ST0001-LR960327 (2)TEXAS INDUSTRIES, INC. 1341 W. MOCKINGBIRD LANE • DALLAS, TEXAS 75 24 7 -691 3 • (214) 647 -6700 March 27, 1996 Austin Bridge & Road 11143 Goodnight Lane Dallas, Tx 75229 Attention Mr. Gary Atwood RE: Creek View Drive 8272 Gentlemen: The attached concrete mix designs utilizing the appropriate ASTM C -33 or ASTM C -330 aggregate are proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix designs, when ordered by specified design identity, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of ACI Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94, Section 14 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix designs prior to their use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix designs are ordered please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely, TEXAS INDUSTRIES, INC. 4X4"" a- ae4 - Michael A. Caldarone, P.E. Manager - Q.A. /Q.C. TEXAS INDUSTRIES, INC. CONCRETE DESIGN EVALUATION Date: 03/27/96 ** Statistics Compiled From Independent Laboratory Test Specimens ** Page: 1 Mix No. E8272 Strength 3000 psi @ 28 Days 28 Day Test Data Test Plant Temperature Placement Percent - --- --- 28 Day - - - - - -- Cum Moving No. Date No. Amb Con Slump of Air PSI 1 PSI 2 PSI Avg Avg Avg of 3 Range 1 10/17/95 25 60 78 4.5 N/A 4490 4340 4415 4415 4415 150 2 10/17/95 25 62 78 5.0 N/A 4130 4160 4145 4280 4280 30 3 10/17/95 25 65 81 4.7 N/A 4030 3920 3975 4178 4178 110 4 10/17/95 25 75 83 4.5 N/A 4100 3790 3945 4120 4022 310 5 10/20/95 25 52 55 4.5 N/A 4790 4590 4690 4234 4203 200 6 10/20/95 25 57 60 4.0 N/A 4650 4540 4595 4294 4410 110 7 10/20/95 25 59 60 5.0 N/A 3270 3550 3410 4168 4232 280 8 10/20/95 25 48 50 4.5 N/A 4390 4280 4335 4189 4113 110 9 10/23/95 43 N/A 78 4.2 5.3 4050 3860 3955 4163 3900 190 10 10/23/95 43 N/A 81 4.0 N/A 4080 4310 4195 4166 4162 230 11 10/24/95 43 N/A 72 5.5 5.1 3620 3600 3610 4115 3920 20 12 10/24/95 43 N/A 75 3.0 4.7 4220 4280 4250 4127 4018 60 13 10/25/95 43 N/A 78 5.0 5.0 3590 3860 3725 4096 3862 270 14 10/25/95 43 N/A 71 3.7 5.2 3720 3950 3835 4077 3937 230 15 10/26/95 43 N/A 83 5.0 N/A 3710 3560 3635 4048 3732 150 16 10/27/95 43 N/A 81 5.0 N/A 3870 3940 3905 4039 3792 70 17 11/02/95 43 N/A 71 4.2 5.8 5010 5100 5055 4099 4198 90 18 11/03/95 43 N/A 67 4.2 N/A 5250 5340 5295 4165 4752 90 19 11/07/95 25 63 73 4.2 N/A 4180 4150 4165 4165 4838 30 20 11/09/95 43 N/A 71 3.5 N/A 4970 5250 5110 4212 4857 280 21 11/09/95 43 N/A 70 3.7 4.5 5080 4980 5030 4251 4768 100 22 11/09/95 43 N/A 70 3.5 4.7 5310 5200 5255 4297 5132 110 23 11/10/95 43 N/A 79 5.0 4.4 3920 3970 3945 4282 4743 50 24 11/10/95 25 70 76 5.0 N/A 4030 3900 3965 4268 4388 130 25 11/10/95 25 65 74 4.2 N/A 4330 4400 4365 4272 4092 70 26 11/10/95 25 66 75 5.0 N/A 4060 3960 4010 4262 4113 100 27 11/20/95 43 N/A 75 3.5 4.5 3560 3670 3615 4238 3997 110 28 11/21/95 43 N/A 74 6.0 6.8 4080 4090 4085 4233 3903 10 29 11/28/95 43 N/A 59 5.0 4.7 4770 4800 4785 4252 4162 30 30 11/30/95 43 N/A 59 5.7 5.9 4080 4150 4115 4247 4328 70 * ** Averages * ** 62 72 4.5 5.1 COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix No. E8272 Strength 3000 psi @ 28 Days Paragraph 5.5 of ACI 318 -89 provides that as data becomes available during construction, the amount by which (f' must exceed the specified value of (f' may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318 -89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations f' = f' + 1.34(SD) = 3000 + 1.34(00517) 3693 f' = f' + 2.33(SD) - 500 = 3000 + 2.33(00517) - 500 = 3705 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Numberof Tests .......................... 30 Maximum Value ............................ 5295 psi Minimum Value ............................ 3410 psi Range......... ......................... 1885 psi Average Strength ......................... 4247 psi Standard Deviation..... ................ 517 psi Required Average Strength to satisfy minimum probability conditions of ACI 318 -89 Section 5.3.2.1 ............... 3705 psi Design excess beyond code requirements.. 542 psi MIX # 8272 5.00SK ADMIX /AEA 1 "CS 3000 PSI @ 28 Days SLIP FORM PAVING Maximum Coarse Aggregate Size: ASTM C 33 1"- #4 Crushed Stone Maximum Water /Cement Ratio: 6.00 gal /sk .531 lb /lb Minimum Cement Content per Cubic Yard: 5.00 sacks Maximum Placement Slump: 3.0 inches Admixture ASTM C -494: Type A or D Air Entraining Agent ASTM C -260: 3% - 6% MATERIAL QUANTITIES PER 1 CUBIC YARD AT S.S.D. 470 lbs. or 5.00 sacks ASTM C 150 Type I Cement 1840 lbs. ASTM C 33 1"- #4 Crushed Stone 1396 lbs. ASTM C 33 Concrete Sand 250 lbs. or 30.0 gallons of Water 2.0 to 4.0 oz /cwt of ASTM C -494 Type A Specified Air Content: 3% - 6% Placement Slump: 2.0 + or - 1 inches PUMPING RECOMMENDATIONS 1. 