Loading...
Ashton Ridge-LR 960911 (2)ALPHA TESTINGS, NC. 2750 Northaven Rd., Suite 203 Dallas, Texas 75229 (214) 620-8911 MECHANICAL LIME STABILIZATION REPORT FINAL MIX TESTED FOR DEVELOPMENT, INC, ~INLEY DEVELOPMENT ~DDISON~ TEX~S DATE PROJECT Area of Work: ASHTON RIDGE COPPELL, TEXAS STREETS OUR REPORT NO. 96362-25A Date lime initially applied 09,/.10/96 Average final compacted depth: Date of final mixing 09,/.11,/96 6 inches. Sample Location BRIGHTONWAY @ STATION 1+00 BRIGHTONWAY @ STATION 4+00 · TEST DATA 100% Passing 60% Passing 3/4" Sieve #4 Sieve 100 60 100 61 Plasticity Index Remarks: