Loading...
Royal Oaks-SP110225 • fiXi 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Letter Of Transmittal 2/25/2011 12:13:34PM Report: 120958 Contains the Following Reports: Report Description • Submittal#8099 for Project:Various-Fort Worth&Dallas • Detailed Data for Submittal#8099 • Backup Data for Mix:8204 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:8205 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:8206 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:8272 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:8273 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:8274 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:9053 of Submittal#8099 for Project:Various-Fort Worth&Dallas • Backup Data for Mix:9982 of Submittal#8099 for Project:Various-Fort Worth&Dallas • TXI Concrete Sand(January 2011).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • Cement Certificate(November 2010).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • Class F Fly Ash Limestone(December 2010).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • Bridgeport Stone (January 2011).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • Bridgeport Stone 1.5 -Belt Run(January 2011).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • MB-AE 90(January 2011).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • Polyheed 997(January 2011).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas • Pozzolith 200N(January 2011).pdf attachment for Submittal#8099 for Project:Various-Fort Worth&Dallas 1992-2011 Digital Site Systems,Inc. Pagel Quadrel'Service SM X1111 1 1341 West Mockingbird Lane • Dallas,Texas 75247 972.647.6700 www.txi.com February 25,2011 Conatser Construction, Inc. P.O. Box 15448 Fort Worth,TX. 76119 Attn: Mr. Bill Hurst RE: Various-Fort Worth& Dallas Mix Code Numbers 8204,8205,8206,8272,8273,8274,9053,9800,9982 The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are proposed for use on the above referenced project for ready-mixed concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project,please order by the mix design number which appears in the left hand corner of the mix design. TXI certifies that the above mix designs,when ordered by specified design identity, and delivered by TXI,will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78,C 172, C 293,applicable provisions of C 94, and evaluated in accordance with applicable provisions of the ACI building code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94 entitles a manufacturer to receive copies of all test reports when strength of concrete is used as a basis for acceptance. Contact us if you have any questions or require any additional information. Please notify TXI of approval of the proposed mix design prior to its use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix design is ordered,please send a copy of this letter, after approval,to the above referenced project to be used by the person ordering the concrete for this job. The information contained in this submittal is confidential and the exclusive property of TXI. It cannot be copied, duplicated or disclosed to third parties without the expressed written consent of TXI. Sincerely, TX!Operations, LP Victor H. Villarreal Manager-Q.A./Q.C. 1992-2011 Digital Site Systems,Inc. Page2 Quadrel'Service SM GENERAL NOTES Pumping Notes: 1. 5"minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Samples for slump and strength tests should be taken at discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout is recommended for lubrication. In the case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes,mix design modifications may be required to assure strength and pumpability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air content when loss occurs as a result of boom configuration or free fall discharge from hose. To ensure minimum air loss when pumping,maintain a continuous flow of concrete through the entire length of pipe and do not subject concrete to free fall. 7. The term "pumpable concrete"refers to concrete which is capable of being transported through an apparatus which forces concrete to the placing position through a pipeline or hose as long as the recommendations indicated above are followed. The term "pumpable concrete" does not relate to concrete proportioned in a particular manner or containing a specific type of product. Strength of lightweight mix designs valid provided strength specimens are