Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Signature-SY111201 (2)
PROJECT NO. 17792.1 DECEMBER 2011 LIMITED SUBSURFACE INVESTIGATION PROPOSED SENIOR LIVING FACILITY SANDY LAKE ROAD AT RIVERVIEW DRIVE COPPELL, TEXAS Presented To: SIGNATURE ASSISTED LIVING, LLC HEALTH CARE REIT, INC. HCRI TEXAS PROPERTIES, LTD. C/O SDR DEVELOPMENT, INC. SARASOTA, FLORIDA December 28, 2011 Project No. 17792.1 Signature Assisted Living, LLC Health Care REIT, Inc. HCRI Texas Properties, Ltd. c/o SDR Development, Inc. nd 1800 2 Street, Suite 717 Sarasota, Florida 34236 ATTN: Mr. Pete Russell RE: Limited Subsurface Investigation Proposed Senior Living Facility Sandy Lake Road at Riverview Drive Coppell, Texas Dear Mr. Russell: Reed Engineering Group, Ltd. (Reed) has performed a Limited Subsurface Investigation (LSI) at the above-referenced property in accordance with the scope of work that was authorized by SDR Development, Inc. on November 17, 2011. The proposed scope of work was based on the findings of a Phase I Environmental Site Assessment (ESA) completed by Reed in November 2011. Purpose and Scope The results of Reed’s Phase I ESA identified recognized environmental conditions associated with: the indicated presence of a Closed Landfill Inventory site adjacent to or on the subject property with the potential to have affected the subject property; and undocumented fill placed throughout the property during apparent mining operations and subsequent filling activities. Based on these findings, Reed prepared a scope of work consisting of the installation of test pits to observed for the presence of fill material. Additionally, Reed proposed the installation of five borings/groundwater monitor wells to assess soil and groundwater conditions across the site. The scope of this LSI is limited and was intended to assess if impact to soil and/or groundwater has occurred in selected, representative areas and to observe for fill material in selected areas considered to be representative of the site as a whole. This investigation was not designed to delineate the lateral or vertical extent of contamination, if encountered, and should not be construed as a comprehensive assessment of the site. 2424 STUTZ DR. SUITE 400 DALLAS, TX 75235 [214] 350 5600 [214] 350 0019 TELFAX SDR Development, Inc. Proposed Senior Living Facility Project No. 17792.1 December 28, 2011 Page 2 of 7 Field Activities Test Pits Reed performed oversight of test pit installation on November 22, 2011. Sunbelt Industrial Services was subcontracted by Reed to dig pits using a tracked excavator (Kobelco SK 135 SR) equipped with a two-foot wide bucket. Test pits typically averaged two to three feet in width, 10 to 12 feet in length, and 10 to 16 feet in depth below ground surface (bgs). A total of 16 test pits were installed across the subject property. Locations of test pits are depicted on Figure 1 Illustration inthesection of the report. Reed observed the excavation of each test pit. Reed observed the presence of fill soil at each location at depths ranging from ground surface down to 3 to 6 feet. In the northeastern-most portion of the site (TP-14), fill was encountered at depths down to approximately 12 feet bgs. Fill soils were observed to be underlain by clayey sand or sandy clay soils, followed by clayey soil. Fill soil appeared to consistently be comprised of sandy and silty clays. Additionally, small quantities of limestone fragments were often observed in the fill soil. Reed also observed several limestone boulders, occasional bricks, limited quantities of asphalt (at one location), a metal fence post, a metal sign, a metal cable, and a metal pipe fragment. Observed materials appeared to be considerably less than one percent of fill observed and were noted to be materials that are typically chemically inert. No obvious visual indication of chemical impact was observed during field activities. No odors suggestive of potential impact were noted. No volatile vapors were detected during field screening as read by a flame ionization detector (FID). Given the absence of field indicators of impact, no soil was collected for analyses. Upon completion of observation activities, each pit was backfilled with excavated soil. Field notes describing general observations at each test pit, FID screening intervals/readings, Test Pit Log and other recorded information is including in the section of the report. Boring/Monitoring Well Installation Reed performed drilling activities on December 1 and 2, 2011. This portion of the LSI consisted of drilling and collecting soil samples from five borings. The borings were subsequently converted to permanent monitor wells following completion. Boring locations Illustrations are illustrated in Figure 1 in the section of this Report. Borings were drilled by Reed utilizing a truck-mounted conventional auger rotary drill rig equipped with 5.75-inch flight augers. Augers, barrels, drilling equipment and sampling tools used during field operations were decontaminated using a hot water power washer or an Alconox-water solution and potable water rinse prior to and between each use. Soil samples SDR Development, Inc. Proposed Senior Living Facility Project No. 17792.1 December 28, 2011 Page 3 of 7 were collected in 2-foot Shelby tubes. The sampling tubes were advanced ahead of the augers to collect undisturbed soil samples. The soil samples were then field extruded from the sampling tubes. Selected soil samples from the fill soil interval were placed in pre-cleaned glass jars sealed o with Teflon-lined screw-on lids and placed on ice in a cooler to maintain a 4C holding temperature. Another portion of each sample and deeper soil samples were placed in a zipper- type plastic bag, sealed, and left in the ambient environment to allow volatile vapors to accumulate in the bag. These samples were later analyzed for headspace gases with a flame- ionization detection (FID) meter as a field-screening procedure to aid in sample selection for subsequent chemical analyses. No detections were indicated during field screening activities. Borings were advanced into the uppermost groundwater bearing unit. MW-1 and MW-2 were completed at depths of 20 feet bgs and MW-5 at 25 feet bgs. MW-3 and MW-4 were completed at depths of 40 feet bgs due to an absence of groundwater upon completion of the borings. The monitor wells installed as part of this investigation were constructed by placing the casing into the previously drilled open borehole. Individual lengths of screen and casing were flush- threaded so that no glues or solvents were necessary to join the sections. Each well was constructed with 10 feet of casing and screen comprising the balance of the well. All casing materials were factory pre-cleaned, plastic wrapped, and boxed to ensure that no oils, grease, or other contaminants were present at the time of well construction. Casing material consisted of 2-inch diameter, Schedule 40 PVC pipe and factory-slotted casing with 0.010-inch widths. The filter pack, consisting of clean 10-20 sand, was installed within the annular space from the total depth of the well to approximately two feet above the top of the screened interval. The annular space above the filter pack was sealed with hydrated bentonite to within inches of the ground surface. Groundwater monitor wells were initially developed to remove stagnant groundwater and silts and other materials introducing during drilling activities. Groundwater was collected using a peristaltic pump equipped with new polyethylene tubing changed/discarded between wells. Groundwater samples were transferred to clean appropriate containers. The samples were o properly labeled, entered into the Chain-of-Custody form, and maintained at 4C for delivery to the analytical laboratory. The environmental technician conducting the sampling wore 100% Nitrile gloves, which were changed prior to sampling each well. Physical Setting Based on a review of geologic literature and experience in the area, the site is situated on Quaternary-age alluvium overlying shale of the Cretaceous-age Eagle Ford Formation. The alluvium is associated with floodplain deposition by Denton Creek and the Elm Fork Trinity SDR Development, Inc. Proposed Senior Living Facility Project No. 17792.1 December 28, 2011 Page 4 of 7 River in the geologic past. The alluvial soils typically consist of high plasticity clays grading with depth into sandy clays and clayey sands. The Eagle Ford shale is expected to be approximately 100 feet thick in the site vicinity. Observations made during this LSI appear indicated shallow alluvial soil overlying residual soil of the underlying weathered Eagle Ford shale which was encountered in some areas at depths greater than 30 feet bgs. Static groundwater observed at the site during the duration of this investigation was noted a depths ranging between 10 to 20 feet bgs. The groundwater flow direction and gradient are anticipated to mimic surface topography and be toward Denton Creek. Laboratory Methods Xenco Laboratories in Dallas, Texas, analyzed each of the soil and groundwater samples. The analyses were performed according to U.S. Environmental Protection Agency (EPA) and Texas Commission on Environmental Quality (TCEQ) methods. Soil samples were initially analyzed for TPH, VOCs, and metals. Based on a TPH detection in one soil sample, a polynuclear aromatic hydrocarbons (PAHs) analysis was performed. Groundwater samples were analyzed for total petroleum hydrocarbons (TPHs), volatile organic compounds (VOCs), and metals. One sample from each soil boring was submitted for analyses. Samples were collected from the interval of fill. Groundwater was collected at each well location and analyzed. Analytical Results Soil Analytical Results TPH concentrations for each soil sample were reported below laboratory detection limits with the exception of sample MW-5 3-5’. MW-5 3-5’ was reported with the detectable presence of TPH (C6-C12) in soil at a concentration of 472 mg/kg, TPH (C12-C28) at a concentration of 422 mg/kg, and TPH (C28-C35) at 73.5 mg/kg compared to the applicable Texas Risk Reduction Program (TRRP) Tier 1 Protective Concentration Levels (PCLs) for Residential Soil GW Protective of Groundwater Ingestion (Soil) of Class 1 or 2 Groundwater of 65 mg/kg, 198 Ing mg/kg, and 198 mg/kg, respectively. TPH (C28-C35) was noted to be below the applicable PCL. Given the PCL exceedances of TPH ranges C6-C12 and C12-C28, Reed release additional soil from sample MW-5 3-5’ for PAHs analysis for further environmental screening. PAH analysis for this sample indicated concentrations below laboratory detection limits. Based on no detections of PAH constituents above laboratory detection limits, together with VOC analysis for this sample (discussed below) which indicate VOC constituents below applicable PCLs, TPH range exceedances at MW-5 3-5’ are not considered to present a concern to the subject property. SDR Development, Inc. Proposed Senior Living Facility Project No. 17792.1 December 28, 2011 Page 5 of 7 VOC concentrations for each soil sample were reported below laboratory detection limits with the exception of MW-4 3-5’ and MW-5 3-5’. Detections of methylene chloride, tetrachloroethylene, and toluene were reported in sample MW-4 3-5’. Detections of cis-1,2- dichloroethylene, ethylbenzene, naphthalene, methylene chloride, n-propylbenzene, tetrachloroethylene, toluene, 1,2,4-trimethylbenzene, o-xylene, and m,p-xylene were reported in sample MW-5 3-5’. Based on review of quality control documentation, Methylene chloride was indicated to be a laboratory contaminant. VOC constituents listed above from samples GW MW-4 3-5’ and MW-5 3-5’ were noted to be less than applicable SoilPCLs. Ing Metals analysis indicated the detectable presence of metal concentrations in each of the samples. The metals arsenic, barium, cadmium, chromium, lead, mercury detected across the GW site were noted to be below applicable SoilPCLs and/or Texas-specific soil background Ing concentrations. Selenium, detected in sample MW-5 3-5’ was reported at a concentration of 2.64 mg/kg, exceeding its respective PCL and background concentration of 2.3 mg/kg and 0.3 mg/kg, respectively. The detectable presence of selenium appears to be associated with TPH and VOC contaminants (discussed above) in this sample. Given that no detection of selenium was reported in groundwater from this bore/well location (discussed below), it appears that selenium, that was noted to slightly exceed its PCL, has not affected underlying groundwater. Tables A tabular summary of detected soil constituents is included as Table 1 in the section of this report. Groundwater Analytical Results TPH was not detected above laboratory detection limits in groundwater samples collected from each of the five monitor wells. VOCs were not detected above laboratory detection limits in samples collected from monitor wells with the exception of MW-3, reported with VOC constituents: methyl chloride, ethylbenzene, and methylene chloride. Methylene chloride was the only constituent noted to GW exceed its respective TRRP Tier 1 PCL protective of groundwater ingestion (GW) of ING Class 1 or 2 Groundwater. However, the methylene chloride in this sample was flagged by the laboratory as a probable laboratory contaminant. Based on the common presence of methylene chloride as a laboratory contaminant, this concentration exceedance is not considered representative of site conditions and does not present a concern to the subject property. Metals analysis indicated the detectable presence of metal concentrations in each of the samples. The metals arsenic, barium, chromium, lead, and silver detected across the site were GW noted to be below applicable GWPCLs. ING Tables A tabular summary of detected constituents in groundwater is included as Table 2 in the section of this report. SDR Development, Inc. Proposed Senior Living Facility Project No. 17792.1 December 28, 2011 Page 6 of 7 Conclusions Reed observed the presence of fill soil in each test pit location at depths ranging from the ground surface down to 3 to 6 feet. In the northeastern-most portion of the site (TP-14), fill was encountered at depths down to approximately 12 feet. The material presence of non-soil fill material, debris, and/or waste was not observed during the installation of test pits across the site. Small quantities of limestone fragments were often observed in fill soil. Reed observed limestone boulders, occasion bricks, limited quantities of asphalt, a metal fence post, a metal sign, a metal cable, and a metal pipe fragment. Observed materials appeared to be considerably less than one percent of fill observed and noted to be materials that are typically chemically inert. Field indicators of obvious chemical impact were not indicated during test pit installation activities at the site. Results of the soil sample analyses indicate that, within the areas investigated, shallow soils at MW-4 and MW-5 are impacted with TPH range compounds and/or VOCs. Contaminants were noted with concentrations below applicable comparison criteria with the exception of TPH exceedances at MW-5. However, based on no detections of PAH constituents above laboratory detection limits, together with detected VOCs at this location with concentrations below applicable comparisons criteria, TPH range exceedances at MW-5 3-5’ are not considered to present a concern to the subject property. Further, selenium detected in sample MW-5 3-5’ was reported at a concentration of 2.64 mg/kg, exceeding its respective PCL and background concentration of 2.3 mg/kg and 0.3 mg/kg, respectively. The detectable presence of selenium appears to be associated with TPH and VOC contaminants in this sample. Given that no detection of selenium was reported in groundwater from this bore/well location, it appears that selenium, that was noted to slightly exceed its PCL, has not affected underlying groundwater. Results of groundwater analyses indicate that, within the areas investigated, groundwater has been impacted by VOC constituents at MW-3 at concentrations below applicable TRRP Tier 1 GW GW PCLs with the exception of methylene chloride. Based on the common presence of ING methylene chloride as a laboratory contaminant and its presence in method blanks indicated by the laboratory, this concentration exceedance is not considered representative of site conditions and does not present a concern to the subject property. Metals detected in groundwater are below applicable PCLs. SDR Development, Inc. Proposed Senior Living Facility Project No. 17792.1 December 28, 2011 Page 7 of 7 We hope this information meets your needs. If Reed may be of continued assistance, do not hesitate to call. Sincerely, REED ENGINEERING GROUP, LTD. Registration Number F-3114 Christopher S. McCaslin, P.G. Senior Geologist Karen Harvey Project Geologist The seal appearing on this document was authorized by Christopher S. McCaslin, P.G. 10490, on December 28, 2011. CSM/KLH/csm ILLUSTRATIONS L E G E N D - LIMESTONE BOULDERS - POWER POLE WITH TRANSFORMER TP-16 - POWER POLE WITH METER - POWER POLE - PARKED CATERPILLAR LOADER - FIRE HYDRANT - OVERHEAD ELECTRIC - CONCRETE FRAGMENTS TP-15 MW-5 TP-3 MW-2 TP-4TP-14 TP-8 TP-9 TP-13 SHORT GRASS TP-2 AND WEEDS MW-3 TP-5 TP-12 TP-7TP-10 TP-1 TP-11 TP-6 MW-4 INLET INLET SANDY LAKE ROAD REED ENGINEERING Limited Subsurface Investigatior GROUP GEOTECHNICAL AND ENVIRONMENTAL CONSULTANTS 2424 STUTZ DRIVE, SUITE 400 DALLAS, TX 75235 0150' 75' SITE PLAN FIGURE 1 Feet Scale TABLES TABLE I - SUMMARY OF SOIL ANALYTICAL RESULTS Proposed Assisted Living Facility Sandy Lake Road Coppell, Texas Tier 1 Texas- GW SOIL Specific Soil ING PCLBackground Result (mg/kg)(mg/kg) Sample IDParameter(mg/kg) Barium93.8444300 Cadmium0.2431.51-- Chromium142,40030 MW-1 3-5'Lead11.63.0315 Mercury0.006330.00780.04 TPHND---- VOCsND---- Barium76.9444300 Chromium10.82,40030 Lead8.153.0315 MW-2 3-5' Mercury0.004310.00780.04 TPHND---- VOCsND---- Barium71.6444300 Chromium11.42,40030 Lead11.73.0315 MW-3 3-5' Mercury0.008500.00780.04 TPHND---- VOCsND---- Barium97.2444300 Chromium12.42,40030 Lead9.483.0315 Mercury0.004840.00780.04 MW-4 3-5' TPHND---- Methylene Chloride* 0.00523BJ0.013-- Tetrachloroethylene 0.000275J0.050-- Toluene0.000561J8.21-- Arsenic 3.475.025.9 Barium84.5444300 Chromium9.612,40030 Lead12.93.0315 Selenium2.642.300.3 Mercury0.004590.00780.04 TPH (C6-C12)47265-- TPH (C12-C28)422198-- TPH (C28-C35)73.5198-- cis-1,2-dichloroethylene0.00103J0.248-- MW-5 3-5' Ethylbenzene0.000362J7.63-- Naphthalene0.00208J31.3-- Methylene Chloride* 0.00887BJ0.013-- n-Propylbenzene0.000385J44.8-- Tetrachloroethylene 0.000257J0.050-- Toluene0.00204J8.21-- 1,2,4-Trimethylbenzene0.000782J48.5-- o-Xylene0.000432J70.7-- m,p-Xylene0.00106J105-- PAHsND---- Only the detected constituents are listed. J-indicates estimated value. B-Analyte identified in method blank (potential lab. contaminant) ND - not detected " -- " - No criteria or not applicable * Suspect Laboratory Contaminant TABLE II - SUMMARY OF GROUNDWATER ANALYTICAL RESULTS Proposed Assisted Living Facility Sandy Lake Road Coppell, Texas Tier 1 GW GW PCL Result ING (mg/L) (mg/L) Sample IDParameter Barium0.3402.0 MW-1 TPHND-- VOCsND-- Barium0.2462.0 MW-2 TPHND-- VOCsND-- Arsenic0.0096J0.01 Barium0.046J2.0 Chromium0.001J0.1 Lead0.0059J0.015 MW-3 Silver0.0006J0.122 TPHND-- Methyl Chloride0.00042J0.07 Ethylbenzene0.00018J0.70 Methylene Chloride*0.0051B0.005 Arsenic0.0073J0.01 Barium0.083J2.0 Chromium0.0004J0.1 MW-4 Lead0.0036J0.015 Silver0.0008J0.122 TPHND-- VOCsND-- Arsenic0.0075J0.01 Barium0.05752.0 Chromium0.0007J0.1 MW-5 Lead0.0067J0.015 Silver0.0013J0.122 TPHND-- VOCsND-- Only the detected constituents are listed. J-indicates estimated value. B-indicates analyte identified in method blank (potential lab. contaminant) Exceeds applicable regulatory criteria ND - not detected " -- " - No criteria or not applicable * Suspect laboratory contaminant TEST PIT LOG ;·tz·[m t©¦;7{;z©[zÝzmC-zz·ä {7ä[;w77wzÝ;©Ýz;Þ5©zÝ; /¦¦;r;ã t©;-·bu u ;·tz·L5tL·;©Ý²E·u{z5;-©z¦·zt©,,;CzjCza·;©z5;-©z¦·zCL5w;7zm¦¦ TP101Brown,Sandy/SiltyClayYesSoilandoccasionallimestonecobble0 14DarkBrown,SiltyClayYesSoilandoccasionlimestoneboulder0 412Brown,ClayeyVeryfineSandNoN/A0 TP205DarkBrown,Sandy/SiltyClayYesSoil,onebrick,onepieceofmetal,limestonefragments0 512Brown,ClayeyVeryfineSandNoN/A0 TP303.5DarkBrown,Sandy/SiltyClayYesSoil0 3.510Brown,ClayeyVeryfineSandNoN/A0 1014Brown,SandyClayNoN/A0 TP402DarkBrownandRedSandyClayYesSoilandLimestonefragments0 23DarkBrown,SiltyClayYesSoil0 38Brown,ClayeyVeryfineSandNoN/A0 815DarkGray,SiltyClayNoN/A0 TP501DarkBrown,SiltyClayYesSoil0 13BrownandRed,SiltyClayYesSoilandLimestonefragments0 36Brown,SiltyClayYesSoilandoccasionroot0 69Brown,ClayeyVeryfineSandNoN/A0 916DarkGray,SiltyClayNoN/A0 TP601DarkBrown,SiltyClayYesSoil0 12WhiteClayeySandYesSoilandLimestonefragments0 24.5DarkGray,SiltyClayYesSoil,Limestonefragments,smallquantityofbrickfragments0 4.58Brown,ClayeyVeryfineSandNoN/A0 816DarkBrown,SiltyClayNoN/A0 TP701DarkBrown,SiltyClayYesSoil0 12WhiteClayeySandYesSoil0 26DarkBrown,SiltyClayYesSoil0 612Brown,ClayeyVeryfineSandNoN/A0 TP805DarkBrown,Sandy/SiltyClayYesSoil,limestonefragments,onemetalfencepostandsign0 59Brown,ClayeyVeryfineSandNoN/A0 0 912DarkBrown,SiltyClayNoN/A TP901DarkBrown,Silty/SandyClayYesSoil0 12.5Brown,SandyClayYesSoilandLimestoneboulders0 2.55DarkBrown,SiltyClayYesSoil0 59Brown,ClayeyVeryfineSandNoN/A0 912DarkGray,SiltyClayNoN/A0 TP1001.5OrangeandDarkBrownSand&SiltyClayYesSoil0 1.53.5Brown,Sandy/SiltyClayYesSoilandLimestonefragments0 3.55DarkBrown,SiltyClayYesSoilandonebrick0 510Brown,ClayeyVeryfineSandNoN/A0 1012DarkBrown,SiltyClayNoN/A0 TP1101DarkBrown,Sandy/SiltyClayYesSoil0 12BrownandOrange,SandyClayYesSoilandLimestonefragments0 23.5WhiteandBrown,SiltyClayYesSoilandLimestonefragments0 3.510Brown,ClayeyVeryfineSandNoN/A0 TP1201Brown,Sandy/SiltyClayYesSoil0 16DarkBrown,Sandy/SiltyClayYesSoil0 611Brown,ClayeyVeryfineSandNoN/A0 1114DarkGray,SiltyClayNoN/A0 TP1301Brown/OrangeSandyClayYesSoil0 14Brown,Sandy/SiltyClayYesSoilandLimestonefragments0 45.5DarkBrownSiltyClayYesSoil0 5.510Brown,ClayeyVeryfineSandNoN/A0 TP1401.5DarkBrown,Sandy/SiltyClayYesSoil0 1.59GrayishBrown,SandyClayYesSoil,Limestonefragmentsandboulder,onemetalcable,onemetalpipe0 912DarkBrown,SiltyClayNoN/A0 TP1501DarkBrown,Sandy/SiltyClayYesSoil0 13Orangishbrown,SiltyClayYesSoilandLimestonefragments0 35Orange,SandyClayYesSoil0 55.5Whiteband,LimestonefragmentsYesLimestone0 5.510Brown,ClayeyVeryfineSandNoN/A0 1012DarkBrown,SiltyClayNoN/A0 TP1601DarkBrown,Sandy/SiltyClayYesSoil0 12OrangishBrown,Sandy/SiltyClayYesSoil0 26DarkBrown,Silty/SandyClayYesSoil,limestone,smallquantityofasphalt,andconcrete0 610Brown/GrayishOlive,SiltyClay,mottledUncertainUncertain0 1012DarkGray,SiltyClayNoN/A0 LABORATORY REPORTS Analytical Report 432603 for Reed Engineering Group, Inc. Project Manager: Chris McCaslin 17792.1 17792.1 09-DEC-11 Collected By: Client Celebrating 20 Years of commitment to excellence in Environmental Testing Services 9701 Harry Hines Blvd, Dallas, TX 75220 Ph:(214) 902-0300 Fax:(214) 351-9139 Xenco-Houston (EPA Lab code: TX00122): Texas (T104704215-10-6-TX), Arizona (AZ0765), Arkansas (08-039-0), Connecticut (PH-0102), Florida (E871002) Illinois (002082), Indiana (C-TX-02), Iowa (392), Kansas (E-10380), Kentucky (45), Louisiana (03054) New Hampshire (297408), New Jersey (TX007), New York (11763), Oklahoma (9218), Pennsylvania (68-03610) Rhode Island (LAO00312), USDA (S-44102) Xenco-Atlanta (EPA Lab Code: GA00046): Florida (E87429), North Carolina (483), South Carolina (98015), Utah (AALI1), West Virginia (362), Kentucky (85) Louisiana (04176), USDA (P330-07-00105) Xenco-Miami (EPA Lab code: FL01152): Florida (E86678), Maryland (330) Xenco-Tampa Mobile (EPA Lab code: FL01212): Florida (E84900) Xenco-Odessa (EPA Lab code: TX00158): Texas (T104704400-TX) Xenco-Dallas (EPA Lab code: TX01468): Texas (T104704295-TX) Xenco Phoenix (EPA Lab Code: AZ00901): Arizona(AZ0757) Xenco-Phoenix Mobile (EPA Lab code: AZ00901): Arizona (AZM757) Xenco Tucson (EPA Lab code:AZ000989): Arizona (AZ0758) Page 1 of 23 Final 1 09-DEC-11 Chris McCaslin Project Manager: Reed Engineering Group, Inc. 2424 Stutz Drive, Suite 400 Dallas, TX 75235 432603 Reference: XENCO Report No: 17792.1 Project Address: Coppell Chris McCaslin : We are reporting to you the results of the analyses performed on the samples received under the project name referenced above and identified with the XENCO Report Number432603. All results being reported under this Report Number apply to the samples analyzed and properly identified with a Laboratory ID number. Subcontracted analyses are identified in this report with either the NELAC certification number of the subcontract lab in the analyst ID field, or the complete subcontracted report attached to this report. Unless otherwise noted in a Case Narrative, all data reported in this Analytical Report are in compliance with NELAC standards. Estimation of data uncertainty for this report is found in the quality control section of this report unless otherwise noted. Should insufficient sample be provided to the laboratory to meet the method and NELAC Matrix Duplicate and Matrix Spike requirements, then the data will be analyzed, evaluated and reported using all other available quality control measures. The validity and integrity of this report will remain intact as long as it is accompanied by this letter and reproduced in full, unless written approval is granted by XENCO Laboratories. This report will be filed for at least 5 years in our archives after which time it will be destroyed without further notice, unless otherwise arranged with you. The samples received, and described as recorded in Report No. 432603 will be filed for 60 days, and after that time they will be properly disposed without further notice, unless otherwise arranged with you. We reserve the right to return to you any unused samples, extracts or solutions related to them if we consider so necessary (e.g., samples identified as hazardous waste, sample sizes exceeding analytical standard practices, controlled substances under regulated protocols, etc). We thank you for selecting XENCO Laboratories to serve your analytical needs. If you have any questions concerning this report, please feel free to contact us at any time. Respectfully, Carlos Castro Laboratory Manager Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Austin - Tampa - Miami - Atlant Page 2 of 23 Final 1 CASE NARRATIVE Client Name: Reed Engineering Group, Inc. Project Name: 17792.1 09-DEC-11 Project ID: 17792.1Report Date: Work Order Number: 12/02/2011 432603Date Received: Sample receipt non conformances and comments: Xenco Houston Xenco Houston Sample receipt non conformances and comments per sample: None Analytical non nonformances and comments: Batch:LBA-876565VOAs by SW-846 8260B SW8260B Batch 876565, 1,1,1-Trichloroethane, Bromochloromethane, Trichlo above QC limits in the Matrix Spike. Bromodichloromethane, Dichl above QC limits in the Matrix Spike and Matrix Spike Duplicate. above QC limits in the Matrix Spike Duplicate. Samples affected are: 432603-001, -002, -003. The Laboratory Control Sample for Bromodichloromethane, Bromochl Dichloroethane, Trichlorofluoromethane, Dichlorodifluoromethane, within laboratory Control Limits Page 3 of 23 Final 1 Certificate of Analysis Summary432603 Reed Engineering Group, Inc., Dallas, TX Project Name:17792.1 Project Id:17792.1 Date Received in Lab:Fri Dec-02-11 04:40 pm Chris McCaslin Contact: Report Date:09-DEC-11 Project Location:Coppell Project Manager:Monica Tobar Lab Id: 432603-001432603-002432603-003 Field Id: MW-1 3-5'MW-2 3-5'MW-3 3-5' Analysis Requested Depth: 3-5 ft 3-5 ft 3-5 ft Matrix: SOLIDSOLIDSOLID Sampled: Dec-01-11 08:30Dec-01-11 09:30Dec-01-11 10:30 Mercury by SW7471A Extracted: Dec-07-11 08:00Dec-07-11 08:00Dec-07-11 08:00 Analyzed: Dec-07-11 11:37Dec-07-11 11:43Dec-07-11 11:45 Units/RL:ug/kgRLug/kgRLug/kgRL Mercury6.333.024.312.878.502.83 Metals per ICP by SW846 6010B Extracted:Dec-07-11 06:30Dec-07-11 06:30Dec-07-11 06:30 Analyzed: Dec-07-11 10:32Dec-07-11 10:53Dec-07-11 10:57 Units/RL: mg/kgRLmg/kgRLmg/kgRL 0.4760.4630.481 ArsenicBRLBRLBRL 0.4760.4630.481 Barium93.876.971.6 Cadmium 0.2430.238 BRL 0.231 BRL 0.240 Chromium14.0 0.238 10.8 0.231 11.4 0.240 Lead11.6 0.571 8.15 0.556 11.7 0.577 SeleniumBRL 0.476 BRL 0.463 BRL 0.481 SilverBRL 0.190 BRL 0.185 BRL 0.192 TPH by Texas1005 Extracted: Dec-06-11 15:42Dec-06-11 15:45Dec-06-11 15:48 SUB: TX104704215 Analyzed: Dec-07-11 02:42Dec-07-11 03:05Dec-07-11 03:28 Units/RL:mg/kgRLmg/kgRLmg/kgRL C6-C12 Gasoline Range Hydrocarbons BRL50.0BRL49.7BRL49.9 C12-C28 Diesel Range Hydrocarbons BRL50.0BRL49.7BRL49.9 C28-C35 Oil Range Hydrocarbons BRL50.0BRL49.7BRL49.9 Total TPH 1005 BRL50.0BRL49.7BRL49.9 This analytical report, and the entire data package it represents, has been made for your exclusive and confidential use. The interpretations and results expressed throughout this analytical report represent the best judgment of XENCO Laboratories. XENCO Laboratories assumes no responsibility and makes no warranty to the end use of the data hereby presented. Our liability is limited to the amount invoiced for this work order unless otherwise agreed to in writing. ________________________________ Houston - Dallas - San Antonio - Atlanta - Tampa - Boca Raton - Latin America - Odessa - Corpus Christi Carlos Castro Laboratory Manager Page 4 of 23 Final 1 Certificate of Analysis Summary432603 Reed Engineering Group, Inc., Dallas, TX Project Name:17792.1 Project