Townhouses-LR010515 ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911 Report
Tested For: LEMP DEVELOPMENT Our Report No.: 00430-119
ATTN: GREG LEMP Issue Date: 05/15/2001
4101 MCGWEN,SUITE 110
DALLAS,TX 75244
Fax Number: (972)404-1833
Project Desc: COPPELL TOWNHOMES
COPPELL,TEXAS
HELD DATA
Placement Location: INLET BOTTOMS; LINE H @ STATION 2+80&LINE G @ STATION 1+07
Date Placed: 4/10/01 Plant Number: 29-4500
Time Placed: 3:00 PM Delivery Ticket No.: 824999
Slump(ASTM C-143): 3 Made By: ALPHA
Air Content: N/A
Air Temperature: 80 Cured Specification: ASTM C-31
Specimen Temperature: 85
Date Received: 4/11/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: HENSHAW,EKENG A
Mix Data Submitted By: HANSON
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
9 LAB C-617 4/17/01 7 12 N/A 6.02 28.46 108898 3820
10 LAB C-1231 5/8/01 28 12 N/A 6 28.27 163680 5780
11 LAB C-1231 5/8/01 28 12 N/A 6 28.27 169929 6010
12 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 4000
Results to Date: PASS
Notes:
Respectfully Submitted By: J� 17 of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client( ir designated recepients on file in our office)and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed,and are not Indicative of the qualities of apparently identical or similar specimens.