air cured in accordance with ASTM Test Method C 567-05, section 7.3 except as modified in section 8.1, alternative method, ASTM Specification C 330-04. Unless otherwise indicated, when the concrete temperature at point of placement exceeds 90 degrees Fahrenheit, TXI will guarantee the strength performance of the mix design(s)herein submitted up to a maximum placement temperature of 100 degrees Fahrenheit using an ASTM C 494 Type D retarding water-reducer, as long as the concrete is placed within 75 minutes from batch time. Unless otherwise indicated,strength of plain concrete guaranteed up to a maximum placement temperature of 85 degrees Fahrenheit. We are enclosing all available back up data for the referenced mix design(s). If the strength information is not available, or is insufficient, confirmation tests may have to be conducted by your laboratory. 1992-2011 Digital Site Systems,Inc. Page3 Quadrel'Service SM TXI PROPRIETARY AND CONFIDENTIAL • fiX1 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction, Inc. Date Issued: February 25,2011 Project: Various- Fort Worth& Dallas Plant: 122 Lawnwood 8204 470#ADMIX/AEA I"CS Sidewalk Description Admix. SSD Weight (lb) Type 1/II Cement 376 Fly Ash "F" 94 1" -#4 Crushed Stone 1840 Concrete Sand 1326 City Water 258 MB-AE 90 0.3 to 4.0 oz/cwt CM PolyHeed 997 3.0 to 15.0 oz/cwt CM Specified F'c : 3,000 psi @ 28 days TOTAL 3894 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 144.2 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C+ P Ratio: 0.55 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per AC1 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page4 Quadrel iService SM tX1fb 1341 Mockingbird Lane,Dallas,Texas 75247 Date: 2/25/2011 '«J 'v^J (972)647-6700,www.txi.com Units: US Mix Name: 8204 Mix Strength: 3,000 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 5.13 4.29 4700 4700 28 620 3940 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 150 5.75 3.70 4430 4430 28 150 4.50 4.60 4310 4310 28 150 4.25 4.70 4770 4770 28 4500 150 4.75 4.20 4590 4590 28 4550 150 4.75 5.50 4850 4850 28 4740 150 7.00 4.30 3620 3620 28 4350 135 5.00 3.70 4980 4980 28 4480 150 6.25 4.20 4060 4060 28 4220 150 5.75 5.00 4090 4090 28 4370 150 5.00 4 .50 5050 5050 28 4400 143 5.00 3.70 5630 5630 28 4920 143 5.00 3.90 6090 6090 28 5590 143 4.75 4.00 4900 4900 28 5540 143 5.00 4.00 5120 5120 28 5370 143 4.75 3.70 5350 5350 28 5120 143 5.00 4.10 5540 5540 28 5340 143 5.00 4.60 4480 4480 28 5120 143 5.00 4.30 4390 4390 28 4800 143 5.00 3.90 4790 4790 28 4550 143 5.00 4.10 4420 4420 28 4530 143 4.75 4.20 5430 5430 28 4880 143 4.75 5.10 4980 4980 28 4940 143 4.25 3.90 4820 4820 28 5080 131 6.00 4.50 3720 3720 28 4510 142 6.00 5.00 3590 3590 28 4040 142 6.00 4.00 3860 3860 28 3720 142 6.00 4.50 4210 4210 28 3880 142 3.50 4.50 5250 5250 28 4440 121 4.75 3.90 5140 5140 28 4860 121 5.25 4470 4470 28 4950 1992-2011 Digital Site Systems,Inc. Pages Quadrel'Service SM TXI PROPRIETARY AND CONFIDENTIAL tA! 1341 Mockingbird Lane,Dallas Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction, Inc. Date Issued: February 25,2011 Project: Various- Fort Worth& Dallas Plant: 122 Lawnwood 8205 517#ADMIX/AEA 1"CS Structures, Paving Description Admix. SSD Weight (lb) Type I/II Cement 414 Fly Ash "F" _ 103 1"-#4 Crushed Stone 1840 Concrete Sand 1284 City Water 258 MB-AE 90 0.3 to 4.0 oz/cwt CM PolyHeed 997 3.0 to 15.0 oz/cwt CM Specified F'c : 3,000 psi @ 28 days TOTAL 3899 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 144.4 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C+ P Ratio: 0.50 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3,and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page6 Quadrel iService SM t • , Xi y` 1341 Mockingbird Lane,Dallas,Texas 75247 Date: 2/25/201 I 0 (972)647-6700,www.txi.com Units: US Mix Name: 8205 Mix Strength: 3,000 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 5.08 4.52 5300 5300 28 690 4110 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 128 6.00 3.80 5110 5110 28 120 3.00 5.90 5680 5680 28 120 3.00 6.00 6080 6080 28 5620 140 5.50 4.90 5050 5050 28 5600 122 6.50 4.00 5360 5360 28 5500 122 5.00 4030 4030 28 4810 122 4.00 4350 4350 28 4580 122 4.00 4410 4410 28 4260 122 5.75 4.80 4850 4850 28 4540 131 5.75 5.80 5730 5730 28 4990 131 5.00 4.00 6650 6650 28 5740 131 4.75 4.20 4970 4970 28 5780 150 5.75 4.50 4410 4410 28 5340 150 5.25 4.80 5330 5330 28 4900 150 5.00 4.20 4790 4790 28 