Townhouses-LR010222 REFL)RT OF FIELD COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 02/22/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-105 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' PCF % PCF 1796 02/22/01 FG-3.0 2 19.0 100.4 20.8 98 97 1-A 1797 02/22/01 FG-2.0 2 19.0 100.4 22.4 97 97 1-A 1798 02/22/01 FG-1.0 2 19.0 100.4 19.4 99 99 1-A TEST LOCATION: 1796 8"WATER LINE 50' EAST FROM THE 2ND FIRE HYDRANT ALONG CENTER OF TRENCH 1797 8"WATER LINE 50'WEST FROM THE 2ND FIRE HYDRANT ALONG CENTER OF TRENCH 1798 8"WATER LINE 150'WEST FROM THE 2ND FIRE HYDRANT ALONG CENTER OF TRENCH CC: STEVE TOPLETZ,ANDANTE /% 1. FILL * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS R et, ally . itte 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS / 4 CEMENT TREATED D. RETEST AL2,• S ING,I Geotechnical Engineering / Construction Materials Testing /Environmental Engineering /Con•ulti g l/ 1/ r. REP. AT OF FIELD /k COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 02/22/01 DALLAS, TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-102 COPPELL, TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT` % PCF % PCF 1784 02/22/01 FG-3.0 2 19.0 100.4 21.6 98 97 1-A 1785 02/22/01 FG-2.0 2 19.0 100.4 19.5 99 99 1-A 1786 02/22/01 FG-1.0 2 19.0 100.4 20.7 99 99 1-A TEST LOCATION: 1784 8"WATER LINE 10' WEST FROM THE FIRE HYDRANT#1 ALONG CENTER LINE OF TRENCH 1785 8"WATER LINE 10'WEST FROM THE FIRE HYDRANT#1 ALONG CENTER LINE OF TRENCH 1786 8"WATER LINE 10' WEST FROM THE FIRE HYDRANT#1 ALONG CENTER LINE OF TRENCH CC: STEVE TOPLETZ, ANDANTE 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST ALPHA TESTING,INC. Geotechnical Engineering {b Construction Materials Testing / Environmental Engineering Consulting