Townhouses-LR010530 ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100 Concrete Compression Test
Dallas, Texas 75229
(972) 620-8911 Report
Tested For: LEMP DEVELOPMENT Our Report No.: 00430-140
ATTN: GREG LEMP Issue Date: 05/30/2001
4101 MCGWEN, SUITE 110
DALLAS,TX 75244
Fax Number: (972)404-1833
Project Desc: COPPELL TOWNHOMES
COPPELL,TEXAS
FIELD DATA
Placement Location: PAVING,STATION 3+18 ON LIBERTY CIRCLE
Date Placed: 5/18/01 Plant Number: -3600
Time Placed: 2:45 PM Delivery Ticket No.: 21904
Slump(ASTM C-143): 5 Made By: ALPHA
Air Content: 5.3 (ASTM C-173)
Air Temperature: 80 Cured Specification: ASTM C-31
Specimen Temperature: 90
Date Received: 5/19/01
Delivery Method: PICKED UP BY ALPHA
Field Data Submitted By: FORESE,NICHOLAS
Mix Data Submitted By: SITE
CYLINDER COMPRESSION TEST RESULTS
Lab Cure Cap Date Age Avg. Avg. Avg Depth/ Area: Max
No.: Type: Spec: Tested: (Days): Length Width Diameter Sq.In. Load: PSI:
37 LAB C-1231 5/25/01 7 12 N/A 6 28.27 85777 3030
38 LAB 6/15/01 28 12 N/A 6 28.27 0
39 LAB 6/15/01 28 12 N/A 6 28.27 0
40 LAB HOLD HOLD 12 N/A 6 28.27 0
Specifications: 28 3000
Results to Date: N/A
Notes:
Respectfully Submitted By: V of Alpha Testing, Inc.
Our test results and reports are for the exclusive use of the Client(and their designated recepients on file in our office)and shall not be reproduced and/or distributed except
with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or
observed,and are not indicative of the qualities of apparently identical or similar specimens.
Geotechnical Engineering"Construction Materials Testing* Environmental Engineering*Consulting 8289