Loading...
Townhouses-LR001001 REPORT OF FIELD / COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/30/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-74B COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 1421 09/30/00 FG-2.9 4 20.1 101.9 20.4 104 102 1-A 1422 09/30/00 FG-3.1 4 20.1 101.9 20.4 101 99 1-A 1423 09/30/00 FG-2.6 4 20.1 101.9 20.1 101 99 1-A 1424 09/30/00 FG-2.8 4 20.1 101.9 , 23.6 98 97 1-A 1425 09/30/00 FG-2.7 4 20.1 101.9 22.2 101 99 1-A 1426 09/30/00 FG-2.7 4 20.1 101.9 21.2 102 100 1-A 1427 09/30/00 FG-2.7 4 20.1 _ 101.9 _ 22.8 98 _ 96 1-A TEST LOCATION: 1421 BLOCK A, PAD#40 1422 BLOCK A, PAD#41 1423 BLOCK A, PAD#43 1424 BLOCK A, PAD#44 1425 BLOCK A, PAD#45 1426 BLOCK A, PAD#47 1427 BLOCK A, PAD#48 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 1 / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Alie S itted 3. LIME STABILIZED . C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST • P • T S G,IN . Geotechnical Engineering / Construction Materials Testing I Environmental Engineering Cons Iti, REPORT OF FIELD / ,, COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) I FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/30/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-74A COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRYDENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 1414 09/30/00 FG-3.3 2 19.0 100.8 19.8 101 100 1-A 1415 09/30/00 FG-3.3 2 19.0 100.8 20.7 99 99 1-A 1416 09/30/00 FG-3.2 2 19.0 100.8 20.9 99 99 1-A 1417 09/30/00 FG-3.3 4 20.1 101.9 23.1 99 97 1-A 1418 09/30/00 FG-3.3 4 20.1 101.9 21.3 101 99 1-A 1419 09/30/00 FG-2.7 4 20.1 101.9 21.0 102 100 1-A 1420 09/30/00 FG-2.8 4 20.1 101.9 21.6 101 99 1-A TEST LOCATION: 1414 BLOCK A, PAD#32 1415 BLOCK A, PAD#33 1416 BLOCK A, PAD#34 1417 BLOCK A, PAD#35 1418 BLOCK A, PAD#36 1419 BLOCK A, PAD#38 1420 BLOCK A, PAD#39 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R •' ■Iy SJ�'/IK-. 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS / 4. CEMENT TREATED D. RETEST ' TING,I '. ' Geotechnical Engineering 1 Construction Materials Testing I Environmental Engineering I Con Iti REPORT OF FIELD 11/INL COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin S1,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 09/30/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-74 COPPELL,TEXAS TEST DATA TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSrry MOISTURE DRY DENSITY COMPACTION COMMEND % PCP % PCF 1407 , 09/30/00 FG-2.2 2 19.0 100.8 - 19.3 98 97 1-A 1408 09/30/00 FG-2.3 2 19.0 100.8 , 19.0 97 96 1-A ` 1409 09/30/00 FG-2.4 2 19.0 100.8 20.4 96 95 1-A 1410 , 09/30/00 FG-3.2 2 19.0 100.8 19.4 98 97 1-A 1411 09/30/00 FG-3.2 2 19.0 100.8 , 19.3 99 98 1-A 1412 , 09/30/00 FG-3.3 2 19.0 100.8 19.3 98 97 1-A 1413 09/30/00 FG-3.3 2 19.0 100.8 19.3 100 100 1-A TEST LOCATION: 1407 BLOCK A, PAD#23 1408 BLOCK A, PAD#124 1409 BLOCK A, PAD#25 1410 BLOCK A, PAD#27 1411 BLOCK A, PAD#28 1412 BLOCK A, PAD#29 1413 BLOCK A, PAD#30 CC: STEVE TOPLETZ,ANDANTE iI. FILL *A IN PLACE PERCENT MOISTURE MID PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Sy/ 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ed 4. CEMENT TREATED D. RETEST ;/,, - I `.INC. Geotechnical Engineering 9 Construction Materials Testing P Environmental Engineering .' Con in