Id:17792.1 Date Received in Lab:Fri Dec-02-11 04:40 pm Chris McCaslin Contact: Report Date:09-DEC-11 Project Location:Coppell Project Manager:Monica Tobar Lab Id: 432603-001432603-002432603-003 Field Id: MW-1 3-5'MW-2 3-5'MW-3 3-5' Analysis Requested Depth: 3-5 ft 3-5 ft 3-5 ft Matrix: SOLIDSOLIDSOLID Sampled: Dec-01-11 08:30Dec-01-11 09:30Dec-01-11 10:30 VOAs by SW-846 8260B Extracted: Dec-07-11 14:30Dec-07-11 14:32Dec-07-11 14:34 SUB: TX104704215 Analyzed: Dec-07-11 19:06Dec-07-11 19:28Dec-07-11 19:50 Units/RL:mg/kgRLmg/kgRLmg/kgRL BenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 BromobenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 BromochloromethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 BromodichloromethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 BromoformBRL 0.00500 BRL 0.00500 BRL 0.00500 Methyl bromide BRL 0.00500 BRL 0.00500 BRL 0.00500 MTBEBRL 0.00500 BRL 0.00500 BRL 0.00500 0.005000.005000.00500 tert-ButylbenzeneBRLBRLBRL 0.005000.005000.00500 Sec-ButylbenzeneBRLBRLBRL 0.005000.005000.00500 n-ButylbenzeneBRLBRLBRL 0.005000.005000.00500 Carbon Tetrachloride BRLBRLBRL 0.005000.005000.00500 ChlorobenzeneBRLBRLBRL 0.01000.01000.0100 ChloroethaneBRLBRLBRL 0.005000.005000.00500 ChloroformBRLBRLBRL 0.01000.01000.0100 Methyl Chloride BRLBRLBRL 2-ChlorotolueneBRL 0.00500 BRL 0.00500 BRL 0.00500 4-ChlorotolueneBRL 0.00500 BRL 0.00500 BRL 0.00500 p-Cymene (p-Isopropyltoluene) BRL 0.00500 BRL 0.00500 BRL 0.00500 1,2-Dibromo-3-ChloropropaneBRL 0.00500 BRL 0.00500 BRL 0.00500 DibromochloromethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,2-DibromoethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 Methylene bromide BRL 0.00500 BRL 0.00500 BRL 0.00500 1,2-DichlorobenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 0.005000.005000.00500 1,3-DichlorobenzeneBRLBRLBRL 0.005000.005000.00500 1,4-DichlorobenzeneBRLBRLBRL This analytical report, and the entire data package it represents, has been made for your exclusive and confidential use. The interpretations and results expressed throughout this analytical report represent the best judgment of XENCO Laboratories. XENCO Laboratories assumes no responsibility and makes no warranty to the end use of the data hereby presented. Our liability is limited to the amount invoiced for this work order unless otherwise agreed to in writing. ________________________________ Houston - Dallas - San Antonio - Atlanta - Tampa - Boca Raton - Latin America - Odessa - Corpus Christi Carlos Castro Laboratory Manager Page 5 of 23 Final 1 Certificate of Analysis Summary432603 Reed Engineering Group, Inc., Dallas, TX Project Name:17792.1 Project Id:17792.1 Date Received in Lab:Fri Dec-02-11 04:40 pm Chris McCaslin Contact: Report Date:09-DEC-11 Project Location:Coppell Project Manager:Monica Tobar Lab Id: 432603-001432603-002432603-003 Field Id: MW-1 3-5'MW-2 3-5'MW-3 3-5' Analysis Requested Depth: 3-5 ft 3-5 ft 3-5 ft Matrix: SOLIDSOLIDSOLID Sampled: Dec-01-11 08:30Dec-01-11 09:30Dec-01-11 10:30 VOAs by SW-846 8260B Extracted: Dec-07-11 14:30Dec-07-11 14:32Dec-07-11 14:34 SUB: TX104704215 Analyzed: Dec-07-11 19:06Dec-07-11 19:28Dec-07-11 19:50 Units/RL:mg/kgRLmg/kgRLmg/kgRL DichlorodifluoromethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,2-DichloroethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,1-DichloroethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 trans-1,2-dichloroethyleneBRL 0.00500 BRL 0.00500 BRL 0.00500 cis-1,2-DichloroethyleneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,1-DichloroetheneBRL 0.00500 BRL 0.00500 BRL 0.00500 2,2-DichloropropaneBRL 0.00500 BRL 0.00500 BRL 0.00500 0.005000.005000.00500 1,3-DichloropropaneBRLBRLBRL 0.005000.005000.00500 1,2-DichloropropaneBRLBRLBRL 0.005000.005000.00500 trans-1,3-dichloropropeneBRLBRLBRL 0.005000.005000.00500 1,1-DichloropropeneBRLBRLBRL 0.005000.005000.00500 cis-1,3-DichloropropeneBRLBRLBRL 0.005000.005000.00500 EthylbenzeneBRLBRLBRL 0.005000.005000.00500 HexachlorobutadieneBRLBRLBRL 0.01000.01000.0100 NaphthaleneBRLBRLBRL IsopropylbenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 Methylene Chloride BRL 0.0200 BRL 0.0200 BRL 0.0200 n-PropylbenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 StyreneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,1,1,2-TetrachloroethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,1,2,2-TetrachloroethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 TetrachloroethyleneBRL 0.00500 BRL 0.00500 BRL 0.00500 TolueneBRL 0.00500 BRL 0.00500 BRL 0.00500 0.005000.005000.00500 1,2,4-TrichlorobenzeneBRLBRLBRL 0.005000.005000.00500 1,2,3-TrichlorobenzeneBRLBRLBRL This analytical report, and the entire data package it represents, has been made for your exclusive and confidential use. The interpretations and results expressed throughout this analytical report represent the best judgment of XENCO Laboratories. XENCO Laboratories assumes no responsibility and makes no warranty to the end use of the data hereby presented. Our liability is limited to the amount invoiced for this work order unless otherwise agreed to in writing. ________________________________ Houston - Dallas - San Antonio - Atlanta - Tampa - Boca Raton - Latin America - Odessa - Corpus Christi Carlos Castro Laboratory Manager Page 6 of 23 Final 1 Certificate of Analysis Summary432603 Reed Engineering Group, Inc., Dallas, TX Project Name:17792.1 Project Id:17792.1 Date Received in Lab:Fri Dec-02-11 04:40 pm Chris McCaslin Contact: Report Date:09-DEC-11 Project Location:Coppell Project Manager:Monica Tobar Lab Id: 432603-001432603-002432603-003 Field Id: MW-1 3-5'MW-2 3-5'MW-3 3-5' Analysis Requested Depth: 3-5 ft 3-5 ft 3-5 ft Matrix: SOLIDSOLIDSOLID Sampled: Dec-01-11 08:30Dec-01-11 09:30Dec-01-11 10:30 VOAs by SW-846 8260B Extracted: Dec-07-11 14:30Dec-07-11 14:32Dec-07-11 14:34 SUB: TX104704215 Analyzed: Dec-07-11 19:06Dec-07-11 19:28Dec-07-11 19:50 Units/RL:mg/kgRLmg/kgRLmg/kgRL 1,1,2-TrichloroethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,1,1-TrichloroethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 TrichloroethyleneBRL 0.00500 BRL 0.00500 BRL 0.00500 TrichlorofluoromethaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,2,3-TrichloropropaneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,2,4-TrimethylbenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 1,3,5-TrimethylbenzeneBRL 0.00500 BRL 0.00500 BRL 0.00500 0.002000.002000.00200 Vinyl Chloride BRLBRLBRL 0.005000.005000.00500 o-XyleneBRLBRLBRL 0.01000.01000.0100 m,p-XylenesBRLBRLBRL This analytical report, and the entire data package it represents, has been made for your exclusive and confidential use. The interpretations and results expressed throughout this analytical report represent the best judgment of XENCO Laboratories. XENCO Laboratories assumes no responsibility and makes no warranty to the end use of the data hereby presented. Our liability is limited to the amount invoiced for this work order unless otherwise agreed to in writing. ________________________________ Houston - Dallas - San Antonio - Atlanta - Tampa - Boca Raton - Latin America - Odessa - Corpus Christi Carlos Castro Laboratory Manager Page 7 of 23 Final 1 Flagging Criteria X In our quality control review of the data a QC deficiency was observed and flagged as noted. MS/MSD recoveries were found to be outside of the laboratory control limits due to possible matrix /chemical interference, or a concentration of target analyte high enough to affect the recovery of the spike concentration. This condition could also affect the relative percent difference in the MS/MSD. B A target analyte or common laboratory contaminant was identified in the method blank. Its presence indicates possible field or laboratory contamination. D The sample(s) were diluted due to targets detected over the highest point of the calibration curve, or due to matrix interference. Dilution factors are included in the final results. The result is from a diluted sample. E The data exceeds the upper calibration limit; therefore, the concentration is reported as estimated. F RPD exceeded lab control limits. J The target analyte was positively identified below the quantiation limit and above the detection limit. U Analyte was not detected. L The LCS data for this analytical batch was reported below the laboratory control limits for this analyte. The department supervisor and QA Director reviewed data. The samples were either reanalyzed or flagged as estimated concentrations. H The LCS data for this analytical batch was reported above the laboratory control limits. Supporting QC Data were reviewed by the Department Supervisor and QA Director. Data were determined to be valid for reporting. K Sample analyzed outside of recommended hold time. JN A combination of the "N" and the "J" qualifier. The analysis indicates that the analyte is "tentatively identified" and the associated numerical value may not be consistent with the amount actually present in the environmental sample. * Surrogate recovered outside laboratory control limit. BRL Below Reporting Limit. RL Reporting Limit MDLSDLLOD Method Detection LimitSample Detection LimitLimit of Detection PQLMQLLOQ Practical Quantitation Limit Method Quantitation LimitLimit of Quantitation DL Method Detection Limit NC Non-Calculable + Outside XENCO's scope of NELAC Accreditation. ^NELAC or State program does not offer Accreditation at this time. Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Atlanta - Midland/Odessa - Tamp Phone Fax 4143 Greenbriar Dr, Stafford, TX 77477 (281) 240-4200 (281) 240-4280 9701 Harry Hines Blvd , Dallas, TX 75220 (214) 902 0300 (214) 351-9139 5332 Blackberry Drive, San Antonio TX 78238 (210) 509-3334 (210) 509-3335 2505 North Falkenburg Rd, Tampa, FL 33619 (813) 620-2000 (813) 620-2033 5757 NW 158th St, Miami Lakes, FL 33014 (305) 823-8500 (305) 823-8555 12600 West I-20 East, Odessa, TX 79765 (432) 563-1800 (432) 563-1713 6017 Financial Drive, Norcross, GA 30071 (770) 449-8800 (770) 449-5477 3725 E. Atlanta Ave, Phoenix, AZ 85040 (602) 437-0330 Page 8 of 23 Final 1 Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432603,17792.1 876419432603-001 / SMP1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 02:42 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 92.299.99270-130 o-Terphenyl 47.250.09470-130 876419432603-002 / SMP1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 03:05 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 93.299.49470-130 o-Terphenyl 47.649.79670-130 876419432603-003 / SMP1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 03:28 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 1-Chlorooctane 89.999.89070-130 o-Terphenyl 45.449.99170-130 876565432603-001 / SMP1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 19:06 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 4-Bromofluorobenzene 0.05790.050011658-152 Dibromofluoromethane 0.05650.050011374-126 1,2-Dichloroethane-D4 0.05320.050010680-120 Toluene-D8 103 0.05150.050073-132 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 9 of 23 Final 1 Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432603,17792.1 876565432603-002 / SMP1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 19:28 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05450.050010958-152 Dibromofluoromethane 0.05580.050011274-126 1,2-Dichloroethane-D4 0.05450.050010980-120 Toluene-D8 0.05270.050010573-132 876565432603-003 / SMP1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 19:50 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05690.050011458-152 Dibromofluoromethane 0.05730.050011574-126 1,2-Dichloroethane-D4 0.05770.050011580-120 Toluene-D8 0.05270.050010573-132 876419615049-1-BLK / BLK1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 20:59 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 98.11009870-130 o-Terphenyl 46.850.09470-130 876565615127-1-BLK / BLK1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 13:58 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05350.050010758-152 Dibromofluoromethane 0.05400.050010874-126 1,2-Dichloroethane-D4 0.04920.05009880-120 Toluene-D8 0.05120.050010273-132 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 10 of 23 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432603,17792.1 876419615049-1-BKS / BKS1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 21:22 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 96.71009770-130 o-Terphenyl 40.750.08170-130 876565615127-1-BKS / BKS1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 12:52 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05250.050010558-152 Dibromofluoromethane 0.05390.050010874-126 1,2-Dichloroethane-D4 0.05590.050011280-120 Toluene-D8 0.05460.050010973-132 876419432724-001 S / MS1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 22:08 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 90.799.69170-130 o-Terphenyl 39.849.88070-130 876565432333-002 S / MS1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 17:59 Units: Amount TrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05460.050010958-152 Dibromofluoromethane 0.05820.050011674-126 1,2-Dichloroethane-D4 0.05420.050010880-120 Toluene-D8 0.05320.050010673-132 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 11 of 23 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432603,17792.1 876419432724-001 SD / MSD1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 22:31 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 93.799.89470-130 o-Terphenyl 44.549.98970-130 876565432333-002 SD / MSD1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/07/11 18:21 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05220.050010458-152 Dibromofluoromethane 0.05600.050011274-126 1,2-Dichloroethane-D4 0.05490.050011080-120 Toluene-D8 0.05400.050010873-132 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 12 of 23 Final Blank Spike Recovery Project Name: 17792.1 : Work Order # 432603:17792.1 Project ID Lab Batch #: 876419615049-1-BKSSolid Sample:Matrix: 12/06/201112/06/2011 Date Analyzed:Date Prepared:Analyst:JAH Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/kg1 Batch #: BlankSpikeBlankBlankControl TPH by Texas1005 ResultAddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <50.010001010 10175-125 C6-C12 Gasoline Range Hydrocarbons <50.01000891 8975-125 C12-C28 Diesel Range Hydrocarbons Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 13 of 23 Final Blank Spike Recovery Project Name: 17792.1 : Work Order # 432603:17792.1 Project ID Lab Batch #: 876565615127-1-BKSSolid Sample:Matrix: 12/07/201112/07/2011 Date Analyzed:Date Prepared:Analyst:CYE Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/kg1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.005000.05000.0549 11066-142 Benzene <0.005000.05000.0538 10875-125 Bromobenzene <0.005000.05000.0574 11573-125 Bromochloromethane <0.005000.05000.0607 12175-125 Bromodichloromethane <0.005000.05000.0582 11675-125 Bromoform <0.005000.05000.0408 8265-135 Methyl bromide <0.005000.05000.0552 11065-135 MTBE <0.005000.05000.0530 10675-125 tert-Butylbenzene <0.005000.05000.0523 10575-125 Sec-Butylbenzene <0.005000.05000.0486 9775-125 n-Butylbenzene <0.005000.05000.0533 10762-125 Carbon Tetrachloride <0.005000.05000.0551 11060-133 Chlorobenzene <0.01000.05000.0399 8065-135 Chloroethane <0.005000.05000.0523 10574-125 Chloroform <0.01000.05000.0507 10165-135 Methyl Chloride <0.005000.05000.0538 10873-125 2-Chlorotoluene <0.005000.05000.0545 10974-125 4-Chlorotoluene <0.005000.05000.0531 10675-125 p-Cymene (p-Isopropyltoluene) <0.005000.05000.0590 11859-125 1,2-Dibromo-3-Chloropropane <0.005000.05000.0565 11373-125 Dibromochloromethane <0.005000.05000.0588 11873-125 1,2-Dibromoethane <0.005000.05000.0582 11669-127 Methylene bromide <0.005000.05000.0543 10975-125 1,2-Dichlorobenzene <0.005000.05000.0562 11275-125 1,3-Dichlorobenzene <0.005000.05000.0544 10975-125 1,4-Dichlorobenzene <0.005000.05000.0614 12365-135 Dichlorodifluoromethane <0.005000.05000.0600 12068-127 1,2-Dichloroethane <0.005000.05000.0504 10172-125 1,1-Dichloroethane <0.005000.05000.0444 8975-125 trans-1,2-dichloroethylene <0.005000.05000.0528 10675-125 cis-1,2-Dichloroethylene <0.005000.05000.0479 9659-172 1,1-Dichloroethene <0.005000.05000.0502 10075-125 2,2-Dichloropropane <0.005000.05000.0596 11975-125 1,3-Dichloropropane Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 14 of 23 Final Blank Spike Recovery Project Name: 17792.1 : Work Order # 432603:17792.1 Project ID Lab Batch #: 876565615127-1-BKSSolid Sample:Matrix: 12/07/201112/07/2011 Date Analyzed:Date Prepared:Analyst:CYE Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/kg1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.005000.05000.0559 11274-125 1,2-Dichloropropane <0.005000.05000.0606 12166-125 trans-1,3-dichloropropene <0.005000.05000.0557 11175-125 1,1-Dichloropropene <0.005000.05000.0592 11874-125 cis-1,3-Dichloropropene <0.005000.05000.0520 10475-125 Ethylbenzene <0.005000.05000.0533 10775-125 Hexachlorobutadiene <0.005000.05000.0520 10475-125 Isopropylbenzene <0.01000.05000.0548 11070-130 Naphthalene <0.02000.05000.0465 9375-125 Methylene Chloride <0.005000.05000.0533 10775-125 n-Propylbenzene <0.005000.05000.0553 11175-125 Styrene <0.005000.05000.0555 11172-125 1,1,1,2-Tetrachloroethane <0.005000.05000.0579 11674-125 1,1,2,2-Tetrachloroethane <0.005000.05000.0546 10971-125 Tetrachloroethylene <0.005000.05000.0546 10959-139 Toluene <0.005000.05000.0548 11075-135 1,2,4-Trichlorobenzene <0.005000.05000.0559 11275-137 1,2,3-Trichlorobenzene <0.005000.05000.0622 12475-127 1,1,2-Trichloroethane <0.005000.05000.0534 10775-125 1,1,1-Trichloroethane <0.005000.05000.0552 11062-137 Trichloroethylene <0.005000.05000.0537 10767-125 Trichlorofluoromethane <0.005000.05000.0599 12075-125 1,2,3-Trichloropropane <0.005000.05000.0515 10375-125 1,2,4-Trimethylbenzene <0.005000.05000.0541 10870-130 1,3,5-Trimethylbenzene <0.002000.05000.0484 9765-135 Vinyl Chloride <0.005000.05000.0513 10375-125 o-Xylene <0.01000.1000.103 10375-125 m,p-Xylenes Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 15 of 23 Final BS / BSD Recoveries Project Name:17792.1 Work Order #: 432603 Project ID:17792.1 Date Analyzed: DAT12/07/201112/07/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876434615037-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY ug/kg Units: Mercury by SW7471A BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Mercury <3.33167162 97167151 90785-11520 Date Analyzed: DAT12/07/201112/07/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876445615029-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/kg Units: Metals per ICP by SW846 6010B BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Arsenic <0.500100101 101100102 102185-11520 Barium 85-115 <0.50010097.5 9810098.0 98120 Cadmium 85-115 <0.250100102 102100103 103120 Chromium <0.250100101 101100101 101085-11520 Lead <0.600100102 102100104 104285-11520 Selenium <0.500100101 101100102 102185-11520 Silver <0.20010099.0 9910099.5 100185-11520 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 16 of 23 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432603 Lab Batch ID: 1Solid 876434 QC- Sample ID:432603-001 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:DAT 12/07/2011 Date Analyzed: Reporting Units:ug/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Mercury by SW7471A Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Mercury6.331501509615013988875-12520 Lab Batch ID: 1Solid 876445 QC- Sample ID:432603-001 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:DAT 12/07/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Metals per ICP by SW846 6010B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Arsenic <0.48597.190.89499.092.193175-12520 Barium93.897.119610599.0200107275-12520 Cadmium<0.24397.190.89499.093.194375-12520 Chromium14.097.11079699.011097375-12520 Lead11.697.11019299.010392275-12520 Selenium<0.48597.194.29799.097.098375-12520 Silver<0.19497.196.69999.099.0100275-12520 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 17 of 23 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432603 Lab Batch ID: 1Soil 876419 QC- Sample ID:432724-001 SBatch #:Matrix: 12/06/2011 Date Prepared:Analyst:JAH 12/06/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl TPH by Texas1005 Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] C6-C12 Gasoline Range Hydrocarbons<59.812001150961200118098375-12535 C12-C28 Diesel Range Hydrocarbons 20212001250871200120083475-12535 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 18 of 23 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432603 Lab Batch ID: 1Soil 876565 QC- Sample ID:432333-002 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:CYE 12/07/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Benzene<0.005400.05400.06061120.05400.0619115266-14225 Bromobenzene <0.005400.05400.06361180.05400.0625116275-12525 Bromochloromethane<0.005400.05400.06871270.05400.0641119773-12525X Bromodichloromethane<0.005400.05400.06811260.05400.0699129375-12525X Bromoform<0.005400.05400.06441190.05400.0615114575-12525 Methyl bromide<0.005400.05400.05991110.05400.0533991265-13525 MTBE<0.005400.05400.07051310.05400.0668124565-13525 tert-Butylbenzene<0.005400.05400.06341170.05400.0619115275-12525 Sec-Butylbenzene <0.005400.05400.06201150.05400.0598111475-12525 n-Butylbenzene<0.005400.05400.05711060.05400.0560104275-12525 Carbon Tetrachloride<0.005400.05400.06261160.05400.0626116062-12525 Chlorobenzene<0.005400.05400.06011110.05400.0594110160-13325 Chloroethane<0.01080.05400.05581030.05400.052096765-13525 Chloroform<0.005400.05400.06601220.05400.0634117474-12525 Methyl Chloride<0.01080.05400.06191150.05400.0565105965-13525 2-Chlorotoluene <0.005400.05400.06051120.05400.0603112073-12525 4-Chlorotoluene<0.005400.05400.06261160.05400.0608113374-12525 p-Cymene (p-Isopropyltoluene)<0.005400.05400.06321170.05400.0616114375-12525 1,2-Dibromo-3-Chloropropane<0.005400.05400.05831080.05400.0614114559-12525 Dibromochloromethane<0.005400.05400.06311170.05400.0623115173-12525 1,2-Dibromoethane<0.005400.05400.06041120.05400.0628116473-12525 Methylene bromide<0.005400.05400.06231150.05400.0665123769-12725 1,2-Dichlorobenzene <0.005400.05400.05971110.05400.0597111075-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 19 of 23 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432603 Lab Batch ID: 1Soil 876565 QC- Sample ID:432333-002 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:CYE 12/07/2011 Date Analyzed: Reporting Units:mg/kg Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] 1,3-Dichlorobenzene<0.005400.05400.06221150.05400.0624116075-12525 1,4-Dichlorobenzene <0.005400.05400.05991110.05400.0619115375-12525 Dichlorodifluoromethane<0.005400.05400.08321540.05400.07381371265-13525X 1,2-Dichloroethane<0.005400.05400.06331170.05400.0690128968-12725X 1,1-Dichloroethane<0.005400.05400.06551210.05400.0623115572-12525 trans-1,2-dichloroethylene<0.005400.05400.05961100.05400.0557103775-12525 cis-1,2-Dichloroethylene<0.005400.05400.06571220.05400.0629116475-12525 1,1-Dichloroethene<0.005400.05400.06601220.05400.05951101059-17225 2,2-Dichloropropane <0.005400.05400.06361180.05400.0585108875-12525 1,3-Dichloropropane<0.005400.05400.06461200.05400.0666123375-12525 1,2-Dichloropropane<0.005400.05400.05751060.05400.0602111574-12525 trans-1,3-dichloropropene<0.005400.05400.06201150.05400.0661122666-12525 1,1-Dichloropropene<0.005400.05400.06161140.05400.0641119475-12525 cis-1,3-Dichloropropene<0.005400.05400.06151140.05400.0633117374-12525 Ethylbenzene<0.005400.05400.05881090.05400.0582108175-12525 Hexachlorobutadiene <0.005400.05400.05401000.05400.051896475-12525 Naphthalene<0.01080.05400.0435810.05400.042278370-13025 Isopropylbenzene<0.005400.05400.06091130.05400.0589109375-12525 Methylene Chloride<0.02160.05400.06001110.05400.0569105575-12525 n-Propylbenzene<0.005400.05400.06061120.05400.0588109375-12525 Styrene<0.005400.05400.06191150.05400.0619115075-12525 1,1,1,2-Tetrachloroethane<0.005400.05400.06511210.05400.0639118272-12525 1,1,2,2-Tetrachloroethane <0.005400.05400.05741060.05400.0620115874-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 20 of 23 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432603 Lab Batch ID: 1Soil 876565 QC- Sample ID:432333-002 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:CYE 12/07/2011 Date Analyzed: Reporting Units:mg/kg Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Tetrachloroethylene<0.005400.05400.05961100.05400.0611113271-12525 Toluene <0.005400.05400.05961100.05400.0602111159-13925 1,2,4-Trichlorobenzene<0.005400.05400.0500930.05400.047187675-13525 1,2,3-Trichlorobenzene<0.005400.05400.0446830.05400.042879475-13725 1,1,2-Trichloroethane<0.005400.05400.06271160.05400.0656121575-12725 1,1,1-Trichloroethane<0.005400.05400.06971290.05400.0636118975-12525X Trichloroethylene<0.005400.05400.06251160.05400.0620115162-13725 Trichlorofluoromethane<0.005400.05400.07131320.05400.06401191167-12525X 1,2,3-Trichloropropane <0.005400.05400.06161140.05400.0640119475-12525 1,2,4-Trimethylbenzene<0.005400.05400.06171140.05400.0605112275-12525 1,3,5-Trimethylbenzene<0.005400.05400.06401190.05400.0618114370-13025 Vinyl Chloride<0.002160.05400.05971110.05400.05391001065-13525 o-Xylene<0.005400.05400.05791070.05400.0579107075-12525 m,p-Xylenes<0.01080.1080.1151060.1080.112104375-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 21 of 23 Final Page 22 of 23 Final XENCO Laboratories Prelogin/Nonconformance Report- Sample Log-In Client:Reed Engineering Group, Inc. Acceptable Temperature Range: 0 - 6 degC Air and Metal samples Acceptable Range: Ambient Date/ Time Received:12/02/2011 04:40:00 PM Temperature Measuring device used : Work Order #:432603 Sample Receipt Checklist Comments #1 *Temperature of cooler(s)?12.8 Yes #2 *Shipping container in good condition? Yes #3 *Samples received on ice? #4 *Custody Seals intact on shipping container/ cooler?Yes No #5 Custody Seals intact on sample bottles/ container? No #6 *Custody Seals Signed and dated for Containers/coolers No #7 *Chain of Custody present? #8 Sample instructions complete on Chain of Custody?Yes No #9 Any missing/extra samples? Yes #10 Chain of Custody signed when relinquished/ received? Yes #11 Chain of Custody agrees with sample label(s)? #12 Container label(s) legible and intact?Yes Yes #13 Sample matrix/ properties agree with Chain of Custody? Yes #14 Samples in proper container/ bottle? Yes #15 Samples properly preserved? #16 Sample container(s) intact?Yes Yes #17 Sufficient sample amount for indicated test(s)? Yes #18 All samples received within hold time? Yes #19 Subcontract of sample(s)?Xenco Houston #20 VOC samples have zero headspace (less than 1/4 inch bubble)?N/A N/A #21 <2 for all samples preserved with HNO3,HCL, H2SO4? N/A #22 >10 for all samples preserved with NaAsO2+NaOH, ZnAc+NaOH? * Must be completed for after-hours delivery of samples prior to placing in the refrigerator Analyst: PH Device/Lot#: NonConformance: Corrective Action Taken: Nonconformance Documentation Contact:Contacted by :DateTime : Checklist completed by: Date:12/03/2011 Angelica Martinez Checklist reviewed by: Date:12/02/2011 Page 23 of 23 Final Analytical Report 432605 for Reed Engineering Group, Inc. Project Manager: Chris McCaslin 17792.1 17792.1 23-DEC-11 Collected By: Client Celebrating 20 Years of commitment to excellence in Environmental Testing Services 9701 Harry Hines Blvd, Dallas, TX 75220 Ph:(214) 902-0300 Fax:(214) 351-9139 Xenco-Houston (EPA Lab code: TX00122): Texas (T104704215-10-6-TX), Arizona (AZ0765), Arkansas (08-039-0), Connecticut (PH-0102), Florida (E871002) Illinois (002082), Indiana (C-TX-02), Iowa (392), Kansas (E-10380), Kentucky (45), Louisiana (03054) New Hampshire (297408), New Jersey (TX007), New York (11763), Oklahoma (9218), Pennsylvania (68-03610) Rhode Island (LAO00312), USDA (S-44102) Xenco-Atlanta (EPA Lab Code: GA00046): Florida (E87429), North Carolina (483), South Carolina (98015), Utah (AALI1), West Virginia (362), Kentucky (85) Louisiana (04176), USDA (P330-07-00105) Xenco-Miami (EPA Lab code: FL01152): Florida (E86678), Maryland (330) Xenco-Tampa Mobile (EPA Lab code: FL01212): Florida (E84900) Xenco-Odessa (EPA Lab code: TX00158): Texas (T104704400-TX) Xenco-Dallas (EPA Lab code: TX01468): Texas (T104704295-TX) Xenco Phoenix (EPA Lab Code: AZ00901): Arizona(AZ0757) Xenco-Phoenix Mobile (EPA Lab code: AZ00901): Arizona (AZM757) Xenco Tucson (EPA Lab code:AZ000989): Arizona (AZ0758) Page 1 of 68 Final 1 Table of Contents Cover Page1 Cover Letter3 Sample ID Cross Reference4 Certificate of Analysis (Detailed Report)5 Holding Time Report25 Explanation of Qualifiers (Flags)31 Analytical Log32 Surrogate Recoveries_QC40 Blank Spike Recoveries46 Blank Spike - Blank Spike Duplicate Recoveries49 Matrix Spike - Matrix Spike Duplicate Recoveries54 Method Duplicate63 coc64 Page 2 of 68 Final 1 23-DEC-11 Chris McCaslin Project Manager: Reed Engineering Group, Inc. 2424 Stutz Drive, Suite 400 Dallas, TX 75235 432605 Reference: XENCO Report No: 17792.1 Project Address: TX Chris McCaslin : We are reporting to you the results of the analyses performed on the samples received under the project name referenced above and identified with the XENCO Report Number432605. All results being reported under this Report Number apply to the samples analyzed and properly identified with a Laboratory ID number. Subcontracted analyses are identified in this report with either the NELAC certification number of the subcontract lab in the analyst ID field, or the complete subcontracted report attached to this report. Unless