ST1002-LR120226CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 94111246.0043
Service Date: 02/16/12 8901 Carpenter Frwy. Suite 100
Report Date: 02/26/12 Dallas, TX 75247
Task: 214 - 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Old Town Coppell & Bethel Road
Attn: Rick O'Dell #ST10 -02
Engineering Dept Between Coppell Rd & Freeport
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94111246
Material Information Sample Information
Specified Strength: 4,200 psi @ 28 days
Mix ID: 1701
Supplier: Lattimore
Batch Time: 1439 Plant: 955
Truck No.: 5022 Ticket No.: 64317192
Field Test Data
Test
Slump (in):
Air Content ( %):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Yield (Cu. Yds.):
Sample Date:
Sampled By:
Weather Conditions:
Accumulative Yards:
Placement Method:
Water Added Before (gal):
Water Added After (gal):
Sample Location:
Placement Location:
02/16/12 Sample Time: 1545
Michael Flute
Cloudy
10 Batch Size (cy): 10
Direct Discharge
10
0
Line D, Sta. 0 +26, bottom inlet
Inlets, Line A at Sta. 9 +25; Line C,
Sta. 8 +22, north and south; Line D,
Sta. 0 +26, bottom inlet
Result Specification
41/2 3 -5
3.4 3 -6
65
50
148.7
Laboratory Test Data
Age at
Maximum
Compressive
Set
Specimen Diameter
Area
Date
Date
Test
Load
Strength
Fracture
No.
ID
(in)
(sq in)
Received
Tested
(days)
(lbs)
(psi)
Type
1
1
6.00
28.27
02/17/12
02/23/12
7
158,140
5,590
2
1
2
6.00
28.27
02/17/12
02/23/12
7
146,740
5,190
2
Average (7 days)
5,390
1
3
6.00
28.27
02/17/12
03/15/12
28
1
4
6.00
28.27
02/17/12
03/15/12
28
Comments
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Michael Flute
Reported To:
Contractor:
Report Distribution:
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By:
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E.
(1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM 0231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CROOO I, 8- 27 -11, Rev.5 Page 1 of 1
CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon
Report Number: 94111246.0045
Service Date: 02/17/12 8901 Carpenter Frwy. Suite 100
Report Date: 02/26/12 Dallas, TX 75247
Task: 214 - 630 -1010 Reg No: F -3272
Client Project
City of Coppell TX Old Town Coppell & Bethel Road
Attn: Rick O'Dell #ST10 -02
Engineering Dept Between Coppell Rd & Freeport
PO Box 9478 Coppell, TX
Coppell, TX 75019 Project Number: 94111246
Material Information Sample Information
Specified Strength: 4,200 psi @ 28 days
Mix ID: 1701
Supplier: Lattimore
Batch Time: 1345 Plant: 1952
Truck No.: 9141 Ticket No.: 62926690
Field Test Data
Test
Slump (in):
Air Content ( %):
Concrete Temp. (F):
Ambient Temp. (F):
Plastic Unit Wt. (pcf):
Yield (Cu. Yds.):
Result Specification
31/2 3 -5
4.9 3-6
67
60
144.8
Laboratory Test Data
Sample Date:
02/17/12 Sample Time: 1435
Sampled By:
Albert Garcia
Weather Conditions:
Cloudy
Accumulative Yards:
10 Batch Size (cy): 10
Placement Method:
Direct Discharge
Water Added Before (gal):
0
Water Added After (gal):
0
Sample Location:
Sta. 0 +26, Line D
Placement Location:
Inlet walls
Set
Specimen
Diameter
Area
Date
Date
No.
ID
(in)
(sq in)
Received
Tested
1
1
6.00
28.27
02/18/12
02/24/12
1
2
6.00
28.27
02/18/12
02/24/12
1
3
6.00
28.27
02/18/12
03/16/12
1
4
6.00
28.27
02/18/12
03/16/12
Age at Maximum Compressive
Test
Load
Strength Fracture
(days)
(lbs)
(psi) Type
7
141,710
5,010 2
7
142,500
5,040 2
Average (7 days)
5,030
28
28
Comments:
Samples Made By: Terracon
Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength
samples.
Terracon Rep.: Albert Garcia
Reported To:
Contractor:
Report Distribution:
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By:
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E.
(1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Senior Project Manager
Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM 0231, ASTM C1064, ASTM C1231
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the
actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
CROOO I, 8- 27 -11, Rev.5 Page 1 of 1
SAMPLE PICK -UP REPORT
Report Number: 94111246.0047
Irerracon
Service Date: 02/18/12
8901 Carpenter Frwy. Suite 100
Report Date: 02/26/12
Dallas, TX 75247
214 - 630 -1010 Reg No:F -3272
Client
Project
City of Coppell TX
Old Town Coppell & Bethel Road
Attn: Rick O'Dell
#ST10 -02
Engineering Dept
Between Coppell Rd & Freeport
PO Box 9478
Coppell, TX
Coppell, TX 75019
Project Number: 94111246
TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 4
Report No.: 94111246.0045
No. of Cylinders: 4
Services: Concrete cylinder pickup.
Terracon Rep.: Julio R. Perez
Reported To:
Contractor:
Report Distribution:
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed
(1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed
Reviewed By: "�Zz
Eric J. Cleveland, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
BC0001, 10- 25 -10, Rev.9 Page 1 of 1 dgr
SAMPLE PICK -UP REPORT
Report Number: 94111246.0056
Irerracon
Service Date: 02/21/12
8901 Carpenter Frwy. Suite 100
Report Date: 02/26/12
Dallas, TX 75247
214 - 630 -1010 Reg No:F -3272
Client
Project
City of Coppell TX
Old Town Coppell & Bethel Road
Attn: Rick O'Dell
#ST10 -02
Engineering Dept
Between Coppell Rd & Freeport
PO Box 9478
Coppell, TX
Coppell, TX 75019
Project Number: 94111246
TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 4
Report No.: 94111246.0050
No. of Cylinders: 4
Services: Concrete cylinder pickup.
Terracon Rep.: Christopher Amoah
Reported To:
Contractor:
Report Distribution:
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed
(1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By:
(1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Eric J. Cleveland, P.E.
Senior Project Manager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to
the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials.
BC0001, 10- 25 -10, Rev.9 Page 1 of 1 dgr