Loading...
ST0004-LR010605TERRAMAR GEOTFCHNICAL, ENVIRONMENTAL AND MATERIALS ENMNEERS DA ' FORT WORTH HOUSTON AUSTIN LC 7EW 11050 Ables Ln., Dallas, Texas 75229 phone: (972) 488 -8800 fax :(972) 488 -8080 Concrete Compression Test Report Client: The City of Coppell Report Distribution: (1) The City of Coppell Project: Freeport Parkway Pavement Repair TMI Report No.: DC01- 066 -005 Report Date: 06/05/2001 Strength Slump Air Content Concrete Temperature Ambient Temperature 4000 psi @ 28 Days 5 in max 3 % min 6 %max n/a n/a Placement Date Sampled By Weather Supplier /Mix Air Content Method 05/29/2001 Mohammed A. Kashem Clear Hanson /9636 ASTM C -231 -B Ticket Number: 684485 Time Batched: 12:20 PM Slump: 6 in* Air Content: 4.3% Concrete Temperature: 82° F Ambient Temperature: 80° F Placement Location: Street repari at Freeport Parkway Sample Location: At hole #1 at South end An asterisk ( *) appears next to field data which does NOT meet specifications. Time Sampled: 1:25 PM Unit Weight: n/a Yardage (c.y.): 70 of 70 Set # Cylinder # Tes Da Age Max Load Area Stren th (d ays) ( I b s. force) ( 1 05290101 06/05/2001 (psi 7 90480 28.27 1 05290102 06/26/2001 3200 28 1 05290103 06/26/2001 28 1 05290104 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by TMI are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 TERRA -MAR, INC. Fracture Type unbonded cap The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of TMI. OISSD Page 1 of 1