otherwise noted in a Case Narrative, all data reported in this Analytical Report are in compliance with NELAC standards. Estimation of data uncertainty for this report is found in the quality control section of this report unless otherwise noted. Should insufficient sample be provided to the laboratory to meet the method and NELAC Matrix Duplicate and Matrix Spike requirements, then the data will be analyzed, evaluated and reported using all other available quality control measures. The validity and integrity of this report will remain intact as long as it is accompanied by this letter and reproduced in full, unless written approval is granted by XENCO Laboratories. This report will be filed for at least 5 years in our archives after which time it will be destroyed without further notice, unless otherwise arranged with you. The samples received, and described as recorded in Report No. 432605 will be filed for 60 days, and after that time they will be properly disposed without further notice, unless otherwise arranged with you. We reserve the right to return to you any unused samples, extracts or solutions related to them if we consider so necessary (e.g., samples identified as hazardous waste, sample sizes exceeding analytical standard practices, controlled substances under regulated protocols, etc). We thank you for selecting XENCO Laboratories to serve your analytical needs. If you have any questions concerning this report, please feel free to contact us at any time. Respectfully, Carlos Castro Managing Director, Texas Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Austin - Tampa - Miami - Atlanta - Corpus Christi - Latin America Page 3 of 68 Final 1 Sample Cross Reference 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample IdMatrixDate Collected Sample DepthLab Sample Id MW-5S12-02-11 08:393 - 5 432605-001 MW-4S12-02-11 09:13 N/A432605-002 MW-1W12-02-11 11:43432605-003 MW-2W12-02-11 14:05432605-004 MW-4W12-02-11 15:55432605-005 Page 4 of 68 Final 1 Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-5Matrix:SolidSample Depth:3 - 5 Lab Sample Id:432605-001Date Collected: Dec-02-11 08:39 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist:14.5 Tech:CYE Date Anal:Dec-13-11 19:34 Analyst:CYE Date Prep: Dec-13-11 14:18 Anal seq: 876915Prep seq: 615342 Subcontractor: SUB: TX104704295 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005840.000450mg/kgU 1 0.000525 Bromobenzene108-86-1U0.005000.005840.000259mg/kgU 1 0.000302 Bromochloromethane74-97-5U0.005000.005840.000645mg/kgU 1 0.000753 Bromodichloromethane 75-27-4U0.005000.005840.000364mg/kgU 1 0.000425 Bromoform75-25-2U0.005000.005840.000442mg/kgU 1 0.000516 Methyl bromide74-83-9U0.005000.005840.000811mg/kgU 1 0.000947 MTBE1634-04-4U0.005000.005840.000166mg/kgU 1 0.000194 tert-Butylbenzene98-06-6U0.005000.005840.000223mg/kgU 1 0.000260 Sec-Butylbenzene135-98-8U0.005000.005840.0000840mg/kgU 1 0.0000980 n-Butylbenzene104-51-8U0.005000.005840.000297mg/kgU 1 0.000347 Carbon Tetrachloride56-23-5U0.005000.005840.000161mg/kgU 1 0.000188 Chlorobenzene108-90-7U0.005000.005840.000290mg/kgU 1 0.000339 Chloroethane75-00-3U0.01000.01170.000757mg/kgU 1 0.000884 Chloroform67-66-3U0.005000.005840.000398mg/kgU 1 0.000465 Methyl Chloride74-87-3U0.01000.01170.000362mg/kgU 1 0.000423 2-Chlorotoluene95-49-8U0.005000.005840.000247mg/kgU 1 0.000288 4-Chlorotoluene106-43-4U0.005000.005840.000183mg/kgU 1 0.000214 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005840.000171mg/kgU 1 0.000200 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005840.00290mg/kgU 1 0.00339 Dibromochloromethane124-48-1U0.005000.005840.000532mg/kgU 1 0.000621 1,2-Dichlorobenzene95-50-1U0.005000.005840.000329mg/kgU 1 0.000384 1,3-Dichlorobenzene541-73-1U0.005000.005840.000270mg/kgU 1 0.000315 1,4-Dichlorobenzene106-46-7U0.005000.005840.00100mg/kgU 1 0.00117 Dichlorodifluoromethane75-71-8U0.005000.005840.000248mg/kgU 1 0.000289 1,2-Dichloroethane107-06-2U0.005000.005840.000523mg/kgU 1 0.000610 1,1-Dichloroethane75-34-3U0.005000.005840.000281mg/kgU 1 0.000328 trans-1,2-dichloroethylene156-60-5U0.005000.005840.000227mg/kgU 1 0.000265 cis-1,2-Dichloroethylene156-59-20.001030.005000.005840.000413mg/kgJ 1 0.000482 1,1-Dichloroethene75-35-4U0.005000.005840.000445mg/kgU 1 0.000519 2,2-Dichloropropane594-20-7U0.005000.005840.000380mg/kgU 1 0.000444 1,3-Dichloropropane142-28-9U0.005000.005840.000304mg/kgU 1 0.000355 1,2-Dichloropropane78-87-5U0.005000.005840.000348mg/kgU 1 0.000406 trans-1,3-dichloropropene10061-02-6U0.005000.005840.00108mg/kgU 1 0.00126 1,1-Dichloropropene563-58-6U0.005000.005840.000366mg/kgU 1 0.000427 cis-1,3-Dichloropropene10061-01-5U0.005000.005840.000315mg/kgU 1 0.000368 Ethylbenzene0.000362 100-41-40.005000.005840.000200mg/kgJ 1 0.000233 Hexachlorobutadiene87-68-3U0.005000.005840.000270mg/kgU 1 0.000315 Naphthalene91-20-30.002080.01000.01170.00100mg/kgJ 1 0.00117 Isopropylbenzene98-82-8U0.005000.005840.000228mg/kgU 1 0.000266 Methylene Chloride75-09-20.008870.02000.02330.000526mg/kgBJ 1 0.000614 n-Propylbenzene103-65-10.0003850.005000.005840.000233mg/kgJ 1 0.000272 Styrene100-42-5U0.005000.005840.000201mg/kgU 1 0.000235 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005840.000325mg/kgU 1 0.000379 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005840.000214mg/kgU 1 0.000250 Page 5 of 68 Final 1 Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-5Matrix:SolidSample Depth:3 - 5 Lab Sample Id:432605-001Date Collected: Dec-02-11 08:39 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist:14.5 Tech:CYE Date Anal:Dec-13-11 19:34 Analyst:CYE Date Prep: Dec-13-11 14:18 Anal seq: 876915Prep seq: 615342 Subcontractor: SUB: TX104704295 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Tetrachloroethylene127-18-40.0002570.005000.005840.000151mg/kgJ 1 0.000176 Toluene 108-88-30.002040.005000.005840.000321mg/kgJ 1 0.000375 1,2,4-Trichlorobenzene120-82-1U0.005000.005840.000348mg/kgU 1 0.000406 1,2,3-Trichlorobenzene 87-61-6U0.005000.005840.000347mg/kgU 1 0.000405 1,1,2-Trichloroethane79-00-5U0.005000.005840.000380mg/kgU 1 0.000444 1,1,1-Trichloroethane71-55-6U0.005000.005840.000276mg/kgU 1 0.000322 Trichloroethylene79-01-6U0.005000.005840.000440mg/kgU 1 0.000514 Trichlorofluoromethane75-69-4U0.005000.005840.000248mg/kgU 1 0.000289 1,2,3-Trichloropropane96-18-4U0.005000.005840.000384mg/kgU 1 0.000448 1,2,4-Trimethylbenzene0.000782 95-63-60.005000.005840.000142mg/kgJ 1 0.000166 1,3,5-Trimethylbenzene108-67-8U0.005000.005840.000131mg/kgU 1 0.000153 Vinyl Chloride75-01-4U0.002000.002330.000500mg/kgU 1 0.000584 o-Xylene0.000432 95-47-60.005000.005840.000206mg/kgJ 1 0.000240 m,p-Xylenes1330-20-70.001060.01000.01170.000321mg/kgJ 1 0.000375 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene12058 - 152% Dibromofluoromethane11074 - 126% 1,2-Dichloroethane-D411780 - 120% Toluene-D89073 - 132% Page 6 of 68 Final 1 Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-5Matrix:SolidSample Depth:3 - 5 Lab Sample Id:432605-001Date Collected: Dec-02-11 08:39 Date Received:Dec-02-11 17:12 Analytical Method:SVOA PAHs List by EPA 8270CPrep Method: 3550B % Moist:14.5 Tech:MCH Date Anal:Dec-20-11 15:32 Analyst:MCH Date Prep: Dec-14-11 14:15 Anal seq: 877310Prep seq: 615401 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Acenaphthene83-32-9U0.16748.70.0167mg/kgU 250 4.87 Acenaphthylene208-96-8U0.16748.70.0167mg/kgU 250 4.87 Anthracene120-12-7U0.16748.70.0167mg/kgU 250 4.87 Benzo(a)anthracene56-55-3U0.16748.70.0167mg/kgU 250 4.87 Benzo(a)pyrene50-32-8U0.16748.70.0167mg/kgU 250 4.87 Benzo(b)fluoranthene205-99-2U0.16748.70.0167mg/kgU 250 4.87 Benzo(g,h,i)perylene191-24-2U0.16748.70.0167mg/kgU 250 4.87 Benzo(k)fluoranthene207-08-9U0.16748.70.0167mg/kgU 250 4.87 Chrysene218-01-9U0.16748.70.0167mg/kgU 250 4.87 Dibenz(a,h)Anthracene53-70-3U0.16748.70.0167mg/kgU 250 4.87 Dibenzofuran132-64-9U0.16748.70.0833mg/kgU 250 24.4 Fluoranthene206-44-0U0.16748.70.0167mg/kgU 250 4.87 Fluorene86-73-7U0.16748.70.0167mg/kgU 250 4.87 Indeno(1,2,3-c,d)Pyrene193-39-5U0.16748.70.0167mg/kgU 250 4.87 Naphthalene91-20-3U0.16748.70.0167mg/kgU 250 4.87 Phenanthrene85-01-8U0.16748.70.0167mg/kgU 250 4.87 Pyrene129-00-0U0.16748.70.0167mg/kgU 250 4.87 Surrogate% RecLimitsUnitsFlag 2-Fluorobiphenyl1730 - 115%*** 2-Fluorophenol1625 - 121%*** Nitrobenzene-d51923 - 120%*** Phenol-d61424 - 113%*** Terphenyl-D141718 - 137%*** 2,4,6-Tribromophenol019 - 122%*** Metals per ICP by SW846 6010BPrep Method: 3050B % Moist: Tech:DAT Date Anal:Dec-07-11 10:58 Analyst:DAT Date Prep: Dec-07-11 06:30 Anal seq: 876445Prep seq: 615029 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-23.470.5000.4850.165mg/kg 1 0.160 Barium7440-39-384.50.5000.4850.165mg/kg 1 0.160 Cadmium7440-43-9BRL0.2500.2430.0750mg/kgU 1 0.0728 Chromium7440-47-39.610.2500.2430.0750mg/kg 1 0.0728 Lead7439-92-112.90.6000.5830.200mg/kg 1 0.194 Selenium2.64 7782-49-20.5000.4850.165mg/kg 1 0.160 Silver7440-22-4BRL0.2000.1940.0650mg/kgU 1 0.0631 Page 7 of 68 Final 1 Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-5Matrix:SolidSample Depth:3 - 5 Lab Sample Id:432605-001Date Collected: Dec-02-11 08:39 Date Received:Dec-02-11 17:12 Analytical Method:Mercury by SW7471APrep Method: % Moist: Tech:DAT Date Anal:Dec-07-11 11:47 Analyst:DAT Date Prep: Dec-07-11 08:00 Anal seq: 876434Prep seq: 615037 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-64.5910.02.873.30ug/kg 1 0.947 TPH by Texas1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-07-11 03:50 Analyst:JAH Date Prep: Dec-06-11 15:51 Anal seq: 876419Prep seq: 615049 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 472 C6-C12 Gasoline Range Hydrocarbons PHC61250.049.814.0mg/kg 1 13.9 C12-C28 Diesel Range Hydrocarbons422 PHCG102850.049.816.0mg/kg 1 15.9 C28-C35 Oil Range HydrocarbonsPHCG283573.550.049.812.9mg/kg 1 12.9 Total TPH 1005 PHC635968mg/kg Surrogate% RecLimitsUnitsFlag 1-Chlorooctane9670 - 130% o-Terphenyl9170 - 130% Percent Moisture% Moist:Prep Method: Tech:MAB Date Anal:Dec-15-11 10:00 Analyst:MAB Date Prep: Anal seq: 877097Prep seq: Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Percent MoistureTMOIST14.5% Page 8 of 68 Final 1 Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-4Matrix:SolidSample Depth: Lab Sample Id:432605-002Date Collected: Dec-02-11 09:13 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist:12.6 Tech:CYE Date Anal:Dec-13-11 19:57 Analyst:CYE Date Prep: Dec-13-11 14:18 Anal seq: 876915Prep seq: 615342 Subcontractor: SUB: TX104704295 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005720.000450mg/kgU 1 0.000515 Bromobenzene108-86-1U0.005000.005720.000259mg/kgU 1 0.000296 Bromochloromethane74-97-5U0.005000.005720.000645mg/kgU 1 0.000738 Bromodichloromethane 75-27-4U0.005000.005720.000364mg/kgU 1 0.000416 Bromoform75-25-2U0.005000.005720.000442mg/kgU 1 0.000506 Methyl bromide74-83-9U0.005000.005720.000811mg/kgU 1 0.000928 MTBE1634-04-4U0.005000.005720.000166mg/kgU 1 0.000190 tert-Butylbenzene98-06-6U0.005000.005720.000223mg/kgU 1 0.000255 Sec-Butylbenzene135-98-8U0.005000.005720.0000840mg/kgU 1 0.0000961 n-Butylbenzene104-51-8U0.005000.005720.000297mg/kgU 1 0.000340 Carbon Tetrachloride56-23-5U0.005000.005720.000161mg/kgU 1 0.000184 Chlorobenzene108-90-7U0.005000.005720.000290mg/kgU 1 0.000332 Chloroethane75-00-3U0.01000.01140.000757mg/kgU 1 0.000866 Chloroform67-66-3U0.005000.005720.000398mg/kgU 1 0.000455 Methyl Chloride74-87-3U0.01000.01140.000362mg/kgU 1 0.000414 2-Chlorotoluene95-49-8U0.005000.005720.000247mg/kgU 1 0.000283 4-Chlorotoluene106-43-4U0.005000.005720.000183mg/kgU 1 0.000209 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005720.000171mg/kgU 1 0.000196 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005720.00290mg/kgU 1 0.00332 Dibromochloromethane124-48-1U0.005000.005720.000532mg/kgU 1 0.000609 1,2-Dichlorobenzene95-50-1U0.005000.005720.000329mg/kgU 1 0.000376 1,3-Dichlorobenzene541-73-1U0.005000.005720.000270mg/kgU 1 0.000309 1,4-Dichlorobenzene106-46-7U0.005000.005720.00100mg/kgU 1 0.00114 Dichlorodifluoromethane75-71-8U0.005000.005720.000248mg/kgU 1 0.000284 1,2-Dichloroethane107-06-2U0.005000.005720.000523mg/kgU 1 0.000598 1,1-Dichloroethane75-34-3U0.005000.005720.000281mg/kgU 1 0.000322 trans-1,2-dichloroethylene156-60-5U0.005000.005720.000227mg/kgU 1 0.000260 cis-1,2-Dichloroethylene156-59-2U0.005000.005720.000413mg/kgU 1 0.000473 1,1-Dichloroethene75-35-4U0.005000.005720.000445mg/kgU 1 0.000509 2,2-Dichloropropane594-20-7U0.005000.005720.000380mg/kgU 1 0.000435 1,3-Dichloropropane142-28-9U0.005000.005720.000304mg/kgU 1 0.000348 1,2-Dichloropropane78-87-5U0.005000.005720.000348mg/kgU 1 0.000398 trans-1,3-dichloropropene10061-02-6U0.005000.005720.00108mg/kgU 1 0.00124 1,1-Dichloropropene563-58-6U0.005000.005720.000366mg/kgU 1 0.000419 cis-1,3-Dichloropropene10061-01-5U0.005000.005720.000315mg/kgU 1 0.000360 Ethylbenzene100-41-4U0.005000.005720.000200mg/kgU 1 0.000229 Hexachlorobutadiene87-68-3U0.005000.005720.000270mg/kgU 1 0.000309 Isopropylbenzene98-82-8U0.005000.005720.000228mg/kgU 1 0.000261 Naphthalene91-20-3U0.01000.01140.00100mg/kgU 1 0.00114 Methylene Chloride75-09-20.005230.02000.02290.000526mg/kgBJ 1 0.000602 n-Propylbenzene103-65-1U0.005000.005720.000233mg/kgU 1 0.000267 Styrene100-42-5U0.005000.005720.000201mg/kgU 1 0.000230 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005720.000325mg/kgU 1 0.000372 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005720.000214mg/kgU 1 0.000245 Page 9 of 68 Final 1 Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-4Matrix:SolidSample Depth: Lab Sample Id:432605-002Date Collected: Dec-02-11 09:13 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist:12.6 Tech:CYE Date Anal:Dec-13-11 19:57 Analyst:CYE Date Prep: Dec-13-11 14:18 Anal seq: 876915Prep seq: 615342 Subcontractor: SUB: TX104704295 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Tetrachloroethylene127-18-40.0002750.005000.005720.000151mg/kgJ 1 0.000173 Toluene108-88-30.0005610.005000.005720.000321mg/kgJ 1 0.000367 1,2,4-Trichlorobenzene120-82-1U0.005000.005720.000348mg/kgU 1 0.000398 1,2,3-Trichlorobenzene87-61-6U0.005000.005720.000347mg/kgU 1 0.000397 1,1,2-Trichloroethane79-00-5U0.005000.005720.000380mg/kgU 1 0.000435 1,1,1-Trichloroethane71-55-6U0.005000.005720.000276mg/kgU 1 0.000316 Trichloroethylene79-01-6U0.005000.005720.000440mg/kgU 1 0.000503 Trichlorofluoromethane75-69-4U0.005000.005720.000248mg/kgU 1 0.000284 1,2,3-Trichloropropane96-18-4U0.005000.005720.000384mg/kgU 1 0.000439 1,2,4-Trimethylbenzene95-63-6U0.005000.005720.000142mg/kgU 1 0.000162 1,3,5-Trimethylbenzene108-67-8U0.005000.005720.000131mg/kgU 1 0.000150 Vinyl Chloride75-01-4U0.002000.002290.000500mg/kgU 1 0.000572 o-Xylene95-47-6U0.005000.005720.000206mg/kgU 1 0.000236 m,p-Xylenes1330-20-7U0.01000.01140.000321mg/kgU 1 0.000367 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9958 - 152% Dibromofluoromethane10274 - 126% 1,2-Dichloroethane-D410580 - 120% Toluene-D89873 - 132% Metals per ICP by SW846 6010B% Moist:Prep Method: 3050B Tech:DAT Date Anal:Dec-07-11 11:00 Analyst:DAT Date Prep: Dec-07-11 06:30 Anal seq: 876445Prep seq: 615029 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-2BRL0.5000.4720.165mg/kgU 1 0.156 Barium97.2 7440-39-30.5000.4720.165mg/kg 1 0.156 Cadmium7440-43-9BRL0.2500.2360.0750mg/kgU 1 0.0708 Chromium12.4 7440-47-30.2500.2360.0750mg/kg 1 0.0708 Lead9.48 7439-92-10.6000.5660.200mg/kg 1 0.189 Selenium7782-49-2BRL0.5000.4720.165mg/kgU 1 0.156 Silver7440-22-4BRL0.2000.1890.0650mg/kgU 1 0.0613 Page 10 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-4Matrix:SolidSample Depth: Lab Sample Id:432605-002Date Collected: Dec-02-11 09:13 Date Received:Dec-02-11 17:12 Analytical Method:Mercury by SW7471APrep Method: % Moist: Tech:DAT Date Anal:Dec-07-11 11:48 Analyst:DAT Date Prep: Dec-07-11 08:00 Anal seq: 876434Prep seq: 615037 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-64.8410.03.023.30ug/kg 1 0.998 TPH by Texas1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-07-11 04:13 Analyst:JAH Date Prep: Dec-06-11 15:54 Anal seq: 876419Prep seq: 615049 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612BRL50.049.914.0mg/kgU 1 13.9 C12-C28 Diesel Range HydrocarbonsPHCG1028BRL50.049.916.0mg/kgU 1 16.0 C28-C35 Oil Range HydrocarbonsPHCG2835BRL50.049.912.9mg/kgU 1 12.9 Total TPH 1005PHC635BRLmg/kgU Surrogate% RecLimitsUnitsFlag 1-Chlorooctane9370 - 130% o-Terphenyl9370 - 130% Percent Moisture% Moist:Prep Method: Tech:MAB Date Anal:Dec-15-11 10:00 Analyst:MAB Date Prep: Anal seq: 877097Prep seq: Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Percent MoistureTMOIST12.6% Page 11 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-1Matrix:WaterSample Depth: Lab Sample Id:432605-003Date Collected: Dec-02-11 11:43 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 17:37 Analyst:CYE Date Prep: Dec-07-11 14:31 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000260mg/LU 1 0.000260 Bromobenzene108-86-1U0.005000.005000.000390mg/LU 1 0.000390 Bromochloromethane74-97-5U0.005000.005000.000480mg/LU 1 0.000480 Bromodichloromethane 75-27-4U0.005000.005000.000420mg/LU 1 0.000420 Bromoform75-25-2U0.005000.005000.000340mg/LU 1 0.000340 Methyl bromide74-83-9U0.005000.005000.000870mg/LU 1 0.000870 MTBE1634-04-4U0.005000.005000.000430mg/LUH 1 0.000430 n-Butylbenzene104-51-8U0.005000.005000.000190mg/LU 1 0.000190 Sec-Butylbenzene135-98-8U0.005000.005000.000120mg/LU 1 0.000120 tert-Butylbenzene98-06-6U0.005000.005000.000200mg/LU 1 0.000200 Carbon Tetrachloride56-23-5U0.005000.005000.000140mg/LU 1 0.000140 Chlorobenzene108-90-7U0.005000.005000.000270mg/LU 1 0.000270 Chloroethane75-00-3U0.01000.01000.000206mg/LU 1 0.000206 Chloroform67-66-3U0.005000.005000.000620mg/LU 1 0.000620 Methyl Chloride74-87-3U0.01000.01000.000420mg/LU 1 0.000420 2-Chlorotoluene95-49-8U0.005000.005000.000300mg/LU 1 0.000300 4-Chlorotoluene106-43-4U0.005000.005000.000250mg/LU 1 0.000250 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000230mg/LUH 1 0.000230 Dibromochloromethane124-48-1U0.005000.005000.000350mg/LU 1 0.000350 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00143mg/LU 1 0.00143 1,2-Dibromoethane106-93-4U0.005000.005000.000360mg/LU 1 0.000360 Methylene bromide74-95-3U0.005000.005000.000470mg/LU 1 0.000470 1,2-Dichlorobenzene95-50-1U0.005000.005000.000240mg/LU 1 0.000240 1,3-Dichlorobenzene541-73-1U0.005000.005000.000190mg/LU 1 0.000190 1,4-Dichlorobenzene106-46-7U0.005000.005000.000360mg/LU 1 0.000360 Dichlorodifluoromethane75-71-8U0.005000.005000.000310mg/LUH 1 0.000310 1,1-Dichloroethane75-34-3U0.005000.005000.000310mg/LU 1 0.000310 1,2-Dichloroethane107-06-2U0.005000.005000.000270mg/LU 1 0.000270 1,1-Dichloroethene75-35-4U0.005000.005000.000330mg/LU 1 0.000330 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000350mg/LU 1 0.000350 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000340mg/LU 1 0.000340 1,2-Dichloropropane78-87-5U0.005000.005000.000370mg/LU 1 0.000370 1,3-Dichloropropane142-28-9U0.005000.005000.000330mg/LU 1 0.000330 2,2-Dichloropropane594-20-7U0.005000.005000.000260mg/LUH 1 0.000260 1,1-Dichloropropene563-58-6U0.005000.005000.000410mg/LU 1 0.000410 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000250mg/LU 1 0.000250 trans-1,3-dichloropropene10061-02-6U0.005000.005000.000300mg/LU 1 0.000300 Ethylbenzene100-41-4U0.005000.005000.0000800mg/LU 1 0.0000800 Hexachlorobutadiene87-68-3U0.005000.005000.000560mg/LU 1 0.000560 Isopropylbenzene98-82-8U0.005000.005000.000250mg/LU 1 0.000250 Methylene Chloride75-09-2U0.005000.005000.000750mg/LU 1 0.000750 Naphthalene91-20-3U0.01000.01000.000430mg/LU 1 0.000430 n-Propylbenzene103-65-1U0.005000.005000.000180mg/LU 1 0.000180 Styrene100-42-5U0.005000.005000.000140mg/LU 1 0.000140 Page 12 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-1Matrix:WaterSample Depth: Lab Sample Id:432605-003Date Collected: Dec-02-11 11:43 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 17:37 Analyst:CYE Date Prep: Dec-07-11 14:31 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000280mg/LU 1 0.000280 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000420mg/LU 1 0.000420 Tetrachloroethylene127-18-4U0.005000.005000.000590mg/LU 1 0.000590 Toluene108-88-3U0.005000.005000.000490mg/LU 1 0.000490 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.000260mg/LU 1 0.000260 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000440mg/LU 1 0.000440 1,1,1-Trichloroethane71-55-6U0.005000.005000.000310mg/LU 1 0.000310 1,1,2-Trichloroethane79-00-5U0.005000.005000.000410mg/LU 1 0.000410 Trichloroethylene79-01-6U0.005000.005000.000390mg/LU 1 0.000390 Trichlorofluoromethane75-69-4U0.005000.005000.000330mg/LU 1 0.000330 1,2,3-Trichloropropane96-18-4U0.005000.005000.000590mg/LU 1 0.000590 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000140mg/LU 1 0.000140 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000250mg/LU 1 0.000250 o-Xylene95-47-6U0.005000.005000.000310mg/LU 1 0.000310 m,p-Xylenes1330-20-7U0.01000.01000.000470mg/LU 1 0.000470 Vinyl Chloride75-01-4U0.002000.002000.000310mg/LU 1 0.000310 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9774 - 124% Dibromofluoromethane10875 - 131% 1,2-Dichloroethane-D411463 - 144% Toluene-D89780 - 117% TPH by Texas1005Prep Method: 1005 % Moist: Tech:JAH Date Anal:Dec-07-11 07:37 Analyst:JAH Date Prep: Dec-06-11 16:51 Anal seq: 876426Prep seq: 615057 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612BRL5.004.690.990mg/LU 1 0.928 C12-C28 Diesel Range HydrocarbonsPHCG1028BRL5.004.691.42mg/LU 1 1.33 C28-C35 Oil Range HydrocarbonsPHCG2835BRL5.004.691.50mg/LU 1 1.41 Total TPH 1005PHC635BRLmg/LU Surrogate% RecLimitsUnitsFlag 1-Chlorooctane9370 - 130% o-Terphenyl8870 - 130% Page 13 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-2Matrix:WaterSample Depth: Lab Sample Id:432605-004Date Collected: Dec-02-11 14:05 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 18:00 Analyst:CYE Date Prep: Dec-07-11 14:32 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000260mg/LU 1 0.000260 Bromobenzene108-86-1U0.005000.005000.000390mg/LU 1 0.000390 Bromochloromethane74-97-5U0.005000.005000.000480mg/LU 1 0.000480 Bromodichloromethane 75-27-4U0.005000.005000.000420mg/LU 1 0.000420 Bromoform75-25-2U0.005000.005000.000340mg/LU 1 0.000340 Methyl bromide74-83-9U0.005000.005000.000870mg/LU 1 0.000870 MTBE1634-04-4U0.005000.005000.000430mg/LUH 1 0.000430 n-Butylbenzene104-51-8U0.005000.005000.000190mg/LU 1 0.000190 Sec-Butylbenzene135-98-8U0.005000.005000.000120mg/LU 1 0.000120 tert-Butylbenzene98-06-6U0.005000.005000.000200mg/LU 1 0.000200 Carbon Tetrachloride56-23-5U0.005000.005000.000140mg/LU 1 0.000140 Chlorobenzene108-90-7U0.005000.005000.000270mg/LU 1 0.000270 Chloroethane75-00-3U0.01000.01000.000206mg/LU 1 0.000206 Chloroform67-66-3U0.005000.005000.000620mg/LU 1 0.000620 Methyl Chloride74-87-3U0.01000.01000.000420mg/LU 1 0.000420 2-Chlorotoluene95-49-8U0.005000.005000.000300mg/LU 1 0.000300 4-Chlorotoluene106-43-4U0.005000.005000.000250mg/LU 1 0.000250 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000230mg/LUH 1 0.000230 Dibromochloromethane124-48-1U0.005000.005000.000350mg/LU 1 0.000350 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00143mg/LU 1 0.00143 1,2-Dibromoethane106-93-4U0.005000.005000.000360mg/LU 1 0.000360 Methylene bromide74-95-3U0.005000.005000.000470mg/LU 1 0.000470 1,2-Dichlorobenzene95-50-1U0.005000.005000.000240mg/LU 1 0.000240 1,3-Dichlorobenzene541-73-1U0.005000.005000.000190mg/LU 1 0.000190 1,4-Dichlorobenzene106-46-7U0.005000.005000.000360mg/LU 1 0.000360 Dichlorodifluoromethane75-71-8U0.005000.005000.000310mg/LUH 1 0.000310 1,1-Dichloroethane75-34-3U0.005000.005000.000310mg/LU 1 0.000310 1,2-Dichloroethane107-06-2U0.005000.005000.000270mg/LU 1 0.000270 1,1-Dichloroethene75-35-4U0.005000.005000.000330mg/LU 1 0.000330 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000350mg/LU 1 0.000350 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000340mg/LU 1 0.000340 1,2-Dichloropropane78-87-5U0.005000.005000.000370mg/LU 1 0.000370 1,3-Dichloropropane142-28-9U0.005000.005000.000330mg/LU 1 0.000330 2,2-Dichloropropane594-20-7U0.005000.005000.000260mg/LUH 1 0.000260 1,1-Dichloropropene563-58-6U0.005000.005000.000410mg/LU 1 0.000410 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000250mg/LU 1 0.000250 trans-1,3-dichloropropene10061-02-6U0.005000.005000.000300mg/LU 1 0.000300 Ethylbenzene100-41-4U0.005000.005000.0000800mg/LU 1 0.0000800 Hexachlorobutadiene87-68-3U0.005000.005000.000560mg/LU 1 0.000560 Isopropylbenzene98-82-8U0.005000.005000.000250mg/LU 1 0.000250 Methylene Chloride75-09-2U0.005000.005000.000750mg/LU 1 0.000750 Naphthalene91-20-3U0.01000.01000.000430mg/LU 1 0.000430 n-Propylbenzene103-65-1U0.005000.005000.000180mg/LU 1 0.000180 Styrene100-42-5U0.005000.005000.000140mg/LU 1 0.000140 Page 14 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-2Matrix:WaterSample Depth: Lab Sample Id:432605-004Date Collected: Dec-02-11 14:05 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 18:00 Analyst:CYE Date Prep: Dec-07-11 14:32 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000280mg/LU 1 0.000280 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000420mg/LU 1 0.000420 Tetrachloroethylene127-18-4U0.005000.005000.000590mg/LU 1 0.000590 Toluene108-88-3U0.005000.005000.000490mg/LU 1 0.000490 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.000260mg/LU 1 0.000260 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000440mg/LU 1 0.000440 1,1,1-Trichloroethane71-55-6U0.005000.005000.000310mg/LU 1 0.000310 1,1,2-Trichloroethane79-00-5U0.005000.005000.000410mg/LU 1 0.000410 Trichloroethylene79-01-6U0.005000.005000.000390mg/LU 1 0.000390 Trichlorofluoromethane75-69-4U0.005000.005000.000330mg/LU 1 0.000330 1,2,3-Trichloropropane96-18-4U0.005000.005000.000590mg/LU 1 0.000590 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000140mg/LU 1 0.000140 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000250mg/LU 1 0.000250 o-Xylene95-47-6U0.005000.005000.000310mg/LU 1 0.000310 m,p-Xylenes1330-20-7U0.01000.01000.000470mg/LU 1 0.000470 Vinyl Chloride75-01-4U0.002000.002000.000310mg/LU 1 0.000310 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene11174 - 124% Dibromofluoromethane10475 - 131% 1,2-Dichloroethane-D411163 - 144% Toluene-D810180 - 117% TPH by Texas1005Prep Method: 1005 % Moist: Tech:JAH Date Anal:Dec-07-11 08:00 Analyst:JAH Date Prep: Dec-06-11 16:54 Anal seq: 876426Prep seq: 615057 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612BRL5.004.500.990mg/LU 1 0.892 C12-C28 Diesel Range HydrocarbonsPHCG1028BRL5.004.501.42mg/LU 1 1.28 C28-C35 Oil Range HydrocarbonsPHCG2835BRL5.004.501.50mg/LU 1 1.35 Total TPH 1005PHC635BRLmg/LU Surrogate% RecLimitsUnitsFlag 1-Chlorooctane9770 - 130% o-Terphenyl9670 - 130% Page 15 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-4Matrix:WaterSample Depth: Lab Sample Id:432605-005Date Collected: Dec-02-11 15:55 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 18:22 Analyst:CYE Date Prep: Dec-07-11 14:33 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000260mg/LU 1 0.000260 Bromobenzene108-86-1U0.005000.005000.000390mg/LU 1 0.000390 Bromochloromethane74-97-5U0.005000.005000.000480mg/LU 1 0.000480 Bromodichloromethane 75-27-4U0.005000.005000.000420mg/LU 1 0.000420 Bromoform75-25-2U0.005000.005000.000340mg/LU 1 0.000340 Methyl bromide74-83-9U0.005000.005000.000870mg/LU 1 0.000870 MTBE1634-04-4U0.005000.005000.000430mg/LUH 1 0.000430 n-Butylbenzene104-51-8U0.005000.005000.000190mg/LU 1 0.000190 Sec-Butylbenzene135-98-8U0.005000.005000.000120mg/LU 1 0.000120 tert-Butylbenzene98-06-6U0.005000.005000.000200mg/LU 1 0.000200 Carbon Tetrachloride56-23-5U0.005000.005000.000140mg/LU 1 0.000140 Chlorobenzene108-90-7U0.005000.005000.000270mg/LU 1 0.000270 Chloroethane75-00-3U0.01000.01000.000206mg/LU 1 0.000206 Chloroform67-66-3U0.005000.005000.000620mg/LU 1 0.000620 Methyl Chloride74-87-3U0.01000.01000.000420mg/LU 1 0.000420 2-Chlorotoluene95-49-8U0.005000.005000.000300mg/LU 1 0.000300 4-Chlorotoluene106-43-4U0.005000.005000.000250mg/LU 1 0.000250 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000230mg/LUH 1 0.000230 Dibromochloromethane124-48-1U0.005000.005000.000350mg/LU 1 0.000350 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00143mg/LU 1 0.00143 1,2-Dibromoethane106-93-4U0.005000.005000.000360mg/LU 1 0.000360 Methylene bromide74-95-3U0.005000.005000.000470mg/LU 1 0.000470 1,2-Dichlorobenzene95-50-1U0.005000.005000.000240mg/LU 1 0.000240 1,3-Dichlorobenzene541-73-1U0.005000.005000.000190mg/LU 1 0.000190 1,4-Dichlorobenzene106-46-7U0.005000.005000.000360mg/LU 1 0.000360 Dichlorodifluoromethane75-71-8U0.005000.005000.000310mg/LUH 1 0.000310 1,1-Dichloroethane75-34-3U0.005000.005000.000310mg/LU 1 0.000310 1,2-Dichloroethane107-06-2U0.005000.005000.000270mg/LU 1 0.000270 1,1-Dichloroethene75-35-4U0.005000.005000.000330mg/LU 1 0.000330 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000350mg/LU 1 0.000350 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000340mg/LU 1 0.000340 1,2-Dichloropropane78-87-5U0.005000.005000.000370mg/LU 1 0.000370 1,3-Dichloropropane142-28-9U0.005000.005000.000330mg/LU 1 0.000330 2,2-Dichloropropane594-20-7U0.005000.005000.000260mg/LUH 1 0.000260 1,1-Dichloropropene563-58-6U0.005000.005000.000410mg/LU 1 0.000410 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000250mg/LU 1 0.000250 trans-1,3-dichloropropene10061-02-6U0.005000.005000.000300mg/LU 1 0.000300 Ethylbenzene100-41-4U0.005000.005000.0000800mg/LU 1 0.0000800 Hexachlorobutadiene87-68-3U0.005000.005000.000560mg/LU 1 0.000560 Isopropylbenzene98-82-8U0.005000.005000.000250mg/LU 1 0.000250 Methylene Chloride75-09-2U0.005000.005000.000750mg/LU 1 0.000750 