Loading...
ST1002-LR120421CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,200 psi @ 48 days Mix ID: 1701 Supplier: Lattimore Batch Time: 1416 Plant: Truck No.: 5028 Ticket No.: 9556431924 Field Test Data Test Result Specification Slump (in): 3 3-5 Air Content ( %): 4.2 3-6 Concrete Temp. (F): 78 Ambient Temp. (F): 76 Sample Date: 03/23/12 Sample Time: 1545 Sampled By: Adain Wood Weather Conditions: Clear Accumulative Yards: 7 Batch Size (cy): 7 Placement Method: Direct Discharge Water Added Before (gal): 0 Water Added After (gal): 0 Sample Location: Sta. 5 +10, south bound East Main Street Placement Location: Inlets Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 1 1 6.00 28.27 03/24/12 03/30/12 7 121,720 4,310 5 1 2 6.00 28.27 03/24/12 03/30/12 7 127,890 4,520 4 Average (7 days) 4,420 1 3 6.00 28.27 03/24/12 04/20/12 28 143,110 5,060 4 1 4 6.00 28.27 03/24/12 04/20/12 28 142,770 5,050 2 Average (28 days) 5,060 Comments: Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Adain Wood Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E. (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 1 of 1 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1851 Supplier: Lattimore Batch Time: 0807 Plant: 95 Truck No.: 7059 Ticket No.: 564319178 Field Test Data Test Result Specification Slump (in): 41/2 3-5 Air Content ( %): 5.2 3-6 Concrete Temp. (F): 67 Ambient Temp. (F): 57 Sample Date: 03/23/12 Sample Time: 0900 Sampled By: Adain Wood Weather Conditions: Clear Accumulative Yards: 20 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal): 5 Water Added After (gal): 0 Sample Location: Sta. 5 +00 Placement Location: Paving - South bound East Main ID Street driveways Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 1 1 6.00 28.27 03/24/12 03/27/12 4 114,740 4,060 2 1 2 6.00 28.27 03/24/12 03/30/12 7 131,500 4,650 4 1 3 6.00 28.27 03/24/12 03/30/12 7 135,360 4,790 4 Average (7 days) 4,720 1 4 6.00 28.27 03/24/12 04/20/12 28 171,710 6,070 2 1 5 6.00 28.27 03/24/12 04/20/12 28 161,840 5,720 2 Average (28 days) 5,900 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Adain Wood Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 1 of 3 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,000 psi @ 28 days Mix ID: 1851 Supplier: Lattimore Batch Time: 1008 Plant: 95 Truck No.: 1120 Ticket No.: 564319194 Field Test Data Test Result Specification Slump (in): 5 3-5 Air Content ( %): 5.8 3-6 Concrete Temp. (F): 73 Ambient Temp. (F): 68 Sample Date: 03/23/12 Sample Time: 1100 Sampled By: Adain Wood Weather Conditions: Clear Accumulative Yards: 110 Batch Size (cy): 10 Placement Method: Direct Discharge Water Added Before (gal): 5 Water Added After (gal): 0 Sample Location: Sta. 2 +25 Placement Location: Paving - South bound East Main ID Street driveways Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 2 1 6.00 28.27 03/24/12 03/27/12 4 115,550 4,090 5 2 2 6.00 28.27 03/24/12 03/30/12 7 129,170 4,570 5 2 3 6.00 28.27 03/24/12 03/30/12 7 127,740 4,520 4 Average (7 days) 4,550 2 4 6.00 28.27 03/24/12 04/20/12 28 156,370 5,530 2 2 5 6.00 28.27 03/24/12 04/20/12 28 158,050 5,590 4 Average (28 days) 5,560 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Adain Wood Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 2 of 3 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,000 psi (a, 28 days Sample Date: 03/23/12 Sample Time: 1315 Sampled By: Adain Wood Mix ID: 1851 Weather Conditions: Clear Supplier: Lattimore Accumulative Yards: 220 Batch Size (cy): 10 Batch Time: 1203 Plant: 95 