4840 131 4.75 3.70 5510 5510 28 5210 150 5.75 4.40 5230 5230 28 5180 150 5.50 4.80 4720 4720 28 5150 131 4.50 4.20 6030 6030 28 5330 131 5.50 3.20 6310 6310 28 5680 150 5.75 4.30 6020 6020 28 6120 131 5.50 4.20 5820 5820 28 6050 131 5.00 3.60 6300 6300 28 6040 131 5.50 4.75 5550 5550 28 5890 140 4.50 6.00 4860 4860 28 5570 131 6.00 4.50 5230 5230 28 5210 131 6.00 4.50 5570 5570 28 5220 131 4.50 5.00 6130 6130 28 5640 131 4.50 3.20 4110 4110 28 5270 138 5.00 4.80 4940 4940 28 5060 1992-2011 Digital Site Systems,Inc. Pagel Quadrel iService SM TXI PROPRIETARY AND CONFIDENTIAL tX/ 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www txi.com Customer: Conatser Construction, Inc. Date Issued: February 25, 2011 Project: Various-Fort Worth& Dallas Plant: 122 Lawnwood 8206 564#ADMIX/AEA 1"CS Hand Placed Paving-City of Fort Worth Description Admix. SSD Weight (lb) Type I/II Cement 451 Fly Ash "F" 113 1"-#4 Crushed Stone 1840 Concrete Sand 1254 City Water 254 MB-AE 90 0.3 to 4.0 oz/cwt CM PolyHeed 997 3.0 to 15.0 oz/cwt CM Specified F'c : 4,000 psi @ 28 days TOTAL 3912 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 144.9 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C+ P Ratio: 0.45 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the above designed mix parameters of compressive strength,water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page8 Quadrel!Service SM • • Date: 2/25/2011 ,...._. itXit ).. 1341 Mockingbird Lane,Dallas,Texas 75247 ie+ (972)647-6700,www.txi.com J Units: US Mix Name: 8206 Mix Strength: 4,000 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 4.97 4.20 5210 5210 28 440 4590 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 120 5.50 5.90 5460 5460 28 120 4.50 4.70 5200 5200 28 120 5.75 6.20 4540 4540 28 5070 120 5.25 2.50 5120 5120 28 4950 146 5.00 4.60 5370 5370 28 5010 146 4.75 3.50 5340 5340 28 5280 146 5.25 5.30 4480 4480 28 5060 146 5.00 3.80 5410 5410 28 5070 146 5.25 4.50 4930 4930 28 4940 146 5.50 4.70 4900 4900 28 5080 120 4.75 4.00 5470 5470 28 5100 120 4.00 4.40 5440 5440 28 5270 120 5.00 3.80 5640 5640 28 5520 131 3.50 3.80 5550 5550 28 5540 146 5.50 3.00 5000 5000 28 5400 146 6.00 2.20 5030 5030 28 5190 146 5.75 2.50 4700 4700 28 4910 146 5.25 3.60 5620 5620 28 5110 146 5.75 3.30 5320 5320 28 5210 120 4.00 3.10 4890 4890 28 5270 120 3.25 3.20 5460 5460 28 5220 120 4.00 3.30 5270 5270 28 5210 120 4.25 4.00 4330 4330 28 5020 120 4.50 4.20 4550 4550 28 4710 131 7.00 4.40 4670 4670 28 4520 121 6.25 5.40 5460 5460 28 4890 121 5.00 7.20 5770 5770 28 5300 121 4.50 4.50 6030 6030 28 5750 121 5.25 5.70 5320 5320 28 5700 121 4.00 4.70 6030 6030 28 5790 1992-2011 Digital Site Systems,Inc. Page9 Quadrel iService SM TXI PROPRIETARY AND CONFIDENTIAL • tAllri 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction, Inc. Date Issued: February 25, 2011 Project: Various-Fort Worth& Dallas Plant: 122 Lawnwood 8272 5.00SK ADMIX/AEA 1"CS Sidewalk Description Admix. SSD Weight (lb) Type I/II Cement 470 1"-#4 Crushed Stone 1840 Concrete Sand 1352 City Water 258 MB-AE 90 0.3 to 4.0 oz/cwt CM Pozzolith 200N 3.0 to 4.0 oz/cwt CM Specified F'c : 3,000 psi @ 28 days TOTAL 3920 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 145.2 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C + P Ratio: 0.55 Designed Air: 4.5 % Designed Volume: 27.00 cuff NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the above designed mix parameters of compressive strength,water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page 10 Quadrel iSery ice SM t • Date: 2/25/2011 1341 Mockingbird Lane,Dallas,Texas 75247 4Kr 0^�.....%� (972)647-6700,www.txi.com Units: US Mix Name: 8272 Mix Strength: 3,000 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 4.97 4.20 5210 5210 28 440 3590 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 120 5.50 5.90 5460 5460 28 120 4.50 4.70 5200 5200 28 120 5.75 6.20 4540 4540 28 5070 120 5.25 2.50 5120 5120 28 4950 146 5.00 4.60 5370 5370 28 5010 146 4.75 3.50 5340 5340 28 5280 146 5.25 5.30 4480 4480 28 5060 146 5.00 3.80 5410 5410 28 5070 146 5.25 4.50 4930 4930 28 4940 146 5.50 4.70 4900 4900 28 5080 120 4.75 4.00 5470 5470 28 5100 120 4.00 4.40 5440 5440 28 5270 120 5.00 3.80 5640 5640 28 5520 131 3.50 3.80 5550 5550 28 5540 146 5.50 3.00 5000 5000 28 5400 146 6.00 2.20 5030 5030 28 5190 146 5.75 2.50 4700 4700 28 4910 146 5.25 3.60 5620 5620 28 5110 146 5.75 3.30 5320 5320 28 5210 120 4.00 3.10 4890 4890 28 