Naphthalene91-20-3U0.01000.01000.000430mg/LU 1 0.000430 n-Propylbenzene103-65-1U0.005000.005000.000180mg/LU 1 0.000180 Styrene100-42-5U0.005000.005000.000140mg/LU 1 0.000140 Page 16 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:MW-4Matrix:WaterSample Depth: Lab Sample Id:432605-005Date Collected: Dec-02-11 15:55 Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 18:22 Analyst:CYE Date Prep: Dec-07-11 14:33 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000280mg/LU 1 0.000280 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000420mg/LU 1 0.000420 Tetrachloroethylene127-18-4U0.005000.005000.000590mg/LU 1 0.000590 Toluene108-88-3U0.005000.005000.000490mg/LU 1 0.000490 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.000260mg/LU 1 0.000260 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000440mg/LU 1 0.000440 1,1,1-Trichloroethane71-55-6U0.005000.005000.000310mg/LU 1 0.000310 1,1,2-Trichloroethane79-00-5U0.005000.005000.000410mg/LU 1 0.000410 Trichloroethylene79-01-6U0.005000.005000.000390mg/LU 1 0.000390 Trichlorofluoromethane75-69-4U0.005000.005000.000330mg/LU 1 0.000330 1,2,3-Trichloropropane96-18-4U0.005000.005000.000590mg/LU 1 0.000590 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000140mg/LU 1 0.000140 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000250mg/LU 1 0.000250 o-Xylene95-47-6U0.005000.005000.000310mg/LU 1 0.000310 m,p-Xylenes1330-20-7U0.01000.01000.000470mg/LU 1 0.000470 Vinyl Chloride75-01-4U0.002000.002000.000310mg/LU 1 0.000310 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene10274 - 124% Dibromofluoromethane10175 - 131% 1,2-Dichloroethane-D410863 - 144% Toluene-D89480 - 117% TPH by Texas1005Prep Method: 1005 % Moist: Tech:JAH Date Anal:Dec-07-11 08:23 Analyst:JAH Date Prep: Dec-06-11 16:57 Anal seq: 876426Prep seq: 615057 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612BRL5.004.570.990mg/LU 1 0.904 C12-C28 Diesel Range HydrocarbonsPHCG1028BRL5.004.571.42mg/LU 1 1.30 C28-C35 Oil Range HydrocarbonsPHCG2835BRL5.004.571.50mg/LU 1 1.37 Total TPH 1005PHC635BRLmg/LU Surrogate% RecLimitsUnitsFlag 1-Chlorooctane9870 - 130% o-Terphenyl9870 - 130% Page 17 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615029-1-BLKMatrix:SolidSample Depth: Lab Sample Id:615029-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:Metals per ICP by SW846 6010BPrep Method: 3050B % Moist: Tech:DAT Date Anal:Dec-07-11 10:15 Analyst:DAT Date Prep: Dec-07-11 06:30 Anal seq: 876445Prep seq: 615029 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-2BRL0.5000.5000.165mg/kgU 1 0.165 Barium7440-39-3BRL0.5000.5000.165mg/kgU 1 0.165 Cadmium7440-43-9BRL0.2500.2500.0750mg/kgU 1 0.0750 0.0750 Chromium7440-47-3BRL0.2500.250mg/kgU 1 0.0750 Lead7439-92-1BRL0.6000.6000.200mg/kgU 1 0.200 Selenium7782-49-2BRL0.5000.5000.165mg/kgU 1 0.165 Silver7440-22-4BRL0.2000.2000.0650mg/kgU 1 0.0650 Sample Id:615037-1-BLKMatrix:SolidSample Depth: Lab Sample Id:615037-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:Mercury by SW7471A% Moist:Prep Method: Tech:DAT Date Anal:Dec-07-11 11:31 Analyst:DAT Date Prep: Dec-07-11 08:00 Anal seq: 876434Prep seq: 615037 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-6BRL10.03.333.30ug/kgU 1 1.10 Sample Id:615049-1-BLKMatrix:SolidSample Depth: Lab Sample Id:615049-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:TPH by Texas1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-06-11 20:59 Analyst:JAH Date Prep: Dec-06-11 15:00 Anal seq: 876419Prep seq: 615049 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612BRL50.050.014.0mg/kgU 1 14.0 C12-C28 Diesel Range HydrocarbonsPHCG1028BRL50.050.016.0mg/kgU 1 16.0 C28-C35 Oil Range HydrocarbonsPHCG2835BRL50.050.012.9mg/kgU 1 12.9 Surrogate% RecLimitsUnitsFlag 1-Chlorooctane9870 - 130% o-Terphenyl9470 - 130% Page 18 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615057-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615057-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:TPH by Texas1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-07-11 04:36 Analyst:JAH Date Prep: Dec-06-11 16:30 Anal seq: 876426Prep seq: 615057 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612BRL5.005.000.990mg/LU 1 0.990 C12-C28 Diesel Range HydrocarbonsPHCG1028BRL5.005.001.42mg/LU 1 1.42 C28-C35 Oil Range HydrocarbonsPHCG2835BRL5.005.001.50mg/LU 1 1.50 Surrogate% RecLimitsUnitsFlag 1-Chlorooctane10370 - 130% o-Terphenyl10370 - 130% Page 19 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615075-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615075-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 12:51 Analyst:CYE Date Prep: Dec-07-11 10:05 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000260mg/LU 1 0.000260 Bromobenzene108-86-1U0.005000.005000.000390mg/LU 1 0.000390 Bromochloromethane74-97-5U0.005000.005000.000480mg/LU 1 0.000480 Bromodichloromethane 75-27-4U0.005000.005000.000420mg/LU 1 0.000420 Bromoform75-25-2U0.005000.005000.000340mg/LU 1 0.000340 Methyl bromide74-83-9U0.005000.005000.000870mg/LU 1 0.000870 MTBE1634-04-4U0.005000.005000.000430mg/LU 1 0.000430 n-Butylbenzene104-51-8U0.005000.005000.000190mg/LU 1 0.000190 Sec-Butylbenzene135-98-8U0.005000.005000.000120mg/LU 1 0.000120 tert-Butylbenzene98-06-6U0.005000.005000.000200mg/LU 1 0.000200 Carbon Tetrachloride56-23-5U0.005000.005000.000140mg/LU 1 0.000140 Chlorobenzene108-90-7U0.005000.005000.000270mg/LU 1 0.000270 Chloroethane75-00-3U0.01000.01000.000206mg/LU 1 0.000206 Chloroform67-66-3U0.005000.005000.000620mg/LU 1 0.000620 Methyl Chloride74-87-3U0.01000.01000.000420mg/LU 1 0.000420 2-Chlorotoluene95-49-8U0.005000.005000.000300mg/LU 1 0.000300 4-Chlorotoluene106-43-4U0.005000.005000.000250mg/LU 1 0.000250 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000230mg/LU 1 0.000230 Dibromochloromethane124-48-1U0.005000.005000.000350mg/LU 1 0.000350 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00143mg/LU 1 0.00143 1,2-Dibromoethane106-93-4U0.005000.005000.000360mg/LU 1 0.000360 Methylene bromide74-95-3U0.005000.005000.000470mg/LU 1 0.000470 1,2-Dichlorobenzene95-50-1U0.005000.005000.000240mg/LU 1 0.000240 1,3-Dichlorobenzene541-73-1U0.005000.005000.000190mg/LU 1 0.000190 1,4-Dichlorobenzene106-46-7U0.005000.005000.000360mg/LU 1 0.000360 Dichlorodifluoromethane75-71-8U0.005000.005000.000310mg/LU 1 0.000310 1,1-Dichloroethane75-34-3U0.005000.005000.000310mg/LU 1 0.000310 1,2-Dichloroethane107-06-2U0.005000.005000.000270mg/LU 1 0.000270 1,1-Dichloroethene75-35-4U0.005000.005000.000330mg/LU 1 0.000330 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000350mg/LU 1 0.000350 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000340mg/LU 1 0.000340 1,2-Dichloropropane78-87-5U0.005000.005000.000370mg/LU 1 0.000370 1,3-Dichloropropane142-28-9U0.005000.005000.000330mg/LU 1 0.000330 2,2-Dichloropropane594-20-7U0.005000.005000.000260mg/LU 1 0.000260 1,1-Dichloropropene563-58-6U0.005000.005000.000410mg/LU 1 0.000410 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000250mg/LU 1 0.000250 trans-1,3-dichloropropene10061-02-6U0.005000.005000.000300mg/LU 1 0.000300 Ethylbenzene100-41-4U0.005000.005000.0000800mg/LU 1 0.0000800 Hexachlorobutadiene87-68-3U0.005000.005000.000560mg/LU 1 0.000560 Isopropylbenzene98-82-8U0.005000.005000.000250mg/LU 1 0.000250 Methylene Chloride75-09-2U0.005000.005000.000750mg/LU 1 0.000750 Naphthalene91-20-3U0.01000.01000.000430mg/LU 1 0.000430 n-Propylbenzene103-65-1U0.005000.005000.000180mg/LU 1 0.000180 Styrene100-42-5U0.005000.005000.000140mg/LU 1 0.000140 Page 20 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615075-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615075-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-07-11 12:51 Analyst:CYE Date Prep: Dec-07-11 10:05 Anal seq: 876464Prep seq: 615075 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000280mg/LU 1 0.000280 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000420mg/LU 1 0.000420 Tetrachloroethylene127-18-4U0.005000.005000.000590mg/LU 1 0.000590 Toluene 108-88-3U0.005000.005000.000490mg/LU 1 0.000490 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.000260mg/LU 1 0.000260 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000440mg/LU 1 0.000440 1,1,1-Trichloroethane71-55-6U0.005000.005000.000310mg/LU 1 0.000310 1,1,2-Trichloroethane79-00-5U0.005000.005000.000410mg/LU 1 0.000410 Trichloroethylene79-01-6U0.005000.005000.000390mg/LU 1 0.000390 Trichlorofluoromethane75-69-4U0.005000.005000.000330mg/LU 1 0.000330 1,2,3-Trichloropropane96-18-4U0.005000.005000.000590mg/LU 1 0.000590 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000140mg/LU 1 0.000140 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000250mg/LU 1 0.000250 o-Xylene95-47-6U0.005000.005000.000310mg/LU 1 0.000310 m,p-Xylenes1330-20-7U0.01000.01000.000470mg/LU 1 0.000470 Vinyl Chloride75-01-4U0.002000.002000.000310mg/LU 1 0.000310 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene10574 - 124% Dibromofluoromethane9775 - 131% 1,2-Dichloroethane-D410163 - 144% Toluene-D810480 - 117% Page 21 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615342-1-BLKMatrix:SolidSample Depth: Lab Sample Id:615342-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-13-11 14:21 Analyst:CYE Date Prep: Dec-13-11 10:26 Anal seq: 876915Prep seq: 615342 Subcontractor: SUB: TX104704295 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000450mg/kgU 1 0.000450 Bromobenzene108-86-1U0.005000.005000.000259mg/kgU 1 0.000259 Bromochloromethane74-97-5U0.005000.005000.000645mg/kgU 1 0.000645 Bromodichloromethane 75-27-4U0.005000.005000.000364mg/kgU 1 0.000364 Bromoform75-25-2U0.005000.005000.000442mg/kgU 1 0.000442 Methyl bromide74-83-9U0.005000.005000.000811mg/kgU 1 0.000811 MTBE1634-04-4U0.005000.005000.000166mg/kgU 1 0.000166 tert-Butylbenzene98-06-6U0.005000.005000.000223mg/kgU 1 0.000223 Sec-Butylbenzene135-98-8U0.005000.005000.0000840mg/kgU 1 0.0000840 n-Butylbenzene104-51-8U0.005000.005000.000297mg/kgU 1 0.000297 Carbon Tetrachloride56-23-5U0.005000.005000.000161mg/kgU 1 0.000161 Chlorobenzene108-90-7U0.005000.005000.000290mg/kgU 1 0.000290 Chloroethane75-00-3U0.01000.01000.000757mg/kgU 1 0.000757 Chloroform67-66-3U0.005000.005000.000398mg/kgU 1 0.000398 Methyl Chloride74-87-3U0.01000.01000.000362mg/kgU 1 0.000362 2-Chlorotoluene95-49-8U0.005000.005000.000247mg/kgU 1 0.000247 4-Chlorotoluene106-43-4U0.005000.005000.000183mg/kgU 1 0.000183 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000171mg/kgU 1 0.000171 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00290mg/kgU 1 0.00290 Dibromochloromethane124-48-1U0.005000.005000.000532mg/kgU 1 0.000532 1,2-Dichlorobenzene95-50-1U0.005000.005000.000329mg/kgU 1 0.000329 1,3-Dichlorobenzene541-73-1U0.005000.005000.000270mg/kgU 1 0.000270 1,4-Dichlorobenzene106-46-7U0.005000.005000.00100mg/kgU 1 0.00100 Dichlorodifluoromethane75-71-8U0.005000.005000.000248mg/kgU 1 0.000248 1,2-Dichloroethane107-06-2U0.005000.005000.000523mg/kgU 1 0.000523 1,1-Dichloroethane75-34-3U0.005000.005000.000281mg/kgU 1 0.000281 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000227mg/kgU 1 0.000227 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000413mg/kgU 1 0.000413 1,1-Dichloroethene75-35-4U0.005000.005000.000445mg/kgU 1 0.000445 2,2-Dichloropropane594-20-7U0.005000.005000.000380mg/kgU 1 0.000380 1,3-Dichloropropane142-28-9U0.005000.005000.000304mg/kgU 1 0.000304 1,2-Dichloropropane78-87-5U0.005000.005000.000348mg/kgU 1 0.000348 trans-1,3-dichloropropene10061-02-6U0.005000.005000.00108mg/kgU 1 0.00108 1,1-Dichloropropene563-58-6U0.005000.005000.000366mg/kgU 1 0.000366 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000315mg/kgU 1 0.000315 Ethylbenzene100-41-4U0.005000.005000.000200mg/kgU 1 0.000200 Hexachlorobutadiene87-68-3U0.005000.005000.000270mg/kgU 1 0.000270 Isopropylbenzene98-82-8U0.005000.005000.000228mg/kgU 1 0.000228 Naphthalene91-20-3U0.01000.01000.00100mg/kgU 1 0.00100 Methylene Chloride75-09-20.01420.02000.02000.000526mg/kgJ 1 0.000526 n-Propylbenzene103-65-1U0.005000.005000.000233mg/kgU 1 0.000233 Styrene100-42-5U0.005000.005000.000201mg/kgU 1 0.000201 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000325mg/kgU 1 0.000325 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000214mg/kgU 1 0.000214 Page 22 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615342-1-BLKMatrix:SolidSample Depth: Lab Sample Id:615342-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-13-11 14:21 Analyst:CYE Date Prep: Dec-13-11 10:26 Anal seq: 876915Prep seq: 615342 Subcontractor: SUB: TX104704295 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Tetrachloroethylene127-18-4U0.005000.005000.000151mg/kgU 1 0.000151 Toluene108-88-3U0.005000.005000.000321mg/kgU 1 0.000321 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000348mg/kgU 1 0.000348 1,2,3-Trichlorobenzene 87-61-6U0.005000.005000.000347mg/kgU 1 0.000347 1,1,2-Trichloroethane79-00-5U0.005000.005000.000380mg/kgU 1 0.000380 1,1,1-Trichloroethane71-55-6U0.005000.005000.000276mg/kgU 1 0.000276 Trichloroethylene79-01-6U0.005000.005000.000440mg/kgU 1 0.000440 Trichlorofluoromethane75-69-4U0.005000.005000.000248mg/kgU 1 0.000248 1,2,3-Trichloropropane96-18-4U0.005000.005000.000384mg/kgU 1 0.000384 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000142mg/kgU 1 0.000142 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000131mg/kgU 1 0.000131 Vinyl Chloride75-01-4U0.002000.002000.000500mg/kgU 1 0.000500 o-Xylene95-47-6U0.005000.005000.000206mg/kgU 1 0.000206 m,p-Xylenes1330-20-7U0.01000.01000.000321mg/kgU 1 0.000321 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9758 - 152% Dibromofluoromethane9974 - 126% 1,2-Dichloroethane-D410180 - 120% Toluene-D89873 - 132% Page 23 of 68 Final Certificate of Analytical Results 432605 Reed Engineering Group, Inc., Dallas, TX 17792.1 Sample Id:615401-1-BLKMatrix:SolidSample Depth: Lab Sample Id:615401-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:SVOA PAHs List by EPA 8270CPrep Method: 3550B % Moist: Tech:WEW Date Anal:Dec-16-11 23:52 Analyst:WEW Date Prep: Dec-14-11 12:30 Anal seq: 877310Prep seq: 615401 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Acenaphthene83-32-9U0.03330.03330.0167mg/kgU 1 0.0166 Acenaphthylene208-96-8U0.03330.03330.0167mg/kgU 1 0.0166 Anthracene120-12-7U0.03330.03330.0167mg/kgU 1 0.0166 Benzo(a)anthracene56-55-3U0.03330.03330.0167mg/kgU 1 0.0166 Benzo(a)pyrene50-32-8U0.03330.03330.0167mg/kgU 1 0.0166 Benzo(b)fluoranthene205-99-2U0.03330.03330.0167mg/kgU 1 0.0166 Benzo(g,h,i)perylene191-24-2U0.03330.03330.0167mg/kgU 1 0.0166 Benzo(k)fluoranthene207-08-9U0.03330.03330.0167mg/kgU 1 0.0166 Chrysene218-01-9U0.03330.03330.0167mg/kgU 1 0.0166 Dibenz(a,h)Anthracene53-70-3U0.03330.03330.0167mg/kgU 1 0.0166 Dibenzofuran132-64-9U0.1670.1660.0833mg/kgU 1 0.0832 Fluoranthene206-44-0U0.03330.03330.0167mg/kgU 1 0.0166 Fluorene86-73-7U0.03330.03330.0167mg/kgU 1 0.0166 Indeno(1,2,3-c,d)Pyrene193-39-5U0.03330.03330.0167mg/kgU 1 0.0166 Naphthalene91-20-3U0.03330.03330.0167mg/kgU 1 0.0166 Phenanthrene85-01-8U0.03330.03330.0167mg/kgU 1 0.0166 Pyrene129-00-0U0.03330.03330.0167mg/kgU 1 0.0166 Surrogate% RecLimitsUnitsFlag 2-Fluorobiphenyl9430 - 115% 2-Fluorophenol8025 - 121% Nitrobenzene-d58923 - 120% Phenol-d68124 - 113% Terphenyl-D1411218 - 137% 2,4,6-Tribromophenol6419 - 122% Sample Id:877097-1-BLKMatrix:SolidSample Depth: Lab Sample Id:877097-1-BLKDate Collected: Date Received:Dec-02-11 17:12 Analytical Method:Percent Moisture% Moist:Prep Method: Tech:MAB Date Anal:Dec-15-11 10:00 Analyst:MAB Date Prep: Anal seq: 877097Prep seq: Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Percent MoistureTMOISTU%U Page 24 of 68 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Percent Moisture Client : Reed Engineering Group, Inc. Work Order #:432605 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 2, 2011Dec. 2, 2011Dec.15, 20114513P MW-5 Dec. 2, 2011Dec. 2, 2011Dec.15, 20114513P MW-4 Page 25 of 68 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Metals per ICP by SW846 6010B Client : Reed Engineering Group, Inc. Work Order #:432605 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 2, 2011Dec. 2, 2011Dec. 7, 20111805Dec.7, 20111800P MW-5 Dec. 2, 2011Dec. 2, 2011Dec. 7, 20111805Dec.7, 20111800P MW-4 Page 26 of 68 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Mercury by SW7471A Client : Reed Engineering Group, Inc. Work Order #:432605 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 2, 2011Dec. 2, 2011Dec. 7, 2011285Dec.7, 2011280P MW-4 Dec. 2, 2011Dec. 2, 2011Dec. 7, 2011285Dec.7, 2011280P MW-5 Page 27 of 68 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :VOAs by SW-846 8260B Client : Reed Engineering Group, Inc. Work Order #:432605 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 2, 2011Dec. 2, 2011Dec.7, 2011145P MW-4 Dec. 2, 2011Dec. 2, 2011Dec.7, 2011145P MW-1 Dec. 2, 2011Dec. 2, 2011Dec.7, 2011145P MW-2 Dec. 2, 2011Dec. 2, 2011Dec.13, 20111411P MW-5 Dec. 2, 2011Dec. 2, 2011Dec.13, 20111411P MW-4 Page 28 of 68 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :SVOA PAHs List by EPA 8270C Client : Reed Engineering Group, Inc. Work Order #:432605 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 2, 2011Dec. 2, 2011Dec. 14, 20111412Dec.20, 2011406P MW-5 Page 29 of 68 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :TPH by Texas1005 Client : Reed Engineering Group, Inc. Work Order #:432605 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 2, 2011Dec. 2, 2011Dec. 6, 2011144Dec.7, 2011141P MW-2 Dec. 2, 2011Dec. 2, 2011Dec. 6, 2011144Dec.7, 2011141P MW-5 Dec. 2, 2011Dec. 2, 2011Dec. 6, 2011144Dec.7, 2011141P MW-4 Dec. 2, 2011Dec. 2, 2011Dec. 6, 2011144Dec.7, 2011141P MW-4 Dec. 2, 2011Dec. 2, 2011Dec. 6, 2011144Dec.7, 2011141P MW-1 F = These samples were analyzed outside the recommended holding time. P = Samples analyzed within the recommended holding time. Page 30 of 68 Final Flagging Criteria X In our quality control review of the data a QC deficiency was observed and flagged as noted. MS/MSD recoveries were found to be outside of the laboratory control limits due to possible matrix /chemical interference, or a concentration of target analyte high enough to affect the recovery of the spike concentration. This condition could also affect the relative percent difference in the MS/MSD. B A target analyte or common laboratory contaminant was identified in the method blank. Its presence indicates possible field or laboratory contamination. D The sample(s) were diluted due to targets detected over the highest point of the calibration curve, or due to matrix interference. Dilution factors are included in the final results. The result is from a diluted sample. E The data exceeds the upper calibration limit; therefore, the concentration is reported as estimated. F RPD exceeded lab control limits. J The target analyte was positively identified below the quantiation limit and above the detection limit. U Analyte was not detected. L The LCS data for this analytical batch was reported below the laboratory control limits for this analyte. The department supervisor and QA Director reviewed data. The samples were either reanalyzed or flagged as estimated concentrations. H The LCS data for this analytical batch was reported above the laboratory control limits. Supporting QC Data were reviewed by the Department Supervisor and QA Director. Data were determined to be valid for reporting. K Sample analyzed outside of recommended hold time. JN A combination of the "N" and the "J" qualifier. The analysis indicates that the analyte is "tentatively identified" and the associated numerical value may not be consistent with the amount actually present in the environmental sample. * Surrogate recovered outside laboratory control limit. BRL Below Reporting Limit. RL Reporting Limit MDLSDLLOD Method Detection LimitSample Detection LimitLimit of Detection PQLMQLLOQ Practical Quantitation Limit Method Quantitation LimitLimit of Quantitation DL Method Detection Limit NC Non-Calculable + Outside XENCO's scope of NELAC Accreditation. ^NELAC or State program does not offer Accreditation at this time. Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Atlanta - Midland/Odessa - Tampa/Lakeland - Miami - Phoenix - Latin America Phone Fax 4143 Greenbriar Dr, Stafford, TX 77477 (281) 240-4200 (281) 240-4280 9701 Harry Hines Blvd , Dallas, TX 75220 (214) 902 0300 (214) 351-9139 5332 Blackberry Drive, San Antonio TX 78238 (210) 509-3334 (210) 509-3335 2505 North Falkenburg Rd, Tampa, FL 33619 (813) 620-2000 (813) 620-2033 5757 NW 158th St, Miami Lakes, FL 33014 (305) 823-8500 (305) 823-8555 12600 West I-20 East, Odessa, TX 79765 (432) 563-1800 (432) 563-1713 6017 Financial Drive, Norcross, GA 30071 (770) 449-8800 (770) 449-5477 3725 E. Atlanta Ave, Phoenix, AZ 85040 (602) 437-0330 Page 31 of 68 Final Analytical Log Analytical Method:TPH by Texas1005Batch #:876419 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-4 432605-002 SMP MW-5 432605-001 SMP 432724-001 S MS 432724-001 SD MSD 615049-1-BKS BKS 615049-1-BLK BLK Page 32 of 68 Final Analytical Log Analytical Method:TPH by Texas1005Batch #:876426 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-1 432605-003 SMP MW-2 432605-004 SMP MW-4 432605-005 SMP 615057-1-BKS BKS 615057-1-BLK BLK 615057-1-BSD BSD Page 33 of 68 Final Analytical Log Analytical Method:Mercury by SW7471ABatch #:876434 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-4 432605-002 SMP MW-5 432605-001 SMP 432603-001 S MS 432603-001 SD MSD 615037-1-BKS BKS 615037-1-BLK BLK 615037-1-BSD BSD Page 34 of 68 Final Analytical Log Analytical Method:Metals per ICP by SW846 6010BBatch #:876445 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-4 432605-002 SMP MW-5 432605-001 SMP 432603-001 S MS 432603-001 SD MSD 615029-1-BKS BKS 615029-1-BLK BLK 615029-1-BSD BSD Page 35 of 68 Final Analytical Log Analytical Method:VOAs by SW-846 8260BBatch #:876464 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-1 432605-003 SMP MW-2 432605-004 SMP MW-4 432605-005 SMP 432528-008 S MS 432528-008 SD MSD 615075-1-BKS BKS 615075-1-BLK BLK Page 36 of 68 Final Analytical Log Analytical Method:VOAs by SW-846 8260BBatch #:876915 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-4 432605-002 SMP MW-5 432605-001 SMP 432701-001 S MS 432701-001 SD MSD 615342-1-BKS BKS 615342-1-BLK BLK 615342-1-BSD BSD Page 37 of 68 Final Analytical Log Analytical Method:Percent MoistureBatch #:877097 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-4 432605-002 SMP MW-5 432605-001 SMP 432605-001 D MD 433313-009 D MD 877097-1-BLK BLK Page 38 of 68 Final Analytical Log Analytical Method:SVOA PAHs List by EPA 8270CBatch #:877310 Project Name:17792.1Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:432605 Client Sample IdLab Sample IdQC Types MW-5 432605-001 SMP 433216-002 S MS 433216-002 SD MSD 615401-1-BKS BKS 615401-1-BLK BLK Page 39 of 68 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432605,17792.1 877310615401-1-BLK / BLK1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/16/11 23:52 Units: AmountTrueControl SVOA PAHs List by EPA 8270C FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 2-Fluorobiphenyl 1.561.669430-115 2-Fluorophenol 1.331.668025-121 Nitrobenzene-d5 1.481.668923-120 Phenol-d6 1.351.668124-113 Terphenyl-D14 1.861.6611218-137 2,4,6-Tribromophenol 6419-122 1.061.66 877310615401-1-BKS / BKS1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/17/11 00:16 Units: AmountControl True SVOA PAHs List by EPA 8270C FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 2-Fluorobiphenyl 1.871.6611330-115 2-Fluorophenol 9425-121 1.561.66 Nitrobenzene-d5 1.761.6610623-120 Phenol-d6 1.601.669624-113 Terphenyl-D14 1.991.6612018-137 2,4,6-Tribromophenol 1.581.669519-122 877310433216-002 S / MS1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/17/11 01:26 Units: AmountTrueControl SVOA PAHs List by EPA 8270C FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 2-Fluorobiphenyl 1.511.679030-115 2-Fluorophenol 1.211.677225-121 Nitrobenzene-d5 1.411.678423-120 Phenol-d6 7724-113 1.291.67 Terphenyl-D14 1.681.6710118-137 2,4,6-Tribromophenol 1.401.678419-122 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 40 of 68 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432605,17792.1 877310433216-002 SD / MSD1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/17/11 01:49 Units: AmountTrueControl SVOA PAHs List by EPA 8270C FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 2-Fluorobiphenyl 1.571.669530-115 2-Fluorophenol 1.241.667525-121 Nitrobenzene-d5 1.461.668823-120 Phenol-d6 1.341.668124-113 Terphenyl-D14 1.781.6610718-137 2,4,6-Tribromophenol 8719-122 1.441.66 876419615049-1-BLK / BLK1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 20:59 Units: AmountControl True TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 98.11009870-130 o-Terphenyl 9470-130 46.850.0 876419615049-1-BKS / BKS1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 21:22 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A]%R %R [B] Analytes[D] 1-Chlorooctane 9770-130 96.7100 o-Terphenyl 40.750.08170-130 876419432724-001 S / MS1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 22:08 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 90.799.69170-130 o-Terphenyl 39.849.88070-130 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 41 of 68 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432605,17792.1 876419432724-001 SD / MSD1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/06/11 22:31 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 93.799.89470-130 o-Terphenyl 44.549.98970-130 876426615057-1-BLK / BLK1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 04:36 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 10.310.010370-130 o-Terphenyl 5.145.0010370-130 876426615057-1-BKS / BKS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 04:59 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 1-Chlorooctane 10.910.010970-130 o-Terphenyl 4.935.009970-130 876426615057-1-BSD / BSD1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 05:21 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 1-Chlorooctane 10.910.010970-130 o-Terphenyl 5.335.0010770-130 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 42 of 68 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432605,17792.1 876915615342-1-BKS / BKS1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/13/11 12:53 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04990.050010058-152 Dibromofluoromethane 0.05110.050010274-126 1,2-Dichloroethane-D4 0.05230.050010580-120 Toluene-D8 0.04890.05009873-132 876915615342-1-BSD / BSD1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/13/11 13:15 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04800.05009658-152 Dibromofluoromethane 0.04880.05009874-126 1,2-Dichloroethane-D4 0.05140.050010380-120 Toluene-D8 0.05160.050010373-132 876915615342-1-BLK / BLK1Solid Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/13/11 14:21 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04830.05009758-152 Dibromofluoromethane 0.04930.05009974-126 1,2-Dichloroethane-D4 0.05030.050010180-120 Toluene-D8 0.04890.05009873-132 876915432701-001 S / MS1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/13/11 15:11 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 4-Bromofluorobenzene 0.05750.050011558-152 Dibromofluoromethane 0.05810.050011674-126 1,2-Dichloroethane-D4 0.06380.050012880-120** Toluene-D8 0.04210.05008473-132 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 43 of 68 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432605,17792.1 876915432701-001 SD / MSD1Soil Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/kg12/13/11 15:33 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05730.050011558-152 Dibromofluoromethane 0.05780.050011674-126 1,2-Dichloroethane-D4 0.06030.050012180-120** Toluene-D8 0.04420.05008873-132 876464615075-1-BKS / BKS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 11:44 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05050.050010174-124 Dibromofluoromethane 0.05220.050010475-131 1,2-Dichloroethane-D4 0.05200.050010463-144 Toluene-D8 0.05090.050010280-117 876464615075-1-BLK / BLK1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 12:51 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05250.050010574-124 Dibromofluoromethane 0.04860.05009775-131 1,2-Dichloroethane-D4 0.05040.050010163-144 Toluene-D8 0.05190.050010480-117 876464432528-008 S / MS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 13:56 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 4-Bromofluorobenzene 0.05220.050010474-124 Dibromofluoromethane 0.04960.05009975-131 1,2-Dichloroethane-D4 0.05000.050010063-144 Toluene-D8 0.05140.050010380-117 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 44 of 68 Final Form 2 - Surrogate Recoveries 17792.1 Project Name: Work Orders :: Project ID 432605,17792.1 876464432528-008 SD / MSD1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/07/11 14:19 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.05130.050010374-124 Dibromofluoromethane 0.04840.05009775-131 1,2-Dichloroethane-D4 0.04990.050010063-144 Toluene-D8 0.05330.050010780-117 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 45 of 68 Final Blank Spike Recovery Project Name: 17792.1 : Work Order # 432605:17792.1 Project ID Lab Batch #: 877310615401-1-BKSSolid Sample:Matrix: 12/16/201112/14/2011 Analyst:WEW Date Analyzed:Date Prepared: Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/kg1 Batch #: BlankSpikeBlankBlankControl SVOA PAHs List by EPA 8270C ResultAddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.01661.661.71 10363-123 