Placement Method: Direct Discharge Truck No.: 1120 Ticket No.: 564319212 Water Added Before (gal): 10 Water Added After (gal): 0 Field Test Data Sample Location: Sta. 0 +15 Test Result Specification Placement Location: Paving - South bound East Main Slump (in): 41/2 3-5 Street driveways Air Content ( %): 4.2 3-6 Concrete Temp. (F): 78 Ambient Temp. (F): 73 Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 3 1 6.00 28.27 03/24/12 03/27/12 4 105,480 3,730 5 3 2 6.00 28.27 03/24/12 03/30/12 7 121,500 4,300 5 3 3 6.00 28.27 03/24/12 03/30/12 7 130,130 4,600 2 Average (7 days) 4,450 3 4 6.00 28.27 03/24/12 04/20/12 28 150,760 5,330 4 3 5 6.00 28.27 03/24/12 04/20/12 28 147,220 5,210 2 Average (28 days) 5,270 Comments: Average compressive strength of 28 day cylinders complies with the specified strength. Not tested for plastic unit weight. Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Adain Wood Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E. (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 3 of 3 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,500 psi (a, 28 days Sample Date: 04/13/12 Sample Time: 0800 Sampled By: Randall Hollis Mix ID: 1851 Weather Conditions: Cloudy Supplier: Lattimore Area Accumulative Yards: 40 Batch Size (cy): 10 Batch Time: 0713 Plant: 955 Placement Method: Direct Discharge Truck No.: 1091 Ticket No.: 64320535 Water Added Before (gal): 10 Field Test Data Tested Water Added After (gal): 0 (psi) Type Sample Location: East side of parking Test Result Specification Placement Location: Paving - East side of parking between Slump (in): 61/2 3 -5 3,810 Travis & Burns Air Content ( %): 5.3 3 -6 6.00 28.27 Concrete Temp. (F): 78 7 131,310 Ambient Temp. (F): 67 1 3 Plastic Unit Wt. (pcf): 144.8 04/14/12 04/20/12 Yield (Cu. Yds.): 129,990 4,600 2 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 1 1 6.00 28.27 04/14/12 04/17/12 4 107,650 3,810 4 1 2 6.00 28.27 04/14/12 04/20/12 7 131,310 4,640 2 1 3 6.00 28.27 04/14/12 04/20/12 7 129,990 4,600 2 Average (7 days) 4,620 1 4 6.00 28.27 04/14/12 05/11/12 28 1 5 6.00 28.27 04/14/12 05/11/12 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Randall Hollis Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 1 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,500 psi (a, 28 days Sample Date: 04/13/12 Sample Time: 1017 Sampled By: Randall Hollis Mix ID: 1851 Weather Conditions: Cloudy Supplier: Lattimore Accumulative Yards: 120 Batch Size (cy): 10 Batch Time: 0937 Plant: 955 Placement Method: Direct Discharge Truck No.: 9113 Ticket No.: 64320556 Water Added Before (gal): 5 Water Added After (gal): 0 Field Test Data Sample Location: 70 yds from E end of parking Test Result Specification Placement Location: Paving - East side of parking between Slump (in): 61/2 3 -5 Travis & Burns Air Content ( %): 4.6 3 -6 Concrete Temp. (F): 77 Ambient Temp. (F): 72 Plastic Unit Wt. (pcf): 145.2 Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 2 1 6.00 28.27 04/14/12 04/17/12 4 100,030 3,540 5 2 2 6.00 28.27 04/14/12 04/20/12 7 119,980 4,240 2 2 3 6.00 28.27 04/14/12 04/20/12 7 118,890 4,210 2 Average (7 days) 4,230 2 4 6.00 28.27 04/14/12 05/11/12 28 2 5 6.00 28.27 04/14/12 05/11/12 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength samples. Terracon Rep.: Randall Hollis Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 2 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,500 psi (a, 28 days Sample Date: 04/13/12 Sample Time: 1244 Sampled By: Randall Hollis Mix ID: 1851 Weather Conditions: Partly cloudy