ST1002-LR120226CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94111246.0043 Service Date: 02/16/12 8901 Carpenter Frwy. Suite 100 Report Date: 02/26/12 Dallas, TX 75247 Task: 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Old Town Coppell & Bethel Road Attn: Rick O'Dell #ST10 -02 Engineering Dept Between Coppell Rd & Freeport PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94111246 Material Information Sample Information Specified Strength: 4,200 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1439 Plant: 955 Truck No.: 5022 Ticket No.: 64317192 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Date: Sampled By: Weather Conditions: Accumulative Yards: Placement Method: Water Added Before (gal): Water Added After (gal): Sample Location: Placement Location: 02/16/12 Sample Time: 1545 Michael Flute Cloudy 10 Batch Size (cy): 10 Direct Discharge 10 0 Line D, Sta. 0 +26, bottom inlet Inlets, Line A at Sta. 9 +25; Line C, Sta. 8 +22, north and south; Line D, Sta. 0 +26, bottom inlet Result Specification 41/2 3 -5 3.4 3 -6 65 50 148.7 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (lbs) (psi) Type 1 1 6.00 28.27 02/17/12 02/23/12 7 158,140 5,590 2 1 2 6.00 28.27 02/17/12 02/23/12 7 146,740 5,190 2 Average (7 days) 5,390 1 3 6.00 28.27 02/17/12 03/15/12 28 1 4 6.00 28.27 02/17/12 03/15/12 28 Comments Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Michael Flute Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E. (1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM 0231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO I, 8- 27 -11, Rev.5 Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Irerracon Report Number: 94111246.0045 Service Date: 02/17/12 8901 Carpenter Frwy. Suite 100 Report Date: 02/26/12 Dallas, TX 75247 Task: 214 - 630 -1010 Reg No: F -3272 Client Project City of Coppell TX Old Town Coppell & Bethel Road Attn: Rick O'Dell #ST10 -02 Engineering Dept Between Coppell Rd & Freeport PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94111246 Material Information Sample Information Specified Strength: 4,200 psi @ 28 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1345 Plant: 1952 Truck No.: 9141 Ticket No.: 62926690 Field Test Data Test Slump (in): Air Content ( %): Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Result Specification 31/2 3 -5 4.9 3-6 67 60 144.8 Laboratory Test Data Sample Date: 02/17/12 Sample Time: 1435 Sampled By: Albert Garcia Weather Conditions: Cloudy Accumulative Yards: 10 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Sta. 0 +26, Line D Placement Location: Inlet walls Set Specimen Diameter Area Date Date No. ID (in) (sq in) Received Tested 1 1 6.00 28.27 02/18/12 02/24/12 1 2 6.00 28.27 02/18/12 02/24/12 1 3 6.00 28.27 02/18/12 03/16/12 1 4 6.00 28.27 02/18/12 03/16/12 Age at Maximum Compressive Test Load Strength Fracture (days) (lbs) (psi) Type 7 141,710 5,010 2 7 142,500 5,040 2 Average (7 days) 5,030 28 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep.: Albert Garcia Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E. (1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM 0231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO I, 8- 27 -11, Rev.5 Page 1 of 1 SAMPLE PICK -UP REPORT Report Number: 94111246.0047 Irerracon Service Date: 02/18/12 8901 Carpenter Frwy. Suite 100 Report Date: 02/26/12 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Old Town Coppell & Bethel Road Attn: Rick O'Dell #ST10 -02 Engineering Dept Between Coppell Rd & Freeport PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94111246 TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 4 Report No.: 94111246.0045 No. of Cylinders: 4 Services: Concrete cylinder pickup. Terracon Rep.: Julio R. Perez Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Reviewed By: "�Zz Eric J. Cleveland, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10- 25 -10, Rev.9 Page 1 of 1 dgr SAMPLE PICK -UP REPORT Report Number: 94111246.0056 Irerracon Service Date: 02/21/12 8901 Carpenter Frwy. Suite 100 Report Date: 02/26/12 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Old Town Coppell & Bethel Road Attn: Rick O'Dell #ST10 -02 Engineering Dept Between Coppell Rd & Freeport PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94111246 TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 4 Report No.: 94111246.0050 No. of Cylinders: 4 Services: Concrete cylinder pickup. Terracon Rep.: Christopher Amoah Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Eric J. Cleveland, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10- 25 -10, Rev.9 Page 1 of 1 dgr