Acenaphthene <0.01661.661.71 10363-122 Acenaphthylene <0.01661.661.57 9562-126 Anthracene <0.01661.661.69 10261-127 Benzo(a)anthracene <0.01661.661.61 9764-127 Benzo(a)pyrene <0.01661.661.56 9461-130 Benzo(b)fluoranthene <0.01661.661.36 8255-125 Benzo(g,h,i)perylene <0.01661.661.56 9464-123 Benzo(k)fluoranthene <0.01661.661.73 10461-127 Chrysene <0.01661.661.59 9658-133 Dibenz(a,h)Anthracene <0.08321.661.66 10065-135 Dibenzofuran <0.01661.661.60 9662-128 Fluoranthene <0.01661.661.67 10165-123 Fluorene <0.01661.661.61 9759-132 Indeno(1,2,3-c,d)Pyrene <0.01661.661.56 9460-122 Naphthalene <0.01661.661.46 8862-127 Phenanthrene <0.01661.661.72 10460-127 Pyrene Lab Batch #: 876419615049-1-BKSSolid Sample:Matrix: 12/06/201112/06/2011 Date Analyzed:Date Prepared:Analyst:JAH Reporting Units: BLANK /BLANK SPIKE RECOVERY STUDY mg/kg1 Batch #: BlankSpikeBlankBlankControl TPH by Texas1005 ResultAddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <50.010001010 10175-125 C6-C12 Gasoline Range Hydrocarbons <50.01000891 8975-125 C12-C28 Diesel Range Hydrocarbons Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 46 of 68 Final Blank Spike Recovery Project Name: 17792.1 : Work Order # 432605:17792.1 Project ID Lab Batch #: 876464615075-1-BKSWater Sample:Matrix: 12/07/201112/07/2011 Date Analyzed:Date Prepared:Analyst:CYE Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.0002600.05000.0609 12266-142 Benzene <0.0003900.05000.0548 11075-125 Bromobenzene <0.0004800.05000.0607 12173-125 Bromochloromethane <0.0004200.05000.0557 11175-125 Bromodichloromethane <0.0003400.05000.0508 10275-125 Bromoform <0.0008700.05000.0528 10670-130 Methyl bromide <0.0004300.05000.0722 14465-135H MTBE <0.0001900.05000.0611 12275-125 n-Butylbenzene <0.0001200.05000.0623 12575-125 Sec-Butylbenzene <0.0002000.05000.0606 12175-125 tert-Butylbenzene <0.0001400.05000.0561 11262-125 Carbon Tetrachloride <0.0002700.05000.0546 10960-133 Chlorobenzene <0.0002060.05000.0490 9870-130 Chloroethane <0.0006200.05000.0539 10874-125 Chloroform <0.0004200.05000.0624 12570-130 Methyl Chloride <0.0003000.05000.0588 11873-125 2-Chlorotoluene <0.0002500.05000.0570 11474-125 4-Chlorotoluene <0.0002300.05000.0628 12675-125H p-Cymene (p-Isopropyltoluene) <0.0003500.05000.0521 10473-125 Dibromochloromethane <0.001430.05000.0474 9559-125 1,2-Dibromo-3-Chloropropane <0.0003600.05000.0545 10973-125 1,2-Dibromoethane <0.0004700.05000.0531 10669-127 Methylene bromide <0.0002400.05000.0570 11475-125 1,2-Dichlorobenzene <0.0001900.05000.0577 11575-125 1,3-Dichlorobenzene <0.0003600.05000.0566 11375-125 1,4-Dichlorobenzene <0.0003100.05000.0686 13770-130H Dichlorodifluoromethane <0.0003100.05000.0598 12072-125 1,1-Dichloroethane <0.0002700.05000.0465 9368-127 1,2-Dichloroethane <0.0003300.05000.0711 14259-172 1,1-Dichloroethene <0.0003500.05000.0626 12575-125 cis-1,2-Dichloroethylene <0.0003400.05000.0615 12375-125 trans-1,2-dichloroethylene <0.0003700.05000.0573 11574-125 1,2-Dichloropropane <0.0003300.05000.0559 11275-125 1,3-Dichloropropane Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 47 of 68 Final Blank Spike Recovery Project Name: 17792.1 : Work Order # 432605:17792.1 Project ID Lab Batch #: 876464615075-1-BKSWater Sample:Matrix: 12/07/201112/07/2011 Date Analyzed:Date Prepared:Analyst:CYE Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.0002600.05000.0655 13175-125H 2,2-Dichloropropane <0.0004100.05000.0582 11675-125 1,1-Dichloropropene <0.0002500.05000.0505 10174-125 cis-1,3-Dichloropropene <0.0003000.05000.0444 8966-125 trans-1,3-dichloropropene <0.00008000.05000.0577 11575-125 Ethylbenzene <0.0005600.05000.0541 10875-125 Hexachlorobutadiene <0.0002500.05000.0589 11875-125 Isopropylbenzene <0.0007500.05000.0579 11675-125 Methylene Chloride <0.0004300.05000.0534 10775-125 Naphthalene <0.0001800.05000.0613 12375-125 n-Propylbenzene <0.0001400.05000.0575 11575-125 Styrene <0.0002800.05000.0568 11472-125 1,1,1,2-Tetrachloroethane <0.0004200.05000.0558 11274-125 1,1,2,2-Tetrachloroethane <0.0005900.05000.0506 10171-125 Tetrachloroethylene <0.0004900.05000.0575 11559-139 Toluene <0.0002600.05000.0564 11375-137 1,2,3-Trichlorobenzene <0.0004400.05000.0544 10975-135 1,2,4-Trichlorobenzene <0.0003100.05000.0568 11475-125 1,1,1-Trichloroethane <0.0004100.05000.0535 10775-127 1,1,2-Trichloroethane <0.0003900.05000.0549 11062-137 Trichloroethylene <0.0003300.05000.0608 12267-125 Trichlorofluoromethane <0.0005900.05000.0548 11075-125 1,2,3-Trichloropropane <0.0001400.05000.0627 12575-125 1,2,4-Trimethylbenzene <0.0002500.05000.0617 12370-125 1,3,5-Trimethylbenzene <0.0003100.05000.0559 11275-125 o-Xylene <0.0004700.1000.121 12175-125 m,p-Xylenes <0.0003100.05000.0572 11475-125 Vinyl Chloride Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 48 of 68 Final BS / BSD Recoveries Project Name:17792.1 Work Order #: 432605 Project ID:17792.1 Date Analyzed: DAT12/07/201112/07/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876434615037-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY ug/kg Units: Mercury by SW7471A BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Mercury <3.33167162 97167151 90785-11520 Date Analyzed: DAT12/07/201112/07/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876445615029-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/kg Units: Metals per ICP by SW846 6010B BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Arsenic <0.500100101 101100102 102185-11520 Barium 85-115 <0.50010097.5 9810098.0 98120 Cadmium 85-115 <0.250100102 102100103 103120 Chromium <0.250100101 101100101 101085-11520 Lead <0.600100102 102100104 104285-11520 Selenium <0.500100101 101100102 102185-11520 Silver <0.20010099.0 9910099.5 100185-11520 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 49 of 68 Final BS / BSD Recoveries Project Name:17792.1 Work Order #: 432605 Project ID:17792.1 Date Analyzed: JAH12/06/201112/07/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 876426615057-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/L Units: TPH by Texas1005 BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes C6-C12 Gasoline Range Hydrocarbons <5.00100113 113100113 113075-12520 C12-C28 Diesel Range Hydrocarbons <5.00100101 10110095.9 96575-12520 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 50 of 68 Final BS / BSD Recoveries Project Name:17792.1 Work Order #: 432605 Project ID:17792.1 Date Analyzed: CYE12/13/201112/13/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876915615342-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/kg Units: VOAs by SW-846 8260B BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Benzene <0.0004500.05000.0472 940.05000.0508 102766-14225 Bromobenzene <0.0002590.05000.0469 940.05000.0469 94075-12525 Bromochloromethane <0.0006450.05000.0461 920.05000.0476 95373-12525 Bromodichloromethane <0.0003640.05000.0480 960.05000.0509 102675-12525 Bromoform 75-125 <0.0004420.05000.0479 960.05000.0453 91625 Methyl bromide 65-135 <0.0008110.05000.0383 770.05000.0433 871225 MTBE <0.0001660.05000.0495 990.05000.0505 101265-13525 tert-Butylbenzene <0.0002230.05000.0459 920.05000.0493 99775-12525 Sec-Butylbenzene <0.00008400.05000.0466 930.05000.0510 102975-12525 n-Butylbenzene <0.0002970.05000.0445 890.05000.0490 981075-12525 Carbon Tetrachloride <0.0001610.05000.0386 770.05000.0453 911662-12525 Chlorobenzene 60-133 <0.0002900.05000.0470 940.05000.0481 96225 Chloroethane 65-135 <0.0007570.05000.0406 810.05000.0456 911225 Chloroform <0.0003980.05000.0451 900.05000.0460 92274-12525 Methyl Chloride <0.0003620.05000.0438 880.05000.0491 981165-13525 2-Chlorotoluene <0.0002470.05000.0459 920.05000.0478 96473-12525 4-Chlorotoluene <0.0001830.05000.0480 960.05000.0479 96074-12525 p-Cymene (p-Isopropyltoluene) <0.0001710.05000.0460 920.05000.0499 100875-12525 1,2-Dibromo-3-Chloropropane 59-125 <0.002900.05000.0475 950.05000.0423 851225 Dibromochloromethane 73-125 <0.0005320.05000.0474 950.05000.0457 91425 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 51 of 68 Final BS / BSD Recoveries Project Name:17792.1 Work Order #: 432605 Project ID:17792.1 Date Analyzed: CYE12/13/201112/13/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876915615342-1-BKS1 mg/kg Units: VOAs by SW-846 8260B BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes 1,2-Dichlorobenzene <0.0003290.05000.0479 960.05000.0488 98275-12525 1,3-Dichlorobenzene <0.0002700.05000.0487 970.05000.0495 99275-12525 1,4-Dichlorobenzene <0.001000.05000.0476 950.05000.0479 96175-12525 Dichlorodifluoromethane <0.0002480.05000.0507 1010.05000.0541 108665-13525 1,2-Dichloroethane 68-127 <0.0005230.05000.0437 870.05000.0455 91425 1,1-Dichloroethane 72-125 <0.0002810.05000.0475 950.05000.0498 100525 trans-1,2-dichloroethylene <0.0002270.05000.0415 830.05000.0436 87575-12525 cis-1,2-Dichloroethylene <0.0004130.05000.0481 960.05000.0505 101575-12525 1,1-Dichloroethene <0.0004450.05000.0424 850.05000.0481 961359-17225 2,2-Dichloropropane <0.0003800.05000.0427 850.05000.0466 93975-12525 1,3-Dichloropropane <0.0003040.05000.0526 1050.05000.0506 101475-12525 1,2-Dichloropropane 74-125 <0.0003480.05000.0481 960.05000.0488 98125 trans-1,3-dichloropropene 66-125 <0.001080.05000.0496 990.05000.0471 94525 1,1-Dichloropropene <0.0003660.05000.0431 860.05000.0471 94975-12525 cis-1,3-Dichloropropene <0.0003150.05000.0484 970.05000.0473 95274-12525 Ethylbenzene <0.0002000.05000.0441 880.05000.0453 91375-12525 Hexachlorobutadiene <0.0002700.05000.0477 950.05000.0556 1111575-12525 Isopropylbenzene <0.0002280.05000.0440 880.05000.0469 94675-12525 Naphthalene 70-130 <0.001000.05000.0430 860.05000.0444 89325 Methylene Chloride 75-125 0.01420.05000.0594 1190.05000.0604 121225 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 52 of 68 Final BS / BSD Recoveries Project Name:17792.1 Work Order #: 432605 Project ID:17792.1 Date Analyzed: CYE12/13/201112/13/2011 Analyst:Date Prepared: Solid Matrix: Lab Batch ID:Sample:Batch #: 876915615342-1-BKS1 mg/kg Units: VOAs by SW-846 8260B BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes n-Propylbenzene <0.0002330.05000.0449 900.05000.0476 95675-12525 Styrene <0.0002010.05000.0483 970.05000.0488 98175-12525 1,1,1,2-Tetrachloroethane <0.0003250.05000.0453 910.05000.0493 99872-12525 1,1,2,2-Tetrachloroethane <0.0002140.05000.0500 1000.05000.0488 98274-12525 Tetrachloroethylene 71-125 <0.0001510.05000.0430 860.05000.0448 90425 Toluene 59-139 <0.0003210.05000.0447 890.05000.0479 96725 1,2,4-Trichlorobenzene <0.0003480.05000.0439 880.05000.0489 981175-13525 1,2,3-Trichlorobenzene <0.0003470.05000.0459 920.05000.0491 98775-13725 1,1,2-Trichloroethane <0.0003800.05000.0527 1050.05000.0482 96975-12725 1,1,1-Trichloroethane <0.0002760.05000.0433 870.05000.0472 94975-12525 Trichloroethylene <0.0004400.05000.0437 870.05000.0468 94762-13725 Trichlorofluoromethane 67-125 <0.0002480.05000.0449 900.05000.0489 98925 1,2,3-Trichloropropane 75-125 <0.0003840.05000.0523 1050.05000.0500 100425 1,2,4-Trimethylbenzene <0.0001420.05000.0450 900.05000.0473 95575-12525 1,3,5-Trimethylbenzene <0.0001310.05000.0457 910.05000.0485 97670-13025 Vinyl Chloride <0.0005000.05000.0450 900.05000.0495 991065-13525 o-Xylene <0.0002060.05000.0433 870.05000.0470 94875-12525 m,p-Xylenes <0.0003210.1000.0865 870.1000.0893 89375-12525 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 53 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Solid 876434 QC- Sample ID:432603-001 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:DAT 12/07/2011 Date Analyzed: Reporting Units:ug/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Mercury by SW7471A Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Mercury6.331501509615013988875-12520 Lab Batch ID: 1Solid 876445 QC- Sample ID:432603-001 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:DAT 12/07/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Metals per ICP by SW846 6010B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Arsenic <0.48597.190.89499.092.193175-12520 Barium93.897.119610599.0200107275-12520 Cadmium<0.24397.190.89499.093.194375-12520 Chromium14.097.11079699.011097375-12520 Lead11.697.11019299.010392275-12520 Selenium<0.48597.194.29799.097.098375-12520 Silver<0.19497.196.69999.099.0100275-12520 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 54 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Soil 877310 QC- Sample ID:433216-002 SBatch #:Matrix: 12/14/2011 Date Prepared:Analyst:WEW 12/17/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl SVOA PAHs List by EPA 8270C Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Acenaphthene<0.02012.011.79892.011.8894563-12325 Acenaphthylene <0.02012.011.79892.011.8894563-12225 Anthracene<0.02012.011.72862.011.7989462-12625 Benzo(a)anthracene<0.02012.011.79892.011.9195661-12725 Benzo(a)pyrene<0.02012.011.77882.011.8391364-12725 Benzo(b)fluoranthene<0.02012.011.75872.011.7788161-13025 Benzo(g,h,i)perylene<0.02012.011.51752.011.5678355-12525 Benzo(k)fluoranthene<0.02012.011.65822.011.7989864-12325 Chrysene <0.02012.011.87932.012.00100761-12725 Dibenz(a,h)Anthracene<0.02012.011.78892.011.8592458-13325 Dibenzofuran<0.1012.011.76882.011.8291365-13525 Fluoranthene<0.02012.011.73862.011.8291562-12825 Fluorene<0.02012.011.76882.011.8592565-12325 Indeno(1,2,3-c,d)Pyrene<0.02012.011.81902.011.8793359-13225 Naphthalene<0.02012.011.58792.011.6281360-12225 Phenanthrene <0.02012.011.58792.011.6582462-12725 Pyrene<0.02012.011.87932.011.9798560-12725 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 55 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Soil 876419 QC- Sample ID:432724-001 SBatch #:Matrix: 12/06/2011 Date Prepared:Analyst:JAH 12/06/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl TPH by Texas1005 Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] C6-C12 Gasoline Range Hydrocarbons<59.812001150961200118098375-12535 C12-C28 Diesel Range Hydrocarbons 20212001250871200120083475-12535 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 56 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Soil 876915 QC- Sample ID:432701-001 SBatch #:Matrix: 12/13/2011 Date Prepared:Analyst:CYE 12/13/2011 Date Analyzed: Reporting Units:mg/kg MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Benzene<0.0004480.04980.0478960.04980.049399366-14225 Bromobenzene <0.0002580.04980.05531110.04980.0543109275-12525 Bromochloromethane<0.0006420.04980.05861180.04980.0588118073-12525 Bromodichloromethane<0.0003630.04980.05241050.04980.0523105075-12525 Bromoform<0.0004400.04980.05351070.04980.0542109175-12525 Methyl bromide<0.0008080.04980.0459920.04980.0497100865-13525 MTBE<0.0001650.04980.06621330.04980.0684137365-13525X tert-Butylbenzene<0.0002220.04980.0467940.04980.048197375-12525 Sec-Butylbenzene 0.0002490.04980.0430860.04980.046292775-12525 n-Butylbenzene0.0009360.04980.0392770.04980.041581675-12525 Carbon Tetrachloride<0.0001600.04980.0343690.04980.036573662-12525 Chlorobenzene<0.0002890.04980.0477960.04980.047295160-13325 Chloroethane<0.0007540.04980.05021010.04980.0519104365-13525 Chloroform<0.0003960.04980.05361080.04980.0527106274-12525 Methyl Chloride<0.0003610.04980.05451090.04980.0567114465-13525 2-Chlorotoluene <0.0002460.04980.0493990.04980.0512103473-12525 4-Chlorotoluene<0.0001820.04980.0493990.04980.0510102374-12525 p-Cymene (p-Isopropyltoluene)0.0003690.04980.0422840.04980.044789675-12525 1,2-Dibromo-3-Chloropropane<0.002890.04980.06461300.04980.0689138659-12525X Dibromochloromethane<0.0005300.04980.05771160.04980.0571115173-12525 1,2-Dichlorobenzene<0.0003280.04980.0491990.04980.0505101375-12525 1,3-Dichlorobenzene<0.0002690.04980.0489980.04980.0506102375-12525 1,4-Dichlorobenzene <0.0009960.04980.0482970.04980.047996175-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 57 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Soil 876915 QC- Sample ID:432701-001 SBatch #:Matrix: 12/13/2011 Date Prepared:Analyst:CYE 12/13/2011 Date Analyzed: Reporting Units:mg/kg Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Dichlorodifluoromethane<0.0002470.04980.05511110.04980.0593119765-13525 1,2-Dichloroethane <0.0005210.04980.05131030.04980.0536108468-12725 1,1-Dichloroethane<0.0002800.04980.05591120.04980.0555111172-12525 trans-1,2-dichloroethylene<0.0002260.04980.0474950.04980.047195175-12525 cis-1,2-Dichloroethylene0.0009060.04980.05761140.04980.0575114075-12525 1,1-Dichloroethene<0.0004430.04980.0481970.04980.049599359-17225 2,2-Dichloropropane<0.0003780.04980.0492990.04980.0496100175-12525 1,3-Dichloropropane<0.0003030.04980.06881380.04980.0702141275-12525X 1,2-Dichloropropane <0.0003470.04980.05131030.04980.0508102174-12525 trans-1,3-dichloropropene<0.001080.04980.05021010.04980.049599166-12525 1,1-Dichloropropene<0.0003650.04980.0384770.04980.038577075-12525 cis-1,3-Dichloropropene<0.0003140.04980.0485970.04980.0510102574-12525 Ethylbenzene0.003890.04980.0446820.04980.046085375-12525 Hexachlorobutadiene<0.0002690.04980.0312630.04980.032265375-12525X Naphthalene0.003720.04980.0443810.04980.0500931270-13025 Isopropylbenzene <0.0002270.04980.0469940.04980.0496100675-12525 Methylene Chloride0.008020.04980.06341110.04980.0650114275-12525 n-Propylbenzene0.0006870.04980.0475940.04980.049598475-12525 Styrene<0.0002000.04980.0452910.04980.045191075-12525 1,1,1,2-Tetrachloroethane<0.0003240.04980.05211050.04980.0525105172-12525 1,1,2,2-Tetrachloroethane<0.0002130.04980.08641730.04980.0800161874-12525X Tetrachloroethylene0.001960.04980.0412790.04980.040678171-12525 Toluene 0.008740.04980.0469770.04980.047077059-13925 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 58 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Soil 876915 QC- Sample ID:432701-001 SBatch #:Matrix: 12/13/2011 Date Prepared:Analyst:CYE 12/13/2011 Date Analyzed: Reporting Units:mg/kg Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] 1,2,4-Trichlorobenzene<0.0003470.04980.0355710.04980.0394791075-13525X 1,2,3-Trichlorobenzene <0.0003460.04980.0353710.04980.0398801275-13725X 1,1,2-Trichloroethane<0.0003780.04980.06071220.04980.0635128575-12725X 1,1,1-Trichloroethane<0.0002750.04980.0454910.04980.045692075-12525 Trichloroethylene0.0005680.04980.0400790.04980.042284562-13725 Trichlorofluoromethane<0.0002470.04980.0463930.04980.048497467-12525 1,2,3-Trichloropropane<0.0003820.04980.08011610.04980.0812163175-12525X 1,2,4-Trimethylbenzene0.004430.04980.0502920.04980.051895375-12525 1,3,5-Trimethylbenzene 0.002010.04980.0478920.04980.050898670-13025 Vinyl Chloride<0.0004980.04980.05361080.04980.0570114665-13525 o-Xylene0.004820.04980.0461830.04980.047185275-12525 m,p-Xylenes0.009170.09960.0870780.09960.091883575-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 59 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Water 876464 QC- Sample ID:432528-008 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:CYE 12/07/2011 Date Analyzed: Reporting Units:mg/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Benzene<0.0002600.05000.06751350.05000.05841171466-14225 Bromobenzene <0.0003900.05000.06181240.05000.05411081375-12525 Bromochloromethane<0.0004800.05000.06471290.05000.05781161173-12525X Bromodichloromethane<0.0004200.05000.06051210.05000.05251051475-12525 Bromoform<0.0003400.05000.05491100.05000.0514103775-12525 Methyl bromide<0.0008700.05000.0434870.05000.046192670-13025 MTBE<0.0004300.05000.07431490.05000.06721341065-13525X n-Butylbenzene<0.0001900.05000.06751350.05000.05921181375-12525X Sec-Butylbenzene <0.0001200.05000.07061410.05000.06221241375-12525X tert-Butylbenzene<0.0002000.05000.06871370.05000.05981201475-12525X Carbon Tetrachloride<0.0001400.05000.06161230.05000.05251051662-12525 Chlorobenzene<0.0002700.05000.06241250.05000.05421081460-13325 Chloroethane0.0008300.05000.0409800.05000.0482951670-13025 Chloroform<0.0006200.05000.05921180.05000.05291061174-12525 Methyl Chloride<0.0004200.05000.05221040.05000.0570114970-13025 2-Chlorotoluene <0.0003000.05000.06681340.05000.05761151573-12525X 4-Chlorotoluene<0.0002500.05000.06591320.05000.05591121674-12525X p-Cymene (p-Isopropyltoluene)<0.0002300.05000.06951390.05000.06091221375-12525X Dibromochloromethane<0.0003500.05000.05691140.05000.0563113173-12525 1,2-Dibromo-3-Chloropropane<0.001430.05000.0469940.05000.047094059-12525 1,2-Dibromoethane<0.0003600.05000.06051210.05000.0598120173-12525 Methylene bromide<0.0004700.05000.05921180.05000.05271051269-12725 1,2-Dichlorobenzene <0.0002400.05000.06391280.05000.05631131375-12525X Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 60 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Water 876464 QC- Sample ID:432528-008 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:CYE 12/07/2011 Date Analyzed: Reporting Units:mg/L Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] 1,3-Dichlorobenzene<0.0001900.05000.06511300.05000.05821161175-12525X 1,4-Dichlorobenzene <0.0003600.05000.06411280.05000.05641131375-12525X Dichlorodifluoromethane<0.0003100.05000.05821160.05000.0635127970-13025 1,1-Dichloroethane<0.0003100.05000.06761350.05000.05711141772-12525X 1,2-Dichloroethane<0.0002700.05000.05201040.05000.0461921268-12725 1,1-Dichloroethene<0.0003300.05000.07531510.05000.06301261859-17225 cis-1,2-Dichloroethylene<0.0003500.05000.06861370.05000.06151231175-12525X trans-1,2-dichloroethylene<0.0003400.05000.06671330.05000.05511101975-12525X 1,2-Dichloropropane <0.0003700.05000.06311260.05000.05521101374-12525X 1,3-Dichloropropane<0.0003300.05000.06011200.05000.0637127675-12525X 2,2-Dichloropropane<0.0002600.05000.06841370.05000.05901181575-12525X 1,1-Dichloropropene<0.0004100.05000.06731350.05000.05841171475-12525X cis-1,3-Dichloropropene<0.0002500.05000.05641130.05000.05121021074-12525 trans-1,3-dichloropropene<0.0003000.05000.0461920.05000.0498100866-12525 Ethylbenzene<0.00008000.05000.06491300.05000.05611121575-12525X Hexachlorobutadiene <0.0005600.05000.06261250.05000.05341071675-12525 Isopropylbenzene<0.0002500.05000.06611320.05000.05751151475-12525X Methylene Chloride0.001300.05000.06271230.05000.05331041675-12525 Naphthalene<0.0004300.05000.05751150.05000.05131031175-12525 n-Propylbenzene<0.0001800.05000.07041410.05000.05851171875-12525X Styrene<0.0001400.05000.06871370.05000.06021201375-12525X 1,1,1,2-Tetrachloroethane<0.0002800.05000.06191240.05000.05581121072-12525 1,1,2,2-Tetrachloroethane <0.0004200.05000.06241250.05000.05361071574-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 61 of 68 Final Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432605 Lab Batch ID: 1Water 876464 QC- Sample ID:432528-008 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:CYE 12/07/2011 Date Analyzed: Reporting Units:mg/L Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Tetrachloroethylene<0.0005900.05000.05651130.05000.0554111271-12525 Toluene <0.0004900.05000.06641330.05000.0606121959-13925 1,2,3-Trichlorobenzene<0.0002600.05000.06181240.05000.05391081475-13725 1,2,4-Trichlorobenzene<0.0004400.05000.06021200.05000.05261051375-13525 1,1,1-Trichloroethane<0.0003100.05000.06361270.05000.05281061975-12525X 1,1,2-Trichloroethane<0.0004100.05000.05331070.05000.0573115775-12725 Trichloroethylene<0.0003900.05000.06221240.05000.05471091362-13725 Trichlorofluoromethane<0.0003300.05000.04991000.05000.05561111167-12525 1,2,3-Trichloropropane <0.0005900.05000.06061210.05000.05491101075-12525 1,2,4-Trimethylbenzene<0.0001400.05000.06941390.05000.06041211475-12525X 1,3,5-Trimethylbenzene<0.0002500.05000.06831370.05000.05791161670-12525X o-Xylene<0.0003100.05000.06631330.05000.05731151575-12525X m,p-Xylenes<0.0004700.1000.1341340.1000.1141141675-12525X Vinyl Chloride<0.0003100.05000.0488980.05000.05401081075-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 62 of 68 Final Sample Duplicate Recovery 17792.1 Project Name: Work Order #:432605 17792.1 Project ID: 877097 Lab Batch #: 12/15/2011 Date Prepared:Analyst:MAB 12/15/2011 10:00 Date Analyzed: 1Solid Batch #:Matrix: QC- Sample ID:432605-001 D SAMPLE / SAMPLE DUPLICATE RECOVERY % Reporting Units: Percent Moisture SampleControl Parent Sample DuplicateRPDLimits Result Flag Result%RPD [A] [B] Analyte Percent Moisture 14.512.2 1720 877097 Lab Batch #: 12/15/2011 Date Prepared:Analyst:MAB 12/15/2011 10:00 Date Analyzed: 1Soil Batch #:Matrix: QC- Sample ID:433313-009 D SAMPLE / SAMPLE DUPLICATE RECOVERY % Reporting Units: Percent Moisture SampleControl Parent Sample DuplicateRPDLimits Result Flag Result%RPD [A] [B] Analyte Percent Moisture29.827.7 720 Spike Relative Difference RPD 200 * | (B-A)/(B+A) | All Results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 63 of 68 Final Page 64 of 68 Final Page 65 of 68 Final Page 66 of 68 Final Page 67 of 68 Final XENCO Laboratories Prelogin/Nonconformance Report- Sample Log-In Client:Reed Engineering Group, Inc. Acceptable Temperature Range: 0 - 6 degC Air and Metal samples Acceptable Range: Ambient Date/ Time Received:12/02/2011 05:12:03 PM Temperature Measuring device used : Work Order #:432605 Sample Receipt Checklist Comments #1 *Temperature of cooler(s)?2.2 Yes #2 *Shipping container in good condition? Yes #3 *Samples received on ice? #4 *Custody Seals intact on shipping container/ cooler?No No #5 Custody Seals intact on sample bottles/ container? No #6 *Custody Seals Signed and dated for Containers/coolers Yes #7 *Chain of Custody present? #8 Sample instructions complete on Chain of Custody?Yes No #9 Any missing/extra samples? Yes #10 Chain of Custody signed when relinquished/ received? Yes #11 Chain of Custody agrees with sample label(s)? #12 Container label(s) legible and intact?Yes Yes #13 Sample matrix/ properties agree with Chain of Custody? Yes #14 Samples in proper container/ bottle? Yes #15 Samples properly preserved? #16 Sample container(s) intact?Yes Yes #17 Sufficient sample amount for indicated test(s)? Yes #18 All samples received within hold time? Yes #19 Subcontract of sample(s)?Xenco Houston #20 VOC samples have zero headspace (less than 1/4 inch bubble)?Yes Yes #21 <2 for all samples preserved with HNO3,HCL, H2SO4? N/A #22 >10 for all samples preserved with NaAsO2+NaOH, ZnAc+NaOH? * Must be completed for after-hours delivery of samples prior to placing in the refrigerator Analyst: PH Device/Lot#: NonConformance: Corrective Action Taken: Nonconformance Documentation Contact:Contacted by :DateTime : Checklist completed by: Date:12/03/2011 Angelica Martinez Checklist reviewed by: Date:12/02/2011 Page 68 of 68 Final Analytical Report 432604 for Reed Engineering Group, Inc. Project Manager: Chris McCaslin 17792.1 17792.1 07-DEC-11 Collected By: Client Celebrating 20 Years of commitment to excellence in Environmental Testing Services 9701 Harry Hines Blvd, Dallas, TX 75220 Ph:(214) 902-0300 Fax:(214) 351-9139 Xenco-Houston (EPA Lab code: TX00122): Texas (T104704215-10-6-TX), Arizona (AZ0765), Arkansas (08-039-0), Connecticut (PH-0102), Florida (E871002) Illinois (002082), Indiana (C-TX-02), Iowa (392), Kansas (E-10380), Kentucky (45), Louisiana (03054) New Hampshire (297408), New Jersey (TX007), New York (11763), Oklahoma (9218), Pennsylvania (68-03610) Rhode Island (LAO00312), USDA (S-44102) Xenco-Atlanta (EPA Lab Code: GA00046): Florida (E87429), North Carolina (483), South Carolina (98015), Utah (AALI1), West Virginia (362), Kentucky (85) Louisiana (04176), USDA (P330-07-00105) Xenco-Miami (EPA Lab code: FL01152): Florida (E86678), Maryland (330) Xenco-Tampa Mobile (EPA Lab code: FL01212): Florida (E84900) Xenco-Odessa (EPA Lab code: TX00158): Texas (T104704400-TX) Xenco-Dallas (EPA Lab code: TX01468): Texas (T104704295-TX) Xenco Phoenix (EPA Lab Code: AZ00901): Arizona(AZ0757) Xenco-Phoenix Mobile (EPA Lab code: AZ00901): Arizona (AZM757) Xenco Tucson (EPA Lab code:AZ000989): Arizona (AZ0758) Page 1 of 9 Final 1. 