Townhouses-LR010510 ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
l Dallas, Texas 75229
(972) 620-8911 Report
Tested For: LEMP DEVELOPMENT Our Report No.: 00430-115
ATTN: GREG LEMP Issue Date: 05/10/2001
4101 MCGWEN,SUITE 110
DALLAS,TX 75244
Fax Number: (972)404-1833
Project Desc: COPPELL TOWNHOMES
COPPELL,TEXAS
FIELD DATA
Placement Location: MANHOLE, LIBERTY CIRCLE @ STATION 3+44.52
Date Placed: 4/5/01 Plant Number: 6-4200
Time Placed: 4:10 PM Delivery Ticket No.: 6146771
Slump(ASTM C-143): 2.0 Made By: ALPHA
Air Content: N/A
Air Temperature: 76
Cured Specification: ASTM C-31
Specimen Temperature: 74
Date Received: 4/6/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: AZMAR,OMAR
Mix Data Submitted By: LMC
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
1 LAB C-617 4/12/01 7 12 N/A 6 28.27 70525 2490
2 LAB C-617 5/3/01 28 12 N/A 6 28.27 128346 4540
3 LAB C-617 5/3/01 28 12 N/A 6 28.27 134571 4760
4 LAB HOLD HOLD 12 N/A 6 28.27 0
'Specifications: 28 4000
l Results to Date: PASS
Notes:
Respectfully Submitted By: 111 ir of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client(aesignated recepients on file in our office)and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed,and are not indicative of the qualities of apparently identical or similar specimens.
:N;',:74%,',,,' -Gdotechii4f*ent@oot CQf1Struc o 1 8Tjajs estH a enta oti a t i>ltlbttil l ra f 0703