PA0101-LR010619 CONCRETE
COMPRESSIVE STRENGTH TEST
Report Number: 94011093.0012 S9Ol Carpenter Frwy., Suite #100
Dallas, Texas 75247
Service Date: May 18, 200~ (214) e3O-lOlO
Client: City of Coppell - Parks & Recreation June 19, 2001
Attn: Brad Reid Project: Andrew Brown Park East
732 DeForest Moore Road
Coppell TX 75019 Coppell, Texas
ect Number: 94011093
Material Information
Specified Strength: 3000 psi @ 28 Days Sam Date Cast: May 18, 2001
Technician: Terry L. Smith
Batch Time: 7:41 am Plant: 41 Weather Conditions: Clear
Supplier: TXl Accumulative Yards: 50
Truck No: 68 Ticket No: 2893190 Placement Method: Pump
Mix I.D. No.: 8272 Sample Locations: 5' N & 12' E from SW corner
Placement Location: Paving
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.00 3-5 ASTM O-143
Air Content, %: 3-6 ASTM C-172
Concrete Temperature,o F: 70 ASTM C-39
Ambient Temperature, o F: 7
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Date Test Load Strength
No. ID (inches) Tested (days) (lbs) (psi)
1 1 6.00 0512512001 7 115,790 4,090
1 2 6.00 05/25/2001 7 116,750 4,130
Average 4,110
1 3 6.00 06/15/2001 28 124,100 4,390
1 4 6.00 06/15/2001 28 126,080 4,460
Average 4,430
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 2 0~ LLw~*~.
CONCRETE COMPRESSIVE STRENGTH TEST
8901 Carpenter Frwy., Suite #100
Report Number: 94011093.0012 Dallas, Texas 75247
Service Date: May 18, 2001 (214) 63o-lolo
Client: City of Coppell - Parks & Recreation Report Date: June 19, 2001
Attn: Brad Reid Project: Andrew Brown Park East
732 DeForest Moore Road
Coppell TX 75019 Coppell, Texas
Project Number: 94011093
Material Information Sample Information
Specified Strength: 3000 psi @ 28 Days Sample Time: 11:35am Date Cast: May 18, 2001
Technician: Terry L. Smith
Batch Time: 10:1lam Plant: 41 Weather Conditions: Clear
Supplier: TXl Accumulative Yards: 130
Truck No: 54 Ticket No: 2893518 Placement Method: Pump
Mix I.D. No.: 8272 Sample Locations: 21' N & 10' W from SE corner
Placement Location: See page 1
Field Test Data
Test Result Specification Test Method
Slump, inches: 6.00 3-5 ASTM O-143
Air Content, %: 3-6 ASTM C-172
Concrete Temperature,O F: 86 ASTM C-39
Ambient Temperature, o F: 90
Plastic Unit Weight, pcf:
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Date Test Load Strength
No. ID (inches) Tested (days) (lbs) (psi)
2 1 6.00 05/25/2001 7 94,210 3,330
2 2 6.00 05/25/2001 7 95,260 3,370
Average 3,350
2 3 6.00 06/15/2001 28 120,030 4,240
2 4 6.00 06/15/2001 28 120,430 4,260
Average 4,250
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Technician: Terry L. Smith
Report Distribution: ~~ , Inc.
(1) City of Coppell - Parks & Recreation
(1) TLB Construction Reviewed by:
(1) City of Coppell - Constr. Insp. Eric J. Cleveland, P.E.
Senior Project Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written approval of Terracon. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 2 of 2