5270 120 3.25 3.20 5460 5460 28 5220 120 4.00 3.30 5270 5270 28 5210 120 4.25 4.00 4330 4330 28 5020 120 4.50 4.20 4550 4550 28 4710 131 7.00 4.40 4670 4670 28 4520 121 6.25 5.40 5460 5460 28 4890 121 5.00 7.20 5770 5770 28 5300 121 4.50 4.50 6030 6030 28 5750 121 5.25 5.70 5320 5320 28 5700 121 4.00 4.70 6030 6030 28 5790 1992-2011 Digital Site Systems,Inc. Page 1 1 Quadrel iService SM TXI PROPRIETARY AND CONFIDENTIAL 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction,Inc. Date Issued: February 25,2011 Project: Various-Fort Worth& Dallas Plant: 122 Lawnwood 8273 5.50SK ADMIX/AEA 1"CS Structures, Paving Description Admix. SSD Weight (lb) Type I/lI Cement 517 1"-#4 Crushed Stone 1 840 Concrete Sand 1312 City Water 258 MB-AE 90 0.3 to 4.0 oz/cwt CM Pozzolith 200N 3.0 to 4.0 oz/cwt CM Specified F'c : 3,500 psi @ 28 days TOTAL 3927 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 145.5 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C+ P Ratio: 0.50 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the above designed mix parameters of compressive strength,water cement ratio, cement content,and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3,and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI.Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page 12 Quadrel iSery ice SM /IX/ . i 1341 Mockingbird Lane,Dallas,Texas 75247 Date: 2/25/2011 AIN /',,W (972)647-6700,www.txi.com ^+ Units: US Mix Name: 8273 Mix Strength: 3,500 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 5.10 4.08 5260 5260 28 710 4650 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 121 3.00 4.10 6220 6220 28 144 6.25 5940 5940 28 144 6.00 5700 5700 28 5950 144 5.00 3.90 5940 5940 28 5860 144 5.00 3.30 6110 6110 28 5920 144 5.25 3.30 5370 5370 28 5810 144 5.50 3.60 5660 5660 28 5710 121 4.50 3.50 5040 5040 28 5360 121 3.00 3.40 5180 5180 28 5290 131 3.25 3.50 5700 5700 28 5300 131 4.00 4.00 5720 5720 28 5530 121 3.25 3.40 5290 5290 28 5570 140 5.00 4.40 5610 5610 28 5540 121 3.00 3.60 6460 6460 28 5780 131 7.50 5890 5890 28 5990 131 4.00 5350 5350 28 5900 143 3.75 3.70 5480 5480 28 5570 150 5.25 4.00 4590 4590 28 5140 150 6.25 4.60 4160 4160 28 4740 150 6.75 4.50 4350 4350 28 4360 150 7.25 4.20 4330 4330 28 4280 150 6.00 4.40 4410 4410 28 4360 150 7.75 5.50 5110 5110 28 4610 150 5.50 3.90 4680 4680 28 4730 150 5.75 4.20 4390 4390 28 4720 150 6.00 4.00 4520 4520 28 4530 150 5.50 4.60 4590 4590 28 4500 150 4.75 4.60 4770 4770 28 4630 150 6.00 4.80 4500 4500 28 4620 121 3.00 5.00 6670 6670 28 5310 1992-2011 Digital Site Systems,Inc. Page13 Quadrel iService SM TXI PROPRIETARY AND CONFIDENTIAL ix! 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction, Inc. Date Issued: February 25,2011 Project: Various-Fort Worth& Dallas Plant: 122 Lawnwood 8274 6.00SK ADMIX/AEA I"CS Structures, Paving Description Admix. SSD Weight (lb) Type I/II Cement 564 1" -#4 Crushed Stone 1840 Concrete Sand 1273 City Water 258 MB-AE 90 0.3 to 4.0 ozJcwt CM Pozzolith 200N 3.0 to 4.0 oz/cwt CM Specified F'c : 4,000 psi @ 28 days TOTAL 3935 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 145,7 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C + P Ratio: 0.46 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength,water cement ratio, cement content, and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-3I. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page l4 Quadrel'Service SM • Date: 2/25/2011 _ tX/ 1341 Mockingbird Lane,Dallas,Texas 75247 IN (972)647-6700,www.txi.com '�:1 Units: US Mix Name: 8274 Mix Strength: 4,000 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 3.91 3.51 5750 5750 28 440 4590 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 121 2.50 3.00 6320 6320 28 121 3.00 3.10 5940 5940 28 131 2.50 3.00 5400 5400 28 5880 121 3.25 3.40 6050 6050 28 5790 131 4.50 4830 4830 28 5420 121 3.50 4.70 6400 6400 28 5760 121 3.00 3.10 5710 5710 28 5650 131 3.00 2.00 5160 5160 28 5760 131 3.00 6250 6250 28 5710 121 2.00 3.00 5710 5710 28 5710 121 3.00 3.10 5530 5530 28 5830 121 3.00 3.40 5870 5870 28 5700 121 4.50 3.40 5620 5620 28 5670 121 3.00 4.10 6220 6220 28 5900 144 6.00 5700 5700 28 5850 144 6.25 5940 5940 28 5950 144 5.00 3.90 5940 5940 28 5860 144 5.00 3.30 6110 6110 28 6000 144 5.25 3.30 5370 5370 28 5810 144 5.50 3.60 5660 5660 28 5710 121 4.50 3.50 5040 5040 28 5360 121 3.00 3.40 5180 5180 28 5290 131 3.25 3.50 5700 5700 28 5300 131 4.00 4.00 5720 5720 28 5530 121 3.25 