Cambridge Phase 2-LR 970402EOTECH N ICAL E NGINEERING E INVIRONMENTAL GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant: Location of Placement: April 2, 1997 Date Concrete Placed: March 24, 1997 Beamer Development, Inc. Estates of Cambridge Manor, Phase II Gilco Contracting, Inc. TXI/#41 Paving Castle Creek Drive Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 04 Project Number: 96-0298 MATERIALS sou=, SSD Balch Wis. INSPECTION DATA Description (LbslCuYd) Mix Number: 8272A Arrive Job: 11:25 am Cement: 5 sk Time Sampled: 11:55 am Sample Location: Station 6 + 90; 8' North of South curb Fly Ash: Truck/Ticket No: 669/761076 Coarse Aggregate: Temperature: Intermediate Aggregate: Ambient Range: 80° Concrete Range: 78 ° Fine Aggregate: Slump Range (inches): 1 Admixtures: AEA Weather Conditions: Partly Cloudy I Time Started: 9:15 am Time Completed: 7:45 pm 2 Sample Air Content (%): 4% Added Water: 20 gallons Total Cubic Yards Placed: 70 Required Strength (Lbs./sq.in.): 3000 psi Spncimon Mnasured Age Date To~l ~ Compressive S~ron~h Remarks Number Slump (in.) (D~ys) Tested 0..bs.) (Lbs./Sq. ln.) ECM 12 7 03/31/97 105,060 3,720 Unit Weight 147.1 pcf ECM 13 7 03/31/97 111,760 3,950 Truck 456 also tested and found to ECM 14 11/2" 28 04/21/97 have i/~. inch slump and unit weight ECM 15 28 04/21/97 of 148.7 pcf Test Methods Utilized Fracture ~e~ul~ Cylinders Made By: MF ASTM C-31,C-39,C-143 (Unless Nmed Otherwise) Remarks and/or Distribution: cc: Mr. Jack Bommarito - Beamer Development, Inc. Mr. David Carlton - Dowdey Anderson Associates Mr. Larry Davis - City of Coppell Mr. Dale Gilreath - Gilco Contracting Inc. Reviewed by, All letters and reports are for the exclusive use of the client to whom they are addressed and shall no( be reproduced without the full approval of GEE Cmuultams, Inc. The use of our name must receive ou~ prior written approval. Our letters and relx~ts apply only to thc sample tested and/or inspected and are not necessarily indicative of the quanthies of apparently identical or similar prnduct~. ]EOTECHNICAL GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MiX INSPECTION Report Date: Cliem: Pwject: Contractor: Concrete Supplier and Plant: Location of Placement: April 2, 1997 Date Concrete Placed: March 24, 1997 Beamer Development, Inc. Estates of Cambridge Manor, Phase II Gilco Contracting, Inc. TXI/#41 Paving Castle Creek Drive Standard 6"x12' Area 28.27 Square Inches Concrete Report No.: 05 Pwject Number: 96-0298 MATERIALS 5ource! sso Ba,ch wts. INSPECTION DATA Description (Lbs/CuYd) Mix Number: 8272A Cement: 5 sk Fly Ash: Coarse Aggregate: Intermediate Aggregate: Fine Aggregate: Admixtures: AEA 1 2 Added Water: 20 gallons Arrive Job: Time Sampled: Sample Location: Tmck/Ticket No: Temperature: Ambient Range: 78° Concrete Range: 79° Slump Range (inches): 2 tA" Weather Conditions: Partly Cloudy Time Started: 9:15 am Time Completed: 7:45 pm Sample Air Contem (%): 2',6% Total Cubic Yards Placed: 130 12:08 pm 12:40 pm Station 5 + 50; 5' East of West curb 460/761154 Required Strength (Lbs./sq.in.): 3000 psi Specimen Measured Age Date To,al Lead Compressive Strength Remarks Number Slump (in.) (Day~) Tested (Lbs.) (Lb~./Sq. ln.) ECM 16 7 03/31/97 102,200 3,610 ECM 17 7 03/31/97 99,140 3,510 2~A,, ECM 18 28 04/21/97 ECM 19 28 04/21/97 Test Methods Utilized Fracture Regular Cylinders Made By: MF ASTM C-31.C-39,C-143 (Unless Noted Otherwise) Remarks and/or Distribution: Mr. Jack Bommarito - Beamer Development, Inc. Mr. David Carlton - Dowdey Anderson Associates Mr. Larry Davis - City of Coppell Mr. Dale Gilreath - Gilco Contracting ~tevie~ed All letters and reports are for the exclusive use of the cli;nt to whom they are addressed and shall nm be reproduced without the full approval of GEE CousullantL Inc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested nod/or iuspected and are ne~ necessarily indicative oftbe qnandties of apparently