Loading...
Red Hawk-LR120305 Alpha Testing, Inc. 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, TX 75229 (972)620 -8911 Report TBPE Firm No. 813 Tested For: CRESTSTONE GROUP Date Issued: 03/05/2012 ATTN: DAVID HAYES Report #: 110991-62 HI NY E. HY 121, #120 COPPELL, TX 75019 PM: YONAS TANGA Fax Number (214) 488 -525 40 3p Project 1 - c • HAWK RESID . L ' WC OF B SCHOOL RD. AND DENTON A` FIELD DATA Placement Location: PAVING Sample Location: DEVON DR.@ STATION 16 +00 3 // Date Placed: 2/6/2012 Plant umber: 995 Time Placed: 7:30 AM Delivery Ticket No 64316616 Slump (ASTM C -143): 2.0 Mix ID: 1551 Air Content: 4.0 (ASTM C -173) Made By: ALPHA Air Temperature: 35 Cured Specification: AS '� 31'°""`"°' Specimen Temperature: 57 Date Received: 2/7/2012 ^ Field Data Submitted By: Best, David " Mix Data Submitted By: IATTIMORE CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 61 LAB C- 1231 2/13/2012 7 8 N/A 4 12.56 52890 4210 62 LAB C -1231 3/5/2012 28 8 N/A 4 12.56 74890 Atri 63 LAB C -1231 3/5/2012 28 8 N/A 4 12.56 75360 t 64 LAB HOLD HOLD 8 N/A 4 12.56 0 Specifications: 28 3600 Results to Date: PASS CC: Creststone Group, Glenn Thurman, Inc., City of Coppell, KART, City of Coppell, Creststone Group v 4L.- • Respectfully Submitted By: �— of Alpha Testing, Inc. Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or observed, and are not indicative of the qualities of apparently identical or similar specimens. 8 K , - r4?-r , iitIt iiii - ,r:Ire- - ;'7ir e 701 rit lt.ii i7,E .riti , I :3i( [t .4 il'1 �7i s = M ilf4.11 :lii f .- - 3iipr,(. 5 ' ': Alpha Testing, Inc. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, TX 75229 Report (972)620-8911 TBPE Firm No. 813 Our Report No.:110991-63 CRESTSTONE GROUP Tested For: ATTN:DAVID HAYES YONAS TANGA PM: 225 E. HWY 121, #120 COPPELL, TX 75019 (214) 488-5255 Fax Number: RED HAWK RESIDENTIAL Project Desc: NWC OF BETHEL SCHOOL RD. AND DENTON TAP RD. FIELD DATA PAVING Placement Location: DEVON DR.@ STATION 14+58.25 Sample Location: 2/6/2012952 Date Placed:Plant Number: 8:37 AM6292613 Time Placed:Delivery Ticket No.: 3.251551 Slump (ASTM C-143):Mix ID: 4.7(ASTM C-173)ALPHA Air Content:Made By: 35 Air Temperature: ASTM C-31 Cured Specification: 54 Specimen Temperature: 2/7/2012 Date Received: Best, David Field Data Submitted By: LATTIMORE Mix Data Submitted By: CYLINDER COMPRESSION TEST RESULTS LabCureCapDateAgeArea:Max BreakAvg.Avg.Avg Depth/ PSI: No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load: 65LABC-12312/13/201278N/A412.56543604330 66LABC-12313/5/2012288N/A412.56645805140 67LABC-12313/5/2012288N/A412.56596304750 68LABHOLDHOLD8N/A412.560 Specifications:283600 PASS Results to Date: Creststone Group, Glenn Thurman, Inc., City of Coppell, KART, City of Coppell, Creststone Group CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 128664 Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting Alpha Testing, Inc. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, TX 75229 Report (972)620-8911 TBPE Firm No. 813 Our Report No.:110991-64 CRESTSTONE GROUP Tested For: ATTN:DAVID HAYES YONAS TANGA PM: 225 E. HWY 121, #120 COPPELL, TX 75019 (214) 488-5255 Fax Number: RED HAWK RESIDENTIAL Project Desc: NWC OF BETHEL SCHOOL RD. AND DENTON TAP RD. FIELD DATA PAVING Placement Location: WASHINGTON CT.@ STATION 1+50 Sample Location: 2/6/2012995 Date Placed:Plant Number: 9:22 AM64316628 Time Placed:Delivery Ticket No.: 2.751551 Slump (ASTM C-143):Mix ID: 4.6(ASTM C-173)ALPHA Air Content:Made By: 41 Air Temperature: ASTM C-31 Cured Specification: 55 Specimen Temperature: 2/7/2012 Date Received: Best, David Field Data Submitted By: LATTIMORE Mix Data Submitted By: CYLINDER COMPRESSION TEST RESULTS LabCureCapDateAgeArea:Max BreakAvg.Avg.Avg Depth/ PSI: No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load: 69LABC-12312/13/201278N/A412.56460803670 70LABC-12313/5/2012288N/A412.56546304350 71LABC-12313/5/2012288N/A412.56558304450 72LABHOLDHOLD8N/A412.560 Specifications:283600 PASS Results to Date: Creststone Group, Glenn Thurman, Inc., City of Coppell, KART, City of Coppell, Creststone Group CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 128665 Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting Alpha Testing, Inc. 2209 Wisconsin St., Suite 100 Dallas, TX 75229 Concrete Compression Test (972)620 -8911 Report TBPE Firm No. 813 Tested For: CRESTSTONE GROUP Our Report No.: 110991 -65 ATTN: DAVID HAYES 225 E. HWY 121, #120 PM: YONAS TANGA COPPELL, TX 75019 Fax Number: (214) 488 -5255 Project Desc: RED HAWK RESIDENTIAL NWC OF BETHEL SCHOOL RD. AND DENTON TAP RD. FIELD DATA Placement Location: PAVING Sample Location: DEVON DR.