxford Place at Station 6+00, Centerline 1/4 Left 697Oxford Place at Station 9+00, Centerline 1/4 Right 698Washington Drive at Station 11+00, Centerline 1/4 Left 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. REPORT OF FIELD COMPACTION TESTS 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Creststone GroupDATE: 01/23/12 Coppell, Texas PROJECT:Red Hawk ResidentialOUR REPORT NO.:110991-55A Coppell, Texas TEST DATA:TECHNICIAN:Daniel Montenegro OPTIMUMMAXIMUM LABIN PLACEIN PLACE TESTSOIL ID ELEV. PERCENT DATECOMMENT* MOISTUREDRY DENSITYMOISTUREDRY DENSITY NO.NUMBER COMPACTION DEPTH %PCF%PCF 69901/23/12FG422.097.524.796983-A 70001/23/12FG521.598.323.996983-A 70101/23/12FG521.598.324.6981003-A 70201/23/12FG521.598.322.095973-A 70301/23/12FG422.097.522.594973-A 70401/23/12FG422.097.523.9981013-A 70501/23/12FG422.097.523.4971003-A TEST LOCATION:Paving 699Devon Drive at Station 14+00, Centerline 1/4 Right 700Devon Drive at Station 17+00, Centerline 701Devon Drive at Station 20+00, Centerline 1/4 Left 702Washington Court at Station 1+50, Centerline 1/4 Right 70315' Alley at Station 0+50, Centerline 1/4 Left 70415' Alley at Station 3+50, Centerline 70515' Alley at Station 6+50, Centerline 1/4 Right 1. FILL*A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADEB. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZEDC. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONSRespectfully Submitted, 4. CEMENT TREATEDD. RETEST Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.