St Ann Catholic-LR070524 CONCRETE COMPRESSIVE S- NGTH TEST lierracon Report Number: 94061334.0054 Service Date: March 28 2007 8901 Carpenter Frwy,Ste#100 Dallas,Texas 75247 (214)630-1010 Client: Report Date:May 24, 2007 St Ann Catho ' Church Project: St. Ann Catholic Parish 2 006 Ej''4NSi0A/ Attn: Jenni r Lindsey New Addition 180 Sa el Blvd 180 Samuel Blvd. Copj7/e#,/ e TX 75019 Coppell, TX Project No.: 94061334 Material Information Sample Information Specified Strength: 3000 psi @ 28 Days Date Cast: March 28, 2007 Time:8:40 AM Sampled by: Moe E. Odom Batch Time: 7:45 AM Plant: 7 Weather Conditions: Cloudy, breeze Supplier: Lattimore Materials Co. Accumulative Yards: 50/50 Truck No: 5016 Ticket No:7176934 Placement Method: Pump Mix I.D. No.: 3266 Sample Locations: 0-35' east of header Water Added Onsite Before Test: 5 Gallons Placement Location: Remaining north side 165' of east to west Water Added Onsite After Test: 0 Gallons flatwork/sidewalk (approximately 165' from yesterday's, 3/27/07, header to east end) Field Test Data Test Result Specification Test Method Slump, inches: 5.50 - ASTM C143 Air Content, %: 2.6 - ASTM C231 Concrete Temperature,OF: 76 - ASTM C1064 Ambient Temperature,°F: 69 ASTM C1064 Plastic Unit Weight, pcf: 144.0 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches)(sq. inches) Tested (days) (Ibs) (psi) 1 1 6.00 28.27 04/04/2007 7 96,090 3,400 1 2 6.00 28.27 04/25/2007 28 128,610 4,550 1 3 6.00 28.27 04/25/2007 28 132,880 4,700 Average (28 Days) 4,630 1 4 6.00 28.27 05/23/2007 56 148,590 5,250 Comments: Concrete mix was dyed at job site. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Moe E. Odom Report Distribution: / (1)St Ann Catholic Church (1)TechniStructures � (1)City of Coppell TX (1)Pacheco Koch Consulting Engineers Reviewed by: (1)City of Coppell TX A.Bulent Ethem,P.G. (1)Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is -xclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results tra smitted herein are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 O1-PDRB01-Future Key