3.40 5290 5290 28 5570 140 5.00 4.40 5610 5610 28 5540 121 3.00 3.60 6460 6460 28 5780 131 4.00 5350 5350 28 5800 131 7.50 5890 5890 28 5900 121 3.00 5.00 6670 6670 28 5970 1992-2011 Digital Site Systems,Inc. Page15 Quadrel'Service SM TXI PROPRIETARY AND CONFIDENTIAL • t "i 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction, Inc. Date Issued: February 25,2011 Project: Various-Fort Worth& Dallas Plant: 122 Lawnwood 9053 7.00SK ADMIX/AEA 1"CS High Early Strength As Required Description Admix. SSD Weight (lb) Type I/lI Cement 658 1" -#4 Crushed Stone 1840 Concrete Sand 1194 City Water 258 MB-AE 90 0.3 to 4.0 oz/cwt CM Pozzolith 200N 3.0 to 4.0 oz/cwt CM Specified F'c : 5,000 psi @ 28 days TOTAL 3950 Specified Slump: 3.00 To 5.00 in. Designed Unit Weight: 146,3 lbs./cu.ft. Specified Air: 3.00 To 6.00 % Designed W/C + P Ratio: 0.39 Designed Air: 4.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer,and or contractor to insure that the above designed mix parameters of compressive strength,water cement ratio, cement content,and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: * HIGH-EARLY STRENGTH NOTES: I)Obtain ALL strength specimens at the point of placement. 2)Test specimens used for in-place early strength determination should be cured in a manner as close as possible to the in-place concrete. Utilization of insulated blankets or an insulated curing box is highly recommended. Hydration of portland cement is a temperture sensitive chemical reaction. In-place concrete generally develops and maintains substantially more heat than 6"x12"test cylinders. The difference in magnitude between in-place strength and the measured strength of 6"x12"cylinders increase as ambient temperatures decrease. Standard test cylinders used for 7 and 28 day evaluation should still be cured in strict accordance with ASTM C 31. 1992-2011 Digital Site Systems,Inc. Pagel6 Quadrel'Service SM „. X/• Date: 2/25/2011 1341 Mockingbird Lane,Dallas,Texas 75247 let (972)647-6700,www.txi.com �J Units: US Mix Name: 9053 Mix Strength: 5,000 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 24 4.89 4.56 5840 5840 28 440 5610 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 147 5.25 6000 6000 28 144 3.00 4.40 5760 5760 28 143 3.00 5.90 5650 5650 28 5800 144 3.00 3.80 6870 6870 28 6090 144 4.50 4.50 5700 5700 28 6070 144 6.00 5.00 5730 5730 28 6100 144 4.00 4.50 6340 6340 28 5920 144 3.00 3.40 6290 6290 28 6120 140 3.00 3.90 6530 6530 28 6390 122 5.25 5.80 5420 5420 28 6080 131 6.50 4.60 5290 5290 28 5750 131 5.00 4.80 6090 6090 28 5600 131 6.00 4.40 6160 6160 28 5840 131 5.50 4.90 5460 5460 28 5900 131 4.50 5.20 5120 5120 28 5580 150 4.00 5.00 6060 6060 28 5550 131 6.00 4.60 5710 5710 28 5630 131 5.50 4.40 6130 6130 28 5970 131 5.50 4.20 6040 6040 28 5960 131 6.50 3.80 5230 5230 28 5800 131 6.00 4.00 5170 5170 28 5480 131 5.00 4.80 5360 5360 28 5250 131 6.00 5.10 5520 5520 28 5350 140 5.25 3.90 6670 6670 28 5850 1992-2011 Digital Site Systems,Inc. Pagel 7 Quadrel'Service SM TXI PROPRIETARY AND CONFIDENTIAL tX'i 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.rxi.com Customer: Conatser Construction, Inc. Date Issued: February 25,2011 Project: Various-Fort Worth& Dallas Plant: 122 Lawnwood 9800 100/300 FLOWABLE FILL Flowable Fill Description Admix. SSD Weight (lb) Type UII Cement 100 Fly Ash "F" 300 Concrete Sand 2810 City Water 458 Specified Pc: TOTAL 3668 Specified Slump: 4.00 To 8.00 in. Designed Unit Weight: 135.9 lbs./cu.ft. Specified Air: 0.00 To 3.00 % Designed W/C+P Ratio: 1.15 Designed Air: 0.5 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio,cement content,and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3,and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Pagel 8 Quadrel'Service SM TXI PROPRIETARY AND CONFIDENTIAL • tX/ 1341 Mockingbird Lane,Dallas,Texas 75247 (972)647-6700,www.txi.com Customer: Conatser Construction, Inc. Date Issued: February 25,2011 Project: Various-Fort Worth & Dallas Plant: 122 Lawnwood 9982 6.00SK ADMIX/AEA 1.5"CS (CLASS "P") TxDot Hand Placed Paving Description Admix, SSD Weight (lb) Type I/II Cement 451 Fly Ash "F" 99 1"-#4 Crushed Stone 1240 1 1/2 "-3/4"Crushed Stone 826 Concrete Sand 1001 City Water 245 MB-AE 90 0.3 to 4.0 oz/cwt CM Pozzolith 200N 3.0 to 4.0 oz/cwt CM Specified F'c : 3,600 psi @ 28 days TOTAL 3862 Specified Slump: 1.00 To 3.00 in. Designed Unit Weight: 143.0 lbs./cu.ft. Specified Air: 4.50 To 7.50 % Designed W/C+ P