Loading...
Red Hawk-LR120309 ALPHA / \TESTING REPORT OF FIELD 2209 Wisconsin Street, Suite 100 COMPACTION TESTS Dallas, Texas 75229 Geotechnical 1 Construction Materials! Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Creststone Group DATE: 03/09/12 Coppell, Texas PROJECT: Red Hawk Residential OUR REPORT NO.: 110991-84 Coppell, Texas TEST DATA: TECHNICIAN: Jamshid Ranjbaran O PTIMUM MAXIMUM LAB IN PLACE IN PLACE TEST ELEV. SOIL ID PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT* NO. DEPTH NUMBER / PCF % PCF COMPACTION 758 03/09/12 SG 2 17.0 106.8 23.1 101 95 2 -A 759 03/09/12 FG -2.5 2 17.0 106.8 22.2 100 93 1 -A 760 03/09/12 FG -2.0 2 17.0 106.8 23.6 102 96 1 -A 761 03/09/12 FG -1.5 2 17.0 106.8 24.2 100 94 1 -A 762 03/09/12 FG -1.0 2 17.0 106.8 22.5 103 97 1 -A 763 03/09/12 SG 2 17.0 106.8 23.6 100 93 2 -A 764 03/09/12 FG -2.5 2 17.0 106.8 24.5 101 94 1 -A TEST LOCATION: Building Pad 758 15' N and 30' W from the SE Corner of Block B, Pad 12 759 30' N and 40' W from the SE Corner of Block B, Pad 12 760 20' N and 20' W from the SE Corner of Block B, Pad 12 761 25' N and 60' W from the SE Corner of Block B, Pad 12 762 35' N and 30' W from the SE Corner of Block B, Pad 12 763 15' N and 50' W from the SE Corner of Block B, Pad 11 764 30' N and 25' W from the SE Corner of Block B, Pad 11 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and /or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA / \TESTING REPORT OF FIELD 2209 Wisconsin Street, Suite 100 COMPACTION TESTS Dallas, Texas 75229 Geotechnical 1 Construction Materials! Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Creststone Group DATE: 03/09/12 Coppell, Texas PROJECT: Red Hawk Residential OUR REPORT NO.: 110991-84A Coppell, Texas TEST DATA: TECHNICIAN: Jamshid Ranjbaran O PTIMUM MAXIMUM LAB IN PLACE IN PLACE TEST ELEV. SOIL ID PERCENT DATE MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMMENT' NO. DEPTH NUMBER % PCF % PCF COMPACTION 765 03/09/12 FG -2.0 2 17.0 106.8 22.8 103 97 1 -A 766 03/09/12 FG -1.5 2 17.0 106.8 23.8 101 95 1 -A 767 03/09/12 FG -1.0 2 17.0 106.8 24.3 101 95 1 -A 768 03/09/12 FG -0.5 2 17.0 106.8 22.3 99 93 1 -A 769 03/09/12 FG 2 17.0 106.8 23.8 100 93 1 -A 770 03/09/12 FG -0.5 2 17.0 106.8 22.4 103 97 1 -A 771 03/09/12 FG 2 17.0 106.8 23.7 101 95 1 -A TEST LOCATION: Building Pad 765 20' N and 30' E from the SW Corner of Block B, Pad 11 766 30' N and 60' E from the SW Corner of Block B, Pad 11 767 15' N and 20' E from the SW Corner of Block B, Pad 11 768 10' N and 40' E from the SW Corner of Block B, Pad 15 769 25' N and 30' E from the SW Corner of Block B, Pad 15 770 35' N and 50' E from the SW Corner of Block B, Pad 14 771 15' N and 35' E from the SW Corner of Block B, Pad 14 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST , / Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and /or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and /or observed, and are not indicative of the qualities of apparently identical or similar Rnwnimnng DAILY FIELD REPORT 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 II Geotechnical Construction Materials Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR:Creststone GroupDATE:03/09/12 Coppell, Texas PROJECT:Red Hawk ResidentialOUR REPORT NO.:110991-85 Coppell, Texas TECHNICIAN: Jamshid Ranjbaran WEATHER:CloudyTEMPERATURE RANGE :40° to 50° The Alpha technician traveled to the above referenced site to monitor on-going work and perform field testing as requested. While on site the technicain verified plastic sheeting placed 12 inch below the top of a 3 foot moisture conditioned soil at Block B, Pad 14 & 15 per the recommendation in the project geotechnical repor. The contractor was informed of all observations and field test results. Respectfully Submitted, Yonas Tanga ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of Alpha. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.