Loading...
Townhouses-LR010529 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test ///, Dallas, Texas 75229 (972) 620-8911 Report Tested For: LEMP DEVELOPMENT Our Report No.: 00430-136 ATTN: GREG LEMP Issue Date: 05/29/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,STATION 5+60 ON INDEPENDENCE DR. Date Placed: 5/17/01 Plant Number: N/A Time Placed: 9:15 AM Delivery Ticket No.: N/A Slump(ASTM C-143): 2 Made By: ALPHA Air Content: 4.3 (ASTM C-173) Air Temperature: 73 Cured Specification: ASTM C-31 Specimen Temperature: 84 Date Received: 5/18/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORESE, NICHOLAS Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 21 LAB C-1231 5/24/01 7 12 N/A 6 28.27 66495 2350 22 LAB 6/14/01 28 12 N/A 6 28.27 0 23 LAB 6/14/01 28 12 N/A 6 28.27 0 24 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 I Results to Date: N/A Notes: Respectfully Submitted By: of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not Indicative of the qualities of apparently Identical or similar specimens. Geotechnical Engineering*Construction Materials Testing* Environmental Engineering*Consulting 8271 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test Dallas, Texas 75229 (972) 620-8911 Report Tested For: LEMP DEVELOPMENT Our Report No.: 00430-137 ATTN: GREG LEMP Issue Date: 05/29/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,STATION 1+07 ON LIBERTY CIRCLE Date Placed: 5/17/01 Plant Number: -3600 Time Placed: 11:45 AM Delivery Ticket No.: 21834 Slump(ASTM C-143): 3 Made By: ALPHA Air Content: 4.6 (ASTM C-173) Air Temperature: 76 Cured Specification: ASTM C-31 Specimen Temperature: 85 Date Received: 5/18/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORESE,NICHOLAS Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 25 LAB C-1231 5/24/01 7 12 N/A 6 28.27 89900 3180 26 LAB 6/14/01 28 12 N/A 6 28.27 0 27 LAB 6/14/01 28 12 N/A 6 28.27 0 28 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 Results to Date: N/A Notes: Respectfully Submitted By: �/ of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not indicative of the qualities of apparently identical or similar specimens. Geotechnical Engineering*Construction Materials Testing* Environmental Engineering*Consulting 8272 ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Concrete Compression Test � Dallas, Texas 75229 Report (972) 620-8911 Re p Tested For: LEMP DEVELOPMENT Our Report No.: 00430-138 ATTN: GREG LEMP Issue Date: 05/29/2001 4101 MCGWEN,SUITE 110 DALLAS,TX 75244 Fax Number: (972)404-1833 Project Desc: COPPELL TOWNHOMES COPPELL,TEXAS FIELD DATA Placement Location: PAVING,STATION 4+50 ON COLONIAL DR. Date Placed: 5/17/01 Plant Number: -3600 Time Placed: 3:45 PM Delivery Ticket No.: 21868 Slump(ASTM C-143): 2.5 Made By: ALPHA Air Content: 4.4 (ASTM C-173) Air Temperature: 82 Cured Specification: ASTM C-31 Specimen Temperature: 92 Date Received: 5/18/01 Delivery Method: PICKED UP BY ALPHA Field Data Submitted By: FORESE,NICHOLAS Mix Data Submitted By: SITE CYLINDER COMPRESSION TEST RESULTS Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI: 29 LAB C-1231 5/24/01 7 12 N/A 6 28.27 94922 3350 30 LAB 6/14/01 28 12 N/A 6 28.27 0 31 LAB 6/14/01 28 12 N/A 6 28.27 0 32 LAB HOLD HOLD 12 N/A 6 28.27 0 Specifications: 28 3000 I Results to Date: N/A Notes: Respectfully Submitted By: of Alpha Testing, Inc. Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed,and are not Indicative of the qualities of apparently Identical or similar specimens. Geotechnical Engineering*Construction Materials Testing* Environmental Engineering*Consulting 8273