5 minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Slumps and test cylinders should be taken @ discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and /or layout configuration changes, additional cement may be required to assure strength and pumpability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air when loss occurs due to pressure differentials created as a result of boom configuration or free fall discharge of concrete from end of hose. We are enclosing all available back up data for the above referenced mix design. If the strength information is not available or is not sufficient, conformation cylinders may have to be made by your testing laboratory. Y tXi TEXAS INDUSTRIES, INC. ® CEMENT DIVISION, 245 Ward Road Midlothian, Texas 76065 SPECIFICATIONS Portland Cement Type 1 /II (Low Alkali) A.S.T.M. C150 -95 A.A.S.H.T.O. M 85 -911 Bin Number Car Number Date of Sampling January 1996 Monthly Average SPECIFICATIONS TEST AST M CH1= IV(ICAL F3EQUIFEMEi�f$ AASHTO RESULTS Silica Oxide, Mtnimum Percent Alumina Oxide, Maximum Percent 20'0 20'0 20.3 Iron Oxide, Maximum Percent 6.0 6.0 4.5 Magnesia Oxide, Maximum Percent 6.0 6.0 3.7 S03 (C3A less than 8 %), Maximum Percent 6.0 6.0 1.2 Loss on Ignition, Maximum Percent 3.5 Insoluble residue, Maximum Percent 3.0 3.0 1.0 Tricalcium Aluminate, Maximum Percent 0.75 0,75 0 21 '> C3PT)flNAL flHEMICAL R1= QUltl= 8 111[1 =IVT$ 8 6 Total Alkalies, Max % (Na20 equiv.) 0.60 I�HYSf At , EQU1 EN'IS 0.60 0-Y8 Specific surface, Minimum (M ^2 /Kg) 280 Blaine Maximum (M ^2 /Kg) 280 Gillmore, Initial Set, Minimum (Minutes) 400 363 Gillmore, Final Set, Maximum (Minutes) 60 60 164 Vicat, Minimum (Minutes) 600 45 600 289 Initial Set Maximum (Minutes) 45 375 Air Content, Volume Maximum Percent 101 sio Autoclave Expann, Maximum Percent 12 1 2 12 5 3 Day Minimum Compressive Strength, PSI 0.80 0'80 0.01 7 Day Minimum Compressive Strength, PSI 1800 1800 3471 STATE OF TEXAS 2800 2800 4489 ELLIS COUNTY J.R. Owens , being duly sworn deposes and says; that he is Chief Chemist Texas Industries, Inc., Cement Division, who prepared the above report that the same true and correct. of of tests and Subscribed�nd sworn to before me this 12th day of February, 1996. Notary Public emist "See ASTM C150 Table 1, Footnote B. 4 o�� ar °ti K. C. COKER Notary Public STATE OF TEXAS `orI M; Comm. Exp. 10/22/98 GRACE April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: Construction Products Division W. R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223 -8353 This is to certify that DARATARD -17, a water- reducing set - retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.- Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C -494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD -17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. xc do� � ly, Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. Tom C. Henson District Manager oLary Pgqimc DOUIYJ. WACHEL Notary Public, State of Texas My Commission Expires 10 -20 -97 We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. GRACE April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: Construction Products Division W. R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223 -8353 This is to certify that WRDA with HYCOL, a water - reducing admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.- Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C -494, Type A (AASHTO M194, Type A). No chlorides or halogens are added to WRDA with HYCOL as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. Sin erely, Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. Tom C. Henson District Manager Notary P c Y • WACHEL Notary ublic, State of Texas My Commisslon moires 10 -20 -97 We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. GRACE April 3, 1995 Texas Industries, Inc. 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: Construction Products Division W. R. Grace & Co.- Conn. P.O. Box 2585 Houston, TX 77252 (713) 223 -8353 This is to certify that Daravair 1000, an air - entraining admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.- Conn., is formulated to comply with Specification for Air - Entraining Admixtures for Concrete, ASTM Designation: C260 (AASHTO M154). Daravair 1000 does not contain calcium chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The foregoing is in addition to and not in substitution for our standard Conditions of Sales printed on the reverse side hereof. Xely, C Subscribed and sworn to, before me, this 3rd day of April, 1995 A.D. Tom C. Henson District Manager ry Notary Public,'State of Texas My Commission Expires 10 -20 -97 We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 02/07/96 #ALL Tests Size #: 33 Project: * * * ** ALL JOBS * * * ** Production Facility: PARADISE Grading Designation: ASTM C -33 FINE AGG Sample Location: M.C. 6.1% Sampled By: -��. Decant 1.03% ` S.E. 85.76 Tested By: 100% of 166 tests: Size 33 Plant: PARADISE Job: * * * ** ALL JOBS * * * **