Loading...
Townhouses-LR000916 REPORT OF FIELD /i% COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/16/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-62B COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT` % PCF % PCF 1176 09/16/00 FG-6.1 1 22.5 99.5 23.4 97 98 1-A 1177 09/16/00 FG-5.8 1 22.5 99.5 24.5 96 97 1-A 1178 09/16/00 FG-5.7 1 22.5 99.5 23.9 98 98 1-A 1179 09/16/00 FG-5.7 1 22.5 99.5 23.3 98 99 1-A 1180 09/16/00 FG-5.7 2 19.0 100.4 21.2 101 100 1-A 1181 09/16/00 FG-5.7 2 19.0 100.4 22.0 100 100 1-A 1182 09/16/00 FG-5.7 2 19.0 100.4 22.0 98 98 1-A TEST LOCATION: 1176 BLOCK A, PAD#43 1177 BLOCK A, PAD#44 1178 BLOCK A, PAD#45 1179 BLOCK A, PAD#47 1180 BLOCK A, PAD#48 1181 BLOCK A, PAD#49 1182 BLOCK A,PAD#50 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS -. //.. 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /1401f 4. CEMENT TREATED D. RETEST • 12, • TI G,I . Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Con Iti , REPORT OF FIELD / ,, COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/16/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-62A COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1169 09/16/00 FG-6.8 2 19.0 100.4 21.1 96 96 1-A 1170 09/16/00 FG-6.8 2 19.0 100.4 20.1 99 99 1-A 1171 09/16/00 FG-62 2 19.0 100.4 20.4 99 98 1-A 1172 09/16/00 FG-6.8 2 19.0 100.4 21.8 • 97 97 1-A 1173 09/16/00 FG-6.3 2 19.0 100.4 21.3 99 98 1-A 1174 09/16/00 FG-6.4 2 19.0 100.4 21.1 99 99 1-A 1175 09/16/00 FG-7.1 2 19.0 100.4 21.7 98 97 1-A TEST LOCATION: 1169 BLOCK A,PAD#35 1170 BLOCK A,PAD#36 1171 BLOCK A,PAD#38 1172 BLOCK A,PAD#39 1173 BLOCK A, PAD#39 1174 BLOCK A,PAD#40 1175 BLOCK A,PAD#41 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS j� - ' 3. UME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS `• 4. CEMENT TREATED D. RETEST ALP., ' TI ,IN• Geotechnical Engineering 1 Construction Materials Testing I Environmental Engineering I Con llti • REPORT OF FIELD X COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 1 TESTED FOR LEMP DEVELOPMENT DATE 09/16/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-62 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY oENsrn MOISTURE DRY DENSITY COMPACTION COMMEND % PCF % PCF 1162 09/16/00 FG-6.7 1 22.5 99.5 23.2 97 97 1-A 1163 09/16/00 FG-6.7 1 22.5 99.5 23.0 98 98 1-A 1164 09/16/00 FG-6.8 1 22.5 99.5 23.4 97 98 1-A 1165 09/16/00 FG-6.8 2 19.0 100.4 21.3 99 99 1-A 1166 09/16/00 FG-6.8 2 19.0 100.4 20.9 100 100 1-A 1167 09/16/00 FG-6.8 2 19.0 100.4 20.4 99 98 1-A 1168 09/16/00 FG-6.7 2 19.0 100.4 21.6 98 97 1-A TEST LOCATION: 1162 BLOCK A,PAD#27 1163 BLOCK A,PAD#28 1164 BLOCK A,PAD#29 1165 BLOCK A, PAD#30 1166 BLOCK A,PAD#32 1167 BLOCK A,PAD#33 1168 BLOCK A,PAD#34 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MORE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS // / / 2. NATURAL SUBfiRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS i � . 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS / ,- 4. CEMENT TREATED D. RETEST AL% r S G,IN . Geotechnicel Engineering I Construction Materials Testing I Environmental Engineering I Co ult •