Townhouses-LR010517 )L, ALPHA TESTING, INC. Concrete Compression Test
2209 Wisconsin St., Suite to 10 100
Dallas, Texas 75229
(972) 620-8911 Report
Tested For: LEMP DEVELOPMENT Our Report No.: 00430-131
ATTN• GREG LEMP Issue Date: 05/17/2001
4101 MCGWEN,SUITE 110
DALLAS,TX 75244
Fax Number: (972)404-1833
Project Desc: COPPELL TOWNHOMES
COPPELL,TEXAS
FIELD DATA
Placement Location: TRIPPLE BOX CULVERT BASE,LINE A @ STATION 0+80
Date Placed: 5/4/01 Plant Number: 29-4500
Time Placed: 4:15 PM Delivery Ticket No.: 818374
Slump(ASTM C-143): 2.0 Made By: ALPHA
Air Content: N/A
Air Temperature: 77 Cured Specification: ASTM C-31
Specimen Temperature: 83
Date Received: 5/5/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: AZMAR,OMAR
Mix Data Submitted By: HANSON
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
13 LAB C-1231 5/11/01 7 12 N/A 6 28.27 149831 5300
14 LAB 6/1/01 28 12 N/A 6 28.27 0
15 LAB 6/1/01 28 12 N/A 6 28.27 0
16 LAB HOLD HOLD 12 N/A 6 28.27 0
jSpecifications: 28 4000
Results to Date: N/A
Notes:
Respectfully Submitted By: U of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed,and are not Indicative of the qualifies of apparently identical or similar specimens.
. � ,gyp-� .("' ..,. ,l3 aca.c
� ,�=_ � , 1 b