Townhouses-LR010210 REPORT OF FIELD / ,. COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 02/10/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-91 C COPPELL, TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* PCF % PCF 1700 02/10/01 FG-1.0 2 19.0 100.4 21.1 96 96 1-A 1701 02/10/01 FG-1.0 2 19.0 100.4 20.4 97 96 1-A 1702 02/10/01 FG-1.0 2 19.0 100.4 21.9 97 96 1-A TEST LOCATION: COPPELL TOWNHOMES 1700 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#19 1701 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#20 1702 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#21 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Rpec Ily S ted 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENT TREATED D. RETEST ALP • IN , INC / \ Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Consult. g REPORT OF FIELD )1116, COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 02/10/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-91 B COPPELL, TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1693 02/10/01 FG-3.0 2 19.0 100.4 20.1 98 98 1-A 1694 02/10/01 FG-2.0 2 19.0 100.4 20.0 99 99 1-A 1695 02/10/01 FG-2.0 2 19.0 100.4 19.9 100 100 1-A 1696 02/10/01 FG-2.0 2 19.0 100.4 20.9 99 99 1-A 1697 02/10/01 FG-1.0 2 19.0 100.4 21.6 97 97 1-A 1698 02/10/01 FG-1.0 2 19.0 100.4 21.4 98 98 1-A 1699 02/10/01 FG-1.0 2 19.0 100.4 22.8 97 96 1-A TEST LOCATION: COPPELL TOWNHOMES 1693 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 1694 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 1695 SANITARY SEWER LATTERAL LINE, 20'SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 1696 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 1697 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 1698 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 1699 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 CC: STEVE TOPLETZ, ANDANTE 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS -/ p= tfully '..'.miffed 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS // 4 CEMENT TREATED D. RETEST AL'.- ' S NG, I Geotechnical Engineering 1 Construction Materials Testing 1 Environmental Engineering 1 Consu ing l REPORT OF FIELD //,. COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 02/10/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-91A COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1686 02/10/01 FG-5.0 2 19.0 100.4 21.3 98 98 1-A 1687 02/10/01 FG-5.0 2 19.0 100.4 19.4 100 99 1-A 1688 02/10/01 FG-4.0 2 19.0 100.4 19.4 101 100 1-A 1689 02/10/01 FG-4.0 2 19.0 100.4 20.3 100 99 1-A 1690 02/10/01 FG-4.0 2 19.0 100.4 20.7 98 98 1-A 1691 02/10/01 FG-3.0 2 19.0 100.4 20.1 99 99 1-A 1692 02/10/01 FG-3.0 2 19.0 100.4 19.8 100 99 1-A TEST LOCATION: COPPELL TOWNHOMES 1686 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 1687 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 1688 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 1689 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 1690 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 1691 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 1692 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 CC: STEVE TOPLETZ, ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS RI•e (Ully S itted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4 CEMENT TREATED D. RETEST /• P ' .TI,' ,INC Geotechnical Engineering 1 Construction Materials Testing 1 Environmental Engineering 1 Consulti g / REPORT OF FIELD N6, COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 I TESTED FOR LEMP DEVELOPMENT DATE 02/10/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-91 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 1679 02/10/01 FG-7.0 2 19.0 100.4 20.9 99 99 1-A 1680 02/10/01 FG-7.0 2 19.0 100.4 19.1 101 101 1-A 1681 02/10/01 FG-7.0 2 19.0 100.4 20.3 99 99 1-A 1682 02/10/01 FG-6.0 2 19.0 100.4 20.4 98 97 1-A 1683 02/10/01 FG-6.0 2 19.0 100.4 20.4 100 99 1-A 1684 02/10/01 FG-6.0 2 19.0 100.4 19.8 99 99 1-A 1685 02/10/01 FG-5.0 2 19.0 100.4 19.9 99 99 1-A TEST LOCATION: COPPELL TOWNHOMES 1679 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 1680 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 1681 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 1682 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 1683 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8'WEST OF SOUTHEAST CORNER OF BUILDING#24 1684 SANITARY SEWER LATTERAL LINE, 25' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#25 1685 SANITARY SEWER LATTERAL LINE, 20' SOUTH AND 8' EAST OF SOUTHWEST CORNER OF BUILDING#23 CC: STEVE TOPLETZ,ANDANTE 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS // 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R-'-pe, ully o'mitte. 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS , 4 CEMENT TREATED D. RETEST AL•, /• T S G, I . Geotechnical Engineering M Construction Materials Testing 1 Environmental Engineering 1 Consul ng