PA0101-LR010612CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Frwy., Suite//100 Report Number: 94011093.0012 Dallas, Texas 75247 Service Date: May 18, 2001 ,,~ (214) 630-101o Client: City of Coppell - Parks & Recreation Reporl Da~/~ 12, 2001 ~-~ 'J;:>/3, O J-O J Attn: Brad Reid Projec~ew Brown Park EastJ ~ ~l~loore Road 732 DeForest ~Coppell, Texas Coppell TX 75019 Project~ Material Information S~mple ~ Specified Strength: 3000 psi @ 28 Days Sample Time: 8:00am Date Cast: May 18, 2001 Technician: Terry L. Smith Batch Time: 7:41am Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 50 Truck No: 68 Ticket No: 2893190 Placement Method: Pump Mix I.D. No.: 8272 Sample Locations: 5' N & 12' E from SW corner Placement Location: Paving Field Test Data Test Result Specification Test Method Slump, inches: 5.00 3-5 ASTM C-143 Air Content, %: 3-6 ASTM C-172 Concrete Temperature,o F: 70 ASTM C-39 Ambient Temperature, o F: 7 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 1 1 6.00 05/25/2001 7 115,790 4,090 1 2 6.00 05/25/2001 7 116,750 4,130 Average 4,110 1 3 06/15/2001 28 I 4 06/15/2001 28 Services - Obtain samples of fresh concrete at the placement locations, pedorm required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page I of 2 o,~w~-~,,~,.~ CONCRETE COMPRESSIVE STRENGTH TEST 8901 Carpenter Frwy., Suite #100 Report Number: 94011093.0012 Dallas, Texas 75247 Service Date: May 18, 2001 (214) 630-1OLO Client: City of Coppell- Parks & Recreation Report Date: June 12, 2001 Attn: Brad Reid Project: Andrew Brown Park East 732 DeForest Moore Road Coppell TX 75019 Coppell, Texas Project Number: 94011093 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Sample Time: 11:35am Date Cast: May 18, 2001 Technician: Terry L. Smith Batch Time: 10:1 lam Plant: 41 Weather Conditions: Clear Supplier: TXI Accumulative Yards: 130 Truck No: 54 Ticket No: 2893518 Placement Method: Pump Mix i.D. No.: 8272 Sample Locations: 21' N & 10' W from SE corner Placement Location: See page 1 Field Test Data Test Result Specification Test Method Slump, inches: 6.00 3-5 ASTM C-143 Air Content, %: 3-6 ASTM C-172 Concrete Temperature,o F: 86 ASTM C-39 Ambient Temperature, o F: 90 Plastic Unit Weight, pcf: Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Date Test Load Strength No. ID (inches) Tested (days) (lbs) (psi) 2 1 6.00 05/25/2001 7 94,210 3,330 2 2 6.00 05/25/2001 7 95,260 3,370 Average 3,350 2 3 06/15/2001 28 2 4 06/15/2001 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Technician: Terry L. Smith Report Distribution: ~~/~eering, Inc. (1) City of Coppell- Parks & Recreation (1) TLB Construction Reviewed by: (1) City of Coppell - Constr. Insp. Eric Jl,~leveland, P.E. Senior Project Engineer The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the wdtten approval of Terracon. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2