identical or similar products. EOTECHNICAL EJNGINEERING J E JNVlRONMENTAL GEE Consultants, inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant: Location of Placement: April 2, 1997 Date Concrete Placed: March 24, 1997 Beamer Development, Inc. Estates of Cambridge Manor, Phase II Gilco Contracting, Inc. TXI/#41 Paving Castle Creek Drive Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 06 Project Number: 96-0298 MATERIALS Son,~e/ sso Batch wts. INSPECTION DATA Description (Lb~/CuYd) Mix Number: 8272A Arrive Job: Cement: 5 sk Time Sampled: Sample Location: Fly Ash: Track/Ticket No: Coarse Aggregate: Temperature: Intermediate Aggregate: Ambient Range: 80° Concrete Range: 76° Fine Aggregate: Slump Range (inches): 2 ¼ ' Admixtures: AEA Weather Conditions: Partly Cloudy Time Started: 9:15 am I Time Completed: 7:45 pm 2 Sample Air Content (%): 2tA% Added Water: 20 gallons Total Cubic Yards Placed: 230 Required Strength (Lbs./sq.in.): 3000 psi 1:35 pm 2:10 pm Station 3 + 90; 4' East of West curb 456/761322 Specimen Measured Age Da~e Total Load Compressive Stren~& Remarks Number Slump (in.) (Days) Tested (Lbs.) (LIn./Sq.ln.) ECM 20 7 03/31/97 91,300 3,230 ECM 21 7 03/31/97 92,120 3,260 2'A" ECM 22 28 04/21/97 ECM 23 28 04/21/97 Test Methods Utilized Flacture Regular Cylinders Made By: MF ASTM C-31,C-39,C-143 (Unluss Nmed Otherwise) Remarks and/or Distribution: cc: Mr. Jack Bommarito - Beamer Development, Inc. Mr. David Carlton - Dowdey Anderson Associates Mr. Larry Davis - City of Coppell Mr. Dale Gilreath - Gilco Contracting All letters and reports are for the exclusive use of the clh~nt to whom they are addressed and shall not be reproduced without the full approval of GEE Cortsullants,'lnc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample t~sled and/or inspected and are not necessarily indicative of the quantities of apparently identical or similar products. EOTECHNICAL E NGINEERING EJ NVIRONMENTAL GEE Consultants, Inc. 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF CONCRETE MIX INSPECTION Report Date: Client: Project: Contractor: Concrete Supplier and Plant: Location of Placement: April 2, 1997 Date Concrete Placed: March 24, 1997 Beamer Development, Inc. Estates of Cambridge Manor, Phase II Gilco Contracting, Inc. TXI/#41 Paving Castle Creek Drive Standard 6"x12" Area 28.27 Square Inches Concrete Report No.: 07 Project Number: 96-0298 MATERIALS so~/ ssD..~h w.. INSPECTION DATA Description (Lbs/CuYd) Mix Number: 8272A Arrive Job: Cement: 5 sk Time Sampled: Sample Location: Fly Ash: Tmck/Ticket No: Coarse Aggregate: Temperature: Intermediate Aggregate: Ambient Range: 80° Concrete Range: 78° Fine Aggregate: Slump Range (inches): 1 Admixtures: AEA Weather Conditions: Partly Cloudy I Time Started: 9:15 am 2 Time Completed: 7:45 pm Sample Air Content (%): Added Water: 10 gallons Total Cubic Yards Placed: 360 Required Strength (Lbs./gl.in.): 3000 psi 3:35 pm 4:00 pm Station 1 + 60; 5' East of West cuFo 669/761508 Specimen Measured Age Dnte Total Load Compressive Strength Remnrk~ Number Slump (in.) (Days) Tested (Lbs.) (Un./Sq. ln.) ECM 24 7 03/31/97 95,080 3,360 ECM 25 1 l/l" 7 03/31/97 97,740 3,460 ECM 26 28 04/21/97 ECM 27 28 04/21/97 Test Methods Utilized Fracture Rejular ASTM C-31,C-39.C-143 (Unless Noted Otherwise) Cylinders Made By: MF Remarks and/or Distribution: cc: Mr. Jack Bommarito - Beamer Development, Inc. Mr. David Carlton - Dowdey Anderson Associates Mr. Larry Davis - City of Coppell Mr. Dale Gilreath - Gilco Contracting GJE ~it~t~, Zne. Reviewed by, All leaars and ~m are for the exclusive nsc oftbe client to whom they are addressed and shall not be reproduced without the full approval of GEE Comultents, Inc, The ase of our name mnst receive our prior written approval. Out letters and re.p~ts apply only to the sample tested and/ns inspected and are not necessarily indicative of the quantities of npparemly identical or similar products.