07-DEC-11 Chris McCaslin Project Manager: Reed Engineering Group, Inc. 2424 Stutz Drive, Suite 400 Dallas, TX 75235 432604 Reference: XENCO Report No: 17792.1 Project Address: - Chris McCaslin : We are reporting to you the results of the analyses performed on the samples received under the project name referenced above and identified with the XENCO Report Number432604. All results being reported under this Report Number apply to the samples analyzed and properly identified with a Laboratory ID number. Subcontracted analyses are identified in this report with either the NELAC certification number of the subcontract lab in the analyst ID field, or the complete subcontracted report attached to this report. Unless otherwise noted in a Case Narrative, all data reported in this Analytical Report are in compliance with NELAC standards. Estimation of data uncertainty for this report is found in the quality control section of this report unless otherwise noted. Should insufficient sample be provided to the laboratory to meet the method and NELAC Matrix Duplicate and Matrix Spike requirements, then the data will be analyzed, evaluated and reported using all other available quality control measures. The validity and integrity of this report will remain intact as long as it is accompanied by this letter and reproduced in full, unless written approval is granted by XENCO Laboratories. This report will be filed for at least 5 years in our archives after which time it will be destroyed without further notice, unless otherwise arranged with you. The samples received, and described as recorded in Report No. 432604 will be filed for 60 days, and after that time they will be properly disposed without further notice, unless otherwise arranged with you. We reserve the right to return to you any unused samples, extracts or solutions related to them if we consider so necessary (e.g., samples identified as hazardous waste, sample sizes exceeding analytical standard practices, controlled substances under regulated protocols, etc). We thank you for selecting XENCO Laboratories to serve your analytical needs. If you have any questions concerning this report, please feel free to contact us at any time. Respectfully, Carlos Castro Managing Director, Texas Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Austin - Tampa - Miami - Atlant Page 2 of 9 Final 1. CASE NARRATIVE Client Name: Reed Engineering Group, Inc. Project Name: 17792.1 07-DEC-11 Project ID: 17792.1Report Date: Work Order Number: 12/02/2011 432604Date Received: Sample receipt non conformances and comments: Client did not specify which metals needed. Per Chris M need RCR Sample receipt non conformances and comments per sample: None Page 3 of 9 Final 1. Certificate of Analysis Summary432604 Reed Engineering Group, Inc., Dallas, TX Project Name:17792.1 Project Id:17792.1 Date Received in Lab:Fri Dec-02-11 05:12 pm Chris McCaslin Contact: Report Date:07-DEC-11 Project Location:- Project Manager:Monica Tobar Lab Id: 432604-001432604-002 Field Id: MW-1MW-2 Analysis Requested Depth: Matrix: WATERWATER Sampled: Dec-02-11 14:05Dec-02-11 11:45 Mercury by SW7470A Extracted: Dec-07-11 08:00Dec-07-11 08:00 Analyzed: Dec-07-11 11:53Dec-07-11 11:55 Units/RL:ug/LRLug/LRL MercuryBRL 0.100 BRL 0.100 Metals per ICP by SW846 6010B Extracted:Dec-05-11 06:45Dec-05-11 06:45 Analyzed: Dec-06-11 12:37Dec-06-11 12:39 Units/RL: mg/LRLmg/LRL 0.01000.0100 ArsenicBRLBRL 0.3400.01000.2460.0100 Barium CadmiumBRL 0.00500 BRL 0.00500 ChromiumBRL 0.00500 BRL 0.00500 LeadBRL 0.0120 BRL 0.0120 SeleniumBRL 0.0100 BRL 0.0100 SilverBRL 0.00400 BRL 0.00400 This analytical report, and the entire data package it represents, has been made for your exclusive and confidential use. The interpretations and results expressed throughout this analytical report represent the best judgment of XENCO Laboratories. XENCO Laboratories assumes no responsibility and makes no warranty to the end use of the data hereby presented. Our liability is limited to the amount invoiced for this work order unless otherwise agreed to in writing. ________________________________ Houston - Dallas - San Antonio - Atlanta - Tampa - Boca Raton - Latin America - Odessa - Corpus Christi Carlos Castro Managing Director, Texas Page 4 of 9 Final 1. Flagging Criteria X In our quality control review of the data a QC deficiency was observed and flagged as noted. MS/MSD recoveries were found to be outside of the laboratory control limits due to possible matrix /chemical interference, or a concentration of target analyte high enough to affect the recovery of the spike concentration. This condition could also affect the relative percent difference in the MS/MSD. B A target analyte or common laboratory contaminant was identified in the method blank. Its presence indicates possible field or laboratory contamination. D The sample(s) were diluted due to targets detected over the highest point of the calibration curve, or due to matrix interference. Dilution factors are included in the final results. The result is from a diluted sample. E The data exceeds the upper calibration limit; therefore, the concentration is reported as estimated. F RPD exceeded lab control limits. J The target analyte was positively identified below the quantiation limit and above the detection limit. U Analyte was not detected. L The LCS data for this analytical batch was reported below the laboratory control limits for this analyte. The department supervisor and QA Director reviewed data. The samples were either reanalyzed or flagged as estimated concentrations. H The LCS data for this analytical batch was reported above the laboratory control limits. Supporting QC Data were reviewed by the Department Supervisor and QA Director. Data were determined to be valid for reporting. K Sample analyzed outside of recommended hold time. JN A combination of the "N" and the "J" qualifier. The analysis indicates that the analyte is "tentatively identified" and the associated numerical value may not be consistent with the amount actually present in the environmental sample. * Surrogate recovered outside laboratory control limit. BRL Below Reporting Limit. RL Reporting Limit MDLSDLLOD Method Detection LimitSample Detection LimitLimit of Detection PQLMQLLOQ Practical Quantitation Limit Method Quantitation LimitLimit of Quantitation DL Method Detection Limit NC Non-Calculable + Outside XENCO's scope of NELAC Accreditation. ^NELAC or State program does not offer Accreditation at this time. Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Atlanta - Midland/Odessa - Tamp Phone Fax 4143 Greenbriar Dr, Stafford, TX 77477 (281) 240-4200 (281) 240-4280 9701 Harry Hines Blvd , Dallas, TX 75220 (214) 902 0300 (214) 351-9139 5332 Blackberry Drive, San Antonio TX 78238 (210) 509-3334 (210) 509-3335 2505 North Falkenburg Rd, Tampa, FL 33619 (813) 620-2000 (813) 620-2033 5757 NW 158th St, Miami Lakes, FL 33014 (305) 823-8500 (305) 823-8555 12600 West I-20 East, Odessa, TX 79765 (432) 563-1800 (432) 563-1713 6017 Financial Drive, Norcross, GA 30071 (770) 449-8800 (770) 449-5477 3725 E. Atlanta Ave, Phoenix, AZ 85040 (602) 437-0330 Page 5 of 9 Final 1. BS / BSD Recoveries Project Name:17792.1 Work Order #: 432604 Project ID:17792.1 Date Analyzed: DAT12/07/201112/07/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 876433615036-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY ug/L Units: Mercury by SW7470A BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Mercury <0.1005.004.92 985.004.65 93675-12520 Date Analyzed: DAT12/05/201112/06/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 876435614908-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/L Units: Metals per ICP by SW846 6010B BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Arsenic <0.01001.000.986 991.000.976 98185-11520 Barium 85-115 <0.01001.000.936 941.000.928 93120 Cadmium 85-115 <0.005001.001.02 1021.001.01 101120 Chromium <0.005001.001.00 1001.000.999 100085-11520 Lead <0.01201.001.04 1041.001.03 103185-11520 Selenium <0.01001.000.964 961.000.982 98285-11520 Silver <0.004001.000.970 971.000.965 97185-11520 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 6 of 9 Final 1. Form 3 - MS / MSD Recoveries Project Name:17792.1 Work Order # :Project ID: 17792.1 432604 Lab Batch ID: 1Water 876433 QC- Sample ID:432528-001 SBatch #:Matrix: 12/07/2011 Date Prepared:Analyst:DAT 12/07/2011 Date Analyzed: Reporting Units:ug/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Mercury by SW7470A Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Mercury<0.1005.004.75955.004.4489775-12520 Lab Batch ID: 1Water 876435 QC- Sample ID:432397-001 SBatch #:Matrix: 12/05/2011 Date Prepared:Analyst:DAT 12/06/2011 Date Analyzed: Reporting Units:mg/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Metals per ICP by SW846 6010B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Arsenic <0.01001.001.031031.001.03103075-12520 Barium<0.01001.000.943941.000.94294075-12520 Cadmium<0.005001.001.031031.001.02102175-12520 Chromium<0.005001.000.989991.000.98498175-12520 Lead<0.01201.001.011011.001.01101075-12520 Selenium<0.01001.001.021021.001.01101175-12520 Silver<0.004001.000.975981.000.97698075-12520 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 7 of 9 Final 1. Page 8 of 9 Final 1. XENCO Laboratories Prelogin/Nonconformance Report- Sample Log-In Client:Reed Engineering Group, Inc. Acceptable Temperature Range: 0 - 6 degC Air and Metal samples Acceptable Range: Ambient Date/ Time Received:12/02/2011 05:12:01 PM Temperature Measuring device used : Work Order #:432604 Sample Receipt Checklist Comments #1 *Temperature of cooler(s)?2.2 Yes #2 *Shipping container in good condition? Yes #3 *Samples received on ice? #4 *Custody Seals intact on shipping container/ cooler?No No #5 Custody Seals intact on sample bottles/ container? No #6 *Custody Seals Signed and dated for Containers/coolers Yes #7 *Chain of Custody present? #8 Sample instructions complete on Chain of Custody?Yes No #9 Any missing/extra samples? Yes #10 Chain of Custody signed when relinquished/ received? Yes #11 Chain of Custody agrees with sample label(s)? #12 Container label(s) legible and intact?Yes Yes #13 Sample matrix/ properties agree with Chain of Custody? Yes #14 Samples in proper container/ bottle? Yes #15 Samples properly preserved? #16 Sample container(s) intact?Yes Yes #17 Sufficient sample amount for indicated test(s)? Yes #18 All samples received within hold time? No #19 Subcontract of sample(s)? #20 VOC samples have zero headspace (less than 1/4 inch bubble)?N/A Yes #21 <2 for all samples preserved with HNO3,HCL, H2SO4? N/A #22 >10 for all samples preserved with NaAsO2+NaOH, ZnAc+NaOH? * Must be completed for after-hours delivery of samples prior to placing in the refrigerator Analyst: PH Device/Lot#: NonConformance: Corrective Action Taken: Nonconformance Documentation Contact:Contacted by :DateTime : Checklist completed by: Date:12/03/2011 Angelica Martinez Checklist reviewed by: Date:12/02/2011 Page 9 of 9 Final 1. Analytical Report 432741 for Reed Engineering Group, Inc. Project Manager: Chris McCaslin --- 177921.1 19-DEC-11 Collected By: Client Celebrating 20 Years of commitment to excellence in Environmental Testing Services 9701 Harry Hines Blvd, Dallas, TX 75220 Ph:(214) 902-0300 Fax:(214) 351-9139 Xenco-Houston (EPA Lab code: TX00122): Texas (T104704215-10-6-TX), Arizona (AZ0765), Arkansas (08-039-0), Connecticut (PH-0102), Florida (E871002) Illinois (002082), Indiana (C-TX-02), Iowa (392), Kansas (E-10380), Kentucky (45), Louisiana (03054) New Hampshire (297408), New Jersey (TX007), New York (11763), Oklahoma (9218), Pennsylvania (68-03610) Rhode Island (LAO00312), USDA (S-44102) Xenco-Atlanta (EPA Lab Code: GA00046): Florida (E87429), North Carolina (483), South Carolina (98015), Utah (AALI1), West Virginia (362), Kentucky (85) Louisiana (04176), USDA (P330-07-00105) Xenco-Miami (EPA Lab code: FL01152): Florida (E86678), Maryland (330) Xenco-Tampa Mobile (EPA Lab code: FL01212): Florida (E84900) Xenco-Odessa (EPA Lab code: TX00158): Texas (T104704400-TX) Xenco-Dallas (EPA Lab code: TX01468): Texas (T104704295-TX) Xenco Phoenix (EPA Lab Code: AZ00901): Arizona(AZ0757) Xenco-Phoenix Mobile (EPA Lab code: AZ00901): Arizona (AZM757) Xenco Tucson (EPA Lab code:AZ000989): Arizona (AZ0758) Page 1 of 34 Final 1 Table of Contents Cover Page1 Cover Letter3 Sample ID Cross Reference4 Certificate of Analysis (Detailed Report)5 Holding Time Report12 Explanation of Qualifiers (Flags)16 Analytical Log17 Surrogate Recoveries_QC21 Blank Spike Recoveries23 Blank Spike - Blank Spike Duplicate Recoveries25 Matrix Spike - Matrix Spike Duplicate Recoveries27 Method Duplicate31 Chain of Custody32 Page 2 of 34 Final 1 19-DEC-11 Chris McCaslin Project Manager: Reed Engineering Group, Inc. 2424 Stutz Drive, Suite 400 Dallas, TX 75235 432741 Reference: XENCO Report No: --- Project Address: 177921.1 Chris McCaslin : We are reporting to you the results of the analyses performed on the samples received under the project name referenced above and identified with the XENCO Report Number432741. All results being reported under this Report Number apply to the samples analyzed and properly identified with a Laboratory ID number. Subcontracted analyses are identified in this report with either the NELAC certification number of the subcontract lab in the analyst ID field, or the complete subcontracted report attached to this report. Unless otherwise noted in a Case Narrative, all data reported in this Analytical Report are in compliance with NELAC standards. Estimation of data uncertainty for this report is found in the quality control section of this report unless otherwise noted. Should insufficient sample be provided to the laboratory to meet the method and NELAC Matrix Duplicate and Matrix Spike requirements, then the data will be analyzed, evaluated and reported using all other available quality control measures. The validity and integrity of this report will remain intact as long as it is accompanied by this letter and reproduced in full, unless written approval is granted by XENCO Laboratories. This report will be filed for at least 5 years in our archives after which time it will be destroyed without further notice, unless otherwise arranged with you. The samples received, and described as recorded in Report No. 432741 will be filed for 60 days, and after that time they will be properly disposed without further notice, unless otherwise arranged with you. We reserve the right to return to you any unused samples, extracts or solutions related to them if we consider so necessary (e.g., samples identified as hazardous waste, sample sizes exceeding analytical standard practices, controlled substances under regulated protocols, etc). We thank you for selecting XENCO Laboratories to serve your analytical needs. If you have any questions concerning this report, please feel free to contact us at any time. Respectfully, Carlos Castro Managing Director, Texas Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Austin - Tampa - Miami - Atlant Page 3 of 34 Final 1 Sample Cross Reference 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample IdMatrixDate Collected Sample DepthLab Sample Id MW-3W12-06-11 09:40432741-001 MW-4W12-06-11 11:20432741-002 Page 4 of 34 Final 1 Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-3Matrix:WaterSample Depth: Lab Sample Id:432741-001Date Collected: Dec-06-11 09:40 Date Received:Dec-06-11 12:53 Analytical Method:Metals, Total by SW846 6010CPrep Method: 3010A % Moist: Tech:4150 Date Anal:Dec-15-11 15:10 Analyst:4150 Date Prep: Dec-14-11 12:21 Anal seq: 877169Prep seq: 615381 Subcontractor: SUB: TX104704477 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-20.009600.01000.01000.00400mg/LJ 1 0.00400 Barium 7440-39-30.04600.05000.05000.00200mg/LJ 1 0.00200 Cadmium7440-43-9U0.005000.005000.000300mg/LU 1 0.000300 Chromium0.00100J 7440-47-30.05000.05000.000300mg/L 1 0.000300 Lead7439-92-10.005900.01000.01000.00330mg/LJ 1 0.00330 Selenium7782-49-2U0.01000.01000.0113mg/LU 1 0.0113 Silver0.000600 7440-22-40.05000.05000.000600mg/LJ 1 0.000600 Page 5 of 34 Final 1 Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-3Matrix:WaterSample Depth: Lab Sample Id:432741-001Date Collected: Dec-06-11 09:40 Date Received:Dec-06-11 12:53 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-09-11 18:42 Analyst:CYE Date Prep: Dec-09-11 14:20 Anal seq: 876765Prep seq: 615261 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000260mg/LU 1 0.000260 Bromobenzene108-86-1U0.005000.005000.000390mg/LU 1 0.000390 Bromochloromethane74-97-5U0.005000.005000.000480mg/LU 1 0.000480 Bromodichloromethane 75-27-4U0.005000.005000.000420mg/LU 1 0.000420 Bromoform75-25-2U0.005000.005000.000340mg/LU 1 0.000340 Methyl bromide74-83-9U0.005000.005000.000870mg/LU 1 0.000870 MTBE1634-04-4U0.005000.005000.000430mg/LU 1 0.000430 n-Butylbenzene104-51-8U0.005000.005000.000190mg/LU 1 0.000190 Sec-Butylbenzene135-98-8U0.005000.005000.000120mg/LU 1 0.000120 tert-Butylbenzene98-06-6U0.005000.005000.000200mg/LU 1 0.000200 Carbon Tetrachloride56-23-5U0.005000.005000.000140mg/LU 1 0.000140 Chlorobenzene108-90-7U0.005000.005000.000270mg/LU 1 0.000270 Chloroethane75-00-3U0.01000.01000.000206mg/LU 1 0.000206 Chloroform67-66-3U0.005000.005000.000620mg/LU 1 0.000620 Methyl Chloride74-87-30.0004200.01000.01000.000420mg/LJ 1 0.000420 2-Chlorotoluene95-49-8U0.005000.005000.000300mg/LU 1 0.000300 4-Chlorotoluene106-43-4U0.005000.005000.000250mg/LU 1 0.000250 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000230mg/LU 1 0.000230 Dibromochloromethane124-48-1U0.005000.005000.000350mg/LU 1 0.000350 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00143mg/LU 1 0.00143 1,2-Dibromoethane106-93-4U0.005000.005000.000360mg/LU 1 0.000360 Methylene bromide74-95-3U0.005000.005000.000470mg/LU 1 0.000470 1,2-Dichlorobenzene95-50-1U0.005000.005000.000240mg/LU 1 0.000240 1,3-Dichlorobenzene541-73-1U0.005000.005000.000190mg/LU 1 0.000190 1,4-Dichlorobenzene106-46-7U0.005000.005000.000360mg/LU 1 0.000360 Dichlorodifluoromethane75-71-8U0.005000.005000.000310mg/LU 1 0.000310 1,1-Dichloroethane75-34-3U0.005000.005000.000310mg/LU 1 0.000310 1,2-Dichloroethane107-06-2U0.005000.005000.000270mg/LU 1 0.000270 1,1-Dichloroethene75-35-4U0.005000.005000.000330mg/LU 1 0.000330 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000350mg/LU 1 0.000350 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000340mg/LU 1 0.000340 1,2-Dichloropropane78-87-5U0.005000.005000.000370mg/LU 1 0.000370 1,3-Dichloropropane142-28-9U0.005000.005000.000330mg/LU 1 0.000330 2,2-Dichloropropane594-20-7U0.005000.005000.000260mg/LU 1 0.000260 1,1-Dichloropropene563-58-6U0.005000.005000.000410mg/LU 1 0.000410 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000250mg/LU 1 0.000250 trans-1,3-dichloropropene10061-02-6U0.005000.005000.000300mg/LU 1 0.000300 Ethylbenzene100-41-40.0001800.005000.005000.0000800mg/LJ 1 0.0000800 Hexachlorobutadiene87-68-3U0.005000.005000.000560mg/LU 1 0.000560 Isopropylbenzene98-82-8U0.005000.005000.000250mg/LU 1 0.000250 Methylene Chloride75-09-20.005100.005000.005000.000750mg/LB 1 0.000750 Naphthalene91-20-3U0.01000.01000.000430mg/LU 1 0.000430 n-Propylbenzene103-65-1U0.005000.005000.000180mg/LU 1 0.000180 Styrene100-42-5U0.005000.005000.000140mg/LU 1 0.000140 Page 6 of 34 Final 1 Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-3Matrix:WaterSample Depth: Lab Sample Id:432741-001Date Collected: Dec-06-11 09:40 Date Received:Dec-06-11 12:53 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-09-11 18:42 Analyst:CYE Date Prep: Dec-09-11 14:20 Anal seq: 876765Prep seq: 615261 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000280mg/LU 1 0.000280 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000420mg/LU 1 0.000420 Tetrachloroethylene127-18-4U0.005000.005000.000590mg/LU 1 0.000590 Toluene108-88-3U0.005000.005000.000490mg/LU 1 0.000490 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.000260mg/LU 1 0.000260 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000440mg/LU 1 0.000440 1,1,1-Trichloroethane71-55-6U0.005000.005000.000310mg/LU 1 0.000310 1,1,2-Trichloroethane79-00-5U0.005000.005000.000410mg/LU 1 0.000410 Trichloroethylene79-01-6U0.005000.005000.000390mg/LU 1 0.000390 Trichlorofluoromethane75-69-4U0.005000.005000.000330mg/LU 1 0.000330 1,2,3-Trichloropropane96-18-4U0.005000.005000.000590mg/LU 1 0.000590 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000140mg/LU 1 0.000140 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000250mg/LU 1 0.000250 o-Xylene95-47-6U0.005000.005000.000310mg/LU 1 0.000310 m,p-Xylenes1330-20-7U0.01000.01000.000470mg/LU 1 0.000470 Vinyl Chloride75-01-4U0.002000.002000.000310mg/LU 1 0.000310 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9574 - 124% Dibromofluoromethane9775 - 131% 1,2-Dichloroethane-D49763 - 144% Toluene-D89480 - 117% Mercury by SW7470APrep Method: % Moist: Tech:DAT Date Anal:Dec-09-11 09:49 Analyst:DAT Date Prep: Dec-09-11 07:00 Anal seq: 876629Prep seq: 615146 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-6U0.1000.1000.0330ug/LU 1 0.0330 Page 7 of 34 Final 1 Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-3Matrix:WaterSample Depth: Lab Sample Id:432741-001Date Collected: Dec-06-11 09:40 Date Received:Dec-06-11 12:53 Analytical Method:Total Petroleum Hydrocarbons by Texas 1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-09-11 18:03 Analyst:JAH Date Prep: Dec-09-11 15:00 Anal seq: 876735Prep seq: 615237 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612U5.005.000.990mg/LU 1 0.990 C12 - C28 Diesel Range Hydrocarbons PHCG1028U5.005.001.42mg/LU 1 1.42 C28-C35 Oil Range HydrocarbonsPHCG2835U5.005.001.50mg/LU 1 1.50 mg/L Total TPH 1005PHC635UU Surrogate% RecLimitsUnitsFlag 1-Chlorooctane6170 - 130%** o-Terphenyl5770 - 130%** Sample Id:MW-4Matrix:WaterSample Depth: Lab Sample Id:432741-002Date Collected: Dec-06-11 11:20 Date Received:Dec-06-11 12:53 Analytical Method:Metals, Total by SW846 6010C% Moist:Prep Method: 3010A Tech:4150 Date Anal:Dec-15-11 15:12 Analyst:4150 Date Prep: Dec-14-11 12:21 Anal seq: 877169Prep seq: 615381 Subcontractor: SUB: TX104704477 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-20.007300.01000.01000.00400mg/LJ 1 0.00400 Barium0.0830 7440-39-30.05000.05000.00200mg/L 1 0.00200 0.000300mg/L Cadmium7440-43-9U0.005000.00500U 1 0.000300 Chromium7440-47-30.0004000.05000.05000.000300mg/LJ 1 0.000300 Lead0.00360 7439-92-10.01000.01000.00330mg/LJ 1 0.00330 Selenium7782-49-2U0.01000.01000.0113mg/LU 1 0.0113 Silver7440-22-40.0008000.05000.05000.000600mg/LJ 1 0.000600 Mercury by SW7470A% Moist:Prep Method: Tech:DAT Date Anal:Dec-09-11 09:51 Analyst:DAT Date Prep: Dec-09-11 07:00 Anal seq: 876629Prep seq: 615146 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-6U0.1000.1000.0330ug/LU 1 0.0330 Page 8 of 34 Final 1 Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:615146-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615146-1-BLKDate Collected: Date Received:Dec-06-11 12:53 Analytical Method:Mercury by SW7470APrep Method: % Moist: Tech:DAT Date Anal:Dec-09-11 09:07 Analyst:DAT Date Prep: Dec-09-11 07:00 Anal seq: 876629Prep seq: 615146 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-6U0.1000.1000.0330ug/LU 1 0.0330 Sample Id:615237-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615237-1-BLKDate Collected: Date Received:Dec-06-11 12:53 Analytical Method:Total Petroleum Hydrocarbons by Texas 1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-09-11 16:56 Analyst:JAH Date Prep: Dec-09-11 15:00 Anal seq: 876735Prep seq: 615237 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons 0.990mg/L PHC612U5.005.00U 1 0.990 C12 - C28 Diesel Range Hydrocarbons PHCG1028U5.005.001.42mg/LU 1 1.42 C28-C35 Oil Range HydrocarbonsPHCG2835U5.005.001.50mg/LU 1 1.50 Surrogate% RecLimitsUnitsFlag 1-Chlorooctane6870 - 130%** o-Terphenyl6570 - 130%** Page 9 of 34 Final 1 Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:615261-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615261-1-BLKDate Collected: Date Received:Dec-06-11 12:53 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-09-11 14:28 Analyst:CYE Date Prep: Dec-09-11 11:00 Anal seq: 876765Prep seq: 615261 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.000260mg/LU 1 0.000260 Bromobenzene108-86-1U0.005000.005000.000390mg/LU 1 0.000390 Bromochloromethane74-97-5U0.005000.005000.000480mg/LU 1 0.000480 Bromodichloromethane 75-27-4U0.005000.005000.000420mg/LU 1 0.000420 Bromoform75-25-2U0.005000.005000.000340mg/LU 1 0.000340 Methyl bromide74-83-9U0.005000.005000.000870mg/LU 1 0.000870 MTBE1634-04-4U0.005000.005000.000430mg/LU 1 0.000430 n-Butylbenzene104-51-8U0.005000.005000.000190mg/LU 1 0.000190 Sec-Butylbenzene135-98-8U0.005000.005000.000120mg/LU 1 0.000120 tert-Butylbenzene98-06-6U0.005000.005000.000200mg/LU 1 0.000200 Carbon Tetrachloride56-23-5U0.005000.005000.000140mg/LU 1 0.000140 Chlorobenzene108-90-7U0.005000.005000.000270mg/LU 1 0.000270 Chloroethane75-00-3U0.01000.01000.000206mg/LU 1 0.000206 Chloroform67-66-3U0.005000.005000.000620mg/LU 1 0.000620 Methyl Chloride74-87-3U0.01000.01000.000420mg/LU 1 0.000420 2-Chlorotoluene95-49-8U0.005000.005000.000300mg/LU 1 0.000300 4-Chlorotoluene106-43-4U0.005000.005000.000250mg/LU 1 0.000250 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.000230mg/LU 1 0.000230 Dibromochloromethane124-48-1U0.005000.005000.000350mg/LU 1 0.000350 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00143mg/LU 1 0.00143 1,2-Dibromoethane106-93-4U0.005000.005000.000360mg/LU 1 0.000360 Methylene bromide74-95-3U0.005000.005000.000470mg/LU 1 0.000470 1,2-Dichlorobenzene95-50-1U0.005000.005000.000240mg/LU 1 0.000240 1,3-Dichlorobenzene541-73-1U0.005000.005000.000190mg/LU 1 0.000190 1,4-Dichlorobenzene106-46-7U0.005000.005000.000360mg/LU 1 0.000360 Dichlorodifluoromethane75-71-8U0.005000.005000.000310mg/LU 1 0.000310 1,1-Dichloroethane75-34-3U0.005000.005000.000310mg/LU 1 0.000310 1,2-Dichloroethane107-06-2U0.005000.005000.000270mg/LU 1 0.000270 1,1-Dichloroethene75-35-4U0.005000.005000.000330mg/LU 1 0.000330 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.000350mg/LU 1 0.000350 trans-1,2-dichloroethylene156-60-5U0.005000.005000.000340mg/LU 1 0.000340 1,2-Dichloropropane78-87-5U0.005000.005000.000370mg/LU 1 0.000370 1,3-Dichloropropane142-28-9U0.005000.005000.000330mg/LU 1 0.000330 2,2-Dichloropropane594-20-7U0.005000.005000.000260mg/LU 1 0.000260 1,1-Dichloropropene563-58-6U0.005000.005000.000410mg/LU 1 0.000410 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.000250mg/LU 1 0.000250 trans-1,3-dichloropropene10061-02-6U0.005000.005000.000300mg/LU 1 0.000300 Ethylbenzene100-41-4U0.005000.005000.0000800mg/LU 1 0.0000800 Hexachlorobutadiene87-68-3U0.005000.005000.000560mg/LU 1 0.000560 Isopropylbenzene98-82-8U0.005000.005000.000250mg/LU 1 0.000250 Methylene Chloride75-09-20.004360.005000.005000.000750mg/LJ 1 0.000750 Naphthalene91-20-3U0.01000.01000.000430mg/LU 1 0.000430 n-Propylbenzene103-65-1U0.005000.005000.000180mg/LU 1 0.000180 Styrene100-42-5U0.005000.005000.000140mg/LU 1 0.000140 Page 10 of 34 Final Certificate of Analytical Results 432741 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:615261-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615261-1-BLKDate Collected: Date Received:Dec-06-11 12:53 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:CYE Date Anal:Dec-09-11 14:28 Analyst:CYE Date Prep: Dec-09-11 11:00 Anal seq: 876765Prep seq: 615261 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.000280mg/LU 1 0.000280 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.000420mg/LU 1 0.000420 Tetrachloroethylene127-18-4U0.005000.005000.000590mg/LU 1 0.000590 Toluene108-88-3U0.005000.005000.000490mg/LU 1 0.000490 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.000260mg/LU 1 0.000260 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.000440mg/LU 1 0.000440 1,1,1-Trichloroethane71-55-6U0.005000.005000.000310mg/LU 1 0.000310 1,1,2-Trichloroethane79-00-5U0.005000.005000.000410mg/LU 1 0.000410 Trichloroethylene79-01-6U0.005000.005000.000390mg/LU 1 0.000390 Trichlorofluoromethane75-69-4U0.005000.005000.000330mg/LU 1 0.000330 1,2,3-Trichloropropane96-18-4U0.005000.005000.000590mg/LU 1 0.000590 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.000140mg/LU 1 0.000140 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.000250mg/LU 1 0.000250 o-Xylene95-47-6U0.005000.005000.000310mg/LU 1 0.000310 m,p-Xylenes1330-20-7U0.01000.01000.000470mg/LU 1 0.000470 Vinyl Chloride75-01-4U0.002000.002000.000310mg/LU 1 0.000310 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9774 - 124% Dibromofluoromethane8775 - 131% 1,2-Dichloroethane-D49863 - 144% Toluene-D89780 - 117% Sample Id:615381-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615381-1-BLKDate Collected: Date Received:Dec-06-11 12:53 Analytical Method:Metals, Total by SW846 6010C% Moist:Prep Method: 3010A Tech:4150 Date Anal:Dec-15-11 14:36 Analyst:4150 Date Prep: Dec-14-11 12:21 Anal seq: 877169Prep seq: 615381 Subcontractor: SUB: TX104704477 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-2U0.01000.01000.00400mg/LU 1 0.00400 Barium7440-39-3U0.05000.05000.00200mg/LU 1 0.00200 Cadmium7440-43-9U0.005000.005000.000300mg/LU 1 0.000300 Chromium7440-47-3U0.05000.05000.000300mg/LU 1 0.000300 Lead7439-92-1U0.01000.01000.00330mg/LU 1 0.00330 Selenium7782-49-2U0.01000.01000.0113mg/LU 1 0.0113 Silver7440-22-4U0.05000.05000.000600mg/LU 1 0.000600 Page 11 of 34 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Metals, Total by SW846 6010C Client : Reed Engineering Group, Inc. Work Order #:432741 Project ID: 177921.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 6, 2011Dec. 6, 2011Dec. 14, 20111808Dec.15, 20111801P MW-4 Dec. 6, 2011Dec. 6, 2011Dec. 14, 20111808Dec.15, 20111801P MW-3 Page 12 of 34 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Mercury by SW7470A Client : Reed Engineering Group, Inc. Work Order #:432741 Project ID: 177921.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 6, 2011Dec. 6, 2011Dec.9, 2011283P MW-4 Dec. 6, 2011Dec. 6, 2011Dec.9, 2011283P MW-3 Page 13 of 34 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :VOAs by SW-846 8260B Client : Reed Engineering Group, Inc. Work Order #:432741 Project ID: 177921.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 6, 2011Dec. 6, 2011Dec.9, 2011143P MW-3 Page 14 of 34 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Total Petroleum Hydrocarbons by Texas 1005 Client : Reed Engineering Group, Inc. Work Order #:432741 Project ID: 177921.