Ratio: 0.45 Designed Air: 6.0 % Designed Volume: 27.00 cu.ft. NOTES: TXI has no knowledge or authority regarding where this mix is to be placed(if other than the defined use on page 1),therefore it is the responsibility of the project architect/engineer, and or contractor to insure that the above designed mix parameters of compressive strength, water cement ratio, cement content,and air content, are appropriate for the anticipated environmental conditions(ie. ACI-318 sections 4.1-4.3, and the local Building Codes). Data enclosed represents the potential of this mix when sampled and cured per ACI 301 and Section 1.6.3., and per ASTM C-31. Chemical admixtures are added in accordance with the manufacturer's recommendations. TXI reserves the right to adjust these dosages to meet the changes in jobsite demands. This mix has been designed to meet the requirements of the documents received from the project, and/or your verbal request. Aggregate weights may change depending on gradations or specific gravity of material. Mix Design Proportions and specifications are confidential and proprietary trade secrets of TXI. Any use or dissemination without permission is a violation of federal criminal law. COMMENTS: 1992-2011 Digital Site Systems,Inc. Page l9 Quadrel'Service SM X• Date: 2/25/20 1341 Mockingbird Lane,Dallas,Texas 75247 11 (972)647-6700,www.txi.com Units: US Mix Name: 9982 Mix Strength: 3,600 PSI at 28 Days STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 28 Avg Acc Accept Std ACI318 Tests Slump Air Day Age Age Dev Req'd 30 4.42 4.26 5200 5200 28 680 4680 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Plant Slump Air Strengths Acc Acc Age 28 Day Acc Age Age Run Avg 3 120 5.25 5.80 4630 4630 28 120 5.50 5.50 4790 4790 28 120 7.00 6.50 4480 4480 28 4630 120 4.50 3.90 5040 5040 28 4770 146 2.50 5980 5980 28 5160 146 1.00 6520 6520 28 5850 120 5.25 3.40 4340 4340 28 5610 120 4.50 3.40 5040 5040 28 5300 120 5.00 5.90 5470 5470 28 4950 120 4.50 6.50 4830 4830 28 5110 120 3.00 2.90 4910 4910 28 5070 120 3.75 4.20 5230 5230 28 4990 120 6.00 4.00 5350 5350 28 5160 120 4.50 3.50 5930 5930 28 5500 120 6.00 4.70 5740 5740 28 5670 120 5.50 4.20 4070 4070 28 5250 120 5.25 4.40 4660 4660 28 4820 120 4.75 3.50 4900 4900 28 4540 120 4.25 4.50 5190 5190 28 4910 120 4.50 4.70 4890 4890 28 4990 138 1.50 3.80 5930 5930 28 5330 146 0.50 3.20 6960 6960 28 5930 120 2.00 2.40 5540 5540 28 6140 120 7.50 3.60 4560 4560 28 5690 120 4.50 4.20 5290 5290 28 5130 120 4.50 4.00 5060 5060 28 4970 120 6.00 3.30 5820 5820 28 5390 120 5.00 3.70 5720 5720 28 5530 122 4.50 5.00 4040 4040 28 5190 122 4.00 4.50 5000 5000 28 4920 1992-2011 Digital Site Systems,Inc. Page2O Quadrel'Service SM (1112) TXI corp. TECHNICAL SERVICES LAB TXI Concrete Sand PHONE: 972-647-7232 FAX: 972-647-7244 WOWS, ANIONNIMINWOOMOSEMOW's a grAllICROACUMISeri,ANM'r,3}@a7I(d M3"Fw"Oi1RAL, ."?I itiD18"c an 0:15WM VIIMMINrd97H: 1a4?fiIAMI DLIVIS: DATE January 4, 2011 COMPANY/NAME MATERIAL Concrete Sand R' . kUMWE4"MINM4h MSSII IS M anti n G 41ERt 4!f'UOIR' snIPINIMORR1rL3 :etnin e ggrafrig nigoalitjexiRlN +. i IPS TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U.S. METRIC 3/8" 9.5mm 0 100.0% 100 #4 4.75mm 20.4 97.7% 95 100 #8 2.36mm 98.1 89.0% 80 100 #16 1.16mm 209.8 76.4% 50 85 #30 .600mm 372.7 58.1% 25 60 #50 .300mm 738.8 16.9% 10 35 #100 .150mm 846 4.9% 0 10 #200 .075mm 887.6 0.2% 0 3 TOTAL WEIGHT 889.2 MININSIONSMINNWISINt IIIIMMIMMIMAINISHOMMISMOVNIMMNSIMMIMICINIMMISMINNIIIIMMICIAMMUMMIAMORMIIMMON SPECIFIC TEST RESULTS TxDot 403-A Specific Gravity(SSD) 2.63 TxDot 411-A Magnesium Soundness 6 Sodium Soundness 2 TxDot 403-A Absorption 0.6 Unit Weight: TxDot 612-J Add Insoluble Residue 83 Dry Loose 104.2 LB./CF. Dry Rodded 110.5 LB./CF. TxDot 203-F Sand Equivalent 94 1 kri tilantr 'mitua uRmtlPISM%arum fl k'SMirer RJR"aYatrr#simormima ,Wk 1n'R9Y K mnrat 4'ti Iemeha.RIRE k,ava1mpE#4'Y`1orara"k+Iw,R m S,AkR. or aP'"t9im Skeet Caruthers TXI REPRESENTATIVE bdMIDLOTHIAN CEMENT 245 Ward Road• Midlothian,TX 76065• 972.775.3449 •www.txi.com m SPECIFICATIONS Portland Cement Bin Number: Car Number: Tons: Type I/II(Low Alkali) Sample Date: November-2010 Monthly Average A.S.T.M C150-09 Spec. Test Spec. Test Chemical Requirements: Limit Result Physical Requirements: Limit Result Si02, (%) A 20.0 Air Content, Volume, (%) 12 max 8 A1203, (%) 6.0 max 4.4 Average Fineness(Blaine), (m2/kg) 280 min 360 Fe203, (%) 6.0 max 3.6 420 max CaO, (%) A 64.7 MgO, (%) 6.0 max 1.3 Autoclave Expansion, (%) 0.80 max -0.04 S03, (%) 3.0 max 2.7 Loss on Ignition, (%) 3.0 max 2.2 Time of Setting: Insoluble Residue, (%) 0.75 max 0.37 Vicat initial set, minutes 45 min 129 002, (%) A 1.3 375 max 129 Limestone, (%) 5.0 max 3.0 CaCO3 in limestone, (%) 70 min 98 Compressive strengths,(Mpa) 3 days . ,'12.0 min 26.4 7 days 19.0 min 32.3 Potential phase composition, (%):B Compressive strengths,(psi) C3S A 63 3 days 1740 min 3835 C2S A 10 7 days 2760 min 4685 C3A 8 Max 6 C4AF A 11 C3S + 4.75(C3A) 100 max 89 q Spec. Test O p tional Chemical Requirements: Limit Result *S'-'''sr,...