Loading...
Townhouses-LR001005 REPORT OF FIELD Nk COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 1 TESTED FOR LEMP DEVELOPMENT DATE 10/05/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-79B COPPELL,TEXAS TEST DATA: TEST t ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMEND % PCF % PCF 1526 10/05/00 FG-2.1 5 12.5 108 16.0 107 99 1-A 1527 10/05/00 FG-1.6 5 12.5 108 15.3 109 101 1-A 1528 10/05/00 FG-1.1 5 12.5 108 15.2 107 99 1-A 1529 10/05/00 FG-1.7 4 20.1 101.9 22.2 102 100 1-A 1530 10/05/00 FG-1.8 4 20.1 101.9 20.8 103 101 1-A 1531 10/05/00 FG-2.0 4 20.1 101.9 22.6 101 99 1-A 1532 10/05/00 FG-2.0 4 20.1 101.9 21.2 103 101 1-A TEST LOCATION: 1526 BLOCK A, PAD#54 1527 BLOCK A, PAD#54 1528 BLOCK A, PAD#54 1529 BLOCK B,PAD#19 • 1530 BLOCK B, PAD#20 1531 BLOCK B, PAD#21 1532 BLOCK B,PAD#22 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS i 1 / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS /r - Su. t ed 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS i 4. CEMENT TREATED D. RETEST ' • T . , ,IN'. Geotechnicai Engineering I Construction Materials Testing it Environmental Engineering Con RI REPORT OF FIELD X COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 10/05/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-79A COPPELL,TEXAS ,: TEST DATA:. TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1519 10/05/00 FG-1.2 5 12.5 108 16.3 108 100 1-A 1520 10/05/00 FG-1.3 5 12.5 108 16.5 108 100 1-A 1521 10/05/00 FG-1.4 5 12.5 108 16.0 108 100 1-A 1522 10/05/00 FG-0.9 5 12.5 108 15.5 109 101 1-A 1523 10/05/00 FG-1.8 5 12.5 108 14.8 107 99 1-A 1524 10/05/00 FG-1.2 5 12.5 108 16.4 106 98 1-A 1525 10/05/00 FG-0.8 5 12.5 108 15.6 108 100 1-A TEST LOCATION: 1519 BLOCK A, PAD#23 1520 BLOCK A, PAD#24 1521 BLOCK A, PAD#25 1522 BLOCK A, PAD#51 1523 LIBERTY CIRCLE AT STATION#0+55 1524 LIBERTY CIRCLE AT STATION#1+50 1525 LIBERTY CIRCLE AT STATION#3+20 CC: .STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS' Hy S ' `'ed 3. UME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST AL- T,=-TI G,IN'. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering Consulti REPORT OF FIELD /i �. COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 1W Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 10/05/00 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-79 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF S PCF 1512. 10/05/00 FG-2.0 5 12.5 108 15.2 106 98 1-A 1513 10/05/00 FG-1.7 5 12.5 108 16.0 106 98 1-A 1514 10/05/00 FG-1.7 5 12.5 108 15.2 107 99 1-A 1515 10/05/00 FG-1.2 5 12.5 .108 15.1 108 100 1-A 1516 10/05/00 FG-1.2 5 12.5 108 16.5 109 101 1-A 1517 10/05/00 FG-1.2 5 12.5 108 15.7 107 99 1-A 1518 . 10/05/00 FG-1.3 5 12.5 108 15.3 109 101 1-A TEST LOCATION: 1512 BLOCK B, PAD#23 1513 BLOCK B, PAD#24 1514 BLOCK B, PAD#25 1515 BLOCK B, PAD#24 1516 BLOCK B, PAD#25 1517 BLOCK B, PAD#19 1518 BLOCK B,PAD#20 • CC: STEVE TOPLETZ,ANDANTE . 1. ALL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ll i 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Ait6-- Ityl Itted, 3. LIME STABILIZED • C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 1 4. CEMENT TREATED D. RETEST AL . , G,I,C. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Consulti ! /