Supplier: Lattimore Accumulative Yards: 210 Batch Size (cy): 10 Batch Time: 1151 Plant: 955 Placement Method: Direct Discharge Truck No.: 9114 Ticket No.: 64320573 Water Added Before (gal): 20 Water Added After (gal): 0 Field Test Data Sample Location: 10 yds S of entrance to parking, S side Test Result Specification of Travis Slump (in): 5 1/2 3 -5 Placement Location: Paving - East side of parking between Air Content ( %): 4.6 3 -6 Travis & Burns Concrete Temp. (F): 84 Ambient Temp. (F): 77 Plastic Unit Wt. (pcf): 145.5 Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 3 1 6.00 28.27 04/14/12 04/17/12 4 105,240 3,720 4 3 2 6.00 28.27 04/14/12 04/20/12 7 118,040 4,180 2 3 3 6.00 28.27 04/14/12 04/20/12 7 116,380 4,120 2 Average (7 days) 4,150 3 4 6.00 28.27 04/14/12 05/11/12 28 3 5 6.00 28.27 04/14/12 05/11/12 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Randall Hollis Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 3 of 4 CONCRETE COMPRESSIVE STRENGTH TEST REPORT Material Information Sample Information Specified Strength: 4,500 psi (a, 28 days Sample Date: 04/13/12 Sample Time: 1515 Sampled By: Randall Hollis Mix ID: 1851 Weather Conditions: Partly cloudy Supplier: Lattimore Accumulative Yards: 310 Batch Size (cy): 10 Batch Time: 1427 Plant: 955 Placement Method: Direct Discharge Truck No.: 9113 Ticket No.: 64320597 Water Added Before (gal): 0 Water Added After (gal): 0 Field Test Data Sample Location: Entrance to parking, off of Haimnond Test Result Specification betwween Travis & Houston Slump (in): 4 3 -5 Placement Location: Paving - East side of parking between Air Content ( %): 3.9 3 -6 Travis & Burns Concrete Temp. (F): 86 Ambient Temp. (F): 79 Plastic Unit Wt. (pcf): 147.8 Yield (Cu. Yds.): Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Date Test Load Strength Fracture No. ID (in) (sq in) Received Tested (days) (ibs) (psi) Type 4 1 6.00 28.27 04/14/12 04/17/12 4 120,200 4,250 4 4 2 6.00 28.27 04/14/12 04/20/12 7 127,850 4,520 2 4 3 6.00 28.27 04/14/12 04/20/12 7 129,800 4,590 2 Average (7 days) 4,560 4 4 6.00 28.27 04/14/12 05/11/12 28 4 5 6.00 28.27 04/14/12 05/11/12 28 Comments: Samples Made By: Terracon Services: Obtain samples of fresh concrete at the placement locations, perfonn required field tests and cast compressive strength sainples. Terracon Rep.: Randall Hollis Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Eric J. Cleveland, P.E. (1) Freese and Nichols Inc, Emailed (1) 7R7 Paving LP, Emailed Senior Project Manager Test Methods: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231 The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CROOO1, 8- 27 -11, Revs Page 4 of 4 SAMPLE PICK -UP REPORT Irerracon Report Number: 94111246.0164 Service Date: 04/17/12 8901 Carpenter Frwy. Suite 100 Report Date: 04/21/12 Dallas, TX 75247 214 - 630 -1010 Reg No:F -3272 Client Project City of Coppell TX Old Town Coppell & Bethel Road Attn: Rick O'Dell #ST10 -02 Engineering Dept Between Coppell Rd & Freeport PO Box 9478 Coppell, TX Coppell, TX 75019 Project Number: 94111246 TOTAL NUMBER OF CONCRETE CYLINDERS PICKED UP: 6 Report No.: 94111246.0162 No. of Cylinders: 6 Services: Concrete cylinder pickup. Terracon Rep.: Christopher Amoah Reported To: Contractor: Report Distribution: (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed (1) City of Coppell TX, Emailed Reviewed By: (1) Freese and Nichols Inc, Emailed (1) JRJ Paving LP, Emailed Eric J. Cleveland, P.E. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. BC0001, 10- 25 -10, Rev.9 Page 1 of 1 dgr