„„y Total Alkalies(Na20 equiv.), (%) 0.60 max 0.52 A Not Applicable. B Adjusted for limestone per A1.6 Certified to NSF/ANSI 61 We Certify that the above described cement, at the time of shipment meets the chemical and physical requirements of ASTM C-150 specification. Signature: Date: 12/14/10 Title: Quality Services Manager HEADWATER Addin g Value to Ener ,M gY Headwaters Resources certifies that pursuant to ASTM C-618-08 protocol for testing,the test data listed herein was generated by applicable ASTM methods and meets requirements of ASTM C-618 and AASHTO M-295 and TX.DOT DMS-4610 for Class F fly ash. Report of Class"F"Fly Ash Limestone Plant,Jewett, Texas Unit#1,2 DATE: December 13,2010 LABORATORY NUMBER: LEGS#1,2-10/26/10 MTRF#2663 LS COMPOSITE DATE 10/25/10— 10/26/10 ASTM C-618-08 TX. DOT DMS-4610 SPECIFICATIONS SPECIFICATIONS CHEMICAL ANALYSIS CLASS C CLASS F CLASS C CLASS F Silicon Dioxide (Si02) 52.24% Aluminum Oxide (A1203) 18.47% Iron Oxide (Fe2O3) 5.24% Sum of SiO2i A1203, & Fe203 75.95 % 50 Min. 70 Min. 50 Min 70 Min. Magnesium Oxide (MgO) 3.42% Sulfur Trioxide (SO3) 0.56% 5.0 Max. 5.0 Max. 5.0 Max. 5.0 Max. Moisture Content 0.04% 3.0 Max. 3.0 Max. 2.0 Max. 2.0 Max. Loss On Ignition 0.08% 6.0 Max. 6.0 Max. 3.0 Max. 3.0 Max. Available Alkalis as Na20 0.67% Calcium Oxide (CaO) 14.67% PHYSICAL ANALYSIS Fineness: Amount retained on 325 sieve % 15.90% 34% Max. 34%Max. 34% Max. 34% Max. Water Requirement, % Control 94% 105%Max 105%Max 105%Max 105%Max Specific Gravity 2.44 Autoclave Expansion, % -0.03 % 0.8%Max 0.8% Max 0.8%Max 0.8%Max Strength Activity Index With Portland Cement, 7 Day 90% 75%Min. 75% Min. 75% Min. 75% Min. 28 Day 99% 75%Min. 75% Min. 75% Min. 75% Min. AUTHORIZED SIG NATURE: P.O. Box 38 Thompsons,Texas 77481-0038 P:281.343.0079 F:281.343.0872 11411 TXI corp. Bridgeport Stone Plant Technical Services Lab P.O. Box 487 Phone: 972-647-7232 Bridgeport, Texas 76426 Fax: 972-647-7244 MUNISBMINAPIEMORMIK',MOM Y',+WIfiCIMPODINIVININIIIMICAMEINglantaMittaINGUMENKRAMMIVIMMONERWIENOMIAti DATE January 4, 2011 COMPANY/NAME MATERIAL 1" - #4 Class A torimosstaimmamantratirmintwitranotiotatimannemselsomgrimemeontlimmrammiorwlikadmrstemputentem TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U.S. METRIC 1 1/2" 37.5mm 0 100.0% 100 1" 25.0mm 0.5 98.5% 95 100 3/4" 19.0mm 7 79.0% 1/2" 12.5mm 19.2 42.3% 25 60 3/8" 9.5mm 25.2 24.3% #4 4.75mm 31.3 6.0% 0 10 #8 2.36mm 33 0.9% 0 5 TOTAL WEIGHT 33.3 mutostunommensminwilimmitimmtemituarraorMEICOMMOMMINOVIVIMISMINMICWW0111111901111111VMOMPUSIMMIRMIMIC, SPECIFIC TEST RESULTS Tx Dot 403-A Specific Gravity(SSD) 2.65 Tx Dot 411-A Magnesium Soundness 7 Sodium Soundness 3 Tx Dot 403-A Absorption 1.1 Unit Weight: Tx Dot 410-A LA Abrasion 30 Dry Loose 94.3 LB./CF. Dry Rodded 101.5 LB./CF TxDot 413-A Clay Lumps 0 TxDot 406-A Decantation 0.5 imaintaasitamirMISININgilrirmisingaffirstimiwolisiksaMSEIMINaturnmaurmimitimerltaManarmommostatmumionigium Skeet Caruthers Txi Representative aZill TX! corp. Bridgeport Stone Plant Technical Services Lab P.O. Box 487 Phone: 972-647-7232 Bridgeport, Texas 76426 Fax: 972-647-7244 01 $s WPM a.'' 112613111M. °, wow Ali •,olletiVAN G ,a i@MUISMILTAIMMENNESUM DATE January 4, 2011 COMPANY/NAME MATERIAL 1 1/2" Belt Run (ASTM C33, No. 4) uttl" "+. 9ummirti Pattek o mI l e r i3 k [ !'stun �a.tru C"'.}"I'"o"£ 1.tAa,'6q;!,tark 1?p c;" d ara ^rMdl 3r"r='.9t;.