Loading...
Townhouses-LR000918 REPORT OF FIELD / COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/18/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-66B COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OP IMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMEND % PCF % PCF 1253 09/18/00 FG-6.4 4 20.1 101.9 21.0 102 100 1-A 1254 09/18/00 FG-6.4 4 20.1 101.9 22.0 100 98 1-A 1255 09/18/00 FG-8.1 4 20.1 101.9 21.3 101 100 1-A 1256 09/18/00 FG-7.6 4 20.1 101.9 21.0 101 99 1-A 1257 09/18/00 FG-5.9 4 20.1 101.9 21.0 102 100 1-A 1258 09/18/00 FG-5.9 4 20.1 101.9 20.9 102 100 1-A 1259 09/18/00 FG-7.1 _ 4 20.1 101.9 22.8 99 98 1-A TEST LOCATION: 1253 BLOCK A,PAD#51 1254 BLOCK A,PAD#52 1255 BLOCK A, PAD#54 1256 BLOCK A, PAD#54 1257 BLOCK A, PAD#51 1258 BLOCK A,PAD#52 1259 BLOCK A, PAD#54 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 1.1" N/r 3. LIME STABIUZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST 7 " I =,INC. Geotechnical Engineering I Constriction Materials Testing I Environmental Engineering I Con Ni r REPORT OF FIELD Nik COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/18/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-66A COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSrrY COMPACTION COMMENT* % PCF % PCF 1246 09/18/00 FG-5.2 4 20.1 101.9 22.0 102 100 1-A 1247 09/18/00 FG-52 4 20.1 101.9 22.7 100 98 1-A 1248 09/18/00 FG-5.3 4 20.1 101.9 21.2 102 100 1-A 1249 09/18/00 FG-5.5 4 20.1 101.9 21.9 99 97 1-A 1250 09/18/00 FG-5.7 4 20.1 101.9 21.7 100 99 1-A 1251 09/18/00 FG-5.8 4 20.1 101.9 20.5 102 100 1-A 1252 09/18/00 FG-4.7 4 20.1 101.9 212 101 99 1-A TEST LOCATION: 1246 BLOCK B, PAD#24 1247 BLOCK B, PAD#25 1248 BLOCK B, PAD#17 1249 BLOCK B, PAD#18 1250 BLOCK B,PAD#19 1251 BLOCK B, PAD#20 1252 BLOCK B,PAD#24 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS - -Ale1 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST •LP ; -, N=,INC. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Cons i , REPORT OF FIELD / ,, COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/18/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-66 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMEND % PcF % PcF 1239 09/18/00 FG-5.8 4 20.1 _ 101.9 21.8 100 98 1-A 1240 09/18/00 FG-6.0 4 20.1 101.9 20.9 102 100 1-A 1241 09/18/00 FG-62 4 20.1 101.9 20.8 102 100 1-A 1242 09/18/00 FG-6.3 4 20.1 101.9 21.4 • 100 98 1-A 1243 09/18/00 FG-6.0 4 20.1 . 101.9 21.8 101 99 1-A 1244 09/18/00 FG-6.0 4 20.1 101.9 21.3 100 98 1-A 1245 09/18/00 FG-6.0 4 _ 20.1 101.9 23.3 99 97 1-A TEST LOCATION: 1239 BLOCK B,PAD#17 1240 BLOCK B, PAD#18 1241 BLOCK B, PAD#19 1242 BLOCK B, PAD#20 1243 BLOCK B, PAD#21 1244 BLOCK B,PAD#22 • 1245 BLOCK B, PAD#23 CC: STEVE TOPLETZ,ANDANTE 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / / /2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS . �/ - . e 3. UME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ./0 ' 4. CEMENT TREATED D. RETEST A .. S NG, C. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Co ulU g REPORT OF FIELD /I COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/18/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-65B COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 1232 09/18/00 FG-6.3 2 19.0 100.4 21.7 97 96 1-A 1233 09/18/00 FG-6.5 2 19.0 100.4 22.0 98 98 1-A 1234 09/18/00 FG-6.7 2 19.0 100.4 21.4 100 99 1-A 1235 09/18/00 FG-6.8 2 19.0 100.4 21.8 100 100 1-A 1236 09/18/00 FG-6.5 2 19.0 100.4 21.4 97 96 1-A 1237 09/18/00 FG-6.5 2 19.0 100.4 21.9 97 96 1-A 1238 09/18/00 FG-6.5 2 19.0 100.4 19.4 102 102 1-A TEST LOCATION: 1232 BLOCK B, PAD#17 1233 BLOCK B,PAD#18 1234 BLOCK B, PAD#19 1235 BLOCK B,PAD#20. 1236 BLOCK B, PAD#21 1237 BLOCK B,PAD#22 1238 BLOCK B,PAD#23 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS /// !�;.:- 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 1. P° / 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST i- - , ,I .. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I C.ns , ng REPORT OF FIELD IIAL COMPACTION TESTS ALPHA TESTING, INC. 2209 Wlsconsln St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/18/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-65A COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPT NUMBER MOISTURE DRY DENSrTY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1225 09/18/00 FG-7.0 2 19.0 100.4 21.1 98 98 1-A 1226 09/18/00 FG-6.8 2 19.0 100.4 22.8 98 97 1-A 1227 09/18/00 FG-5.7 2 19.0 , 100.4 20.6 100 100 1-A 1228 09/18/00 FG-5.7 2 19.0 s 100.4 21.3 100 100 1-A 1229 09/18/00 FG-7.0 2 19.0 100.4 20.7 97 97 1-A 1230 09/18/00 FG-7.0 2 19.0 , 100.4 21.2 96 96 1-A 1231 09/18/00 FG-7.0 2 19.0 100.4 20.2 100 100 1-A TEST LOCATION: 1225 BLOCK B,PAD#18 1226 BLOCK B, PAD#17 1227 BLOCK B,PAD#25 1228 BLOCK B,PAD#24 1229 BLOCK B,PAD#23 1230 BLOCK B, PAD#22 1231 BLOCK B, PAD#21 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS , 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS '/IY S ' / 3. UME STABIUZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS '/' 4. CEMENT TREATED D. RETEST •LP, • rr ,IN' Geotechnical Engineering I Constn,ction Materials Testing I Environmental Engineering I Cons•It! • REPORT OF FIELD /i., COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/18/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-65 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT` % PCF % PCF 1218 09/18/00 FG-6.2 2 19.0 100.4 22.5 96 96 1-A 1219 09/18/00 FG-6.2 4 20.1 101.9 20.2 101 99 1-A 1220 09/18/00 FG-7.5 4 20.1 101.9 21.3 101 99 1-A 1221 09/18/00 FG-7.5 4 20.1 101.9 20.5 99 97 1-A 1222 09/18/00 FG-7.5 4 20.1 101.9 20.2 101 99 1-A 1223 09/18/00 FG-7.3 4 20.1 101.9 20.6 103 101 1-A 1224 09/18/00 FG-7.3 4 20.1 101.9 22.7 98 97 1-A TEST LOCATION: 1218 BLOCK B, PAD#25 1219 BLOCK B, PAD#24 1220 BLOCK B, PAD#23 1221 BLOCK B, PAD#22 1222 BLOCK B,PAD#21 1223 BLOCK B, PAD#20 1224 BLOCK B, PAD#19 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2. NATURAL SUBORADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS )01r 4. CEMENT TREATED O. RETEST • l .P ,I / Geotechnical Engineering I Construction Materials Testing I Environmental Engineering 1 Con ulti