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 6, 2011Dec. 6, 2011Dec. 9, 2011143Dec.9, 2011140P MW-3 F = These samples were analyzed outside the recommended holding time. P = Samples analyzed within the recommended holding time. Page 15 of 34 Final Flagging Criteria X In our quality control review of the data a QC deficiency was observed and flagged as noted. MS/MSD recoveries were found to be outside of the laboratory control limits due to possible matrix /chemical interference, or a concentration of target analyte high enough to affect the recovery of the spike concentration. This condition could also affect the relative percent difference in the MS/MSD. B A target analyte or common laboratory contaminant was identified in the method blank. Its presence indicates possible field or laboratory contamination. D The sample(s) were diluted due to targets detected over the highest point of the calibration curve, or due to matrix interference. Dilution factors are included in the final results. The result is from a diluted sample. E The data exceeds the upper calibration limit; therefore, the concentration is reported as estimated. F RPD exceeded lab control limits. J The target analyte was positively identified below the quantiation limit and above the detection limit. U Analyte was not detected. L The LCS data for this analytical batch was reported below the laboratory control limits for this analyte. The department supervisor and QA Director reviewed data. The samples were either reanalyzed or flagged as estimated concentrations. H The LCS data for this analytical batch was reported above the laboratory control limits. Supporting QC Data were reviewed by the Department Supervisor and QA Director. Data were determined to be valid for reporting. K Sample analyzed outside of recommended hold time. JN A combination of the "N" and the "J" qualifier. The analysis indicates that the analyte is "tentatively identified" and the associated numerical value may not be consistent with the amount actually present in the environmental sample. * Surrogate recovered outside laboratory control limit. BRL Below Reporting Limit. RL Reporting Limit MDLSDLLOD Method Detection LimitSample Detection LimitLimit of Detection PQLMQLLOQ Practical Quantitation Limit Method Quantitation LimitLimit of Quantitation DL Method Detection Limit NC Non-Calculable + Outside XENCO's scope of NELAC Accreditation. ^NELAC or State program does not offer Accreditation at this time. Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Atlanta - Midland/Odessa - Tamp Phone Fax 4143 Greenbriar Dr, Stafford, TX 77477 (281) 240-4200 (281) 240-4280 9701 Harry Hines Blvd , Dallas, TX 75220 (214) 902 0300 (214) 351-9139 5332 Blackberry Drive, San Antonio TX 78238 (210) 509-3334 (210) 509-3335 2505 North Falkenburg Rd, Tampa, FL 33619 (813) 620-2000 (813) 620-2033 5757 NW 158th St, Miami Lakes, FL 33014 (305) 823-8500 (305) 823-8555 12600 West I-20 East, Odessa, TX 79765 (432) 563-1800 (432) 563-1713 6017 Financial Drive, Norcross, GA 30071 (770) 449-8800 (770) 449-5477 3725 E. Atlanta Ave, Phoenix, AZ 85040 (602) 437-0330 Page 16 of 34 Final Analytical Log Analytical Method:Mercury by SW7470ABatch #:876629 Project Name:---Project ID:177921.1 Client Name:Reed Engineering Group, Inc.WO Number:432741 Client Sample IdLab Sample IdQC Types MW-3 432741-001 SMP MW-4 432741-002 SMP 432687-001 S MS 432687-001 SD MSD 615146-1-BKS BKS 615146-1-BLK BLK 615146-1-BSD BSD Page 17 of 34 Final Analytical Log Analytical Method:Total Petroleum Hydrocarbons by TexaBatch #:876735 Project Name:---Project ID:177921.1 Client Name:Reed Engineering Group, Inc.WO Number:432741 Client Sample IdLab Sample IdQC Types MW-3 432741-001 SMP 615237-1-BKS BKS 615237-1-BLK BLK 615237-1-BSD BSD Page 18 of 34 Final Analytical Log Analytical Method:VOAs by SW-846 8260BBatch #:876765 Project Name:---Project ID:177921.1 Client Name:Reed Engineering Group, Inc.WO Number:432741 Client Sample IdLab Sample IdQC Types MW-3 432741-001 SMP 432760-006 S MS 432760-006 SD MSD 615261-1-BKS BKS 615261-1-BLK BLK Page 19 of 34 Final Analytical Log Analytical Method:Metals, Total by SW846 6010CBatch #:877169 Project Name:---Project ID:177921.1 Client Name:Reed Engineering Group, Inc.WO Number:432741 Client Sample IdLab Sample IdQC Types MW-3 432741-001 SMP MW-4 432741-002 SMP 432760-003 D MD 432760-003 S MS 432760-003 SD MSD 615381-1-BKS BKS 615381-1-BLK BLK 615381-1-BSD BSD Page 20 of 34 Final Form 2 - Surrogate Recoveries --- Project Name: Work Orders :: Project ID 432741,177921.1 876735615237-1-BLK / BLK1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 16:56 Units: AmountTrueControl Total Petroleum Hydrocarbons by Texas 1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 6.7510.06870-130** o-Terphenyl 3.255.006570-130** 876735615237-1-BKS / BKS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 17:18 Units: AmountTrueControl Total Petroleum Hydrocarbons by Texas 1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 7.3310.07370-130 o-Terphenyl 3.685.007470-130 876735615237-1-BSD / BSD1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 17:41 Units: AmountTrueControl Total Petroleum Hydrocarbons by Texas 1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 1-Chlorooctane 6.1810.06270-130** o-Terphenyl 2.835.005770-130** 876765615261-1-BKS / BKS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 13:21 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 4-Bromofluorobenzene 0.04660.05009374-124 Dibromofluoromethane 0.04770.05009575-131 1,2-Dichloroethane-D4 0.05200.050010463-144 Toluene-D8 94 0.04720.050080-117 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 21 of 34 Final Form 2 - Surrogate Recoveries --- Project Name: Work Orders :: Project ID 432741,177921.1 876765615261-1-BLK / BLK1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 14:28 Units: AmountTrueControl VOAs by SW-846 8260B AmountRecoveryLimits FoundFlags [A][B]%R %R [D] Analytes 4-Bromofluorobenzene 0.04870.05009774-124 Dibromofluoromethane 0.04330.05008775-131 1,2-Dichloroethane-D4 0.04920.05009863-144 Toluene-D8 0.04870.05009780-117 876765432760-006 S / MS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 15:24 Units: TrueControl Amount VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04680.05009474-124 Dibromofluoromethane 0.04510.05009075-131 1,2-Dichloroethane-D4 0.04730.05009563-144 Toluene-D8 0.04820.05009680-117 876765432760-006 SD / MSDWater 1 Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/09/11 15:46 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04660.05009374-124 Dibromofluoromethane 0.04540.05009175-131 1,2-Dichloroethane-D4 0.04480.05009063-144 Toluene-D8 0.04790.05009680-117 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 22 of 34 Final Blank Spike Recovery Project Name: --- : Work Order # 432741:177921.1 Project ID Lab Batch #: 876765615261-1-BKSWater Sample:Matrix: 12/09/201112/09/2011 Date Analyzed:Date Prepared:Analyst:CYE Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.0002600.05000.0477 9566-142 Benzene <0.0003900.05000.0470 9475-125 Bromobenzene <0.0004800.05000.0482 9673-125 Bromochloromethane <0.0004200.05000.0467 9375-125 Bromodichloromethane <0.0003400.05000.0481 9675-125 Bromoform <0.0008700.05000.0423 8570-130 Methyl bromide <0.0004300.05000.0546 10965-135 MTBE <0.0001900.05000.0495 9975-125 n-Butylbenzene <0.0001200.05000.0499 10075-125 Sec-Butylbenzene <0.0002000.05000.0504 10175-125 tert-Butylbenzene <0.0001400.05000.0490 9862-125 Carbon Tetrachloride <0.0002700.05000.0459 9260-133 Chlorobenzene <0.0002060.05000.0355 7170-130 Chloroethane <0.0006200.05000.0453 9174-125 Chloroform <0.0004200.05000.0447 8970-130 Methyl Chloride <0.0003000.05000.0487 9773-125 2-Chlorotoluene <0.0002500.05000.0481 9674-125 4-Chlorotoluene <0.0002300.05000.0514 10375-125 p-Cymene (p-Isopropyltoluene) <0.0003500.05000.0462 9273-125 Dibromochloromethane <0.001430.05000.0438 8859-125 1,2-Dibromo-3-Chloropropane <0.0003600.05000.0466 9373-125 1,2-Dibromoethane <0.0004700.05000.0476 9569-127 Methylene bromide <0.0002400.05000.0479 9675-125 1,2-Dichlorobenzene <0.0001900.05000.0478 9675-125 1,3-Dichlorobenzene <0.0003600.05000.0481 9675-125 1,4-Dichlorobenzene <0.0003100.05000.0543 10970-130 Dichlorodifluoromethane <0.0003100.05000.0479 9672-125 1,1-Dichloroethane <0.0002700.05000.0434 8768-127 1,2-Dichloroethane <0.0003300.05000.0511 10259-172 1,1-Dichloroethene <0.0003500.05000.0490 9875-125 cis-1,2-Dichloroethylene <0.0003400.05000.0493 9975-125 trans-1,2-dichloroethylene <0.0003700.05000.0468 9474-125 1,2-Dichloropropane <0.0003300.05000.0451 9075-125 1,3-Dichloropropane Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 23 of 34 Final Blank Spike Recovery Project Name: --- : Work Order # 432741:177921.1 Project ID Lab Batch #: 876765615261-1-BKSWater Sample:Matrix: 12/09/201112/09/2011 Date Analyzed:Date Prepared:Analyst:CYE Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.0002600.05000.0540 10875-125 2,2-Dichloropropane <0.0004100.05000.0453 9175-125 1,1-Dichloropropene <0.0002500.05000.0428 8674-125 cis-1,3-Dichloropropene <0.0003000.05000.0385 7766-125 trans-1,3-dichloropropene <0.00008000.05000.0480 9675-125 Ethylbenzene <0.0005600.05000.0478 9675-125 Hexachlorobutadiene <0.0002500.05000.0512 10275-125 Isopropylbenzene 0.004360.05000.0502 10075-125 Methylene Chloride <0.0004300.05000.0454 9175-125 Naphthalene <0.0001800.05000.0494 9975-125 n-Propylbenzene <0.0001400.05000.0525 10575-125 Styrene <0.0002800.05000.0505 10172-125 1,1,1,2-Tetrachloroethane <0.0004200.05000.0473 9574-125 1,1,2,2-Tetrachloroethane <0.0005900.05000.0451 9071-125 Tetrachloroethylene <0.0004900.05000.0457 9159-139 Toluene <0.0002600.05000.0493 9975-137 1,2,3-Trichlorobenzene <0.0004400.05000.0472 9475-135 1,2,4-Trichlorobenzene <0.0003100.05000.0483 9775-125 1,1,1-Trichloroethane <0.0004100.05000.0454 9175-127 1,1,2-Trichloroethane <0.0003900.05000.0452 9062-137 Trichloroethylene <0.0003300.05000.0509 10267-125 Trichlorofluoromethane <0.0005900.05000.0467 9375-125 1,2,3-Trichloropropane <0.0001400.05000.0504 10175-125 1,2,4-Trimethylbenzene <0.0002500.05000.0501 10070-125 1,3,5-Trimethylbenzene <0.0003100.05000.0503 10175-125 o-Xylene <0.0004700.1000.0983 9875-125 m,p-Xylenes <0.0003100.05000.0419 8475-125 Vinyl Chloride Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 24 of 34 Final BS / BSD Recoveries Project Name:--- Work Order #: 432741 Project ID:177921.1 Date Analyzed: DAT12/09/201112/09/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 876629615146-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY ug/L Units: Mercury by SW7470A BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Mercury <0.03305.004.90 985.004.89 98075-12520 Date Analyzed: 415012/14/201112/15/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 877169615381-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/L Units: Metals, Total by SW846 6010C BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Arsenic <0.004001.000.987 991.000.992 99180-12020 Barium 80-120 <0.002001.000.989 991.000.986 99020 Cadmium 80-120 <0.0003001.000.986 991.000.983 98020 Chromium <0.0003001.000.988 991.000.991 99080-12020 Lead <0.003301.000.982 981.000.980 98080-12020 Selenium <0.01131.001.03 1031.001.02 102180-12020 Silver <0.0006001.000.957 961.000.958 96080-12020 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 25 of 34 Final BS / BSD Recoveries Project Name:--- Work Order #: 432741 Project ID:177921.1 Date Analyzed: JAH12/09/201112/09/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 876735615237-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/L Units: Total Petroleum Hydrocarbons by Texas BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added 1005 [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes C6-C12 Gasoline Range Hydrocarbons <0.99010086.1 8610080.7 81675-12520 C12 - C28 Diesel Range Hydrocarbons <1.4210081.6 8210083.5 84275-12520 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 26 of 34 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 177921.1 432741 Lab Batch ID: 1Water 876629 QC- Sample ID:432687-001 SBatch #:Matrix: 12/09/2011 Date Prepared:Analyst:DAT 12/09/2011 Date Analyzed: Reporting Units:ug/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Mercury by SW7470A Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Mercury<0.03305.004.86975.004.8296175-12520 Lab Batch ID: 1Water 877169 QC- Sample ID:432760-003 SBatch #:Matrix: 12/14/2011 Date Prepared:Analyst:4150 12/15/2011 Date Analyzed: Reporting Units:mg/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Metals, Total by SW846 6010C Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Arsenic <0.004001.000.984981.000.98599080-12020 Barium0.01391.000.957941.000.95594080-12020 Cadmium<0.0003001.000.918921.000.91592080-12020 Chromium0.0008001.000.936941.000.93593080-12020 Lead<0.003301.000.911911.000.90691180-12020 Selenium<0.01131.000.9981001.000.997100080-12020 Silver<0.0006001.000.933931.000.93594080-12020 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 27 of 34 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 177921.1 432741 Lab Batch ID: 1Water 876765 QC- Sample ID:432760-006 SBatch #:Matrix: 12/09/2011 Date Prepared:Analyst:CYE 12/09/2011 Date Analyzed: Reporting Units:mg/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Benzene<0.0002600.05000.05081020.05000.048296566-14225 Bromobenzene <0.0003900.05000.05361070.05000.0486971075-12525 Bromochloromethane<0.0004800.05000.05111020.05000.0463931073-12525 Bromodichloromethane<0.0004200.05000.05261050.05000.048296975-12525 Bromoform<0.0003400.05000.05351070.05000.0475951275-12525 Methyl bromide<0.0008700.05000.0306610.05000.0374752070-13025X MTBE0.002060.05000.05911140.05000.0570110465-13525 n-Butylbenzene<0.0001900.05000.05571110.05000.0518104775-12525 Sec-Butylbenzene <0.0001200.05000.05701140.05000.0536107675-12525 tert-Butylbenzene<0.0002000.05000.05631130.05000.0528106675-12525 Carbon Tetrachloride<0.0001400.05000.04981000.05000.048797262-12525 Chlorobenzene<0.0002700.05000.05111020.05000.048397660-13325 Chloroethane<0.0002060.05000.0323650.05000.0450903370-13025XF Chloroform<0.0006200.05000.0471940.05000.044288674-12525 Methyl Chloride<0.0004200.05000.0332660.05000.0401801970-13025X 2-Chlorotoluene <0.0003000.05000.05381080.05000.0510102573-12525 4-Chlorotoluene<0.0002500.05000.05411080.05000.049699974-12525 p-Cymene (p-Isopropyltoluene)<0.0002300.05000.05761150.05000.0538108775-12525 Dibromochloromethane<0.0003500.05000.05421080.05000.0474951373-12525 1,2-Dibromo-3-Chloropropane<0.001430.05000.0478960.05000.0405811759-12525 1,2-Dibromoethane<0.0003600.05000.05421080.05000.0470941473-12525 Methylene bromide<0.0004700.05000.05071010.05000.0453911169-12725 1,2-Dichlorobenzene <0.0002400.05000.05331070.05000.0503101675-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 28 of 34 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 177921.1 432741 Lab Batch ID: 1Water 876765 QC- Sample ID:432760-006 SBatch #:Matrix: 12/09/2011 Date Prepared:Analyst:CYE 12/09/2011 Date Analyzed: Reporting Units:mg/L Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] 1,3-Dichlorobenzene<0.0001900.05000.05421080.05000.0505101775-12525 1,4-Dichlorobenzene <0.0003600.05000.05321060.05000.0498100775-12525 Dichlorodifluoromethane<0.0003100.05000.0467930.05000.05661131970-13025 1,1-Dichloroethane0.0003600.05000.0497990.05000.048095372-12525 1,2-Dichloroethane<0.0002700.05000.0473950.05000.0421841268-12725 1,1-Dichloroethene0.0005500.05000.05321050.05000.0522103259-17225 cis-1,2-Dichloroethylene0.02190.05000.07171000.05000.070798175-12525 trans-1,2-dichloroethylene0.0004000.05000.0467930.05000.045290375-12525 1,2-Dichloropropane <0.0003700.05000.05001000.05000.045992974-12525 1,3-Dichloropropane<0.0003300.05000.05491100.05000.0481961375-12525 2,2-Dichloropropane<0.0002600.05000.05641130.05000.0561112175-12525 1,1-Dichloropropene<0.0004100.05000.0484970.05000.045190775-12525 cis-1,3-Dichloropropene<0.0002500.05000.0464930.05000.0418841074-12525 trans-1,3-dichloropropene<0.0003000.05000.0442880.05000.0383771466-12525 Ethylbenzene<0.00008000.05000.05291060.05000.049399775-12525 Hexachlorobutadiene <0.0005600.05000.05521100.05000.0525105575-12525 Isopropylbenzene<0.0002500.05000.05431090.05000.0528106375-12525 Methylene Chloride0.004430.05000.0469850.05000.045482375-12525 Naphthalene<0.0004300.05000.05021000.05000.0450901175-12525 n-Propylbenzene<0.0001800.05000.05701140.05000.0530106775-12525 Styrene<0.0001400.05000.05591120.05000.0536107475-12525 1,1,1,2-Tetrachloroethane<0.0002800.05000.05461090.05000.0516103672-12525 1,1,2,2-Tetrachloroethane <0.0004200.05000.05171030.05000.047395974-12525 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 29 of 34 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 177921.1 432741 Lab Batch ID: 1Water 876765 QC- Sample ID:432760-006 SBatch #:Matrix: 12/09/2011 Date Prepared:Analyst:CYE 12/09/2011 Date Analyzed: Reporting Units:mg/L Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Tetrachloroethylene0.1760.05000.221900.05000.21476371-12525 Toluene <0.0004900.05000.05361070.05000.0483971059-13925 1,2,3-Trichlorobenzene<0.0002600.05000.05401080.05000.0502100775-13725 1,2,4-Trichlorobenzene<0.0004400.05000.05181040.05000.047896875-13525 1,1,1-Trichloroethane<0.0003100.05000.05091020.05000.0499100275-12525 1,1,2-Trichloroethane<0.0004100.05000.05161030.05000.0456911275-12725 Trichloroethylene0.03090.05000.0779940.05000.076892162-13725 Trichlorofluoromethane<0.0003300.05000.0445890.05000.05191041567-12525 1,2,3-Trichloropropane <0.0005900.05000.05301060.05000.0456911575-12525 1,2,4-Trimethylbenzene<0.0001400.05000.05711140.05000.0537107675-12525 1,3,5-Trimethylbenzene<0.0002500.05000.05661130.05000.0529106770-12525 o-Xylene<0.0003100.05000.05331070.05000.0513103475-12525 m,p-Xylenes<0.0004700.1000.1081080.1000.101101775-12525 Vinyl Chloride0.002200.05000.0332620.05000.0400761975-12525X Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 30 of 34 Final Sample Duplicate Recovery --- Project Name: Work Order #:432741 177921.1 Project ID: 877169 Lab Batch #: 12/14/2011 Date Prepared:Analyst:4150 12/15/2011 14:43 Date Analyzed: 1Water Batch #:Matrix: QC- Sample ID:432760-003 D SAMPLE / SAMPLE DUPLICATE RECOVERY mg/L Reporting Units: Metals, Total by SW846 6010C SampleControl Parent Sample DuplicateRPDLimits Result Flag Result%RPD [A] [B] Analyte Arsenic <0.004000.00400NC20J Barium0.01390.0127 920J Cadmium<0.000300<0.000300 020U Chromium0.0008000.000500 4620FJ Lead<0.00330<0.00330 020U Selenium <0.0113<0.0113 020U Silver<0.000600<0.000600 020U Spike Relative Difference RPD 200 * | (B-A)/(B+A) | All Results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 31 of 34 Final Page 32 of 34 Final Page 33 of 34 Final XENCO Laboratories Prelogin/Nonconformance Report- Sample Log-In Client:Reed Engineering Group, Inc. Acceptable Temperature Range: 0 - 6 degC Air and Metal samples Acceptable Range: Ambient Date/ Time Received:12/06/2011 12:53:00 PM Temperature Measuring device used : Work Order #:432741 Sample Receipt Checklist Comments #1 *Temperature of cooler(s)?4.7 Yes #2 *Shipping container in good condition? Yes #3 *Samples received on ice? #4 *Custody Seals intact on shipping container/ cooler?No No #5 Custody Seals intact on sample bottles/ container? No #6 *Custody Seals Signed and dated for Containers/coolers Yes #7 *Chain of Custody present? #8 Sample instructions complete on Chain of Custody?Yes No #9 Any missing/extra samples? Yes #10 Chain of Custody signed when relinquished/ received? Yes #11 Chain of Custody agrees with sample label(s)? #12 Container label(s) legible and intact?Yes Yes #13 Sample matrix/ properties agree with Chain of Custody? Yes #14 Samples in proper container/ bottle? Yes #15 Samples properly preserved? #16 Sample container(s) intact?Yes Yes #17 Sufficient sample amount for indicated test(s)? Yes #18 All samples received within hold time? Yes #19 Subcontract of sample(s)?Xenco Houston #20 VOC samples have zero headspace (less than 1/4 inch bubble)?Yes Yes #21 <2 for all samples preserved with HNO3,HCL, H2SO4? N/A #22 >10 for all samples preserved with NaAsO2+NaOH, ZnAc+NaOH? * Must be completed for after-hours delivery of samples prior to placing in the refrigerator Analyst: PH Device/Lot#: NonConformance: Corrective Action Taken: Nonconformance Documentation Contact:Contacted by :DateTime : Checklist completed by: Date:12/07/2011 Angelica Martinez Checklist reviewed by: Date:12/06/2011 Page 34 of 34 Final Analytical Report 433172 for Reed Engineering Group, Inc. Project Manager: Chris McCaslin --- 17792.1 19-DEC-11 Collected By: Client Celebrating 20 Years of commitment to excellence in Environmental Testing Services 9701 Harry Hines Blvd, Dallas, TX 75220 Ph:(214) 902-0300 Fax:(214) 351-9139 Xenco-Houston (EPA Lab code: TX00122): Texas (T104704215-10-6-TX), Arizona (AZ0765), Arkansas (08-039-0), Connecticut (PH-0102), Florida (E871002) Illinois (002082), Indiana (C-TX-02), Iowa (392), Kansas (E-10380), Kentucky (45), Louisiana (03054) New Hampshire (297408), New Jersey (TX007), New York (11763), Oklahoma (9218), Pennsylvania (68-03610) Rhode Island (LAO00312), USDA (S-44102) Xenco-Atlanta (EPA Lab Code: GA00046): Florida (E87429), North Carolina (483), South Carolina (98015), Utah (AALI1), West Virginia (362), Kentucky (85) Louisiana (04176), USDA (P330-07-00105) Xenco-Miami (EPA Lab code: FL01152): Florida (E86678), Maryland (330) Xenco-Tampa Mobile (EPA Lab code: FL01212): Florida (E84900) Xenco-Odessa (EPA Lab code: TX00158): Texas (T104704400-TX) Xenco-Dallas (EPA Lab code: TX01468): Texas (T104704295-TX) Xenco Phoenix (EPA Lab Code: AZ00901): Arizona(AZ0757) Xenco-Phoenix Mobile (EPA Lab code: AZ00901): Arizona (AZM757) Xenco Tucson (EPA Lab code:AZ000989): Arizona (AZ0758) Page 1 of 32 Final 1 Table of Contents Cover Page1 Cover Letter3 Sample ID Cross Reference4 Certificate of Analysis (Detailed Report)5 Holding Time Report11 Explanation of Qualifiers (Flags)15 Analytical Log16 Surrogate Recoveries_QC20 Blank Spike Recoveries22 Blank Spike - Blank Spike Duplicate Recoveries25 Matrix Spike - Matrix Spike Duplicate Recoveries26 Method Duplicate30 coc31 Page 2 of 32 Final 1 19-DEC-11 Chris McCaslin Project Manager: Reed Engineering Group, Inc. 2424 Stutz Drive, Suite 400 Dallas, TX 75235 433172 Reference: XENCO Report No: --- Project Address: - Chris McCaslin : We are reporting to you the results of the analyses performed on the samples received under the project name referenced above and identified with the XENCO Report Number433172. All results being reported under this Report Number apply to the samples analyzed and properly identified with a Laboratory ID number. Subcontracted analyses are identified in this report with either the NELAC certification number of the subcontract lab in the analyst ID field, or the complete subcontracted report attached to this report. Unless otherwise noted in a Case Narrative, all data reported in this Analytical Report are in compliance with NELAC standards. Estimation of data uncertainty for this report is found in the quality control section of this report unless otherwise noted. Should insufficient sample be provided to the laboratory to meet the method and NELAC Matrix Duplicate and Matrix Spike requirements, then the data will be analyzed, evaluated and reported using all other available quality control measures. The validity and integrity of this report will remain intact as long as it is accompanied by this letter and reproduced in full, unless written approval is granted by XENCO Laboratories. This report will be filed for at least 5 years in our archives after which time it will be destroyed without further notice, unless otherwise arranged with you. The samples received, and described as recorded in Report No. 433172 will be filed for 60 days, and after that time they will be properly disposed without further notice, unless otherwise arranged with you. We reserve the right to return to you any unused samples, extracts or solutions related to them if we consider so necessary (e.g., samples identified as hazardous waste, sample sizes exceeding analytical standard practices, controlled substances under regulated protocols, etc). We thank you for selecting XENCO Laboratories to serve your analytical needs. If you have any questions concerning this report, please feel free to contact us at any time. Respectfully, Carlos Castro Managing Director, Texas Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Austin - Tampa - Miami - Atlant Page 3 of 32 Final 1 Sample Cross Reference 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample IdMatrixDate Collected Sample DepthLab Sample Id MW-5W12-12-11 15:4813433172-001 Page 4 of 32 Final 1 Certificate of Analytical Results 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-5Matrix:WaterSample Depth:13 Lab Sample Id:433172-001Date Collected: Dec-12-11 15:48 Date Received:Dec-12-11 16:25 Analytical Method:Metals, Total by SW846 6010CPrep Method: 3010A % Moist: Tech:4150 Date Anal:Dec-15-11 22:34 Analyst:4150 Date Prep: Dec-15-11 08:55 Anal seq: 877184Prep seq: 615418 Subcontractor: SUB: TX104704477 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-20.007500.01000.01000.00400mg/LJ 1 0.00400 Barium7440-39-30.05750.05000.05000.00200mg/L 1 0.00200 Cadmium7440-43-9U0.005000.005000.000300mg/LU 1 0.000300 Chromium0.000700 7440-47-30.05000.05000.000300mg/LJ 1 0.000300 Lead7439-92-10.006700.01000.01000.00330mg/LJ 1 0.00330 Selenium7782-49-2U0.01000.01000.0113mg/LU 1 0.0113 Silver0.00130 7440-22-40.05000.05000.000600mg/LJ 1 0.000600 Mercury by SW7470A% Moist:Prep Method: Tech:DAT Date Anal:Dec-16-11 07:48 Analyst:DAT Date Prep: Dec-15-11 08:00 Anal seq: 877168Prep seq: 615421 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-6U0.1000.1000.0330ug/LU 1 0.0330 TPH by Texas1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-15-11 18:46 Analyst:JAH Date Prep: Dec-15-11 16:27 Anal seq: 877206Prep seq: 615516 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons PHC612U5.004.520.990mg/LU 1 0.895 C12-C28 Diesel Range HydrocarbonsPHCG1028U5.004.521.42mg/LU 1 1.28 C28-C35 Oil Range HydrocarbonsPHCG2835U5.004.521.50mg/LU 1 1.36 Total TPH 1005PHC635Umg/LU Surrogate% RecLimitsUnitsFlag 1-Chlorooctane 10070 - 130% o-Terphenyl10070 - 130% Page 5 of 32 Final 1 Certificate of Analytical Results 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-5Matrix:WaterSample Depth:13 Lab Sample Id:433172-001Date Collected: Dec-12-11 15:48 Date Received:Dec-12-11 16:25 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:JBU Date Anal:Dec-13-11 17:59 Analyst:JBU Date Prep: Dec-13-11 14:55 Anal seq: 876994Prep seq: 615395 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.00100mg/LU 1 0.00100 Bromobenzene108-86-1U0.005000.005000.00100mg/LU 1 0.00100 Bromochloromethane74-97-5U0.005000.005000.00100mg/LU 1 0.00100 Bromodichloromethane 75-27-4U0.005000.005000.00100mg/LU 1 0.00100 Bromoform75-25-2U0.005000.005000.00100mg/LU 1 0.00100 Methyl bromide74-83-9U0.005000.005000.00100mg/LU 1 0.00100 MTBE1634-04-4U0.005000.005000.00100mg/LU 1 0.00100 n-Butylbenzene104-51-8U0.005000.005000.00100mg/LU 1 0.00100 Sec-Butylbenzene135-98-8U0.005000.005000.00100mg/LU 1 0.00100 tert-Butylbenzene98-06-6U0.005000.005000.00100mg/LU 1 0.00100 Carbon Tetrachloride56-23-5U0.005000.005000.00100mg/LU 1 0.00100 Chlorobenzene108-90-7U0.005000.005000.00100mg/LU 1 0.00100 Chloroethane75-00-3U0.01000.01000.00200mg/LU 1 0.00200 Chloroform67-66-3U0.005000.005000.00100mg/LU 1 0.00100 Methyl Chloride74-87-3U0.01000.01000.00200mg/LU 1 0.00200 2-Chlorotoluene95-49-8U0.005000.005000.00100mg/LU 1 0.00100 4-Chlorotoluene106-43-4U0.005000.005000.00100mg/LU 1 0.00100 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.00100mg/LU 1 0.00100 Dibromochloromethane124-48-1U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00224mg/LU 1 0.00224 1,2-Dibromoethane106-93-4U0.005000.005000.00100mg/LU 1 0.00100 Methylene bromide74-95-3U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dichlorobenzene95-50-1U0.005000.005000.00100mg/LU 1 0.00100 1,3-Dichlorobenzene541-73-1U0.005000.005000.00100mg/LU 1 0.00100 1,4-Dichlorobenzene106-46-7U0.005000.005000.00100mg/LU 1 0.00100 Dichlorodifluoromethane75-71-8U0.005000.005000.00100mg/LU 1 0.00100 1,1-Dichloroethane75-34-3U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dichloroethane107-06-2U0.005000.005000.00100mg/LU 1 0.00100 1,1-Dichloroethene75-35-4U0.005000.005000.00100mg/LU 1 0.00100 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.00100mg/LU 1 0.00100 trans-1,2-dichloroethylene156-60-5U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dichloropropane78-87-5U0.005000.005000.00100mg/LU 1 0.00100 1,3-Dichloropropane142-28-9U0.005000.005000.00100mg/LU 1 0.00100 2,2-Dichloropropane594-20-7U0.005000.005000.00100mg/LU 1 0.00100 1,1-Dichloropropene563-58-6U0.005000.005000.00100mg/LU 1 0.00100 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.00100mg/LU 1 0.00100 trans-1,3-dichloropropene10061-02-6U0.005000.005000.00100mg/LU 1 0.00100 Ethylbenzene100-41-4U0.005000.005000.00100mg/LU 1 0.00100 Hexachlorobutadiene87-68-3U0.005000.005000.00100mg/LU 1 0.00100 Isopropylbenzene98-82-8U0.005000.005000.00100mg/LU 1 0.00100 Methylene Chloride75-09-2U0.01000.01000.00500mg/LU 1 0.00500 Naphthalene91-20-3U0.01000.01000.00200mg/LUH 1 0.00200 n-Propylbenzene103-65-1U0.005000.005000.00100mg/LU 1 0.00100 Styrene100-42-5U0.005000.005000.00100mg/LU 1 0.00100 Page 6 of 32 Final 1 Certificate of Analytical Results 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:MW-5Matrix:WaterSample Depth:13 Lab Sample Id:433172-001Date Collected: Dec-12-11 15:48 Date Received:Dec-12-11 16:25 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:JBU Date Anal:Dec-13-11 17:59 Analyst:JBU Date Prep: Dec-13-11 14:55 Anal seq: 876994Prep seq: 615395 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.00100mg/LU 1 0.00100 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.00100mg/LU 1 0.00100 Tetrachloroethylene127-18-4U0.005000.005000.00100mg/LU 1 0.00100 Toluene 108-88-3U0.005000.005000.00100mg/LU 1 0.00100 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.00100mg/LU 1 0.00100 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.00100mg/LU 1 0.00100 1,1,1-Trichloroethane71-55-6U0.005000.005000.00100mg/LU 1 0.00100 1,1,2-Trichloroethane79-00-5U0.005000.005000.00100mg/LU 1 0.00100 Trichloroethylene79-01-6U0.005000.005000.00100mg/LU 1 0.00100 Trichlorofluoromethane75-69-4U0.005000.005000.00100mg/LU 1 0.00100 1,2,3-Trichloropropane96-18-4U0.005000.005000.000822mg/LU 1 0.000822 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.00100mg/LU 1 0.00100 