Loading...
Townhouses-LR010320 REPOR 1 OF FIELD 1/ COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas,Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 03/20/01 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-110 COPPELL,TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 1828 03/20/01 FG-9.0 4 20.1 101.9 21.1 102 100 1-A 1829 03/20/01 FG-8.0 4 20.1 101.9 21.4 101 99 1-A 1830 03/20/01 FG-7.0 3 21.6 98.8 21.6 97 98 1-A 1831 03/20/01 FG-6.0 1 22.5 99.5 22.5 96 96 1-A 1832 03/20/01 FG-8.0 1 22.5 99.5 23.9 97 98 1-A 1833 03/20/01 FG-7.0 2 19.0 100.4 20.4 98 98 1-A 1834 03/20/01 FG-6.0 2 19.0 100.4 21.3 98 97 1-A TEST LOCATION: 1828 SANITARY SEWER MAIN LINE F AT STATION#5+00 1829'MILTARY SEWER 5 MA1N`til {E F i'F "'Sl`AT'f�'3�f= , 1830 SA 4EW R,MAIN-kINE F A'.SST, T k 4-B.-a.. 4 1831 SANITARY SEW L t LINE FAT-STATION#5.+00 1832 SAN TTARY SEWW-31YINN U.NE E:AT.STATION#6 05 1833 S `ARY,SE R MAIN•LINE F'AT STATION#6+00 1834 SPI[I TARY SEWER MAIN LINE F AT STATION#6+05 CC: STEVE TOPLETZ,ANDANTE // I 1 FILL 'A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2 NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS -,- peel,.ly Su ed 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENT TREATED D. RETEST . • P • - . N ,INC. / Our test results&reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or distr.uted e ept wi express appr I of ALPHA The use of our name&test results must receive our written approval. Test results&reports apply only to the samples tested and/or observed,and are not indicative of the ualitie of apparently id tical or similar specimens. Geotechnical Engineering I Construction Materials Testing I Environmental Engineering I Consulting MIL Kti'O T OF FIELD /i'' COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St.,Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937(Metro) FAX: 972/406-8023 TESTED FOR LEMP DEVELOPMENT DATE 03/20/01 DALLAS,TEXAS PROJECT COPPELL TOWNHOMES OUR REPORT NO. 00430-109 COPPELL, TEXAS TEST DATA: TEST ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO DATE DEPTH NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT' % PCF % PCF 1821 03/20/01 FG-12.0 2 19.0 100.4 20.4 102 101 1-A 1822 03/20/01 FG-11.0 2 19.0 100.4 20.5 101 100 1-A 1823 03/20/01 FG-10.0 2 19.0 100.4 20.7 100 100 1-A 1824 03/20/01 FG-12.0 2 19.0 100.4 22.2 99 98 1-A 1825 03/20/01 FG-11.0 4 20.1 101.9 20.2 102 100 1-A 1826 03/20/01 FG-10.0 4 20.1 101.9 20.1 102 100 1-A 1827 _ 03/20/01 FG-9.0 2 _ 19.0 _ 100.4 21.3 101 _ 100 _ 1-A TEST LOCATION: 1821 SANITARY SEWER L1NE'-FAT-STATIAAI-#64.0 ...-;.::. 1822 $ANITARYS5W R.:LINE:FAT ST.ATIO. L#5*AA-- 1823 SANITAI3XaSEyyER LINE FA_I,STA IGN°#5 tO-, 1824 SAMITARY EiYIEP ;.L,l<N.E F.F17'.tTAa"I•If34,#6 01 .: 1825 SANITARY SEWER LINE F.AT STATION#6+05 1826 SANITARY SEWER LINE F AT STATION#6±10 1827 SANITARY SEWER LINE'F AT STATION#6+10 CC: STEVE TOPLETZ,ANDANTE 1 FILL *A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS / 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS . • / 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Pec y S�, ed 4. CEMENT TREATED D. RETEST d ALP/• NG,INC. Our test results 8 reports are for the exclusive use of the Client(and their designated recipients on file in our office)and shall not be reproduced and/or d, ibuted e-ept ' express appro ,I of ALPHA. The use of our name 8 test results must receive our written approval. Test results 8 reports apply only to the samples tested and/or observed,and are not indicative of the uallt of apparently id;r ical or similar specimens. Geotechnical Engineerng M Construction Materials Testing I Environmental Engineering I Consulting