Vista Point 2R-LR060408 CONCRETE COMPRESSIVE STF JGTH TEST llèrracon
Report Number: 94061113.0004
Service 8901 Carpenter Frwy,Ste#100
ervice Date: March 28, 2006
Dallas,Texas 75247
(214)630-1010
Client: Report Date:April 08, 2006
SpawMaxwell Co Project: 609 East Highway 121
Attn: Bobby Thompson Highway 121 between
6565 North MacArthur Blvd Ste 225 MacArthur& Denton Tap
Irving TX 75039 Coppell, TX
Project No.: 94061113
Material Information Sample Information
Specified Strength: 3000 psi @ 28 Days Date Cast: March 28, 2006 Time: 10:03am
Technician: Ira S. Haynes
Batch Time: N/A Plant: Mobil Mixer Weather Conditions: Clear
Supplier: CustomCrete Co Accumulative Yards: 8.5/8.5
Truck No: 379 Ticket No: 343310 Placement Method: Motor Bucket
Mix I.D. No.: CC1070A Sample Locations: Refer to Placement Location
Water Added Onsite Before Test: 0Gallons Placement Location: Electrical & Plumbing Backfill
Water Added Onsite After Test: 0 Gallons
Field Test Data
Test Result Specification Test Method
Slump, inches: 5.00 ASTM C143
Air Content, %: 3.1 ASTM C231
Concrete Temperaturep F: 72 ASTM C1064
Ambient Temperature,o F: 75 ASTM C1064
Plastic Unit Weight, pcf: N/A ASTM C138
Laboratory Test Data
Age at Maximum Compressive
Set Specimen Diameter Area Date Test Load Strength
No. ID (inches)(sq. inches) Tested (days) (Ibs) (psi)
1 1 6.00 28.27 04/04/2006 7 60,290 2,130
1 2 6.00 28.27 04/04/2006 7 57,280 2,030
Average (7 Days) 2,080
1 3 04/25/2006 28
1 4 04/25/2006 28
Comments:
NOTE: Concrete truck arrived at approximately 10:00 a.m.
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Terracon Rep: Ira S. Haynes
Report Distribution:
(1)SpewMaxwell Co
(1)City of Coppell TX Reviewed by: -,,ZALiilla"
(1)City of Coppell TX
Robert D. RaA .T.
Senior Proj- 'anager
The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 01-PDR/ROI-Future Key