Loading...
Alford Media-CS 98081308×13×98 1~:11 ?'~x N0.209 Q01 9?2 304 354? CITY/~ COPPELL a CITY OF COPPELL August 23, 299e Larry Davis, Construction Inspector Larry Smith, Utilities Division Walk-thru forA%ford Media Listed below are Street Division comments relative to walk thru. Manhole near building need~ chimney seal & rain pan installed. Raise double-checks on both domestic & irrigation about 1-1/Z feet high. Clean out fire_~drant valve in back so wrench valve can be used. R__epair fire hydrant at end of Oak Grove. nut on fire h~drant. Re~lace operating_ Manhole near creek bed needs grout outside manhole. chimne~__seal & rain~ Manhole between Oak Grove and parking lot needs rain pan and ~eal; al~o_~rout outside manhole. Need to move pad over so cleanout can be inspected. ~drant %2 from Oak Grove needs extension installed.____