°s"i stuff 'm TEST RESULTS SIEVE SIZE WT. RETAINED % PASSING SPECIFICATION U.S. METRIC 2" 50.0mm 0 100.0% 100 1 1/2" 37.5mm 0.4 98.5% 95 100 11/4" 31.5mm 7.3 72.8% 1" 25.0mm 17.1 36.3% 25 55 7/8" 22.4mm 22.35 16.8% 3/4" 19.0mm 25.2 6.1% 0 10 5/8" 16.0mm 26.2 2.4% 1/2" 12.5mm 26.5 1.3% 3/8" 9.5mm 26.65 0.7% 0 5 TOTAL WEIGHT 26.85 IMININIMEMPIONSISIINIMEINUMINN' KI el ,u w + ha r tIVIMIIESOUVRO ° UMPIC iMINS MIMININ MOIIII M SPECIFIC TEST RESULTS TxDot 403-A Specific Gravity(SSD) 2.65 TxDot 411-A Magnesium Soundness 7 Sodium Soundness 3 TxDot 403-A Absorption 1.1 Unit Weight: TxDot 410-A L A Abrasion 30 Dry Loose 92.2 LB./CF. Dry Rodded 98.2 LB./CF. TxDot 413-A Clay Lumps 0 TxDot 406-A Decantation 0.6 wantistounamarasansminumaratammunimint, 3 atas1Kfommonumnst emosam @i&;anie G l,!wmPareg atG Tana u r Skeet Caruthers Txi Representative 5 BASF The Chemical Company January 5, 2011 TXI Operations, LP 1341 W. Mockingbird Lane Dallas, Texas 75247 Attention: Victor Villarreal Project: All Projects Project location: Various Certificate of Conformance MB-AE TM 90 BASF Construction Chemicals, LLC*Air-Entraining Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC ,which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc.,formerly known as Master Builders, Inc.) I, Richard Hubbard, Sr. Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify: That MB-AE 90 is a BASF Corporation Air-Entraining Admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of MB-AE 90; and That MB-AE 90, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.000068 percent(0.68 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds)of cement; and That MB-AE 90 meets the requirements of ASTM C 260, Corps of Engineers'CRD-C 13 and AASHTO M154, the Standard Specifications for Air-Entraining Admixtures for Concrete. J(4;364 Richard Hubbard Sr.Technical Marketing Specialist, BASF Corporation BASF Corporation ioulvard 23700 Chagrin Boulvard 216 Cleveland,39-7 00 OH 44122 []udders 216 839-7500 ph j,,,� www.masterbuilders.com Admixture Solutions gl BASF The Chemical Company January 5, 2011 TXI Operations, LP 1341 W. Mockingbird Lane Dallas, Texas 75247 Attention: Victor Villarreal Project: All Projects Project location: Various Certificate of Conformance PolyHeed®997 BASF Corporation*Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC ,which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc., formerly known as Master Builders, Inc.) I, Richard Hubbard, Sr.Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify: That PolyHeed 997 is a BASF Corporation Mid-Range Water-Reducing Admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of PolyHeed 997; and That PolyHeed 997, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00012 percent(1.2 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That PolyHeed 997 meets the requirements for a Type A, Water-Reducing Admixture, and Type F, Water-Reducing, High Range Admixture specified in ASTM C 494, Corps of Engineers'CRD-C 87 and AASHTO M194, the Standard Specifications for Chemical Admixtures for Concrete. (Ra\o,„J Af--;36.41/4 41- Richard Hubbard Sr. Technical Marketing Specialist, BASF Corporation BASF Corporation Master 23700 Chagrin Boulvard j j�� 216 Cleveland,39-7 00 OH 44122 Builders 216 839-7500 ph j,,,,,,�) I<,,,( www.masterbuilders.com Admixture Solutions BASF The Chemical Company January 5, 2011 TX! Operations, LP 1341 W. Mockingbird Lane Dallas,Texas 75247 Attention: Victor Villarreal Project:All Projects Project location: Various Certificate of Conformance Pozzolith®200 N BASF Corporation*Admixture for Concrete *(successor in interest to BASF Construction Chemicals, LLC ,which is successor by merger to BASF Admixtures, Inc., formerly known as Degussa Admixtures, Inc.,formerly known as Master Builders, Inc.) I, Richard Hubbard, Sr.Technical Marketing Specialist for BASF Corporation, Cleveland, Ohio,certify: That Pozzolith 200 N is a BASF Corporation Water-Reducing Admixture for concrete; and That no calcium chloride or chloride based ingredient is used in the manufacture of Pozzolith 200 N; and That Pozzolith 200 N, based on the chlorides originating from all the ingredients used in its manufacture, contributes less than 0.00013 percent(1.3 ppm) chloride ions by weight of the cement when used at the rate of 65 mL per 100 kg (1 fluid ounce per 100 pounds) of cement; and That, depending on the dosage used, Pozzolith 200 N meets the requirements for a Type A, Water-Reducing, Type B, Retarding, and Type D, Water Reducing and Retarding Admixture as specified in ASTM C 494, Corps of Engineers' CRD-C 87 and AASHTO M194, the Standard Specifications for Chemical Admixtures for Concrete. Richard Hubbard Sr. Technical Marketing Specialist, BASF Corporation BASF Corporation 1I # � 23700 Chagrin Boulvard Master i C 216 Cleveland,39 7 00 OH 44122 Builders 216 839-7500 ph Builders www.masterbuilders.com Admixture Solutions