Cambridge Phase 2-LR 970211EOTECHNICAL
ENGINEERING
E[ NVIRONMENTAL
GEE Consultants, Inc.
10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972
REPORT OF CONCRETE MIX INSPECTION
Report Date:
Client:
Project:
Contractor:
Concrete Supplier and Plant:
Location of Placement:
February 11, 1997 Date Concrete Placed: January 31, 1997
Beamer Development, Inc.
Estates of Cambridge Manor, Phase 1I
O.K. Concrete
Pioneer/#27
Manhole
Standard 6'x12~
Area 28.27 Square Inches
Concrete Report No.: 02
Project Number: 96-0298
MATERIALS s ..... ! SSD Batch Wes. INSPECTION DATA
Dnscriplion (Lbs/CuYd)
Mix Number: 9339 Time Sample Batched
Cement: 5 sk Time Sampled:
Sample Location:
Fly Ash: Truck/Ticket No:
Coarse Aggregate: Temperature:
Intermediate Aggregate: Ambient Range: 79°
Concrete Range: 70°
Fine Aggregate: Slump Range (inches):
Admixtures: Weather Conditions: Clear
I Time Started: 1:45 pm
2 Time Completed: 5:15 pm
Sample Air Content (%): 2%
Added Water: 0 gallons Total Cubic Yards Placed: 8
Required Strength (Lbs./sq.in.): 3500 psi
3:10 pm
3:45 pm
Allen & Deforest; Sount end of site
582~320910
Specimen Measured Age Date To~al Load Comprnssive Strength Remarks
Number Slump (in.) (Days) Tested (Lbs.) (Lbs./Sq.ln.)
ECM 04 7 02/07/97 90,440 3,200
ECM 05 28 02/28/97
5"
ECM 06 28 02/28/97
EMC 07 H Hold
Test Methods Ulilieed Fracture Regular
ASTM C-31,C-39,C-143 (Unless Neaed Otherwise) Cylinders Made By: AJA
Remarks and/or Distribution:
CC:
Mr. Jack Bommarito - Beamer Development, Inc.
Mr. David Carlton- Dowdey Anderson Associates
Mr. Larry Davis - City of Coppell
Reviewed by: ~'~~
All letters and reports are for tile exclusive use of the client to whom they arc addressed and shall not be reproduced without the full q',proval of GEE Consultants, Inc. The me of our nam~ must receive
our prior wrltlen approval. Our letters and reporls apply only Io the sample lested aud/or impeclnd and are i~ol mcnssarily indicative of die quantities of appareully identical or similar products.
-~ EOTECHNICAL
E NGINEERING
Ej NVIRONMENTAL
GEE Consultants, Inc.
10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972
REPORT OF CONCRETE MIX INSPECTION
Report Date:
Client:
Project:
Contractor:
Concrete Supplier and Plant:
Location of Placement:
February 11, 1997 Date Concrete Placed: January 20, 1997
Beamer Development, Inc.
Estates of Cambridge Manor, Phase Il
O.K. Concrete
Unknown
Manhole
Standard 6"x12"
Area 28.27 Square Inches
Concrete Report No.: 01
Project Number: 96-0298
s .... / sso nat¢~ Wt~. INSPECTION DATA
MATERIALS
Mix Number: Time Sample Batehed unknown
Cement: 6 sk Time Sampled: unknown
Sample Location: unknown
Fly Ash: Truck/Ticket No: unknown
Coarse Aggregate: Temperature:
Intermediate Aggregate: Ambient Range: unknown
Concrete Range: unknown
Fine Aggregate: Slump Range (inches): unknown
Admixtures: Weather Conditions: unknown
I Time Started: unknown
2 Time Completed: unknown
Sample Air Content (%): unknown
Added Water: unknown Total Cubic Yards Placed: unknown
Required Strength (Lbs./sq.in.): unknown
Sjgcill~ll Measured Age Date Tmal Load Convpressive SlrCll~t[! R~marks
Numar Slump (in.) (Days) Tesled (L~.) (L~.~q.ln.)
ECM 01 10 01/30/97 81,440 2,880
ECM 02 28 02/17/97
N/A
ECM 03 28 02/17/97
T~sI Meth~s Otiliz~ Fracture ReguJar
ASTM C-31,C-39,C-143 (Unless Noted Olhe~wise) Cyli~ers Made By: Co~tFactoF
Remarks and/or Distribution:
cc:
Mr. Jack Bommarito - Beamer Development, Inc.
Mr. David Carlton - Dowdey Anderson Associates
Mr. Larry Davis - City of Coppell
~E Consultants, Inc.
All letters and reports are fro' the exclusive use of Ihe client to whom they are addressed n~d slmll not be reproduced wilhoUt the full approval of GEE Consultants. Inc. The use of our name must receive
our prior written approval. Our letters and reports apply tuffy to the snmple tested and/or inspected and are not necessarily indicative of the quantities of apparently identical o~ similar products.
EOTECH N I CAL
E NGINEERING
EJ NVIRONMENTAL
GEE Consultants, Inc.
10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972
REPORT OF CONCRETE MIX INSPECTION
Report Date:
Client:
Project:
Contractor:
Concrete Supplier and Plant:
Location of Placement:
February 11, 1997 Date Concrete Placed: Feburary 3, 1997
Beamer Development, Inc.
Estates of Cambridge Manor, Phase Il
O.K. Concrete
Pioneer///27
Inlet
Standard 6"x12"
Area 28.27 Square Inches
Concrete Report No.: 03
Project Number: 96-0298
MATERIALS s ..... z ssD.atch w,~. INSPECTION DATA
Description (Lbs/CuYd)
Mix Number: 9339 Arrive Job:
Cement: 5 sk Time Sampled:
Sample Location:
Fly Ash: Track/Ticket No:
Coarse Aggregate: Temperature:
Intermediate Aggregate: Ambient Range: 70°
Concrete Rauge: 74'
Fine Aggregate: Slump Range (inches): 4"
Admixtures: Weather Conditions: Overcast
1 Time Started: 1:30 pm
2 Time Completed: 4:00 pm
Sample Air Content (%): 4%
Added Water: 10 gallons Total Cubic Yards Placed:
Required Strength (Lbs./sq.in.): 3500 psi
unknown
3:15 pm
inlet, Southwest comer of site
547/321060
Specimen Measured Age Date Total L~ed Co~npressive Slreuglh Remarks
Number Slump (in.) (Days) Tesled (Lbs.) (Lbs./Sq.ln.)
ECM 08 7 02/10/97 112,200 3,970
ECM 09 7 02/10/97 111,300 3,940
4"
ECM 10 28 03/03/97
EMC 11 28 03/03/97
Test Methods Utilized Fracture Regular Cylinders Made By: DF
ASTM C-31,C-39,C-143 (Unless Noled Otherwise)
Remarks and/or Distribution:
cc:
Mr. Jack Bommarito - Beamer Development, Inc.
Mr. David Carlton - Dowdey Anderson Associates
Mr. Larry Davis - City of Coppell
Consultants, Inc.
Reviewed
^il lelters and reports are for file exclusive use of tim client lo whom they are addressed and shall uot be reproduced without the full approval of GEE Consultants, Inc. Tie use of our name must receive
our pri~ written approval. Our letters and reports apply only lo the sample tested and/or inspected and are nol necessarily indicative of Ihe quantilies of apparently identical or similar products.