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.00100mg/LU 1 0.00100 o-Xylene95-47-6U0.005000.005000.00100mg/LU 1 0.00100 m,p-Xylenes1330-20-7U0.01000.01000.00200mg/LU 1 0.00200 Vinyl Chloride75-01-4U0.002000.002000.000400mg/LU 1 0.000400 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9874 - 124% Dibromofluoromethane10175 - 131% 1,2-Dichloroethane-D49863 - 144% Toluene-D810080 - 117% Page 7 of 32 Final 1 Certificate of Analytical Results 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:615395-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615395-1-BLKDate Collected: Date Received:Dec-12-11 16:25 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:JBU Date Anal:Dec-13-11 11:38 Analyst:JBU Date Prep: Dec-13-11 14:00 Anal seq: 876994Prep seq: 615395 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Benzene71-43-2U0.005000.005000.00100mg/LU 1 0.00100 Bromobenzene108-86-1U0.005000.005000.00100mg/LU 1 0.00100 Bromochloromethane74-97-5U0.005000.005000.00100mg/LU 1 0.00100 Bromodichloromethane 75-27-4U0.005000.005000.00100mg/LU 1 0.00100 Bromoform75-25-2U0.005000.005000.00100mg/LU 1 0.00100 Methyl bromide74-83-9U0.005000.005000.00100mg/LU 1 0.00100 MTBE1634-04-4U0.005000.005000.00100mg/LU 1 0.00100 n-Butylbenzene104-51-8U0.005000.005000.00100mg/LU 1 0.00100 Sec-Butylbenzene135-98-8U0.005000.005000.00100mg/LU 1 0.00100 tert-Butylbenzene98-06-6U0.005000.005000.00100mg/LU 1 0.00100 Carbon Tetrachloride56-23-5U0.005000.005000.00100mg/LU 1 0.00100 Chlorobenzene108-90-7U0.005000.005000.00100mg/LU 1 0.00100 Chloroethane75-00-3U0.01000.01000.00200mg/LU 1 0.00200 Chloroform67-66-3U0.005000.005000.00100mg/LU 1 0.00100 Methyl Chloride74-87-3U0.01000.01000.00200mg/LU 1 0.00200 2-Chlorotoluene95-49-8U0.005000.005000.00100mg/LU 1 0.00100 4-Chlorotoluene106-43-4U0.005000.005000.00100mg/LU 1 0.00100 p-Cymene (p-Isopropyltoluene)99-87-6U0.005000.005000.00100mg/LU 1 0.00100 Dibromochloromethane124-48-1U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dibromo-3-Chloropropane96-12-8U0.005000.005000.00224mg/LU 1 0.00224 1,2-Dibromoethane106-93-4U0.005000.005000.00100mg/LU 1 0.00100 Methylene bromide74-95-3U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dichlorobenzene95-50-1U0.005000.005000.00100mg/LU 1 0.00100 1,3-Dichlorobenzene541-73-1U0.005000.005000.00100mg/LU 1 0.00100 1,4-Dichlorobenzene106-46-7U0.005000.005000.00100mg/LU 1 0.00100 Dichlorodifluoromethane75-71-8U0.005000.005000.00100mg/LU 1 0.00100 1,1-Dichloroethane75-34-3U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dichloroethane107-06-2U0.005000.005000.00100mg/LU 1 0.00100 1,1-Dichloroethene75-35-4U0.005000.005000.00100mg/LU 1 0.00100 cis-1,2-Dichloroethylene156-59-2U0.005000.005000.00100mg/LU 1 0.00100 trans-1,2-dichloroethylene156-60-5U0.005000.005000.00100mg/LU 1 0.00100 1,2-Dichloropropane78-87-5U0.005000.005000.00100mg/LU 1 0.00100 1,3-Dichloropropane142-28-9U0.005000.005000.00100mg/LU 1 0.00100 2,2-Dichloropropane594-20-7U0.005000.005000.00100mg/LU 1 0.00100 1,1-Dichloropropene563-58-6U0.005000.005000.00100mg/LU 1 0.00100 cis-1,3-Dichloropropene10061-01-5U0.005000.005000.00100mg/LU 1 0.00100 trans-1,3-dichloropropene10061-02-6U0.005000.005000.00100mg/LU 1 0.00100 Ethylbenzene100-41-4U0.005000.005000.00100mg/LU 1 0.00100 Hexachlorobutadiene87-68-3U0.005000.005000.00100mg/LU 1 0.00100 Isopropylbenzene98-82-8U0.005000.005000.00100mg/LU 1 0.00100 Methylene Chloride75-09-2U0.01000.01000.00500mg/LU 1 0.00500 Naphthalene91-20-3U0.01000.01000.00200mg/LU 1 0.00200 n-Propylbenzene103-65-1U0.005000.005000.00100mg/LU 1 0.00100 Styrene100-42-5U0.005000.005000.00100mg/LU 1 0.00100 Page 8 of 32 Final 1 Certificate of Analytical Results 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:615395-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615395-1-BLKDate Collected: Date Received:Dec-12-11 16:25 Analytical Method:VOAs by SW-846 8260BPrep Method: 5030B % Moist: Tech:JBU Date Anal:Dec-13-11 11:38 Analyst:JBU Date Prep: Dec-13-11 14:00 Anal seq: 876994Prep seq: 615395 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj 1,1,1,2-Tetrachloroethane630-20-6U0.005000.005000.00100mg/LU 1 0.00100 1,1,2,2-Tetrachloroethane79-34-5U0.005000.005000.00100mg/LU 1 0.00100 Tetrachloroethylene127-18-4U0.005000.005000.00100mg/LU 1 0.00100 Toluene108-88-3U0.005000.005000.00100mg/LU 1 0.00100 1,2,3-Trichlorobenzene87-61-6U0.005000.005000.00100mg/LU 1 0.00100 1,2,4-Trichlorobenzene120-82-1U0.005000.005000.00100mg/LU 1 0.00100 1,1,1-Trichloroethane71-55-6U0.005000.005000.00100mg/LU 1 0.00100 1,1,2-Trichloroethane79-00-5U0.005000.005000.00100mg/LU 1 0.00100 Trichloroethylene79-01-6U0.005000.005000.00100mg/LU 1 0.00100 Trichlorofluoromethane75-69-4U0.005000.005000.00100mg/LU 1 0.00100 1,2,3-Trichloropropane96-18-4U0.005000.005000.000822mg/LU 1 0.000822 1,2,4-Trimethylbenzene95-63-6U0.005000.005000.00100mg/LU 1 0.00100 1,3,5-Trimethylbenzene108-67-8U0.005000.005000.00100mg/LU 1 0.00100 o-Xylene95-47-6U0.005000.005000.00100mg/LU 1 0.00100 m,p-Xylenes1330-20-7U0.01000.01000.00200mg/LU 1 0.00200 Vinyl Chloride75-01-4U0.002000.002000.000400mg/LU 1 0.000400 Surrogate% RecLimitsUnitsFlag 4-Bromofluorobenzene9874 - 124% Dibromofluoromethane9975 - 131% 1,2-Dichloroethane-D410363 - 144% Toluene-D810180 - 117% Sample Id:615418-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615418-1-BLKDate Collected: Date Received:Dec-12-11 16:25 Analytical Method:Metals, Total by SW846 6010C% Moist:Prep Method: 3010A Tech:4150 Date Anal:Dec-15-11 22:01 Analyst:4150 Date Prep: Dec-15-11 08:55 Anal seq: 877184Prep seq: 615418 Subcontractor: SUB: TX104704477 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Arsenic7440-38-2U0.01000.01000.00400mg/LU 1 0.00400 Barium7440-39-3U0.05000.05000.00200mg/LU 1 0.00200 Cadmium7440-43-9U0.005000.005000.000300mg/LU 1 0.000300 Chromium7440-47-3U0.05000.05000.000300mg/LU 1 0.000300 Lead7439-92-1U0.01000.01000.00330mg/LU 1 0.00330 Selenium7782-49-2U0.01000.01000.0113mg/LU 1 0.0113 Silver7440-22-4U0.05000.05000.000600mg/LU 1 0.000600 Page 9 of 32 Final 1 Certificate of Analytical Results 433172 Reed Engineering Group, Inc., Dallas, TX --- Sample Id:615421-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615421-1-BLKDate Collected: Date Received:Dec-12-11 16:25 Analytical Method:Mercury by SW7470APrep Method: % Moist: Tech:DAT Date Anal:Dec-16-11 07:44 Analyst:DAT Date Prep: Dec-15-11 08:00 Anal seq: 877168Prep seq: 615421 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj Mercury7439-97-6U0.1000.1000.0330ug/LU 1 0.0330 Sample Id:615516-1-BLKMatrix:WaterSample Depth: Lab Sample Id:615516-1-BLKDate Collected: Date Received:Dec-12-11 16:25 Analytical Method:TPH by Texas1005% Moist:Prep Method: 1005 Tech:JAH Date Anal:Dec-15-11 17:42 Analyst:JAH Date Prep: Dec-15-11 16:18 Anal seq: 877206Prep seq: 615516 Subcontractor: SUB: TX104704215 CAS MQLMQL MDL ParameterResultSDLUnitsFlagDil NumberUnAdjAdjUnAdj C6-C12 Gasoline Range Hydrocarbons 0.990mg/L PHC612U5.005.00U 1 0.990 C12-C28 Diesel Range HydrocarbonsPHCG1028U5.005.001.42mg/LU 1 1.42 C28-C35 Oil Range HydrocarbonsPHCG2835U5.005.001.50mg/LU 1 1.50 Surrogate% RecLimitsUnitsFlag 1-Chlorooctane8570 - 130% o-Terphenyl9270 - 130% Page 10 of 32 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Metals, Total by SW846 6010C Client : Reed Engineering Group, Inc. Work Order #:433172 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 12, 2011Dec. 12, 2011Dec. 15, 20111803Dec.15, 20111800P MW-5 Page 11 of 32 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :Mercury by SW7470A Client : Reed Engineering Group, Inc. Work Order #:433172 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 12, 2011Dec. 12, 2011Dec.16, 2011284P MW-5 Page 12 of 32 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :VOAs by SW-846 8260B Client : Reed Engineering Group, Inc. Work Order #:433172 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 12, 2011Dec. 12, 2011Dec.13, 2011141P MW-5 Page 13 of 32 Final XENCO Laboratories CHRONOLOGY OF HOLDING TIMES Analytical Method :TPH by Texas1005 Client : Reed Engineering Group, Inc. Work Order #:433172 Project ID: 17792.1 Time MaxTimeMax Held Field Sample IDDateHoldingHeldDateHoldingQ Date Date Analyzed Received TimeExtracteAnalyzedTime Extracted Collected (Days) ExtracteddAnalyzed (Days)(Days)(Days) Dec. 12, 2011Dec. 12, 2011Dec. 15, 2011143Dec.15, 2011140P MW-5 F = These samples were analyzed outside the recommended holding time. P = Samples analyzed within the recommended holding time. Page 14 of 32 Final Flagging Criteria X In our quality control review of the data a QC deficiency was observed and flagged as noted. MS/MSD recoveries were found to be outside of the laboratory control limits due to possible matrix /chemical interference, or a concentration of target analyte high enough to affect the recovery of the spike concentration. This condition could also affect the relative percent difference in the MS/MSD. B A target analyte or common laboratory contaminant was identified in the method blank. Its presence indicates possible field or laboratory contamination. D The sample(s) were diluted due to targets detected over the highest point of the calibration curve, or due to matrix interference. Dilution factors are included in the final results. The result is from a diluted sample. E The data exceeds the upper calibration limit; therefore, the concentration is reported as estimated. F RPD exceeded lab control limits. J The target analyte was positively identified below the quantiation limit and above the detection limit. U Analyte was not detected. L The LCS data for this analytical batch was reported below the laboratory control limits for this analyte. The department supervisor and QA Director reviewed data. The samples were either reanalyzed or flagged as estimated concentrations. H The LCS data for this analytical batch was reported above the laboratory control limits. Supporting QC Data were reviewed by the Department Supervisor and QA Director. Data were determined to be valid for reporting. K Sample analyzed outside of recommended hold time. JN A combination of the "N" and the "J" qualifier. The analysis indicates that the analyte is "tentatively identified" and the associated numerical value may not be consistent with the amount actually present in the environmental sample. * Surrogate recovered outside laboratory control limit. BRL Below Reporting Limit. RL Reporting Limit MDLSDLLOD Method Detection LimitSample Detection LimitLimit of Detection PQLMQLLOQ Practical Quantitation Limit Method Quantitation LimitLimit of Quantitation DL Method Detection Limit NC Non-Calculable + Outside XENCO's scope of NELAC Accreditation. ^NELAC or State program does not offer Accreditation at this time. Recipient of the Prestigious Small Business Administration Award Certified and approved by numerous States and Agencies. A Small Business and Minority Status Company that delivers SERVI Houston - Dallas - San Antonio - Atlanta - Midland/Odessa - Tamp Phone Fax 4143 Greenbriar Dr, Stafford, TX 77477 (281) 240-4200 (281) 240-4280 9701 Harry Hines Blvd , Dallas, TX 75220 (214) 902 0300 (214) 351-9139 5332 Blackberry Drive, San Antonio TX 78238 (210) 509-3334 (210) 509-3335 2505 North Falkenburg Rd, Tampa, FL 33619 (813) 620-2000 (813) 620-2033 5757 NW 158th St, Miami Lakes, FL 33014 (305) 823-8500 (305) 823-8555 12600 West I-20 East, Odessa, TX 79765 (432) 563-1800 (432) 563-1713 6017 Financial Drive, Norcross, GA 30071 (770) 449-8800 (770) 449-5477 3725 E. Atlanta Ave, Phoenix, AZ 85040 (602) 437-0330 Page 15 of 32 Final Analytical Log Analytical Method:VOAs by SW-846 8260BBatch #:876994 Project Name:---Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:433172 Client Sample IdLab Sample IdQC Types MW-5 433172-001 SMP 433173-001 S MS 433173-001 SD MSD 615395-1-BKS BKS 615395-1-BLK BLK Page 16 of 32 Final Analytical Log Analytical Method:Mercury by SW7470ABatch #:877168 Project Name:---Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:433172 Client Sample IdLab Sample IdQC Types MW-5 433172-001 SMP 433172-001 S MS 433172-001 SD MSD 615421-1-BKS BKS 615421-1-BLK BLK 615421-1-BSD BSD Page 17 of 32 Final Analytical Log Analytical Method:Metals, Total by SW846 6010CBatch #:877184 Project Name:---Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:433172 Client Sample IdLab Sample IdQC Types MW-5 433172-001 SMP 433064-007 D MD 433064-007 S MS 433064-007 SD MSD 615418-1-BKS BKS 615418-1-BLK BLK 615418-1-BSD BSD Page 18 of 32 Final Analytical Log Analytical Method:TPH by Texas1005Batch #:877206 Project Name:---Project ID:17792.1 Client Name:Reed Engineering Group, Inc.WO Number:433172 Client Sample IdLab Sample IdQC Types MW-5 433172-001 SMP 615516-1-BKS BKS 615516-1-BLK BLK Page 19 of 32 Final Form 2 - Surrogate Recoveries --- Project Name: Work Orders :: Project ID 433172,17792.1 877206615516-1-BLK / BLK1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/15/11 17:42 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 8.5110.08570-130 o-Terphenyl 4.585.009270-130 877206615516-1-BKS / BKS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/15/11 18:02 Units: AmountTrueControl TPH by Texas1005 FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 1-Chlorooctane 10.810.010870-130 o-Terphenyl 5.525.0011070-130 876994615395-1-BKS / BKS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/13/11 10:55 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R [D] Analytes 4-Bromofluorobenzene 0.05010.050010074-124 Dibromofluoromethane 0.04900.05009875-131 1,2-Dichloroethane-D4 0.05190.050010463-144 Toluene-D8 0.05020.050010080-117 876994615395-1-BLK / BLK1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/13/11 11:38 Units: Amount TrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04910.05009874-124 Dibromofluoromethane 0.04930.05009975-131 1,2-Dichloroethane-D4 0.05160.050010363-144 Toluene-D8 0.05030.050010180-117 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 20 of 32 Final Form 2 - Surrogate Recoveries --- Project Name: Work Orders :: Project ID 433172,17792.1 876994433173-001 S / MS1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/13/11 18:19 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04840.05009774-124 Dibromofluoromethane 0.05090.050010275-131 1,2-Dichloroethane-D4 0.05130.050010363-144 Toluene-D8 0.04980.050010080-117 876994433173-001 SD / MSD1Water Matrix: Lab Batch #:Sample:Batch: SURROGATE RECOVERY STUDY Date Analyzed: mg/L12/13/11 18:39 Units: AmountTrueControl VOAs by SW-846 8260B FoundAmountRecoveryLimitsFlags [A][B]%R %R Analytes[D] 4-Bromofluorobenzene 0.04990.050010074-124 Dibromofluoromethane 0.05010.050010075-131 1,2-Dichloroethane-D4 0.05010.050010063-144 Toluene-D8 0.04960.05009980-117 * Surrogate outside of Laboratory QC limits ** Surrogates outside limits; data and surrogates confirmed by reanalysis *** Poor recoveries due to dilution Surrogate Recovery [D] = 100 * A / B All results are based on MDL and validated for QC purposes. Page 21 of 32 Final Blank Spike Recovery Project Name: --- : Work Order # 433172:17792.1 Project ID Lab Batch #: 877206615516-1-BKSWater Sample:Matrix: 12/15/201112/15/2011 Date Analyzed:Date Prepared:Analyst:JAH Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl TPH by Texas1005 ResultAddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.990100108 10875-125 C6-C12 Gasoline Range Hydrocarbons <1.42100106 10675-125 C12-C28 Diesel Range Hydrocarbons Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 22 of 32 Final Blank Spike Recovery Project Name: --- : Work Order # 433172:17792.1 Project ID Lab Batch #: 876994615395-1-BKSWater Sample:Matrix: 12/13/201112/13/2011 Date Analyzed:Date Prepared:Analyst:JBU Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.001000.05000.0514 10366-142 Benzene <0.001000.05000.0515 10375-125 Bromobenzene <0.001000.05000.0503 10173-125 Bromochloromethane <0.001000.05000.0509 10275-125 Bromodichloromethane <0.001000.05000.0515 10375-125 Bromoform <0.001000.05000.0511 10270-130 Methyl bromide <0.001000.05000.0505 10165-135 MTBE <0.001000.05000.0535 10775-125 n-Butylbenzene <0.001000.05000.0522 10475-125 Sec-Butylbenzene <0.001000.05000.0527 10575-125 tert-Butylbenzene <0.001000.05000.0524 10562-125 Carbon Tetrachloride <0.001000.05000.0512 10260-133 Chlorobenzene <0.002000.05000.0527 10570-130 Chloroethane <0.001000.05000.0509 10274-125 Chloroform <0.002000.05000.0525 10570-130 Methyl Chloride <0.001000.05000.0521 10473-125 2-Chlorotoluene <0.001000.05000.0522 10474-125 4-Chlorotoluene <0.001000.05000.0531 10675-125 p-Cymene (p-Isopropyltoluene) <0.001000.05000.0510 10273-125 Dibromochloromethane <0.002240.05000.0521 10459-125 1,2-Dibromo-3-Chloropropane <0.001000.05000.0507 10173-125 1,2-Dibromoethane <0.001000.05000.0504 10169-127 Methylene bromide <0.001000.05000.0511 10275-125 1,2-Dichlorobenzene <0.001000.05000.0507 10175-125 1,3-Dichlorobenzene <0.001000.05000.0518 10475-125 1,4-Dichlorobenzene <0.001000.05000.0542 10870-130 Dichlorodifluoromethane <0.001000.05000.0508 10272-125 1,1-Dichloroethane <0.001000.05000.0501 10068-127 1,2-Dichloroethane <0.001000.05000.0521 10459-172 1,1-Dichloroethene <0.001000.05000.0510 10275-125 cis-1,2-Dichloroethylene <0.001000.05000.0507 10175-125 trans-1,2-dichloroethylene <0.001000.05000.0504 10174-125 1,2-Dichloropropane <0.001000.05000.0504 10175-125 1,3-Dichloropropane Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 23 of 32 Final Blank Spike Recovery Project Name: --- : Work Order # 433172:17792.1 Project ID Lab Batch #: 876994615395-1-BKSWater Sample:Matrix: 12/13/201112/13/2011 Date Analyzed:Date Prepared:Analyst:JBU Reporting Units:BLANK /BLANK SPIKE RECOVERY STUDY mg/L1 Batch #: BlankSpikeBlankBlankControl VOAs by SW-846 8260B Result AddedSpikeSpikeLimits Flags [A][B] Result%R %R Analytes [C][D] <0.001000.05000.0531 10675-125 2,2-Dichloropropane <0.001000.05000.0520 10475-125 1,1-Dichloropropene <0.001000.05000.0514 10374-125 cis-1,3-Dichloropropene <0.001000.05000.0519 10466-125 trans-1,3-dichloropropene <0.001000.05000.0517 10375-125 Ethylbenzene <0.001000.05000.0567 11375-125 Hexachlorobutadiene <0.001000.05000.0517 10375-125 Isopropylbenzene <0.005000.05000.0486 9750-144 Methylene Chloride <0.002000.05000.0658 13275-125H Naphthalene <0.001000.05000.0523 10575-125 n-Propylbenzene <0.001000.05000.0519 10475-125 Styrene <0.001000.05000.0510 10272-125 1,1,1,2-Tetrachloroethane <0.001000.05000.0509 10274-125 1,1,2,2-Tetrachloroethane <0.001000.05000.0511 10271-125 Tetrachloroethylene <0.001000.05000.0509 10259-139 Toluene <0.001000.05000.0611 12275-137 1,2,3-Trichlorobenzene <0.001000.05000.0611 12275-135 1,2,4-Trichlorobenzene <0.001000.05000.0513 10375-125 1,1,1-Trichloroethane <0.001000.05000.0499 10075-127 1,1,2-Trichloroethane <0.001000.05000.0518 10462-137 Trichloroethylene <0.001000.05000.0526 10567-125 Trichlorofluoromethane <0.0008220.05000.0513 10375-125 1,2,3-Trichloropropane <0.001000.05000.0523 10575-125 1,2,4-Trimethylbenzene <0.001000.05000.0522 10470-125 1,3,5-Trimethylbenzene <0.001000.05000.0518 10475-125 o-Xylene <0.002000.1000.103 10375-125 m,p-Xylenes <0.0004000.05000.0521 10475-125 Vinyl Chloride Blank Spike Recovery [D] = 100*[C]/[B] All results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 24 of 32 Final BS / BSD Recoveries Project Name:--- Work Order #: 433172 Project ID:17792.1 Date Analyzed: DAT12/15/201112/16/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 877168615421-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY ug/L Units: Mercury by SW7470A BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Mercury <0.03305.005.28 1065.005.42 108375-12520 Date Analyzed: 415012/15/201112/15/2011 Analyst:Date Prepared: Water Matrix: Lab Batch ID:Sample:Batch #: 877184615418-1-BKS1 BLANK /BLANK SPIKE / BLANK SPIKE DUPLICATE RECOVERY STUDY mg/L Units: Metals, Total by SW846 6010C BlankSpikeBlankBlankBlankBlk. SpkControlControl Spike Sample ResultAddedSpikeSpikeSpike Dup.RPDLimitsLimitsFlag Added [A] Result%RDuplicate%R% %R%RPD [B][C][D]Result [F][G] [E] Analytes Arsenic <0.004001.000.945 951.000.936 94180-12020 Barium 80-120 <0.002001.000.944 941.000.931 93120 Cadmium 80-120 <0.0003001.000.939 941.000.929 93120 Chromium <0.0003001.000.939 941.000.920 92280-12020 Lead <0.003301.000.935 941.000.925 93180-12020 Selenium <0.01131.000.978 981.000.970 97180-12020 Silver <0.0006001.000.898 901.000.888 89180-12020 Relative Percent Difference RPD = 200*|(C-F)/(C+F)| Blank Spike Recovery [D] = 100*(C)/[B] Blank Spike Duplicate Recovery [G] = 100*(F)/[E] All results are based on MDL and Validated for QC Purposes Page 25 of 32 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 17792.1 433172 Lab Batch ID: 1Water 877168 QC- Sample ID:433172-001 SBatch #:Matrix: 12/15/2011 Date Prepared:Analyst:DAT 12/16/2011 Date Analyzed: Reporting Units:ug/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Mercury by SW7470A Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Mercury<0.03305.005.011005.004.8697375-12520 Lab Batch ID: 1Water 877184 QC- Sample ID:433064-007 SBatch #:Matrix: 12/15/2011 Date Prepared:Analyst:4150 12/15/2011 Date Analyzed: Reporting Units:mg/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl Metals, Total by SW846 6010C Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Arsenic <0.004001.000.970971.000.95896180-12020 Barium0.01051.000.937931.000.92391280-12020 Cadmium<0.0003001.000.892891.000.88088180-12020 Chromium0.0009001.000.912911.000.89990180-12020 Lead<0.003301.000.885891.000.87487180-12020 Selenium<0.01131.000.987991.000.97497180-12020 Silver<0.0006001.000.900901.000.88589280-12020 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 26 of 32 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 17792.1 433172 Lab Batch ID: 1Water 876994 QC- Sample ID:433173-001 SBatch #:Matrix: 12/13/2011 Date Prepared:Analyst:JBU 12/13/2011 Date Analyzed: Reporting Units:mg/L MATRIX SPIKE / MATRIX SPIKE DUPLICATE RECOVERY STUDY Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Benzene<0.001000.05000.05411080.05000.0512102666-14221 Bromobenzene <0.001000.05000.05321060.05000.0509102475-12520 Bromochloromethane<0.001000.05000.05521100.05000.0510102873-12520 Bromodichloromethane<0.001000.05000.05481100.05000.0511102775-12520 Bromoform<0.001000.05000.05431090.05000.0506101775-12520 Methyl bromide<0.001000.05000.05021000.05000.045992970-13020 MTBE<0.001000.05000.05131030.05000.047795765-13520 n-Butylbenzene<0.001000.05000.05441090.05000.0527105375-12520 Sec-Butylbenzene <0.001000.05000.05331070.05000.0517103375-12520 tert-Butylbenzene<0.001000.05000.05291060.05000.0508102475-12520 Carbon Tetrachloride<0.001000.05000.05491100.05000.0521104562-12520 Chlorobenzene<0.001000.05000.05401080.05000.0502100760-13321 Chloroethane<0.002000.05000.05411080.05000.0511102670-13020 Chloroform<0.001000.05000.05511100.05000.0515103774-12520 Methyl Chloride<0.002000.05000.0482960.05000.045290670-13020 2-Chlorotoluene <0.001000.05000.05301060.05000.0509102473-12520 4-Chlorotoluene<0.001000.05000.05241050.05000.0510102374-12520 p-Cymene (p-Isopropyltoluene)<0.001000.05000.05341070.05000.0517103375-12520 Dibromochloromethane<0.001000.05000.05411080.05000.0508102673-12520 1,2-Dibromo-3-Chloropropane<0.002240.05000.05391080.05000.0527105259-12528 1,2-Dibromoethane<0.001000.05000.05451090.05000.0507101773-12520 Methylene bromide<0.001000.05000.05421080.05000.0506101769-12723 1,2-Dichlorobenzene <0.001000.05000.05381080.05000.0519104475-12520 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 27 of 32 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 17792.1 433172 Lab Batch ID: 1Water 876994 QC- Sample ID:433173-001 SBatch #:Matrix: 12/13/2011 Date Prepared:Analyst:JBU 12/13/2011 Date Analyzed: Reporting Units:mg/L Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] 1,3-Dichlorobenzene<0.001000.05000.05271050.05000.0503101575-12520 1,4-Dichlorobenzene <0.001000.05000.05381080.05000.0518104475-12520 Dichlorodifluoromethane<0.001000.05000.05941190.05000.0547109870-13023 1,1-Dichloroethane<0.001000.05000.05441090.05000.0513103672-12520 1,2-Dichloroethane<0.001000.05000.05461090.05000.0511102768-12720 1,1-Dichloroethene<0.001000.05000.05441090.05000.0517103559-17222 cis-1,2-Dichloroethylene<0.001000.05000.05491100.05000.0508102875-12520 trans-1,2-dichloroethylene<0.001000.05000.05471090.05000.0512102775-12520 1,2-Dichloropropane <0.001000.05000.05371070.05000.0509102574-12520 1,3-Dichloropropane<0.001000.05000.05421080.05000.0508102675-12520 2,2-Dichloropropane<0.001000.05000.05381080.05000.0501100775-12520 1,1-Dichloropropene<0.001000.05000.05521100.05000.0519104675-12520 cis-1,3-Dichloropropene<0.001000.05000.05411080.05000.0508102674-12520 trans-1,3-dichloropropene<0.001000.05000.05481100.05000.0507101866-12520 Ethylbenzene<0.001000.05000.05431090.05000.0509102675-12520 Hexachlorobutadiene <0.001000.05000.05621120.05000.0559112175-12520 Isopropylbenzene<0.001000.05000.05441090.05000.0510102675-12520 Methylene Chloride<0.005000.05000.0436870.05000.0384771375-12535 Naphthalene<0.002000.05000.05871170.05000.0601120275-12520 n-Propylbenzene<0.001000.05000.05331070.05000.0511102475-12520 Styrene<0.001000.05000.05361070.05000.0501100775-12551 1,1,1,2-Tetrachloroethane<0.001000.05000.05441090.05000.0511102672-12520 1,1,2,2-Tetrachloroethane <0.001000.05000.05571110.05000.0515103874-12531 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 28 of 32 Final Form 3 - MS / MSD Recoveries Project Name:--- Work Order # :Project ID: 17792.1 433172 Lab Batch ID: 1Water 876994 QC- Sample ID:433173-001 SBatch #:Matrix: 12/13/2011 Date Prepared:Analyst:JBU 12/13/2011 Date Analyzed: Reporting Units:mg/L Parent Spiked SampleSpikedDuplicateSpikedControlControl VOAs by SW-846 8260B Sample SpikeResultSampleSpikeSpiked SampleDup.RPDLimitsLimitsFlag Result Added[C]%RAddedResult [F]%R% %R%RPD Analytes [A] [B][D][E][G] Tetrachloroethylene<0.001000.05000.05361070.05000.049699871-12520 Toluene <0.001000.05000.05361070.05000.0503101659-13921 1,2,3-Trichlorobenzene<0.001000.05000.05701140.05000.0564113175-13720 1,2,4-Trichlorobenzene<0.001000.05000.05691140.05000.0563113175-13520 1,1,1-Trichloroethane<0.001000.05000.05511100.05000.0521104675-12520 1,1,2-Trichloroethane<0.001000.05000.05421080.05000.0507101775-12720 Trichloroethylene<0.001000.05000.05481100.05000.0508102862-13724 Trichlorofluoromethane<0.001000.05000.05521100.05000.0523105567-12520 1,2,3-Trichloropropane <0.0008220.05000.05561110.05000.0514103875-12520 1,2,4-Trimethylbenzene<0.001000.05000.05241050.05000.0501100475-12520 1,3,5-Trimethylbenzene<0.001000.05000.05211040.05000.0503101470-12520 o-Xylene<0.001000.05000.05361070.05000.0502100775-12520 m,p-Xylenes<0.002000.1000.1081080.1000.0997100875-12520 Vinyl Chloride<0.0004000.05000.05301060.05000.049198875-12520 Matrix Spike Percent Recovery [D] = 100*(C-A)/B Matrix Spike Duplicate Percent Recovery [G] = 100*(F-A)/E Relative Percent Difference RPD = 200*|(C-F)/(C+F)| ND = Not Detected, J = Present Below Reporting Limit, B = Present in Blank, NR = Not Requested, I = Interference, NA = Not ApplicableN = See Narrative, EQL = Estimated Quantitation Limit Page 29 of 32 Final Sample Duplicate Recovery --- Project Name: Work Order #:433172 17792.1 Project ID: 877184 Lab Batch #: 12/15/2011 Date Prepared:Analyst:4150 12/15/2011 22:09 Date Analyzed: 1Water Batch #:Matrix: QC- Sample ID:433064-007 D SAMPLE / SAMPLE DUPLICATE RECOVERY mg/L Reporting Units: Metals, Total by SW846 6010C SampleControl Parent Sample DuplicateRPDLimits Result Flag Result%RPD [A] [B] Analyte Arsenic <0.00400<0.00400 020U Barium0.01050.0108 320J Cadmium<0.000300<0.000300 020U Chromium0.0009000.000700 2520FJ Lead<0.00330<0.00330 020U Selenium <0.0113<0.0113 020U Silver<0.0006000.000700NC20J Spike Relative Difference RPD 200 * | (B-A)/(B+A) | All Results are based on MDL and validated for QC purposes. BRL - Below Reporting Limit Page 30 of 32 Final Page 31 of 32 Final XENCO Laboratories Prelogin/Nonconformance Report- Sample Log-In Client:Reed Engineering Group, Inc. Acceptable Temperature Range: 0 - 6 degC Air and Metal samples Acceptable Range: Ambient Date/ Time Received:12/12/2011 04:25:00 PM Temperature Measuring device used : Work Order #:433172 Sample Receipt Checklist Comments #1 *Temperature of cooler(s)?4.4 Yes #2 *Shipping container in good condition? Yes #3 *Samples received on ice? #4 *Custody Seals intact on shipping container/ cooler?No No #5 Custody Seals intact on sample bottles/ container? No #6 *Custody Seals Signed and dated for Containers/coolers Yes #7 *Chain of Custody present? #8 Sample instructions complete on Chain of Custody?Yes No #9 Any missing/extra samples? Yes #10 Chain of Custody signed when relinquished/ received? Yes #11 Chain of Custody agrees with sample label(s)? #12 Container label(s) legible and intact?Yes Yes #13 Sample matrix/ properties agree with Chain of Custody? Yes #14 Samples in proper container/ bottle? Yes #15 Samples properly preserved? #16 Sample container(s) intact?Yes Yes #17 Sufficient sample amount for indicated test(s)? Yes #18 All samples received within hold time? Yes #19 Subcontract of sample(s)?Xenco Houston and Xenco ATL #20 VOC samples have zero headspace (less than 1/4 inch bubble)?Yes Yes #21 <2 for all samples preserved with HNO3,HCL, H2SO4? N/A #22 >10 for all samples preserved with NaAsO2+NaOH, ZnAc+NaOH? * Must be completed for after-hours delivery of samples prior to placing in the refrigerator Analyst: PH Device/Lot#: NonConformance: Corrective Action Taken: Nonconformance Documentation Contact:Contacted by :DateTime : Checklist completed by: Date:12/14/2011 Angelica Martinez Checklist reviewed by: Date:12/13/2011 Page 32 of 32 Final