Loading...
Bethel Estates 1-CS 991216 (2) CITY OF COPPELL PLANNING DEPARTMENT STAFF REPORT CASE NO.: PD-181, BETHEL ROAD ESTATES P & Z HEARING DATE: December 16, 1999 C.C. HEARING DATE: January 11, 2000 LOCATION: Along the north side of W. Bethel Road, approximately 700' east of Hearthstone Lane. SIZE OF AREA: 3.2 acres of property, being proposed for two residential lots. CURRENT ZONING: C (Commercial) REQUEST: PD-SF-12 (Planned Development, Single Family-12), to create two building sites. APPLICANT: Owner: Purchaser: Mary Meyers and Fred Joyce Terry Holmes 1017 William D. Tate Ave. 1406 Halsey Way, Ste. 100 Grapevine, TX. 76051 Carrollton, TX. 75007 (817) 481-3516 (972) 242-1770 Fax: (817) 481-4593 Fax: (972) 242-2931 HISTORY: There has been no recent development history on the subject tract. TRANSPORTATION: Bethel Road as an unimproved two-lane, asphalt road contained within a variable width r.o.w. The Thoroughfare Plan calls for it to be developed with a minimum 27-foot pavement and 50 foot r.o.w. SURROUNDING LAND USE & ZONING: North- single-family residential; PD SF-9 South - vacant; PD SF-9 East - single family residence; "C", Commercial West -single-family residence; "C", Commercial Page # 9 COMPREHENSIVE PLAN: The Comprehensive Plan shows the property as suitable for a use allowed in the Historic District (residential uses are allowed). DISCUSSION: This is a request to change zoning from Commercial to residential allowing the development of two 12,000 square foot plus residential lots. Lot one will contain .85 acres of land, lot two, 2.4 acres. PD zoning is being requested primarily to eliminate the alley requirement of residential development, a request that has been approved for several other subdivisions within this general neighborhood. Although partially included within the 100 year floodplain, the applicant understands that no development can occur-even with a change of zoning-until the floodplain has been revised to remove the building sites from the floodplain. The PD would allow the elimination of alleys adjacent to the creek, a reduction of the side yard setbacks, and introduce more flexibility in the development of this vacant parcel. The only major concern of staff regarding this application is the fact that we would prefer to limit the access to these two lots to one central driveway. Because of the grades of Bethel Road, the short distance that would occur if two driveways were allowed, and the proximity of the bridge just east of this site, one driveway would make for a safer development. The applicant has resisted our recommendation stating that a future homeowner here would prefer individual drives. RECOMMENDATION TO THE PLANNING AND ZONING COMMISSION: Staff supports this request provided the following conditions are followed: -one driveway for the two lots; zoning exhibit to "PD SF-12" -a circulation plan that allows all vehicular maneuvering on the lots and not on Bethel Road (read: no backing into Bethel Road) -complete tree survey acceptable to Leisure Services -payment of $1285 park development fee per lot -no development is allowed in the 100-year floodplain -minimum finished floor will be one foot above the ultimate flood elevation -all other staff comments ALTERNATIVES: 1) Recommend approval of the request 2) Recommend disapproval of the request ATTACHMENTS: 1) Zoning Exhibit/Site Plan 2) Tree Survey 3) Departmental Comments Page # 9 DE VEL OPMENT RE VIE W COJB 5% , ENGINEERING COMMENTS ITEM: PD-181, Bethel Road Estates, a zoning change request from "C" Commercial to "PD-SF-12" Planned Development, Single Family-12, to allow the development of 2 residential lots on $.2 acres of property located along the north side orE. Bethel Road, approximately 700' east of Hearthstone Lane, at the request of Mary Myers and Fred 3oyce. DRC DATE: November 25, 1999 and Deeember 2, 1999 CONTACT: Mike Martin, P.E., Assistant City Engineer (972-304-$679) COMMENTSTATU$: r~r~r nxrz~ra r~v ,/FINAL r~wt/rcwr~ 1. No development will be allowed in the 100-year floodplain until a flood study is submitted and approved. 2. The minimum finished floor will need to be 1' above the ultimate flood elevation per the City Floodplain Management Ordinance. 3. The final grades for the driveways and screening fence will need to be coordinated with the Engineering Department to minimize future conflict with Coppell Road. 4. Due to the typical erosion of creeks, creek embankment stabilization may be necessary. 12/09×99 16:49 CITY.I~c COPPELL a 992 304 9092 .,,. N0.074 D03 DEVELOPMENT REVIEW COMM/TTEE ITEM: Bethel Road Estates, Zoning Change DR¢ DAli: November 23, 199~ and December 2~ 19~9 CONTACT: Brad Reid, Park Planning and Landscape I III IIIIIIII II COMMENT STATUS: PRELIMINARY F-tNA~_~ The tree survey complete. The trees designated as being preserved will be reviewed during and after construction to det~,~i~ine if proper preservation techniques have been utilized. Mitigation for additional trees removed may be required. The developer should be aware that the Park Development Ordinance is in affect for this development requiring $1,285.00 per dwelling unit. )Rczzz¥'