Report of Concrete Compressive Strength Test
Client: JR Rose Development Companies Report No.: 406409
2209 Cameron Crossing Project No.: 1116815
Grapevine, TX 76051
Date of Service: 02/06/2012
Report Date: 02/14/2012
Project: Willow Park Townhomes -
Coppell, Texas
Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring
samples back to the laboratory for curing and testing in accordance with applicable standards.
PROJECT DATA
Contractor: Mix Design I.D.: D10000001083 Measured
Concrete Supplier: Southern Star Placement Date: 02/06/2012 Slump
Plant: 110 Weather Conditions: Partly cloudy (inches)
Specification Requirements Time Sampled: 04:10pm Batch time: 03:30pm 4.0
Strength: 4,000 psi @ 28 days Temperature - Air: 55 °F Concrete: 72 °F
Slump (in.): 3" - 5" Truck No: 1063 Ticket No: 1974454
Air ( %): 3% - 5% Air Content: 3.0% Unit Weight (pcf): NA
Test Method: ASTM C -172 Overall Placement Location:
ASTM C -31 (except 10.1.2) Storm drain tops at Rembrant Court and DaVinci Court
ASTM C -143
ASTM C -231
ASTM C -1064
ASTM C -138 Sample Location:
ASTM C -1231 Storm drain at Rembrant Court
REPORT OF TESTS
Concrete Compressive Cylinder 6" x 12"
Cylinder Maximum Compressive
Marked Date Age Diameter Area Load 7_,q th Fracture
Set No. Tested (days) (in) (in') (Ibs) i) Type
1 1 02/13/2012 7 6.00 28.27 122,890 350 Type 4
1 2 03/05/2012 28
1 3 03/05/2012 28
IxIN HN N H '11„i 1 1/792
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 e7/ E .„
/ 67V.....---- --
Technician: Ramon Hernandez Started: 03:30pm Finished: 05:45prn_ ) Rone Engineering
Report Distribution: ,,
•
Orig: JR Rose Development Companies (Grapevine, TX) 111111111
Attn: Mr. Jason Rose (1 -ec copy)
1 -ec Rone Project Manager Attn: Mr. Jason Creasy AET
1 -ec City of Coppell Attn: Mr. Mike Garza Jason Creasy, AET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(TM /JC)
Page 1 of 1