@ STATION 12 +61.80 Date Placed: 2/6/2012 Plant Number: 955 Time Placed: 11:00 AM Delivery Ticket No.: 64316638 Slump (ASTM C -143): 3.5 Mix ID: 1551 Air Content: 5.3 (ASTM C -173) Made By: ALPHA Air Temperature: 47 Specimen Temperature: 58 Cured Specification: ASTM C -31 Date Received: 2/7/2012 Field Data Submitted By: Best, David Mix Data Submitted By: LATTIMORE CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 73 LAB C -1231 2/13/2012 7 8 N/A 4 12.56 57330 f 45.1 74 LAB C -1231 3/5/2012 28 8 N/A 4 12.56 75170 gien 75 LAB C -1231 3/5/2012 28 8 N/A 4 12.56 74390 67vtu 76 LAB HOLD HOLD 8 N/A 4 12.56 0 Specifications: 28 3600 Results to Date: PASS CC: Creststone Group, Glenn Thurman, Inc., City of Coppell, KART, City of Coppell, Creststone Group Respectfully Submitted By: 1 of Alpha Testing, Inc. Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and /or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or observed, and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 128666 Alpha Testing, Inc. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, TX 75229 Report (972)620-8911 TBPE Firm No. 813 Our Report No.:110991-66 CRESTSTONE GROUP Tested For: ATTN:DAVID HAYES YONAS TANGA PM: 225 E. HWY 121, #120 COPPELL, TX 75019 (214) 488-5255 Fax Number: RED HAWK RESIDENTIAL Project Desc: NWC OF BETHEL SCHOOL RD. AND DENTON TAP RD. FIELD DATA PAVING (HAND POUR) Placement Location: WASHINGTON CT.@ STATION 2+38.13 Sample Location: 2/6/2012952 Date Placed:Plant Number: 1:07 PM62926180 Time Placed:Delivery Ticket No.: 4.251701 Slump (ASTM C-143):Mix ID: 4.5(ASTM C-173)ALPHA Air Content:Made By: 50 Air Temperature: ASTM C-31 Cured Specification: 60 Specimen Temperature: 2/7/2012 Date Received: Best, David Field Data Submitted By: LATTIMORE Mix Data Submitted By: CYLINDER COMPRESSION TEST RESULTS LabCureCapDateAgeArea:Max BreakAvg.Avg.Avg Depth/ PSI: No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load: 77LABC-12312/13/201278N/A412.56579804620 78LABC-12313/5/2012288N/A412.56636405070 79LABC-12313/5/2012288N/A412.56651805190 80LABHOLDHOLD8N/A412.560 Specifications:284000 PASS Results to Date: Creststone Group, Glenn Thurman, Inc., City of Coppell, KART, City of Coppell, Creststone Group CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 128667 Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting Alpha Testing, Inc. Concrete Compression Test 2209 Wisconsin St., Suite 100 Dallas, TX 75229 Report (972)620-8911 TBPE Firm No. 813 Our Report No.:110991-67 CRESTSTONE GROUP Tested For: ATTN:DAVID HAYES YONAS TANGA PM: 225 E. HWY 121, #120 COPPELL, TX 75019 (214) 488-5255 Fax Number: RED HAWK RESIDENTIAL Project Desc: NWC OF BETHEL SCHOOL RD. AND DENTON TAP RD. FIELD DATA PAVING/DRIVE APPROACH FOR 12' DRIVE (HAND POUR) Placement Location: WASHINGTON DRIVE@ STATION 10+35 Sample Location: 2/6/2012952 Date Placed:Plant Number: 4:11 PM6292621 Time Placed:Delivery Ticket No.: 4.01701 Slump (ASTM C-143):Mix ID: 4.4(ASTM C-173)ALPHA Air Content:Made By: 53 Air Temperature: ASTM C-31 Cured Specification: 61 Specimen Temperature: 2/7/2012 Date Received: Best, David Field Data Submitted By: LATTIMORE Mix Data Submitted By: CYLINDER COMPRESSION TEST RESULTS LabCureCapDateAgeArea:Max BreakAvg.Avg.Avg Depth/ PSI: No.:Type:Type:Spec:Tested:(Days):LengthWidthDiameterSq. In.Load: 81LABC-12312/13/201278N/A412.56451203590 82LABC-12313/5/2012288N/A412.56609804860 83LABC-12313/5/2012288N/A412.56612304880 84LABHOLDHOLD8N/A412.560 Specifications:284000 PASS Results to Date: Creststone Group, Glenn Thurman, Inc., City of Coppell, KART, City of Coppell, Creststone Group CC: Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064 AND C138. Compression strength tests per ASTM C39. Our test results and reports are for the exclusive use of the Client (and their designated recepients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 128668 Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting