Loading...
Townhouses-LR000921 REPORT OF FIELD / ,. COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/21/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-83B COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1197 09/21/00 FG-4.3 4 20.1 101.9 20.8 101 99 1-A 1198 09/21/00 FG-4.5 4 20.1 101.9 20.2 102 100 1-A 1199 09/21/00 FG-4.7 4 20.1 101.9 21.0 101 99 1-A 1200 09/21/00 FG-4.8 4 20.1 101.9 21.9 100 98 1-A 1201 09/21/00 FG-5.0 4 20.1 101.9 21.1 101 99 1-A 1202 09/21/00 FG-5.0 4 20.1 101.9 22.2 99 98 1-A 1203 09/21/00 FG-5.0 4 20.1 101.9 21.7 101 99 1-A TEST LOCATION: 1197 BLOCK B, PAD#17 1198 BLOCK B, PAD#18 1199 BLOCK B, PAD#19 1200 BLOCK B, PAD#20 1201 BLOCK B, PAD#21 1202 BLOCK B, PAD#22 1203 BLOCK B, PAD#23 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBORADE B. PERCENT COMPACTI(N!DOES NOT COMPLY WITH SPECIFICATIONS t , fitted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS // i 4. CEMENT TREATED D. RETEST ALP • T 'G,IN . Geotechnical Engineering 1 Construction Materials Testing /Environmental Engineering 1 Cons i g REPORT OF FIELD / ,. COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 I TESTED FOR LEMP DEVELOPMENT DATE 09/21/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-63A COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1190 09/21/00 FG-4.2 4 20.1 101.9 21.6 98 96 1-A 1191 09/21/00 FG-4.7 4 20.1 101.9 21.3 99 97 1-A 1192 09/21/00 FG-4.2 4 20.1 101.9 20.5 100 98 1-A 1193 09/21/00 FG-5.7 4 20.1 101.9 21.8 100 98 1-A 1194 09/21/00 FG-5.7 4 20.1 101.9 20.4 102 100 1-A 1195 09/21/00 FG-5.8 4 20.1 101.9 21.4 100 99 1-A 1196 09/21/00 FG-5.8 4 20.1 101.9 20.3 102 100 1-A - TEST LOCATION: 1190 BLOCK B, PAD#24 1191 BLOCK B, PAD#25 1192 BLOCK B,PAD#25 1193 BLOCK A,PAD#27 1194 BLOCK A,PAD#28 1195 BLOCK A,PAD#29 1196 BLOCK A,PAD#30 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS •-�' Iii/ /ed 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS _ / I. CEMENT TREATED D. RETEST AL • • .'S .G,I/. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Co su ng REPORT OF FIELD Nik COMPACTION TESTS ALPHA TESTING, INC. 2209 WJsconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) i FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/21/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-63 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY oENsrnv COMPACTION COMMENT* % PCF % PCF 1183 09/21/00 FG-5.8 4 20.1 101.9 20.4 99 98 1-A - 1184 09/21/00 FG-5.8 4 20.1 101.9 21.3 100 98 1-A 1185 09/21/00 FG-5.7 4 20.1 101.9 20.5 103 101 1-A 1186 09/21/00 FG-5.8 4 20.1 101.9 21.7 101 99 1-A 1187 09/21/00 FG-5.8 4 20.1 101.9 20.6 101 100 1-A 1188 09/21/00 FG-5.2 4 20.1 101.9 21.7 99 97 1-A 1189 09/21/00 FG-5.3 4 20.1 101.9 21.1 100 98 1-A TEST LOCATION: 1183 BLOCK A, PAD#32 1184 BLOCK A, PAD#33 1185 BLOCK A, PAD#34 1186 BLOCK A, PAD#35 1187 BLOCK A,PAD#36 1188 BLOCK A,PAD#38 1189 BLOCK A, PAD#39 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS /, ili 2. NATURAL S08GRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 4004 S . - 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST / • P i -- 'G,IN . Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Cons Ili •